• Title/Summary/Keyword: 자연열화

Search Result 92, Processing Time 0.032 seconds

Clinical remarks about esthetics in the case of full zirconia restoration utilizing Zirkonzahn Prettau® block (지르코잔 프레타우 블럭을 이용한 Full Zirconia 수복 시 심미에 관한 임상적 소견)

  • Park, Jong-Chan
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.22 no.1
    • /
    • pp.30-46
    • /
    • 2013
  • Porcelain fused to metal crown has been used mostly over the last 50 years for restorations in dentistry. However, the patients' awareness of aesthetic aspect, biocompatibility and the problems such as an allergy to metals led to the growing interest in the 'metal free restoration'. In particular, the price of the precious metals that have been mainly used to date has risen drastically, which made them impossible to play their role as oral restorative materials anymore, and in addition, the PFM restoration has intrinsic problems of chipping and fracture. Therefore, the CAD/CAM has been drawing more attention than ever due to the popular needs for the material that is more aesthetic and stronger for restoration of the molar implant. Considerations in carrying out the full zirconia restoration are as follows: 1) strength, 2) combination work, 3) light penetrability, 4) treatment of cracks, 5) the color reproducibility of the block, 6) the abrasivity of antagonistic tooth, 7) low temperature degradation. In this presentation, the color reproducibility of the block will be discussed. One of the biggest reasons for avoiding the full zirconia restoration is that it is difficult to reproduce the natural color compared to the conventional PFM restoration. Thus, many clinicians show reluctance due to the exposure of the ugly block when the coloring on the surface is removed after occlusal adjustment. From the experience of using blocks by Zirkonzahn for more than 4 years, it is considered that these problems can be addressed to some degrees. Accordingly, how to make restorations that are well in harmony with surrounding prosthesis or natural teeth will be discussed.

Durability Evaluation of Inorganic-Impregnated Concrete Exposed to Long-Term Chloride Exposure Test (무기계 침투제를 적용한 콘크리트의 장기폭로실험을 통한 염해 내구성 평가)

  • Kwon, Seung-Jun;Park, Sang-Soon;Lho, Byeong-Cheol
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.3
    • /
    • pp.283-290
    • /
    • 2008
  • The repair technique using surface impregnation of reactive compound is so effective for deteriorated concrete structures that many researches are recently focused on these works. Particularly, inorganic impregnant is regarded as ecofriendly material because there is no air-pollution during manufacturing process as well as field coating works. Furthermore, The delamination between old concrete and impregnated surface does not occur, resulting from different material characteristics. In order to evaluate the durability performance of surface-impregnated concrete, durability evaluation through the long-term exposure tests is significant, however, experiments are usually limited to the temporary and qualitative laboratorial scope. In this study, durability characteristics for inorganic and organic/inorganic impregnated concrete specimens are evaluated through longterm chloride exposure test. The specimens with 21MPa and 34MPa strength have been prepared and exposed to chloride attack in the atmospheric, tidal, and submerged conditions. Evaluation for compressive strength, chloride penetration, and electrical potential (half cell potential) for steel corrosion are performed for the specimens exposed for 2 years. From the results, no distinct strength gaining is observed but the resistance to chloride penetration and steel corrosion is evaluated to be improved through surface impregnation. The more improved resistance to chloride attack is measured in the inorganic impregnated concrete and the results from atmospheric condition show more improved resistance to chloride attack than those from submerged and tidal condition.

Manufacturing Method and Characteristics of the Dongrok(copper chloride) pigments (동록(염화동) 안료의 제조방법 및 특성에 관한 연구)

  • KANG Yeongseok;PARK Juhyun;MUN Seongwoo;HWANG Gahyun;KIM Myoungnam;LEE Sunmyung
    • Korean Journal of Heritage: History & Science
    • /
    • v.56 no.2
    • /
    • pp.148-169
    • /
    • 2023
  • Hayeob pigment is known as one of the traditional dark green pigments, but the color, raw material, and manufacturing method have not been clearly identified. However, comparing the analysis results of the particle shape and constituent minerals of Hayeob pigments revealed through pigment analysis studies of colored cultural properties such as Dancheong, Gwaebul, and paintings, Hayeob pigments appear to be the same as Dongrok pigments produced by salt corrosion. Therefore, in order to restore Hayeob pigment, the manufacturing method of Dongrok pigment was studied based on the records of old literature. The Dongrok pigment manufacturing method confirmed in the old literature records is a natural corrosion method in which copper powder and a caustic are mixed and then left in a humid condition to corrode. Based on this, artificial corrosion using a corrosion tester was adopted to corrode the copper powder more efficiently, and an appropriate mixing ratio was selected by analyzing the state of corrosion products according to the mixing ratio of the caustic agent. In addition, the manufacturing method of Dongrok pigment was established by adding a salt removal process to remove residual caustic agents and a purification process to increase chroma during pigment coloring. The prepared Dongrok pigments have a bluish green or green color, show an elliptical particle shape and a form in which small particles are aggregated, and a porous surface is observed. The main constituent elements are copper(Cu) and chlorine(Cl), and the main constituent mineral is identified as atacamite [Cu2Cl(OH)3]. As a result of an accelerated weathering test to evaluate the stability of the prepared Dongrok pigments, it was found that the greenness partially decreased and the yellowness significantly increased as deterioration progressed. Before deterioration, the Dongrok pigments had lower yellowness compared to the Hayeob pigments of the old Dancheong, but after deterioration, yellowness increased significantly, and it was found to have a similar chromaticity range as Dancheong's Hayeob pigments. As a result, the prepared Dongrok pigments were confirmed to be similar to Dancheong's Hayeob pigments in terms of color as well as particle shape and constituent minerals.

Analysis Method for Damage Patterns of Low Voltage Switches for PL Judgment (PL 판정을 위한 저압용 스위치의 소손 패턴 해석기법)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.136-141
    • /
    • 2010
  • The purpose of this study is to examine the structure and heat generation mechanism of low voltage switches used to turn on or off the power supply to an indoor lighting system and investigate how the fixtures and movable contacts of the switches are damaged depending on the types of energy sources in order to secure the judgment base for expected PL disputes. Based on the Korean Standard (KS) testing method for incombustibility, this study applied a general flame to the switch. In addition, current was supplied to the switch using the PCITS (Primary Current Injection Test System). The ambient temperature and humidity were maintained at $22{\pm}2^{\circ}C$ and 40~60% respectively while performing the test. It is thought that the switch generated heat due to a defective connection of the wire and clip, insulation deterioration and defective contact of the movable contact, etc. The surface of the switch damaged by the general flame was uniformly carbonized. When the flame source was removed, the fire on the switch was extinguished naturally. From the result obtained by disassembling the switch carbonized by the general flame, it could be seen that fixtures and movable contacts remained in comparatively good shape but the enclosure, clip support, movable contact, indicating lamp, etc. showed carbonization and discoloration. In the case of the switch damaged by overcurrent, the clip connecting the wires, clip support, etc. showed almost no trace of damage, but the fixtures, movable contact, indicating lamp, etc. were severely carbonized. That is, the sections with high contact resistance were intensively damaged and showed a damage pattern indicating that carbonization progressed from the inside to the outside. Therefore, it is possible to judge the initial energy source by analyzing the characteristics of the carbonization pattern and the metal fixtures of damaged switches.

Study on Corrosion and Structural Performance in Hot-Dip Galvanizing Steel (용융아연도금 철근의 부식 특성 및 구조적 특성에 대한 연구)

  • Kwon, Seung-Jun;Lee, Sang-Min;Lee, Myung-Hoon;Park, Sang-Soon
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.5
    • /
    • pp.613-621
    • /
    • 2012
  • Steel corrosion is one of the most critical deteriorations in concrete structures due to the problems associated with both durability and structural safety issues. For protection of steel against corrosion problems, researches to improve concrete durability and steel corrosion protection such as rebar coating by hot-dip galvanizing steel have been carried out. This study was performed to quantitatively evaluate anti-corrosion and structural performance of concrete structures reinforced with hot-dip galvanizing steel rebar. Preliminary tests for several metal coatings such as zinc, aluminum, and their alloy (Zn 45% + AL 55%) were performed. After evaluation of corrosive characteristics, Zn was selected for the coating material and the corrosion behaviors in Zn-coated steel were evaluated in various conditions. Furthermore, tensile and adhesive strengths were evaluated for the normal and the hot-dip galvanized steel. The crack patterns and structural behaviors of RC specimens with the normal and coated steel were investigated. Also, corrosion characteristics including corrosion in various coating metal and potential change in metal with notch were evaluated. Structural performances of tensile and adhesive strengths as well as RC beam behavior under flexural/shear loading were evaluated. The test and evaluation results showed that the applicability of hot-dip galvanized steel rebar can be used as corrosion resistant reinforcements for RC structures.

A Study on Conservation and Material Characteristics of Outdoor Bronze Sculpture : Kim Chan Shik's 'Feeling' (야외 청동 조각작품의 보존과 재질특성 연구 - 김찬식 '정(情)'을 중심으로 -)

  • Kwon, Hee Hong;Kim, Ye Seung;Kim, Beom Jun;Choi, Nam Young;Park, Hye Sun;Kim, Jung Suk
    • Journal of Conservation Science
    • /
    • v.33 no.3
    • /
    • pp.155-165
    • /
    • 2017
  • As interest in the public display of art and outdoor sculptures is increasing, the conservation and treatment of these sculptures is becoming increasingly crucial. Long-term exposure to the natural elements and atmospheric pollution can cause corrosion and deterioration in outdoor sculptures. In the case of Kim Chan Shik's "Feeling", which was exhibited in the outdoor sculpture park at the National Museum of Modern and Contemporary Art (MMCA), the patina of the sculpture was damaged during a long outdoor exhibition. Therefore, the treatment process was as follows: recording of condition, sanding, repatination, and wax coating. Consequently, the sculpture was restored similar to the original. Chemical analysis revealed that the sculpture was crafted from bronze and was cast from a quaternary alloy of Cu-Pb-Sn-Zn. The welding is lower in Zn, Sn, and Pb content than the metal used in the sculpture itself. Bright strains contain about 13.0 wt% Sn and 10.5 wt% Pb. The strains are higher in Sn and Pb content than the rest of the metal in the sculpture (7.0 wt% Sn and 4.4 wt% Pb). As a result of component analysis and microstructure observation, the material is estimated to have been made by casting without artificial treatment.

Introduction to Definition and Basic Role of Performance Measure in Asset Management for Bridge Management (자산관리기법의 교량시설물의 적용에 있어 성능평가지표의 정의 및 역할에 대한 기초연구)

  • Park, Cheol-Woo;Park, Kyung-Hoon;Hwang, Yoon-Koog;Lee, Sang-Yoon;Kong, Jung-Sik;Min, Dae-Hong
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.401-404
    • /
    • 2008
  • Bridges are exposed to very severe environment and experience, as service life increased, elevated traffic load and traffic flow, in addition to natural disasters. In comparing to other road structures, bridges may cause more significant damage, such as human-involved accidents, to the society in the event of collapse. A certain level of service shall be necessarily secured to assure the minimum safety of users. The cost for manage and preserve bridges will increase gradually and more restrictions will be loaded to efficiently distribute the limited resources, such as monetary budget and human resource etc. In order to enhance performance and serviceability of bridges with the limited resource, asset management technique has been applied into the bridge management system, which capitalizes the road infrastructures including bridges and assess them in accordance with the government finance report. In the application of asset management, there must be a tool for assess the performance of bridges and this study introduces the basic information on the definition and role of performance measures for asset management for bridges.

  • PDF

Surface Deterioration Diagnosis of Taejong Heonreung Sindobi Monument using Nondestructive Method (비파괴 기법을 이용한 태종 헌릉 신도비의 표면 훼손도 진단)

  • Lee, Myeong-seong;Park, Sung-mi;Chun, Yun-gun;Lee, Sun-myung;Lee, Jae-man
    • Korean Journal of Heritage: History & Science
    • /
    • v.46 no.4
    • /
    • pp.90-107
    • /
    • 2013
  • The Stone Monument of Taejong King in Heonreung Royal Tomb, Seoul was originally erected in 1424 to pay a tribute to Bang Won Lee's achievement who was named Taejong, the Third King of Joseon Dynasty. The monument has been damaged by Japanese Invasion of Korea in 1592 so that another monument was newly made and erected together with the original monument in 1695. The original monument was made of medium-grained biotite granite for the turtle base and medium-grained milky white crystalline limestone for the stele body and the top stone. The turtle base of the original monument is destroyed beyond the original shape and inscription due to irregular shaped breaking and a set of longitudinal crack. Analyzing the deterioration degree by using nondestructive methods, the 88 percentage of the front area and 38 percentage of the back area of the monument are damaged, and the lower part of the stele body is dominantly deteriorated especially due to the combination of discoloration and physical deterioration. The new monument in 1695 is also made of granite and limestone. The weathering indices of the turtle base and stele body stones by the calculation from ultrasonic velocity are 0.10 and 0.74, respectively. This is because the original monument is presumed to be degraded by heat shock and physical attack during the Japanese war, and the long-term outdoor exposure accelerated the weathering of the monument afterward without protective shelter.

Restoration of the Chimi Excavated from the Busosan Temple Site in Buyeo and Study of Its Production Techniques (부여 부소산사지 출토 치미의 재 복원을 통한 제작기법)

  • Hwang, Hyunsung;Na, Ahyoung
    • Conservation Science in Museum
    • /
    • v.27
    • /
    • pp.1-22
    • /
    • 2022
  • A chimi(a roof ridge decoration) excavated from the Busosan Temple Site in Buyeo was restored in 1978 at the Buyeo Museum. The gypsum restoration material had deteriorated over time and part of it was seriously damaged and unable to bear the weight of the chimi. The chimi features traces of emergency treatment revealing that the inside of the body and some portions of the tail were reinforced several times using epoxy resin. A condition survey performed in preparation for its transfer for an exhibition found the lower body and wings of the chimi to be highly vulnerable and it was determined that the chimi needed further restoration. The dismantling of the chimi for restoration revealed several elements that provide clues to the production techniques applied by its makers, so they were subjected to inspection. This study explores the production techniques used in the chimi from the Busosan Temple Site that were revealed during the process of dismantling it for restoration. The chimi was inspected using 3D scanning and its rigid vertical shape was restored to a natural form based on the production techniques identified during the dismantling process. The existing restoration material was replaced to improve durability. 3D printed elements were produced based on 3D modelling and were joined to the original chimi to correct its shape and fill in the missing parts, restoring the chimi to its original appearance.

Performance Evaluation of Fiber-Reinforced Concrete Compression Members Transversely Constrained by BFRP (BFRP로 횡구속된 섬유 보강 콘크리트 압축부재의 성능평가)

  • Lee, Gyeong-Bok;Lee, Sang-Moon;Jung, Woo-Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.5
    • /
    • pp.607-616
    • /
    • 2022
  • Corrosion and degradation of reinforced structures due to abnormal climates and natural disasters further accelerate the aging of structures. Coping with the decrease in structure performance, many old structures are being repaired and reinforced with low-weight and high-strength materials such as glass fiber composite material (GFRP). To further contribute, this paper focus on a more economical and eco-friendly material, basalt fiber composite (BFRP), which provide a more effective lateral constraint effect for seismic reinforcement. The main variables considered in this study are the curing temperature during the manufacturing of BFRP and the material characteristics of the target concrete member. The lateral constraint reinforcement effect was investigated through the evaluation of the performance of normal concrete and those with improved durability through fiber reinforcement. The reinforcement effect was 3.15 times for normal concrete and 3.72 times for fiber reinforced concrete, and the difference in reinforcement effect due to the improvement of the durability characteristics of the compression member was not significant. Lastly, the performance of the BFRP was compared with the results of the GFRP reinforcement from the previous study. The effect of the BFRP reinforcement was 1.18 times better than that of the GFRP reinforcement.