• Title/Summary/Keyword: 자성재료

Search Result 398, Processing Time 0.027 seconds

A Study of High-Quality Factor Solenoid-Type RF Chip Inductor Utilizing Amorphous $Al_2O_3$ Core Material (비정질 $Al_2O_3$ 코아 재료를 이용한 Solenoid 형태의 고품질 RF chip 인덕터에 관한 연구)

  • Lee, Jae-Wook;Jung, Young-Chang;Yun, Eui-Jung;Hong, Chol-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.6
    • /
    • pp.34-42
    • /
    • 2000
  • Recently, there is a growing need to develope small-size RF chip inductors operating to GHz to realize high-performance, micro-fabricated wireless communication products. For the development of high-performance RF chip inductors, however, the ferrite-based chip inductors can not be used above 300MHz due to the limitation of the permeability of this material. In this work, small-size, high-performance RF chip inductors utilizing amorphous $Al_2O_3$ core material were investigated. Copper (Cu) with 40${\mu}m$ diameter was used as the coils and the chip inductor size fabricated in this work is $2.1mm{\times}1.5mm{\times}1.0mm$. The external current source was applied after bonding Cu coil leads to gold pads electro-plated on the bottom edges of a core material. The composition of core materials was measured using a EDX. High frequency characteristics of the inductance (L), quality factor (Q), and impedance (Z) of developed inductors were measured using an RF Impedance/Material Analyzer (HP4291B with HP16193A test fixture). The developed inductors have the self-resonant frequency (SRF) of 1 to 3.5 GHz and exhibit L of 22 to 150 nH. The L of the inductors decreases with increasing the SRF. The Z of the inductors has the maximum value at the SRF and the inductors have the quality factor of 70 to 97 in the frequency range of 500 MHz to 1.5 GHz.

  • PDF

MnIr Thickness Dependence of Torque Signals in CoFe/MnIr Thin Films (CoFe/MnIr 박막 재료에서 MnIr의 두께에 따른 토오크 신호 분석)

  • Kim, Dong Young;Yoon, Seok Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.5
    • /
    • pp.140-145
    • /
    • 2014
  • We analyzed the MnIr thickness dependence of torque signals measured in exchange coupled CoFe/MnIr ($t_{AF}$) bilayers. The measured torque signals were compared with calculated ones by Stoner-Wohlfarth model. The exchange coupling anisotropy $J_c$ was considered for the model calculation between ferromagnetic (F) and antiferromagnetic (AF) layers with uniaxial anisotropy constant of $K_F$ and $K_{AF}$, respectively. The rotational losses were appeared in the range of $0.5t_c$ < $t_{AF}$ < $t_c$ ($=J_c/K_{AF}$) by the unpinned AF layer. While, the unidirectional anisotropy ($J_k$) was caused by the pinned AF layer at $t_{AF}$ > $t_c$. The critical thickness of MnIr layer was $t_c$ = 3.4 nm in CoFe/MnIr bilayers. The rotational losses behavior as shown in $t_{AF}$ = 3 nm sample were explained by the random orientation of the easy axis of AF grains. The unidirectional anisotropy obtained from torque signal of $t_{AF}$ = 10 nm sample was $J_k=0.63J_c$. Thus, the unidirectional anisotropy can be enhanced up to $J_k=J_c$ by aligning the AF easy axis.

Electrodeposition Characteristics and Magnetic Properties of CoFeNi Thin Film Alloys

  • Song, Jae-Song;Yoon, Do-Young;Han, Choon;Kim, Dae-Heum;Park, Dyuk-Young;Myung, No-Sang
    • Journal of the Korean Electrochemical Society
    • /
    • v.5 no.1
    • /
    • pp.17-20
    • /
    • 2002
  • Various compositions of CoFeNi alloys have been electrodeposited in chloride bath and in sulfate bath, and evaluated for electrodeposition characteristics and magnetic properties. For electrodeposited CoFeNi thin film alloys, the increase of Fe content in the deposits from sulfate bath was considerably faster than those from chloride bath. The current efficiencies in sulfate bath showed observable decrease from $75\%\;to\;50\%$ while those in chloride bath showed no significant decrease. From the low coercivity of 3 Oe in the minimum and the higher squarenesses of the alloys from sulfate bath than those from chloride bath, the alloy at Co, Fe, and Ni contents of $80wt.\%,\;10wt.\%,\;and\;10wt.\%$ can be considered to be the best CoFeNi alloy in this research for the soft magnetic material.

Magnetic Bio-Sensor Using Planar Hall Effect (평면홀 효과를 이용한 자기 바이오센서)

  • Oh, Sun-Jong;Hung, Tran Quang;Kumar., S. Ananda;Kim, Cheol-Gi;Kim, Dong-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.5
    • /
    • pp.421-426
    • /
    • 2008
  • The magnetic bio-sensor used the PHR (planar hall resistance) effect generated by the free layer in spin-valve giant magnetoresistance structure of Ta/NiFe/CoFe/Cu/NiFe/IrMn/Ta. The PHR element with micrometer size was fabricated through the photolithograph and dry etching process. The PHR signal with magnetic field was measured under the conditions of with and without single magnetic bead. A single magnetic bead of diameter $2.8\;{\mu}m$ was successfully detected using the PHR sensor. Therefore, the high resolution PHR sensor can be applied to bio-sensor application utilizing the output voltage variation of the PHR signals in the presence and absence of a single magnetic bead.

Effects of Mn, Cr and Co on the Magnetic Properties of Fe-Ni Invar Alloys (Fe-Ni 인바합금의 자기적성질에 미치는 Mn, Cr 및 Co의 첨가효과)

  • 이종현;김희중;강일구;김학신
    • Journal of the Korean Magnetics Society
    • /
    • v.3 no.1
    • /
    • pp.7-12
    • /
    • 1993
  • The effects of Mn, Cr or Co addItion on the magnetic properties of Fe-Ni Invar alloys were investigated. The composition range of the three additives is up to 5wt%. In the temperature range of room temperature-$250^{\circ}C$, the variation of specific magnetization with the addition of Mn, Cr or Co in the Fe-Ni alloys except for 5wt% Co shows the phenomenon characteristics of the Invar effect, viz., the specific magnetization decreases very abrubtly with the temperature and the dependence of temperature on the specific magnetization is in the mixed form of $T^{3/2}$ and $T^{2}$. In the room temperature, the amount of increase in the specific magnetization, Curie temperature and coercivity is in order of Co > Cr > Mn. In the case of 5wt% Co an anomalous phenomena were observed due to the occurrance of ferromagnetic $\alpha$ phase which reduces the invar effect.

  • PDF

Analysis of Properties of Flake Sendust EM Wave Absorber according to Granularity (입도에 따른 Flake Sendust 전파 흡수체의 특성 분석)

  • Park, Soo-Hoon;Kim, Dong-Il;Choi, Dong-Han;Kim, Seong-Yeon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.9
    • /
    • pp.1051-1057
    • /
    • 2008
  • In this paper, we analyzed the characteristics of the EM wave absorber which was fabricated by using flake sendust (soft metal magnetic powder). The flake sendust was made of 3 different granularity by attrition mill. First, we have fabricated 3 kind of EM wave absorbers using the flake sendust and CPE(Chlorinated Polyethylene) and measured the S-parameters of the EM wave absorber. The complex relative permittivity and permeability were calculated from the measured data and the variations according to a change of granularity were researched. As a result, it was confirmed that the EM wave absorber using flake sendust with the $140{\mu}m$ average granularity has outstanding absorption ability in high frequency range(C band) for the reduction of eddy current loss(increase of permeability) and the increase of space charge polarization(increase of permittivity).

Evaluation Technology of Degradation of Metallic Alloy using Electrical Resistivity (전기비저항을 이용한 금속합금 열화도 평가기술)

  • Nahm, Seung-Hoon;Yu, Kwang-Min;Ryu, Jae-Cheon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.5
    • /
    • pp.532-541
    • /
    • 2001
  • Developments of nondestructive evaluation techniques for reduction of strength or toughness by aging of material have been carried out, and the method using electrical resistivity is one of them. In this study, to examine the application of electrical resistivity to the evaluation of degradation of metallic alloy, ten different non-magnetic materials were selected as test materials. Electrical resistivities measured by DC two-point probe method and those measured by non-contact type eddy current method were compared with each other. In addition, to examine the application possibility of four-point probe technology in field, the electrical resistivities for 1Cr-lMo-0.25V steel measured by DC two-point probe method and four-point probe method were compared with each other Differences between two measured values for the 1Cr-1Mo-0.25V steel were 0.6%. Therefore, the four-point probe method can be applied to the estimation of the degradation of metallic alloy. ect.

  • PDF

Characteristic of EP-MAP for Deburring of Microgroove using EP-MAP (전해-자기 복합 가공을 이용한 미세 그루브형상의 가공 특성에 관한 연구)

  • Kim, Sang Oh;Son, Chul Bae;Kwak, Jae Seob
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.3
    • /
    • pp.313-318
    • /
    • 2013
  • Magnetic abrasive polishing is an advanced deburring process for nonmagnetic materials and micropattern products that have non-machinability characteristics. Despite these advantages, there are some problems with using MAP for deburring. MAP has introduced geometric errors into microgrooves because of an over-cutting force caused by uncontrolled magnetic abrasives in the MAP tool. Thus, in this study, to solve this problem, an EP (electrolyte polishing)-MAP hybrid polishing process was developed for deburring microgrooves in an STS316 material. In addition, an evaluation of EP-MAP for the deburring of microgrooves was carried out by profiling the burrs. The results of the experiment showed geometric errors after the deburring process using MAP. However, in the case of EP-MAP, no geometric error was observed after the process because of the lower material removal rate in EP-MAP.

Dry Etching of NiFe, NiFeCo, and Ta in Cl2/Ar Inductively Coupled Plasma (Cl2/Ar 유도 결합 플라즈마를 이용한 NiFe, NiFeCo, Ta의 건식식각)

  • Ra, Hyun-Wook;Park, HyungJo;Kim, Ki Ju;Kim, Wan-Young;Hahn, Yoon-Bong
    • Korean Chemical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.76-79
    • /
    • 2005
  • Dry etching of NiFe, NiFeCo, and Ta for magnetic random access memory (MRAM) by inductively coupled plasmas (ICPs) of $Cl_2/Ar$ has been carried out. NiFe and NiFeCo showed maximum etch rates at a particular ICP source power, but the etch rate of Ta increased with the ICP source power. The etch rates of the magnetic thin films increased with the RF chuck power, but decreased with the operating pressure and the $Cl_2$ concentration. To avoid a corrosion problem by chlorine, the etched samples were rinsed with de-ionized water for 5 minutes after etching. The etch profile showed a clean and smooth surface at 50% $Cl_2$ concentration.

Feasibility Study of MR Elastomer-based Base Isolation System (MR 엘라스토머를 이용한 기초격리 시스템에 대한 타당성 연구)

  • Jang, Dong-Doo;Usman, Muhammad;Sung, Seung-Hoon;Moon, Yeong-Jong;Jung, Hyung-Jo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.6
    • /
    • pp.597-605
    • /
    • 2008
  • The feasibility study of a newly proposed smart base isolation system employing magneto-rheological elastomers(MREs) has been carried out. MREs belong to a class of smart materials whose elastic modulus or stiffness can be adjusted by varying the magnitude of the magnetic field. The base isolation systems are considered as one of the most effective devices for vibration mitigation of civil engineering structures such as bridges and buildings in the event of earthquakes. The proposed base isolation system strives to enhance the performance of the conventional base isolation system by improving the robustness of the system wide stiffness range controllable of MREs, which improves the adaptability and helps in better vibration control. To validate the effectiveness of the MRE-based isolation system, an extensive numerical simulation study has been performed using both single-story and five-story building structures employing base isolated devices under several historical earthquake excitations. The results show that the proposed system outperformed the conventional system in reducing the responses of the structure in all the seismic excitations considered in the study.