• Title/Summary/Keyword: 자성 센서

Search Result 100, Processing Time 0.021 seconds

Anisotropy Control of Highly Magnetostrictive Films by Bias Stress (바이어스 응력에 의한 고자왜 아몰퍼스 박막의 자기이방성 제어)

  • Shin, Kwang-Ho;Kim, Young-Hak;Park, Kyung-Il;Sa-Gong, Geon
    • Journal of the Korean Magnetics Society
    • /
    • v.13 no.5
    • /
    • pp.193-197
    • /
    • 2003
  • To materialize the magnetoelastic devices, such as a highly functional sensor and a signal processing device, using the Fe base amorphous film which has both excellent soft magnetic and magnetostrictive properties, in this study, a new method to control the magnetic anisotropy of a highly magnetostrictive film using bias stress has been proposed and tested. The film pattern, which was stressed by its substrate bending, was subjected to annealing for relieving its stress. Successively, the compressive stress occurred by flattening the substrate was formed in the pattern. With the introduction of the residual compressive stress, the magnetization of the film pattern was aligned in the transverse direction through magnetoelasic coupling. The magnetic domain structure and magnetization curve of the film pattern of which magnetic anisotropy was controlled by the proposed method were presented to verify the availability of the method.

Application of Linear Spectral Mixture Analysis to Geological Thematic Mapping using LANDSAT 7 ETM+ and ASTER Satellite Imageries (LANDSAT 7 ETM+와 ASTER영상정보를 이용한 선형분광혼합분석 기법의 지질주제도 작성 응용)

  • Kim Seung Tae;Lee Kiwon
    • Korean Journal of Remote Sensing
    • /
    • v.20 no.6
    • /
    • pp.369-382
    • /
    • 2004
  • The purpose of this study is the investigation of applicability of LSMA(Linear Spectral Mixture Analysis) on the geological uses with different radiometric and spatial types of sensor images such as Terra ASTER and LANDSAT 7 ETM+. As for the actual application case, geologic mapping for mineral exploration using ASTER and ETM+ at the Mongolian plateau region was carried out. After the pre-processing such as the geometric corrections and calibration of radiance, 7 endmembers, as spectral classes for geologic rock types, related to spectral signature deviation for the given application was determined by the pre-surveyed geological mapping information and the correlation matrix analysis, and total 20 images of ASTER and ETM+ were used to LSMA processing. As the results, fraction maps showing individual mineral types in the study area are presented. It concluded that this approach based on LSMA using ETM+ and ASTER is regarded as one of the effective schemes for geologic remote sensing.

Development for the Azimuth Measurement Algorithm using Multi Sensor Fusion Method (멀티센서 퓨전 기법을 활용한 방위 측정 알고리즘의 설계)

  • Kim, Tae-Yeong;Kim, Young-Chul;Song, Moon-Kyou;Chong, Kil-To
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.2
    • /
    • pp.865-871
    • /
    • 2011
  • Presently, the location and direction information are certainly needed for the autonomous vehicle of the ship. Among them, the direction information is a essential elements to automatic steering system. And the gyro-compass, the magnetic-compass and the GPS compass are the sensor indicating the direction. The gyro-compasses are mainly used in the large-sized ship of the GMDSS(Global Maritime Distress & Safety System). The precision and the reliability of the gyro-compasses are excellent but big volume and high price are disadvantage. The magnetic-compass has relatively fine precision and inexpensive price. However, the disadvantage is in the influence by the magnetism object including the steel structure of a ship, and etc. In the case of the GPS compass, the true north is indicated according to the change of the location information but in case of the minimum number of satellites or stopping of a ship or exercise in the error range, the exact direction cannot be obtained. In this paper, the performance of the GPS compass was improved by using the least-square curve fitting method for the mutual trade off of the angle sensor. The algorithm which improves the precision of an azimuth by applying the weighted value according to the size of covariance error was proposed with GPS-compass and magnetic compass. The characteristic and the performance of the proposed algorithm were analyzed and verified through experimentation. The applicability of the proposed algorithm was shown through the experimental result.

K-DEV: A Borehole Deviation Logging Probe Applicable to Steel-cased Holes (철재 케이싱이 설치된 시추공에서도 적용가능한 공곡검층기 K-DEV)

  • Yoonho, Song;Yeonguk, Jo;Seungdo, Kim;Tae Jong, Lee;Myungsun, Kim;In-Hwa, Park;Heuisoon, Lee
    • Geophysics and Geophysical Exploration
    • /
    • v.25 no.4
    • /
    • pp.167-176
    • /
    • 2022
  • We designed a borehole deviation survey tool applicable for steel-cased holes, K-DEV, and developed a prototype for a depth of 500 m aiming to development of own equipment required to secure deep subsurface characterization technologies. K-DEV is equipped with sensors that provide digital output with verified high performance; moreover, it is also compatible with logging winch systems used in Korea. The K-DEV prototype has a nonmagnetic stainless steel housing with an outer diameter of 48.3 mm, which has been tested in the laboratory for water resistance up to 20 MPa and for durability by running into a 1-km deep borehole. We confirmed the operational stability and data repeatability of the prototype by constantly logging up and down to the depth of 600 m. A high-precision micro-electro-mechanical system (MEMS) gyroscope was used for the K-DEV prototype as the gyro sensor, which is crucial for azimuth determination in cased holes. Additionally, we devised an accurate trajectory survey algorithm by employing Unscented Kalman filtering and data fusion for optimization. The borehole test with K-DEV and a commercial logging tool produced sufficiently similar results. Furthermore, the issue of error accumulation due to drift over time of the MEMS gyro was successfully overcome by compensating with stationary measurements for the same attitude at the wellhead before and after logging, as demonstrated by the nearly identical result to the open hole. We believe that the methodology of K-DEV development and operational stability, as well as the data reliability of the prototype, were confirmed through these test applications.

Regional Distribution of Isotropy Magnetic Property of Dual-type Giant Magnetoresistance-Spin Valve Multilayer (이중구조 거대자기저항-스핀밸브 박막의 자기등방성 영역분포에 관한 연구)

  • Khajidmaa, Purevdorj;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.6
    • /
    • pp.193-199
    • /
    • 2013
  • The regional distribution of magnetic isotropy depending on the post annealing condition for the dual-type structure GMR-SV (giant magnetoresistance-spin valve) of NiFe/Cu/NiFe/IrMn/NiFe/Cu/NiFe multilayer was investigated. The rotation of in-plane ferromagnetic layer induced by controlment of the post annealing temperature inside of the vacuum chamber. The magnetoresistive curves of a dual-type IrMn based GMR-SV depending on the direction of the magnetization easy axis of the free layer and the pinned layer are measured by between $0^{\circ}$ and $360^{\circ}$ angles for the applied fields. The optimum annealing temperature having a steady and isotropy magnetic sensitivity of 1.52 %/Oe was $107^{\circ}C$ in the rotational section of $0{\sim}90^{\circ}$. By investigating the switching process of magnetization for an arbitrary measuring direction, the in-plane orthogonal magnetization for the dual-type GMR-SV multilayer can be used by a high sensitive biosensor for detection of magnetized micro-beads.

Exchange coupling field of NiFe/IrMn/CoFe trilayer depending on Mn composition (3중박막 NiFe/IrMn/CoFe에서 Mn 함유량에 의존하는 교환결합세기)

  • 김보경;이진용;함상희;김순섭;이상석;황도근;김선욱;이장로
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2003.06a
    • /
    • pp.130-131
    • /
    • 2003
  • The magnetic and thermal properties of NiFe/IrMn/CoFe with Mn additions have been studied. As grown CoFe pinned-layers with IrMn-Mn have dominantly larger exchange biasing field( $H_{ex}$) and blocking temperature( $T_{b}$) than when pure I $r_{22}$M $n_{78}$ is used. The magnetic properties improve, $H_{ex}$ and $T_{b}$ improve with 77-78 vol% Mn, but drop considerably with more Mn additions, losing magnetic properties of theb NiFe/IrMn/CoFe with addition 0.6 vol % Mn. The average x-ray diffraction peak ratios fcc (111)CoFe of (111)IrM $n_3$ textures for the Mn inserted total vol of 75, 77, and 79 vol% were about 1.4, 0.8, and 0.6, respectively. For the sample without Mn inserted layer, the $H_{ex}$ between I $r_{22}$M $n_{78}$ and CoFe layers is almost nothing. For two multilayer as-grown samples with ultra-thin Mn layers of 77 vol % and 79 vol %, the $H_{ex}$s are 250 Oe and 150 Oe, respectively. In case of IrMn with 77.5 vol% Mn, the $H_{ex}$ was 444 Oe up to 30$0^{\circ}C$ endured of 363 Oe at 40$0^{\circ}C$, respectively. Mn additions improve the magnetic properties and thermal stabilities of NiFe/IrMn/CoFe. Those increase the $H_{ex}$ and $T_{b}$. In applications where higher $H_{ex}$ and $T_{b}$ are accept, proper concentrations of Mn can be used.n can be used.be used.

  • PDF

A Study on the Performance Improvement of Bar Code Reader for the Automatic Processing of the Mail Items (우편물 자동처리를 위한 바코드 판독기 성능개선에 관한 연구)

  • Park, Moon-Sung;Nam, Yun-Seok;Kim, Hey-Kyu
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2001.04b
    • /
    • pp.731-734
    • /
    • 2001
  • 우편물을 집배원이 배달하는 순서로 자동구분 처리하기 위한 요소기술 줌에서 4-state 바코드 시스템이 개발되고 있으며 우편번호, 배달순서코드, 고객정보 등이 적용될 예정이다. 기존의 고객 바코드 판독 시스템은 우편물상의 바코드 심볼로지가 존재하는 판독대상 영역의 기울기가 ${\pm}4.47^{\circ}$ 이하이고, 심볼의 훼손과 잡영이 없을 경우에 $79{\sim}100msec(35,000{\sim}45,000$통/시간)의 속도로 자동 구분 정보가 판독된다. 본 논문에서는 판독범위 및 판독성능을 개선을 위하여 CCD(Charge Coupled Device) 센서로부터 획득된 이미지상에서 존재하는 심볼로지 정보의 고속판독 방법을 제시한 것이다. 이 판독방법은 그레이(gray) 이미지 바탕면의 경계값(threshold) 기울기 분포를 기준으로 2개의 경계값을 설정하여 판독대상 정보를 획득하였다. 또한, 4-state 바코드 심볼로지의 존재 가능성 영역만을 탐색하고, 판독대상 영역에서 트래커(tracker)를 탐색하여 심볼로지의 기울기값, 심볼로지 경계값, 심볼위치 좌표값을 생성한 후 심볼값이 판독한 것이다. 판독시험 결과는 판독대상 영역의 심볼로지가 ${\pm}45^{\circ}$ 기울어지고, 잡영이 존재할 경우에도 $30{\sim}60msec(58,000{\sim}l16,000$통/시간) 이내에 판독되었다. 우편물 자동구분용 바코드 판독기로써 적용될 경우에 판독속도가 평균 57.25% 이상 개선되고, 판독범위의 확장으로 0.2%의 기계적인 오류(이송과정예서의 Jam 발생 비율)를 제외할 경우에 거의 99.8% 우편물을 판독하여 자동구분 처리할 수 있게 될 것으로 기대된다.onebook 엑세스 모들(Server Phonebook Access Module)로 구성되어 있다.외 보다 높았다(I/O ratio 2.5). BTEX의 상대적 함량도 실내가 실외보다 높아 실내에도 발생원이 있음을 암시하고 있다. 자료 분석결과 유치원 실내의 벤젠은 실외로부터 유입되고 있었고, 톨루엔, 에틸벤젠, 크실렌은 실외뿐 아니라 실내에서도 발생하고 있었다. 정량한 8개 화합물 각각과 총 휘발성 유기화합물의 스피어만 상관계수는 벤젠을 제외하고는 모두 유의하였다. 이중 톨루엔과 크실렌은 총 휘발성 유기화합물과 좋은 상관성 (톨루엔 0.76, 크실렌, 0.87)을 나타내었다. 이 연구는 톨루엔과 크실렌이 총 휘발성 유기화합물의 좋은 지표를 사용될 있고, 톨루엔, 에틸벤젠, 크실렌 등 많은 휘발성 유기화합물의 발생원은 실외뿐 아니라 실내에도 있음을 나타내고 있다.>10)의 $[^{18}F]F_2$를 얻었다. 결론: $^{18}O(p,n)^{18}F$ 핵반응을 이용하여 친전자성 방사성동위원소 $[^{18}F]F_2$를 생산하였다. 표적 챔버는 알루미늄으로 제작하였으며 본 연구에서 연구된 $[^{18}F]F_2$가스는 친핵성 치환반응으로 방사성동위원소를 도입하기 어려운 다양한 방사성의 약품개발에 유용하게 이용될 수 있을 것이다.었으나 움직임 보정 후 영상을 이용하여 비교한 경우, 결합능 변화가 선조체 영역에서 국한되어 나타나며 그 유의성이 움직임 보정 전에 비하여 낮음을 알 수 있었다. 결론: 뇌활성화 과제 수행시에 동반되는 피험자의 머리 움직임에 의하여 도파민 유리가 과대평가되었으며 이는 이 연구에서 제안한 영상정합을 이용한 움직임 보정기법에 의해서 개선되었다. 답이 없는 문제, 문제 만

  • PDF

Synthesis of Prussian Blue Analogue and Magnetic and Adsorption Characteristics of MnFe2O4 (프러시안 블루 유사체의 합성 및 MnFe2O4의 자성과 흡착 특성)

  • Lee, Hye-In;Kang, Kuk-Hyoun;Lee, Dong-Kyu
    • Journal of the Korean Applied Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.67-74
    • /
    • 2016
  • The Prussian Blue Analogue(PBA) has three dimensional structure and the metal - organic framework material, and it has a variety configurations depending on the type of organic ligands. PBA has been receving an attention in the fields of biosensors, optical, catalytic, and hydrogen storage device. Also, it is an environmental friendly substance with a chemical stability. In addition, PBA is widely used in the filed of adsorption art since we can adjust the size of the fine pores. In this study, we synthesized $Mn_3[Fe(CN)_6]_2$, an organometallic framework chains by using a hydrothermal synthesis method. We used $K_4[Fe(CN)_6]$ and $MnCl_2$ as precursors. We also produced a manganese iron oxide, by baking the synthesized material. The effect of the size and shape of the particles was examined by controling pH of the precursor solution, the molar concentration of the precursor, and reaction time as the experimental variables. Synthesized absorbent was analyzed by XRD, SEM, FT-IR, UV-Vis, and TG / DTA to evaluate the adsorption properties of several dyes.

Effect of Co content on Magnetoresistance in Rapid Solidified CuCo ribbons (급속 응고된 CuCo 리본의 Co 조성에 따른 자기저항 변화)

  • Song, Oh-Sung;Yoon, Ki-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.2
    • /
    • pp.120-125
    • /
    • 2006
  • By employing a rapid solidification method and atmospheric annealing at $450^{\circ}C-1hr$, we were able to manufacture inexpensively granular CuCo alloy ribbons with thickness of $20{\mu}m$ showing giant magnetoresistance (GMR) ratio of more than 5% at a high magnetic field of 0.5T. To verify maximum MR effect, the MR ratio, saturation magnetization, and microstructure change were investigated with Co contents between 5 and 30 at%. It was possible to obtain GMR ratios of 5.2% at 1.2T, and 3% at 0.5T, which implies an appropriate MR for industrial purpose at a Co content of $8{\sim}l4%$. MR ratio was reduced rapidly at a Co content below 5% due to superparamagnetic effect and at a Co content above 20% due to agglomeration of Co clusters. Surface oxidation during rapid solidification and atmospheric annealing did not have much affect on MR ratio. Our result implies that our economic CuCo granular alloy ribbons may be appropriate for high magnetic field sensor applications with wide content range of $8{\sim}14$ at%Co.

  • PDF

A New Correction Method for Ship's Viscous Magnetization Effect on Shipboard Three-component Magnetic Data Using a Total Field Magnetometer (총자력계를 이용한 선상 삼성분 자기 데이터의 선박 점성 자화 효과에 대한 새로운 보정 방법 연구)

  • Hanjin Choe;Nobukazu Seama
    • Geophysics and Geophysical Exploration
    • /
    • v.27 no.2
    • /
    • pp.119-128
    • /
    • 2024
  • Marine magnetic surveys provide a rapid and cost-effective method for pioneer geophysical survey for many purposes. Sea-surface magnetometers offer high accuracy but are limited to measuring the scalar total magnetic field and require dedicated cruise missions. Shipboard three-component magnetometers, on the other hand, can collect vector three components and applicable to any cruise missions. However, correcting for the ship's magnetic field, particularly viscous magnetization, still remains a challenge. This study proposes a new additional correction method for ship's viscous magnetization effect in vector data acquired by shipboard three-component magnetometer. This method utilizes magnetic data collected simultaneously with a sea-surface magnetometer providing total magnetic field measurements. Our method significantly reduces deviations between the two datasets, resulting in corrected vector anomalies with errors as low as 7-25 nT. These tiny errors are possibly caused by the vector magnetic anomaly and its related viscous magnetization. This method is expected to significantly improve the accuracy of shipborne magnetic surveys by providing corrected vector components. This will enhance magnetic interpretations and might be useful for understanding plate tectonics, geological structures, hydrothermal deposits, and more.