• Title/Summary/Keyword: 자동 제어

Search Result 3,255, Processing Time 0.025 seconds

Study of Quality Control of Traditional Wine Using IT Sensing Technology (IT 센싱 기술을 이용한 전통주 발효의 품질관리 연구)

  • Song, Hyeji;Choi, Jihee;Park, Chan-Won;Shin, Dong-Beom;Kang, Sung-Soo;Oh, Sung Hoon;Hwang, Kwontack
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.6
    • /
    • pp.904-911
    • /
    • 2015
  • The objective of this study was to investigate the quality characteristics of traditional wine using an radio-frequency identification (RFID) system annexed to a fermenter. In this study, we proposed an RFID-based data transmission scheme for monitoring fermentation of traditional alcoholic beverages. The pH, total acidity, total sugar, soluble sugar, free sugar, alcohol content, and organic acids of were investigated and subjected to fermentation of traditional alcoholic beverages three times. The pH ranged from 7.98, 7.95, and 7.68 at day 0, decreased drastically to 3.31~2.96 at day 2, and then slowly increased to the end point, finally reaching 3.34 at day 20. Acidity tended to increase quickly with time, especially for all samples after day 2. The fermentation environment induced a sudden increase acidity in reactants and indicated a low pH. The total sugars during fermentation quickly decreased to the range of 20.3, 22.43, and 19.2% at day 2, and the slope of reduction steadily decreased to 5.1, 6.1, and 4.8% at day 10. On the other hand, the alcohol content showed the reverse trend as total sugars. The alcohol content also showed the same pattern as total acids, showing the highest alcohol content of 17.3% (v/v) on day 20. In this study on traditional wine fermentation using an RFID system, we showed that pH, soluble sugar, and alcohol content can be adopted as key indicators for quality control and standardization of traditional wine manufacturing.

An Interdisciplinary Approach to the Human/Posthuman Discourses Emerging From Cybernetics and Artificial Intelligence Technology (4차 산업혁명 시대의 사이버네틱스와 휴먼·포스트휴먼에 관한 인문학적 지평 연구)

  • Kim, Dong-Yoon
    • Journal of Broadcast Engineering
    • /
    • v.24 no.5
    • /
    • pp.836-848
    • /
    • 2019
  • This paper aims at providing a critical view over the cybernetics theory especially of first generation on which the artificial intelligence heavily depends nowadays. There has been a commonly accepted thought that the conception of artificial intelligence could not has been possible without being influenced by N. Wiener's cybernetic feedback based information system. Despite the founder of contemporary cybernetics' ethical concerns in order to avoid an increasing entropy phenomena(social violence, economic misery, wars) produced through a negative dynamics of the western modernity regarded as the most advanced form of humanism. In this civilizationally changing atmosphere, the newly born cybernetic technology was thus firmly believed as an antidote to these vices deeply rooted in humanism itself. But cybernetics has been turned out to be a self-organizing, self-controlling mechanical system that entails the possibility of telegraphing human brain (which are transformed into patterns) through the uploading of human brain neurons digitalized by the artificial intelligence embedded into computing technology. On this background emerges posthuman (or posthumanism) movement of which concepts have been theorized mainly by its ardent apostles like N. K. Hayles, Neil Bedington, Laurent Alexandre, Donna J. Haraway. The converging of NBIC Technologies leading to the opening of a much more digitalizing society has served as a catalyst to promote the posthuman representations and different narratives especially in the contemporary visual arts as well as in the study of humanities including philosophy and fictional literature. Once Bruno Latour wrote "Modernity is often defined in terms of humanism, either as a way of saluting the birth of 'man' or as a way of announcing his death. But this habit is itself modern, because it remains asymmetrical. It overlooks the simultaneous birth of 'nonhumaniy' - things, or objects, or beasts, - and the equally strange beginning of a crossed-out God, relegated to the sidelines."4) These highly suggestive ideas enable us to better understand what kind of human beings would emerge following the dazzlingly accelerating advancement of artificial intelligence technology. We wonder whether or not this newly born humankind would become essentially Homo Artificialis as a neuronal man stripping off his biological apparatus. However due to this unprecedented situation humans should deal with enormous challenges involving ethical, metaphysical, existential implications on their life.

Comparisons of Soil Water Retention Characteristics and FDR Sensor Calibration of Field Soils in Korean Orchards (노지 과수원 토성별 수분보유 특성 및 FDR 센서 보정계수 비교)

  • Lee, Kiram;Kim, Jongkyun;Lee, Jaebeom;Kim, Jongyun
    • Journal of Bio-Environment Control
    • /
    • v.31 no.4
    • /
    • pp.401-408
    • /
    • 2022
  • As research on a controlled environment system based on crop growth environment sensing for sustainable production of horticultural crops and its industrial use has been important, research on how to properly utilize soil moisture sensors for outdoor cultivation is being actively conducted. This experiment was conducted to suggest the proper method of utilizing the TEROS 12, an FDR (frequency domain reflectometry) sensor, which is frequently used in industry and research fields, for each orchard soil in three regions in Korea. We collected soils from each orchard where fruit trees were grown, investigated the soil characteristics and soil water retention curve, and compared TEROS 12 sensor calibration equations to correlate the sensor output to the corresponding soil volumetric water content through linear and cubic regressions for each soil sample. The estimated value from the calibration equation provided by the manufacturer was also compared. The soil collected from all three orchards showed different soil characteristics and volumetric water content values by each soil water retention level across the soil samples. In addition, the cubic calibration equation for TEROS 12 sensor showed the highest coefficient of determination higher than 0.95, and the lowest RMSE for all soil samples. When estimating volumetric water contents from TEROS 12 sensor output using the calibration equation provided by the manufacturer, their calculated volumetric water contents were lower than the actual volumetric water contents, with the difference up to 0.09-0.17 m3·m-3 depending on the soil samples, indicating an appropriate calibration for each soil should be preceded before FDR sensor utilization. Also, there was a difference in the range of soil volumetric water content corresponding to the soil water retention levels across the soil samples, suggesting that the soil water retention information should be required to properly interpret the volumetric water content value of the soil. Moreover, soil with a high content of sand had a relatively narrow range of volumetric water contents for irrigation, thus reducing the accuracy of an FDR sensor measurement. In conclusion, analyzing soil water retention characteristics of the target soil and the soil-specific calibration would be necessary to properly quantify the soil water status and determine their adequate irrigation point using an FDR sensor.

Application of deep learning method for decision making support of dam release operation (댐 방류 의사결정지원을 위한 딥러닝 기법의 적용성 평가)

  • Jung, Sungho;Le, Xuan Hien;Kim, Yeonsu;Choi, Hyungu;Lee, Giha
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.spc1
    • /
    • pp.1095-1105
    • /
    • 2021
  • The advancement of dam operation is further required due to the upcoming rainy season, typhoons, or torrential rains. Besides, physical models based on specific rules may sometimes have limitations in controlling the release discharge of dam due to inherent uncertainty and complex factors. This study aims to forecast the water level of the nearest station to the dam multi-timestep-ahead and evaluate the availability when it makes a decision for a release discharge of dam based on LSTM (Long Short-Term Memory) of deep learning. The LSTM model was trained and tested on eight data sets with a 1-hour temporal resolution, including primary data used in the dam operation and downstream water level station data about 13 years (2009~2021). The trained model forecasted the water level time series divided by the six lead times: 1, 3, 6, 9, 12, 18-hours, and compared and analyzed with the observed data. As a result, the prediction results of the 1-hour ahead exhibited the best performance for all cases with an average accuracy of MAE of 0.01m, RMSE of 0.015 m, and NSE of 0.99, respectively. In addition, as the lead time increases, the predictive performance of the model tends to decrease slightly. The model may similarly estimate and reliably predicts the temporal pattern of the observed water level. Thus, it is judged that the LSTM model could produce predictive data by extracting the characteristics of complex hydrological non-linear data and can be used to determine the amount of release discharge from the dam when simulating the operation of the dam.

Analysis of Patient Effective Dose in PET/CT; Using CT Dosimetry Programs (CT 선량 측정 프로그램을 이용한 PET/CT 검사 환자의 예측 유효 선량의 분석)

  • Kim, Jung-Sun;Jung, Woo-Young;Park, Seung-Yong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.77-82
    • /
    • 2010
  • Purpose: As PET/CT come into wide use, it caused increasing of expose in clinical use. Therefore, Korea Food and Drug Administration issued Patient DRL (Diagnostic Reference Level) in CT scan. In this study, to build the basis of patient dose reduction, we analyzed effective dose in transmission scan with CT scan. Materials and Methods: From February, 2010 to March 180 patients (age: $55{\pm}16$, weight: $61.0{\pm}10.4$ kg) who examined $^{18}F$-FDG PET/CT in Asan Medical Center. Biograph Truepoint 40 (SIEMENS, GERMANY), Biograph Sensation 16 (SIEMENS, GERMANY) and Discovery STe8 (GE healthcare, USA) were used in this study. Per each male and female average of 30 patients doses were analyzed by one. Automatic exposure control system for controlling the dose can affect the largest by a patient's body weight less than 50 kg, 50-60 kg less, 60 kg more than the average of the three groups were divided doses. We compared that measured value of CT-expo v1.7 and ImPACT v1.0. The relationship between body weight and the effective dose were analyzed. Results: When using CT-Expo V1.7, effective dose with BIO40, BIO16 and DSTe8 respectably were $6.46{\pm}1.18$ mSv, $9.36{\pm}1.96 $mSv and $9.36{\pm}1.96$ mSv for 30 male patients respectably $6.29{\pm}0.97$ mSv, $10.02{\pm}2.42$ mSv and $9.05{\pm}2.27$ mSv for 30 female patients respectably. When using ImPACT v1.0, effective dose with BIO40, BIO16 and DSTe8 respectably were $6.54{\pm}1.21$ mSv, $8.36{\pm}1.69$ mSv and $9.74{\pm}2.55$Sv for 30 male patients respectably $5.87{\pm}1.09$ mSv, $8.43{\pm}1.89$ mSv and $9.19{\pm}2.29$ mSv for female patients respectably. When divided three groups which were under 50 kg, 50~60 kg and over 60 kg respectably were 6.27 mSv, 7.67 mSv and 9.33 mSv respectably using CT-Expo V1.7, 5.62 mSv, 7.22 mSv and 8.91 mSv respectably using ImPACT v1.0. Weight and the effective dose coefficient analysis showed a very strong positive correlation(r=743, r=0.693). Conclusion: Using such a dose evaluation programs, easier to predict and evaluate the effective dose possible without performing phantom study and such dose evaluation programs could be used to collect basic data for CT dose management.

  • PDF