• Title/Summary/Keyword: 자장민감도

Search Result 16, Processing Time 0.05 seconds

Magnetoresistive Properties of Array IrMn Spin Valves Devices (어레이 IrMn 스핀밸브 소자의 자기저항특성 연구)

  • Ahn, M.C.;Choi, S.D.;Joo, H.W.;Kim, G.W.;Hwang, D.G.;Rhee, J.R.;Lee, S.S.
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.4
    • /
    • pp.156-161
    • /
    • 2007
  • To develop array magnetic sensors, specular-type giant magnetoresistive- spin valve (GMR-SV) film of Glass/Ta(5)MiFe(7)/IrMn(10)NiFe(5)/$O_2$/CoFe(5)/Cu(2.6)/CoFe(5)/$O_2$/NiFe(7)/Ta(5)(nm) was deposited by using a high-vacuum sputtering system. One of 15 way sensors in the area of $8{\times}8mm^2$ was Patterned a size of $20{\times}80{\mu}m^2$ in multilayer sample by Photo-lithography. All of 15 sensors with Cu electrodes were measured a uniform magnetic properties by 2-probe method. The highest magnetic sensitivity of MR and output voltage measured nearby an external magnetic field of 5 Oe were MS = 0.5%/Oe and ${\triangle}$V= 3.0 mV, respectively. An easy-axis of top-free layers of $CoFe/O_2/NiFe$ with shape anisotropy was perpendicular to one of bottom-pinned layers $IrMn/NiFe/O_2/CoFe$. When the sensing current increased from 1 mA to 10 mA, the output working voltage uniformly increased and the magnetic sensitivity was almost stable to use the nano-magnetic devices with good sensitive properties.

Quantitative Analysis of Susceptibility Effects in TRFGE and CGE Sequences for Functional MRI (뇌기능 영상을 위한 TRFGE와 CGE 기법에서 자화율 효과의 정량적 해석)

  • 정순철;노용만;조장희
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.66-74
    • /
    • 1997
  • fMRI, functional MRI introduced receently appears based on the gradient echo technique which is sensitive to the field inhomogeneity developed due to the local susceptibility changes of blood oxygenation and deoxygenation. There has been many variants of the basic gradient echo sequence which is sensitive to the local inhomogeniety, among others such as GRASS or SSFP to EPISTAR are the most commonly used gradient echo techniques. Common to all these gradient echo techniques is that the signal due to the susceptibility effects is generally decreased with increasing inhomogeneity due to the $T2^{*}$ effect or conventionally konwn as blood oxygenation level dependent(BOLD) effect. It is, also found that the BOLD sensitivity is also dependent on the imaging modes, namely whether the imaging is in axial, or coronal or sagittal mode as well as the directions of the vessels against the main magnetic field. We have, therefore, launched a systematic study of imaging mode dependent signal change or BOLD sensitivity as well as the signal changes due tothe tilting angle of the imaging planes. Study has been made for both TRFGE sequence and CGE sequence to compare the distinctions of the each mode since each technique has different sensitivity againsst susceptibility effect. Method of computation and both the computer simulations and their corresponding experimental results are presented.

  • PDF

DFMT Electromagentic Transducer for Implantable Middle Ear Hearing Aid (이식형 인공중이 시스템을 위한 차동 플로팅매스형 전자 튜랜스듀서)

  • 송병섭;박재훈;윤영호;배상곤;채승표;김명남;이상흔;이건일;조진호
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.5
    • /
    • pp.625-632
    • /
    • 1999
  • 이식형 인공중이에 사용되는 전자트랜스듀서는 압전형 트랜스듀서에 비해 음향특성은 좋으나 부피가 크고 효율이 낮으며 수술시 정밀한 코일-자석 간격 조정이 필요하며, 최근 제안된 FMT 트랜스듀서는 외부 자장의 변화에 민감하다는 문제점이 지적되고 있다. 본 논문에서는 코일-자석 간격조정이 필요 없고 외부자장에 영향을 받지 않는 차동 플로팅메스형 전자 트랜스듀서를 제안하였다. 제안된 방식은 2개의 소형 자석을 같은 극끼리 접합함으로써 외부자장에 대해 영향을 받지 않고 효율이 높은 등의 장점을 가진다. 제안된 트랜스듀서의 진동력 및 효율에 관한 정량적인 해석을 하였으며 기존의 트랜스듀서와 비교분석을 행하였다. 그리고 공급전류에 대해 발생되는 진동력의 크기를 계산함으로서 실제 이식형 인공중이의 제작에 필요한 객관적인 설계데이타를 제시하였다. 한편, 시험 제작된 트랜스듀서의 해석결과 제안한 트랜스듀서는 기존의 FMT 트랜스듀서보다도 효율이 1.5배 정도의 향상됨을 보였으며 무부하시험 및 사체의 이소골 진동실험을 통하여 적절한 진동을 효과적으로 이소골에 전달할 수 있음을 보였다.

  • PDF

내장형 선형 ICP(Inductively Coupled Plasma) system에서 자장이 플라즈마와 PR 식각특성에 미치는 영향

  • 김경남;이영준;경세진;염근영
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.3-3
    • /
    • 2003
  • 고밀도 플라즈마를 생산할 수 있는 대면적용 플라즈마 소스의 개발은 미세전자구조 산업에서부터 FPD 산업에 이르기까지 많은 영역에 걸쳐 필수 불가결한 기술요소가 되어가고 있 다. 이러한 대면적용 고밀도 플라즈마에의 적용을 위하여 새로운 유도결합형 플라즈마 소오스의 개발이 진행되고 있으며, 차세대 반도체 식각 및 세정 공정을 위하여 여러 형태의 안 테나가 연구되어지고 있다. 그러나 TFT -LCD에 적용이 가능하게끔 기존의 ICP 소오스를 직 접적으로 대면적화 하는 데에는 여러 가지 문제점들로 인해 그 한계점이 들어났다. 그 예로 안테나의 길이가 길어짐에 따른 안테나 저항 값이 커지며, 안테나 소스 길이자체가 사용하는 인가전력(13.56MHz)의 반파장에 해당되는 길이가 되었을 경우 생기는 심각한 정상파 효과, 유전물질의 두께 증가 및 그에 따른 재료비의 상승 및 관리상의 어려움들이 바로 그것 이라 할 수 있겠다. 그러므로, 본 연구에서는 차세대 TFT -LCD 대면적 공정에 적용 가능한 고밀도 플라즈마 를 발생시키기 위해서 내장형 유도결합형 선혈 안테나를 사용하였다. 내장형 유도결합형 선 혈 안테나가 가지고 있는 고유의 정전기적 결합효과를 최소화시키기 위해 직사각형모앙의 플라즈마 댐버(830mm*1,020mm)에서 영구자석을 사용하여 multi-cusp 자장효과 및 다양 한 자장의 배열에 따른 플라즈마 특성변화를 살펴보았다. 영구자석을 사용하여 외부자장을 인가하였을 때가, 그럴지 않은 때보다 RF 안테나 코일의 전압을 낮춰주었으며, 영구자석의 배열에 따라 코일의 인덕턴스의 값이 크게 변함을 알 수 있었다. 그리고 최적화된 자장의 배열은 플라즈마의 이온밀도를 증가시켰으며, 플라즈마의 균일도도 10% 이내로 유지됨을 알 수 있었다. 또한 영구자석에 의한 자장의 유무 및 공정압력과 인가전력에 따른 P Photoresist Film의 식각특성에 관해 살펴보았다.증을 위한 실험.측정장비의 구입 및 업계와의 공동활용, 국내.외 최신기술 정보자료의 수집과 신속제공, 국내.외 전문가 초청 활 용, 미래 지향적 목적활용 기초연구사업 수행, 미래기술 동향예측 및 홍보 등을 통해 서 국내 도금기술의 기술자립 및 고도화를 위한 여건마련을 위하여 노력하고 있다.빛 이때의 부식속도(선형분극법), 인위적인 피막 파괴 전,후 의 전위 변화 및 부식속도 측정법에 의한 국부부식 발달 저지능 등을 평가하여 각 실험결과를 비교분석하여 보았다. 수록 민감하여 304 의 IGSCC 와 매우 유사한 거동을 보인다. 본 강연에서는 304 와 600 의 고온 물에서 일어나는 IGSCC 민감도에 미치는 환경, 예민화처리, 합금원소의 영향을 고찰하고 이에 대한 최근의 연구 동향과 방식 방법을 다룬다.다.의 목적과 지식)보다 미학적 경험에 주는 영향이 큰 것으로 나타났으며, 모든 사람들에게 비슷한 미학적 경험을 발생시키는 것 이 밝혀졌다. 다시 말하면 모든 사람들은 그들의 문화적인 국적과 사회적 인 직업의 차이, 목적의 차이, 또한 환경의 의미의 차이에 상관없이 아름다 운 경관(High-beauty landscape)을 주거지나 나들이 장소로서 선호했으며, 아름답다고 평가했다. 반면에, 사람들이 갖고 있는 문화의 차이, 직업의 차 이, 목적의 차이, 그리고 환경의 의미의 차이에 따라 경관의 미학적 평가가 달라진 것으로 나타났다.corner$적 의도에 의한 경관구성의 일면을 확인할수 있지만 엄밀히 생각하여 보면 이러한 예의 경우도 최락의 총체적인 외형은 마찬가지로 $\ulcorner$순응$\lrcorner$의 범위를 벗어나지 않는다. 그렇기 때문에도 $\ulcorner$순응$\lrcorner$$\ulcorner$표현$\lrcorner$

  • PDF

Investigation of Response of Several Neutron Surveymeters by a DT Neutron Generator (DT 중성자 발생기에 의한 중성자 검출기 반응도 조사)

  • Kim, Sang-In;Jang, In-Su;Kim, Jang-Lyul;Lee, Jung-Il;Kim, Bong-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.1
    • /
    • pp.35-40
    • /
    • 2012
  • Several neutron measuring devices were tested under the neutron fields characterized with two distinct kinds of thermal and fast neutron spectrum. These neutron fields were constructed by the mixing of both thermal neutron fields and fast neutron fields. The thermal neutron field was constructed using by a graphite pile with eight AmBe neutron sources. The fast neutron field of 14 MeV was made by a DT neutron generator. In order to change the fraction of fast neutron fluence rate in each neutron fields, a neutron generator was placed in the thermal neutron field at 50 cm and 150 cm from the reference position. The polyethylene neutron collimator was used to make moderated 14 MeV neutron field. These neutron spectra were measured by using a Bonner sphere system with an LiI scintillator, and dosimetric quantities delivered to neutron surveymeters were determined from these measurement results.

Post-annealing Effect of Giant Magnetoresistance-Spin Valve Device for Sensor (센서용 거대자기저항 스핀밸브소자의 열처리 효과)

  • Lee, Sang-Suk;Park, Sang-Hyun;Soh, Kwang-Sup;Joo, Ho-Wan;Kim, Gi-Wang;Hwang, D.G.
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.4
    • /
    • pp.172-177
    • /
    • 2007
  • In order to detect of the magnetic property in the cell unit, we studied the GMR-SV (giant magnetoresistance-spin valves) biosensor, which was depended on the micro patterned features according to two easy directions of longitudinal and transversal axes. Here, the multi layer structure was glass/NiO/NiFe/CoFe/Cu/CoFe/NiFe. The uniaxial anisotropy direction was applied to the patterned biosensor during the deposition and vacuum post-annealing at $200^{\circ}C$ under the magnitude of 300 Oe, respectively. Considering the magnetic shape anisotropy effect, the size of micro patterned biosensor was a $2{\times}5{\mu}m^2$ after the photo lithography process. By our experimental results, we confirmed that the best condition of GMR-SV biosensor should be the same direction of the axis sensing current and the easy axis of pinned NiO/NiFe/CoFe triple layer oriented to the width direction of device, and the direction of the easy axis of free CoFe/NiFe bilayer was according to the longitudinal direction of device.

Magnetoresistance Effect of Ta/NiFe/Cu/Co Pseudo Spin Valve Structure (Ta/NiFe/Cu/Co Pseudo 스핀밸브 구조의 자기저항 효과)

  • Joo, Ho-Wan;Choi, Jin-Hyup;Choi, Sang-Dae;Lee, Ky-Am
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.1
    • /
    • pp.25-28
    • /
    • 2004
  • The dependence of sensitivity, MR ratio, coercivity (Hc) and switching fields as a function of thickness of each magnetic layers(Co, NiFe and Cu) were investigated in pseudo spin valves with a structure of Ta/NiFe/Cu/Co. As measured results dependence of the thickness of each magnetic layer, we obtained MR ratio of 7.26% for Ta(4 nm)/NiFe(7.5 nm)/Cu(3 nm)/Co(5 nm) pseudo spin valves. Also, we could control properties of magnetoresistance for independent magnetization courses of each magnetic layer. Especially, we found that we could control coercivity as constant MR ratio dependence of Co thickness.

Transient Analysis of Magnetodynamic Systems Using Fourier Transform and Frequency Sensitivity (푸리에 변환과 주파수 민감도를 이용한 시변자장 시스템에서의 과도상태 해석)

  • Choi, Myung-Jun;Kim, Chang-Hyun;Park, Il-Han
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.64-66
    • /
    • 1998
  • This paper presents a new efficient method for transient analysis in magnetodynamic systems of linear eddy current problems. This mehtod employs the Fourier transform and the high-order frequency sensitivity of harmonic finite element method. By taking into account the time-constant of magnetodynamic system, the Fourier integral of continuous frequency is converted into the Fourier series of discrete frequency. And with the results of Fourier series expansion of converted input wave form, the responses of each sinusoids is superposed to give the total response of the magnetodynamic systems. But, if the frequency band of input wave form is broad, it takes long computational time since all responses for each sinusoids must be calculated. Therefore, the high-order frequency sensitivity method is employed to estimate the response variation to frequency. The proposed algorithm is applied to an induction heating system to validate its numerical efficiency.

  • PDF

Adaptive noise removal in the 40-channel MEG system (40 채널 뇌자도 시스템에서 적응 필터를 이용한 노이즈 제거)

  • Lee, D.H.;Shin, W.C.;Ahn, C.B.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.3213-3215
    • /
    • 2000
  • 뇌자도 신호의 측정은 뇌에서 발생하는 자장 성분을 정밀하게 측정할 수 있으나, 신호의 크기가 매우 작기 때문에 노이즈에 매우 민감하게 동작하며 이러한 노이즈 성분의 발생원인은 외부 환경에 의하여 발생하거나 시스템 내부에서 발생하는 두가지로 나눌 수 있다. 따라서 뇌자도 신호를 측정하는데 있어서 가장 중요한 작업은 신호에 존재하는 노이즈 성분을 제거하는 것이다. 특히 뇌자도 측정 시스템에서는 외부 노이즈 성분을 제거하기 위하여 레퍼런스 채널이 존재한다. 따라서 본 논문에서는 청각 자극 신호에 의한 뇌자도 신호를 측정하고 측정한 데이터를 사용하여 레퍼런스 채널과 입력신호에 대하여 LMS 알고리즘을 이용한 적응 필터를 모델링 하였다. 그리고, 구현한 적응 필터를 이용하여 뇌자도 신호의 평균값, 표준편차의 통계적 결과를 비교하여 모델링한 적응 필터 방법의 유용성을 확인하였다.

  • PDF

Thermal Stability of ${\alpha}-{Fe_2O_3}/Co/Cu/Co$ Spin Valve

  • Jung, Gyu-Jung;Lee, Byeong-Seon;Lee, Chan-Gyu;Lee, Gun-Hwan
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2002.12a
    • /
    • pp.154-155
    • /
    • 2002
  • 스핀밸브형 GMR(Giant magnetoresistance) 소자는 낮은 자장범위에서 큰 자기저항변화가 생기는 높은 민감도의 소자로서, 고밀도 자기기록매체의 재생헤드 및 MRAM(Magnetoresistance Random Access Memory) 등의 실제 응용에 있어 큰 자기저항비와 열적 안정성을 가지는 재료들을 필요로 한다. NiO, a-$Fe_2O_3$, NiO/a-$Fe_2O_3$ 등과 같은 산화물의 경우, 높은 Tn(Neel temperature)을 가지므로 이를 이용한 Bottom형 스핀밸브에 대한 연구가 활발히 진행되어 왔다. (중략)

  • PDF