교류전류를 이용한 결함탐상에 관한 연구 - 주파수와 Lift-off 효과 - (A Study on the Detection of Defects Using AC Current -The Effect of Frequency and Lift-off-)

  • 김훈;김정엽;문봉호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.529-533
    • /
    • 2001
  • NDI technique system using AC current is newly developed for inspection of defects. This technique is non-contact measurement system and can be applied for locating and sizing of surface defects in components. In this paper, the technique was applied for evaluating the location and size for 2-dimensional surface cracks and we had investigated the influence of frequency and lift-off. The results show that defects are able to detect with the variety of voltage, and the measuring voltage for the depth of defects are under the influence of the measuring frequency and the lift-off.

  • PDF

CCFL 구동을 위한 압전변압기 제작과 전기적 특성 (Electrical Characteristics of Manufactured Multilayer Piezoelectric Transformer for driving The CCFL(Cold Cathode Fluorescent Lamp))

  • 한재현;임영철;양승학;권기현
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.777-780
    • /
    • 2002
  • 최근 백라이트용 램프를 구동하기 위해 사용하는 승압용 변압기를 압전 변압기로 도입하는 연구가 활발히 진행되고 있다. 압전 변압기는 종래의 권선 변압기에서 볼 수 있었던 누설 자속과 권선등에 의한 저항 손실이 없으며, 전자유도에 의한 노이즈와 자체 손실이 없고, 권선형의 자기소자로 인한 소형화에 한계를 가지는 큰 단점을 해결해 주고 있다. 본 논문에서는 11층의 적층형 압전 변압기를 제작하고 이 제작된 적층형 압전 변압기의 전기적 특성분석을 통한 CCFL(Cold Cathode Fluorescent Lamp) 구동용 인버터의 승압용 변압기로써 응용가능성을 제시하였다.

  • PDF

강자성체 평판의 자속 누설 탐상 비파괴 실험 및 수치해석 (Non-destructive Testing and Numerical Analysis for Ferromagnetic Plates using Magnetic Flux Leakage Method)

  • 김신;이향범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.126-128
    • /
    • 2001
  • In this paper, Magnetic Flux Leakage(MFL) method is used to detect surface defect in ferromagnetic plate. Surface defects are created on the SM 45C ferromagnetic plate and magnetizing equipment is composed to perform MFL nondestructive testing. The length and width of defect is twice the thickness of ferromagnetic plate, and defects with different depths are made artificially for the experiment. Also, NdFeB magnet in magnetizing equipment is used to make magnetic flux. This paper shows that it is possibile to detect 10% defect and to analyze numerically for any defect using MFL method.

  • PDF

권선단락에 의한 초고압 변압기 권선의 전자력 계산 연구 (An Electromagnetic Force Calculation of Internal Winding Fault in a High Voltage Transformer)

  • 하정우;신판석;한성진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.747-748
    • /
    • 2006
  • 본 연구에서는 전력계통에서 발생되는 surge나 고장전류에 의해서 변압기의 1차측 코일에 유도되는 전자력의 크기를 유한요소 전자계해석 프로그램(FLUX2D)을 이용하여 해석하였다. 400kVA, 6600/220(V) 단상내철형 변압기의 권선간 전자력계산을 축대칭FEM을 이용하여 각방향의 전자력을 분석하였다. 누설자속분포, 전류유입시 권선 상호간에 작용하는 힘의 변화와 힘의 분포, 전류유입시 권선 상호간에 작용하는 힘의 변화와 힘의 분포, 변압기 내부권선의 정상시와 고장전류시의 전자계비교를 전자계해석을 통하여 변압기에 미치는 영향을 해석하였다. 변압기에 대전류가 유입되는 경우의 전자력 분석결과는 변압기의 절연설계 및 단락기계력에 대한 프레임 구조 설계를 위한 자료로 활용된다.

  • PDF

중성선 영상고조파저감용 특수 Reactor 설계와 해석 (A Design and Analysis of a Neutral Line Harmonics Eliminating Reactor)

  • 김철;김한들;김한수;신판석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.52-54
    • /
    • 2004
  • 현대정보화산업에서 배전계통의 부하는 첨단 제어장치, 다양한 반도체 전력변환 설비, OA기기 및 PC 둥의 사용으로 배전계통의 중성선에 영상 고조파가 많이 발생한다. 이것을 최소화하기 위해서 본 연구에서는 중성선의 영상전류를 제거하는 장치인 특수 리액터를 설계하고 유한요소프로그램(Flux2D)을 이용하여 특성을 해석하여 검증하였다. 최적설계를 위하여 누설자속의 최소화, 코아 및 동손의 최소화를 위한 설계알고리즘도 구성하여 최적설계안을 제안하였다.

  • PDF

다(多)출력 DC-DC 플라이백 컨버터용 변압기 설계방법 및 개발 (The Design and Development of Flyback Transformer for Multi - Out Flyback DC-DC Converter)

  • 박종연;강도형
    • 산업기술연구
    • /
    • 제20권B호
    • /
    • pp.163-168
    • /
    • 2000
  • This paper gives a fundamental study of the design method of Flyback Transformer(FBT) in the Multioutput Flyback DC-DC Converter. We explained a winding strategy and Core selecting of the Flyback transformer to get the design guidelines for optimizing the performance of Flyback DC-DC Converter. The final goal of this paper is to obtain design rules of the Flyback transformer to minimize the leakage inductance for good quality of DC Souce.

  • PDF

누설자속을 이용한 sealing-wax용 고주파 공진 인버터에 관한 연구 (A study on the high frequency resonant inverter for sealing wax using a leaks)

  • 원재선;김동희;노채균;민병재;김경식;정성균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1165-1167
    • /
    • 2000
  • This paper describes a current fed high frequency resonant inverter used as the power supply for sealing-wax. The proposed inverter can reduce switching losses, noise and voltage stress at turn-on and turn-off. The analysis of proposed circuit uses normalized parameter and characteristic estimation which is needed in each step before design is generally described according to normalized frequency ($\mu$), coefficient of coupling($\kappa$) and all parameters. The theoretical analysis is proved through experiment and this circuit shows that it can be used practically as the power supply system for sealing wax and DC-DC converter.

  • PDF

80-MW 클라이스트론 부하용 대출력 펄스 트랜스포머의 설계 (Design of High-Power Pulse Transformer for the 80-MW Klystron Load)

  • 장성덕;정성훈;오종석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2119-2122
    • /
    • 2000
  • 포항 방사광 가속기의 선형 가속기에서는 80-MW 클라이스트론 부하를 구동하기 위하여 최대 펄스 정격출력 200 MW(400kv 500A, 평탄도 4.4 $\mu s$)인 대출력 펄스 트랜스포머가 요구된다. 펄스 트랜스포머는 펄스 전원공급 장치(Modulator)로부터 대출력 부하(Klystron)로 펄스 에너지를 전달하며 임피던스 정합을 시키는 기능을 한다. 모듈레이터의 고전압 출력 펄스에서 RF 에너지를 발생시키는데 사용되는 유효 출력 에너지는 출력 펄스의 평탄부의 에너지에 해당된다. 그러므로, 펄스 트랜스포머는 빠른 상승시간을 가지는 것이 요구된다. 빠른 상승시간을 얻기 위하여 누설자속, 분포용량이 작게 되도록 설계하여야 한다.

  • PDF

변압기 외함 자계손실/온도상승 계산 및 실증시험 (Calculation of Loss/Temperature rise for Tank-wall of Transformer and Field-test)

  • 김동현;김창욱;박성원;최명준;서흥석;박상봉
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.925-926
    • /
    • 2007
  • 전자계 및 열/유동 해석 프로그램을 활용한 수치해석적 방법으로 변압기 외함의 자계손실과 온도상승을 계산하는 경우, 많은 시간이 소요되기 때문에, 설계 또는 고객 요구시 신속한 대응이 어렵다. 따라서 3차원 간이 계산법을 정립하여 신속 정확한 해석적 방법으로 접근할 필요가 있었다, 본 연구에서는 권선의 누설자속에 의해 발생하는 변압기 외함의 자계손실을 계산하고 이에 따른 온도상승을 추정하고자 하였다. 또한, 실제 변압기의 온도상승 시험을 통해 온도상승 계산 결과의 정확성을 검증하고자 하였다.

  • PDF

누설자속에 의한 대용량 변압기의 권선지지구조 및 외함의 와전류손실 계산에 관한 연구 (The Loss Calculation of Eddy Current of the Tank and Winding Supports in Transformers by the Leakage Flux)

  • 허우행;이동엽;김규탁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.948-950
    • /
    • 2005
  • This paper compared the test data with the loss when a conductor is exposed to the magnetic fieldof reactors after generating external magnetic field in specimen by means of an air core reactor model and the calculation of loss came from a tying the combination of FEM and integral method. It was applied to the loss measurement of transformers due to leakage flux.

  • PDF