• Title/Summary/Keyword: 자동제어 실험

Search Result 484, Processing Time 0.036 seconds

Development of the Measuring System for Automation of Hydroponics (수경재배 자동화를 위한 계측시스템의 개발)

  • 김성은;김영식;김승우
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.210-214
    • /
    • 1996
  • The measuring system was developed for automation of hydroponic culture. It runs in Windows 3.1 and 95. Main window contains greenhouse screen and menu bars such as system setting, sensor calibration, greenhouse status, actuator control, file management, view, and help. Users can use pop-up menu, tool bar and status bat as well as menu bar for manipulation. Especially it was designed to retain flexibility for researchers, who changed detecting sensors frequently. Users can change storage intervals of files, of which 3 types were prepared to use in other software like as statistical programs, graphic programs and/or spread sheets. This system was adopted to deep flow culture system and evaluated to be appropriate for any kind of hydroponic systems.

  • PDF

Dynamic Shutdown at Server Power Mode Control for Saving Energy in a Server Cluster Environment (서버 클러스터 환경에서 에너지 절약을 위한 서버 전원 모드 제어에서 동적 종료)

  • Ham, Chihwan;Kim, Hoyeon;Kim, Dongjun;Kwak, Hukeun;Kwon, Huiung;Kim, Youngjong;Chung, Kyusik
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.04a
    • /
    • pp.79-82
    • /
    • 2012
  • 기존의 서버 전원 모드 제어에는 서버를 Off할 때 정적 종료 방식을 사용하는 관계로 서버가 사용자 요청을 모두 처리하는 최적의 종료 시간을 찾는데 시간이 많이 걸리는 단점을 가진다. 이 시간이 짧게 되면 사용자 QoS를 보장할 수 없고, 반대로 이 시간이 길게 되면 전력 절감을 기대할 수 없다. 본 논문에서는 정적 종료 방식의 단점을 극복하는 동적 종료 방식을 제안한다. 제안된 방식은 최적의 종료 시간을 찾을 필요 없이 각 서버가 사용자의 요청을 모두 처리하였을 때 자동적으로 서버를 Off한다. 제안된 방법은 최적의 시간을 자동적으로 찾아내기 때문에 사용자 QoS를 보장하고, 전력을 절감한다. 실험은 30대의 PC 클러스터를 이용하여 수행되었고, 실험을 통하여 제안하는 동적 종료 방법이 기존의 정적 종료 방법에 비해 운영자의 수고 없이 자동적으로 전력 절감 및 사용자 QoS에 기여함을 확인하였다.

Series Compensated AC Voltage Regulator using AC chopper with Auxiliary Transformer (교류쵸퍼와 보조변압기를 사용한 직렬보상형 교류전압제어장치)

  • 류홍제;김종수;임근희
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.5
    • /
    • pp.463-467
    • /
    • 2003
  • This paper describes an AC voltage regulator using AC chopper and auxiliary transformer which is series connected with main input. It has many advantages such as fast voltage control, high efficiency and low THD. A detail study of step down AC voltage regulator is described and two kinds of novel step-up/down voltage regulator for AVR application are proposed. The operation principle and PWM method of the proposed regulator are described. Experimental results show that it can be used as AC voltage regulator for special purpose very efficiently.

Error-Based Iterative Feedgack Tuning with Application to Optical Disk Drive (광디스크 드라이브의 제어를 위한 에러기반 반복 피드백 게인 조절 방법에 관한 연구)

  • Seo, Dong-Hyeok;Kim, Hong-Rok;Jang, Si-Young;Suh, Il-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2179-2181
    • /
    • 2004
  • Model-free Method들 중에 반복 피트백 조절 알고리즘(Iterative Feedback Tuning, IFT)는 특정한 성능지수를 정의하고, 이를 최소화하도록 제어기의 게인들을 조절하는 방법을 제시하였다. PID와 같은 고전적인 제어이론에 근거한 제어기 설계 과정과는 달리, IFT 알고리즘은 반복 실험을 통해 성능지수의 Gradient를 구하여 이로부터 필터 게인들 조정하는 방법을 채택하고 있다. 수학적 증명과 실험적 실증을 통하여 IFT의 수렴성과 유용성이 보여짐에도 불구하고 IFT 알고리즘의 한계점은 단일 성능지수의 사용이라는데 있다. 이를 개선하기 위해서는 단일 제어 목적을 위한 단일 성능지수의 사용이 아닌 복수의 제어 목적을 위한 복수의 성능지수의 사용이 필요하다. 본 논문에서는 두 개의 성능지수를 가지는 IFT를 이용해서 위상 여유가 크고, 대역폭이 넓은 제어기를 설계하기 위해서 제어기 게인을 자동 조절하는 알고리즘을 제안하고 ODD에서 사용되는 플랜트에 적용한 모의실험을 통하여 그 유용성을 보였다.

  • PDF

Experimental Test Time Reduction Method for Step Responses Using the Time-Optimal Control Technique (시간최적제어 기법을 이용한 계단응답 실험시간 단축 방법)

  • Lee, Jietae
    • Korean Chemical Engineering Research
    • /
    • v.58 no.2
    • /
    • pp.190-196
    • /
    • 2020
  • The step to obtain a process dynamic model through process experiments is very important because it needs times and expenditures. Step response method is one of the standard methods to have long been used for understanding process dynamics, obtaining dynamical models and designing control systems. For the step response, it is usually required to measure process output for a step input change in the open-loop manner. Its disadvantage criticized is the long open-loop operation. For this, a method based on the time-optimal control technique to minimize the test time for obtaining the step response has been recently presented. However, the method requires iterative computations for the minimization of test times. Here, a method where iterative computations are not required is proposed. Simulation results are presented to show that test times to obtain step responses are reduced considerably and an autotuning method based on the proposed method is compared with the relay feedback autotuning method accepted widely for the autotuning of controllers.

Ground Test of the Flight Control System Using PC104 (PC104를 이용한 비행제어 시스템 개발을 위한 지상시험)

  • Heo, Chi-Hoon;Roh, Min-Shik;Cho, Kyeum-Rae;Lee, Dae-Woo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.5
    • /
    • pp.452-459
    • /
    • 2007
  • This paper presents the flight control system using a PC104 with GPS and IMU. This System includes an Auto/Manual conversion module by PIC16 for safety, and homing type guidance algorithm to flight toward a scheduled target. We verify the performance of the flight control system via ground test, and present the possibility of application into UAV control system via comparison with the commercial system.

Model Based Design and Validation of Vehicle Transmission Control Unit (차량용 변속기 제어 장치의 모델기반 설계 및 검증)

  • Jeong, Byeong-Guk;Hwang, Seon-Hwan;Lee, Jae-Seok;Ko, Hee-Young
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.157-158
    • /
    • 2015
  • 본 논문에서는 Matlab/Simulink와 Renesas사의 프로세서를 이용하여 차량용 변속 제어를 위한 모델기반 시스템을 구현하였다. 차량용 변속 제어를 위한 전체 시스템 모델은 Simulink와 Renesas사의 Real Time Interface(RTI)를 이용하여 구현한 후에 실험을 수행하였다. Matlab과 Renesas 제어보드의 컴파일러가 설계된 변속기 제어 모델의 C-소스 파일과 Object 파일을 자동으로 생성시켜주기 때문에 사용자에 의한 추가적인 프로그램의 Coding 없이 실제 시스템의 시뮬레이션과 실험을 동시에 수행할 수 있다.

  • PDF

Instruction Tuning for Controlled Text Generation in Korean Language Model (Instruction Tuning을 통한 한국어 언어 모델 문장 생성 제어)

  • Jinhee Jang;Daeryong Seo;Donghyeon Jeon;Inho Kang;Seung-Hoon Na
    • Annual Conference on Human and Language Technology
    • /
    • 2023.10a
    • /
    • pp.289-294
    • /
    • 2023
  • 대형 언어 모델(Large Language Model)은 방대한 데이터와 파라미터를 기반으로 문맥 이해에서 높은 성능을 달성하였지만, Human Alignment를 위한 문장 생성 제어 연구는 아직 활발한 도전 과제로 남아있다. 본 논문에서는 Instruction Tuning을 통한 문장 생성 제어 실험을 진행한다. 자연어 처리 도구를 사용하여 단일 혹은 다중 제약 조건을 포함하는 Instruction 데이터 셋을 자동으로 구축하고 한국어 언어 모델인 Polyglot-Ko 모델에 fine-tuning 하여 모델 생성이 제약 조건을 만족하는지 검증하였다. 실험 결과 4개의 제약 조건에 대해 평균 0.88의 accuracy를 보이며 효과적인 문장 생성 제어가 가능함을 확인하였다.

  • PDF

A Study on Maintaining Control of Tension for a Catenary's Cable (현수형 가선 케이블의 정장력 유지제어에 관한 연구)

  • Yoon, Jung-Hwan;Hong, Soon-Ill;Kim, Chunl-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2339-2341
    • /
    • 2000
  • 본 논문은 제어대상인 현수형 케이블의 수학적 모델을 작성하고 이것에 장력을 발생하는 교류서보 전동기의 수학적 모델을 구하였다. 제어 방법은 제어대상의 동적 모델이 비선형 시변계이기 때문에 강인성이 있는 퍼지제어를 적용하고 차대가 움직이기 시작할 때 발생하는 오버슈트을 억제하기 위해서 피드포워드제어를 채택한다. 케이블의 동적 모델에 기초하여 퍼지제어기와 피드포워드제어를 도입하여 시스템을 구성하고 시뮬레이션 실험에 의해 그 유효성을 평가하였다. 현재 로프제조 공정, 전차 트롤리선 가설공사는 장력의 제어가 필요하지만 거의 수동으로 행하고 있는 실정이고 제품의 균질성과 생산성 향상을 위하여 제조 공정의 자동화가 필요하다. 따라서 전차의 트롤리선 가설공사는 케이블을 탑재한 차대가 주행하면서 드럼에 감긴 케이블을 풀어주고 양단의 장력을 일정히 유지하도록 조절할 필요가 있다. 그러나 전기공사에서 시행하고 있는 송 배전 선로의 전력케이블 가선공사나 전차 트롤리선 가설공사는 수동으로 하고 있는 실정이고 이것의 자동화기계가 필요하다. 따라서 본 연구의 목적은 현수형 가선 케이블 가설장치의 자동화이다. 본 연구에서는 제어대상인 현수형 케이블의 수학적 모델을 작성하고 이것에 장력을 발생하는 교류서보 전동기의 수학적 모델을 구하였다. 제어 방법은 제어대상의 동적 모델이 비선형 시변계이기 때문에 강인성이 있는 퍼지제어를 적용하고 차대가 움직이기 시작할 때 발생하는 오버슈트를 억제하기 위해서 피드포워드제어를 채택한다. 케이블의 동적 모델에 기초하여 퍼지제어기와 피드포워드제어를 도입하여 시스템을 구성하고 시뮬레이션 실험에 의해 그 유효성을 평가하였다.

  • PDF

Secondary Path Estimation for Stable Active Noise Control (안정한 능동소음제어를 위한 2차경로 추정기법)

  • Seo, Sung-Dae;Ahn, Dong-Jun;Nam, Hyun-Do
    • Proceedings of the KIEE Conference
    • /
    • 2008.04a
    • /
    • pp.121-122
    • /
    • 2008
  • 본 논문에서는 2차 경로의 추정을 통하여 안정성이 강화된 능동소음 제어 시스템을 제안한다. LMS 알고리즘은 구조가 단순하고 계산량이 적은 장전이 있지만, 광대역 소음원에 적용할 경우 수렴 성능이 좋지 않은 단점이 있으며, 2차 경로 및 소음원 입력의 파워가 시변 할 경우 적응 알고리즘의 안정성이 약화되는 문제점이 발생한다. 본 논문에서는 지속적으로 누적 오차를 추적하여 일정 값 이상으로 증가하면 자동적으로 2차 경로 전달함수를 새로 추정하는 자동오프라인 추정 기법을 제안하였다. 공조용 덕트에 광대역 소음을 적용하여 제안된 능동소음제어 시스템을 실험을 수행한 결과 우수한 특성을 얻었다.

  • PDF