• Title/Summary/Keyword: 자기 진단 신호

Search Result 163, Processing Time 0.027 seconds

The usefulness of the contrast agent high in gadolinium for the magnetic resonance shoulder arthrography (자기공명 견관절조영검사 시 고함유량 가돌리늄 조영제의 유용성)

  • Na, Sa-Ra;Kim, Yoon-Shin;Choi, Kwan-Woo;Lee, Ho-Beom;Son, Soon-Yong;Min, Jung-Whan;Lee, Joo-Ah;Ma, Sang-Chull;Lee, Jong-Seok;Yoo, Beong-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.2199-2206
    • /
    • 2014
  • This research, used an contrast agent, which weighs about 1mmol/mL, of twice as much amount of gadolinum, per unit, for the test of magnetic-resonance shoulder arthrography. the reasearch which was carried out from January, of the year 2012 to August of the year 2013. consisted, of target of 41, patients including 20 ones, of whom an original, contrast agent of amount of 0.5mmol/mL, 21, ones of whom, a new, of amount of 1mmol/mL was used on, were the test target, in order to figure out the differences, according to the amount of gadolinum, according to the test results, the SNR of the contrast agent, of amount of 1mmol/mL, which is of high amount of gadolinum, was noticeably higher than the one of amount of 0.5mmol/mL(the percentage of joint space 38.01%, the supraspinous muscle 8.40%, head of humerus 12.78%). and CNR of the contrast agent, of amount of 1mmol/mL, which is of high amount of gadolinum, was higher than the one of amount of 0.5mmol/mL(the percentage of joint space and supraspinous muscle 48.96%, the one of joint space and head of humerus 42.00%). In conclusion, one of the methods of increasing the reducing effect of T1, is to use contrast agent of amount of 1mmol/mL, in order to increase the reducing effect of T1, acquire the visual of high testing quality.

The clinical usefulness of fat suppression by chemical shift selective(CHESS) pulse in MRI (MRI에서 화학적 이동 선택(CHESS) pulse에 의한 지방소거의 임상적 유용성)

  • Han, Man-Seok;Yang, Hae-Sool;Jin, Kyung-Soo;Eo, Ik-Soo;Cho, Dong-Heon
    • The KIPS Transactions:PartB
    • /
    • v.14B no.6
    • /
    • pp.431-436
    • /
    • 2007
  • Magnetic Resonance Imaging(MRI) has chemical shift phenomenon between fat and water, and the phenomenon has influence on structure enclosed by fat. Strong signals emitted from fat often generate false artefact, which reflects the importance of fat suppression techniques. There have been a number of researches on fat suppression techniques, but using fat suppression method alone in MRI can cause difficultproblems in diagnosis. This paper aims to study a fat suppression method by Chemical Shift Selective saturation(CHESS). This research describes the theoretical background and the experiment on water and fat phantom with MR instruments. In the experiment, CHESS pulse was designed by utilising Matlap program, and the pulse diagram was generated for the Pre-saturation process. The experiment using water and fat phantom was applied to C-spine, L-spine and Breast, and produced successful fat suppression results. This experiment has proved that the CHESSpulse fat suppression is a very helpful technique in diagnosing medical imaging. This method is a robust and useful technique for both clinical and basic investigators..(Experiment with Chungnam national university hospital G.E 1.5T MR)

Emotion-on-a-chip(EOC) : Evolution of biochip technology to measure human emotion (감성 진단칩(Emotion-on-a-chip, EOC) : 인간 감성측정을 위한 바이오칩기술의 진화)

  • Jung, Hyo-Il;Kihl, Tae-Suk;Hwang, Yoo-Sun
    • Science of Emotion and Sensibility
    • /
    • v.14 no.1
    • /
    • pp.157-164
    • /
    • 2011
  • Emotion science is one of the rapidly expanding engineering/scientific disciplines which has a major impact on human society. Such growing interests in emotion science and engineering owe the recent trend that various academic fields are being merged. In this paper we propose the potential importance of the biochip technology in which the human emotion can be precisely measured in real time using body fluids such as blood, saliva and sweat. We firstly and newly name such a biochip an Emotion-On-a-Chip (EOC). EOC consists of biological markers to measure the emotion, electrode to acquire the signal, transducer to transfer the signal and display to show the result. In particular, microfabrication techniques made it possible to construct nano/micron scale sensing parts/chips to accommodate the biological molecules to capture the emotional bio-markers and gave us a new opportunities to investigate the emotion precisely. Future developments in the EOC techniques will be able to help combine the social sciences and natural sciences, and consequently expand the scope of studies.

  • PDF

Imaging of Sequestered Lumbar Discs (요추 분리추간판의 영상 소견)

  • Gangwon Jeong;Heecheol Park;Sun Joo Lee;Dae-Hyun Park;Sung Hwa Paeng;Eugene Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.3-23
    • /
    • 2024
  • Intervertebral disc herniation is frequently encountered in radiological practice. Sequestered disc herniation occurs when the disc material undergoes degeneration and completely loses continuity with the parent nucleus pulposus. Sequestered discs can reside within and outside the spinal canal, exerting a mass effect on adjacent structures, compressing nerve pathways, and eliciting a range of clinical symptoms. In particular, sequestered discs within the dura cannot be identified without durotomy. Therefore, precise preoperative localization is crucial for surgical planning. On MRI, the signal intensity of the sequestered disc may vary due to independent degeneration processes. Additionally, most sequestered disc fragments show varying degrees of peripheral enhancement depending on the degree of angiogenesis and granulation around the isolated tissue. In this article, we review various imaging findings and the location of the sequestered disc to provide patients with an accurate diagnosis and appropriate treatment direction.

Glomus Tumor in Soft Tissue (연부 조직에 발생한 사구종)

  • Kim, Do-Yeon;Lee, Soo-Hyun;Kim, Min-Ju;Shin, Kyoo-Ho
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.15 no.1
    • /
    • pp.34-43
    • /
    • 2009
  • Purpose: Glomus tumors are rare benign vascular tumors, usually located in the skin or soft tissue of extremities. Approximately 30-50% of glomus tumors occur in subungal area, but glomus tumors have been described in every location even where glomus bodies are not or rarely present. The purpose of this study was to identify clinical, histologic and MRI characteristics of soft tissue glomus tumor. Materials and Methods: Between 1993 and 2008, eight patients underwent surgery of soft tissue Glomus tumor at our institution. Exclusion criteria were patients with Glomus tumors in digits, stomach, trachea and glomus tympanicum. We analyzed medical records, interviews, physical examinations, MR findings and histolocial types retrospectively. Results: There were four men and four women. The mean age was fourty-seven years. The mean prevalence time was eight-point-nine years. In the classic triad of symptoms, all eight patients had pain and tenderness. Two patients complained of cold sensitivity. Two showed skin color changes. After surgery, two showed symptom improvement (VAS $9^{\circ}{\rightarrow}8$, $8^{\circ}{\rightarrow}5$) and?six showed complete disappearance of symptoms. Slightly symptom improvemented (VAS $9^{\circ}{\rightarrow}8$) one had additional surgery two times after first surgery due to relapse/remaining Glomus tumor. The mean size was 13.9 mm. In histology, six were 'solid glomus tumor', one was a mixture of 'solid glomus tumor' and 'lomangioma' and one was 'malignant glomus tumor'. MR findings showed isointense signal on T1 image, high signal on T2 image and strong enhancement on the Gadolinium enhanced image. Conclusion: Glomus tumor has low recurrence rate and malignant change, rapid diagnosis and surgical excision is critical in treatment to prevent unnecessary pain of patient.

  • PDF

Outcome of LINAC Radiosurgery for a Cavernous Angioma (해면상혈관종에 대한 선형가속기를 이용한 고선량 정위 방사선수술의 임상경험)

  • Hong Semie;Chie Eui Kyu;Park Suk Won;Kim Il Han;Ha Sung Hwan;Park Charn Il
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.107-111
    • /
    • 2003
  • Purpose: To establish the role of stereoactic radiosurgery using a linear accelerator for the treatment of patients with cavernous angloma. Materials and Methods: Between February 1995 and May 1997, 11 patients with cavernous angioma were treated with stereotactic radiosurgery using a linear accelerator. Diagnoses were based on the magnetic resonance imaging in 8 patients, and the histological in 3. The vascular lesions were located on the brainstem (5 cases), cerebellum (2 cases) thalamus (1 case) and cerebrum (3 cases). The clinical presentation at onset included previous intracerebral hemorrhages (9 cases) and seizures (2 cases). All patients were treated with a a linac-based radiosurgery. The median dose of radiation delivered was 16 Gy ranging from 14 to 24 Gy, which was typically proscribed to the 80$\%$ isodose surface (range 50 $\~$ 80$\%$), corresponding to the periphery of the lesion with a single isocenter. Ten patients were followed-up. Results: The median follow-up was 49 months ranging from 8 to 73 months, during which time two patients developed an intracerebral hemorrhage, 1 at 8 months, with the other at 64 months post radiosurgery. One patient developed neurological deficit after radiosurgery, and two developed an edema on the T2 weighted images of the MRI surrounding the radiosurgical target. Conclusion: The use of stereotactic radiosurgery in the treatment of a cavernous angioma may be effective in the prevention of rebleedlng, and can be safely delivered. However, a longer follow-up period will be required.

Measurement of Regional Cerebral Blood Volume in Normal Rabbits on Perfusion-weighted MR Image (MR 관류강조영상에서 정상 가토의 국소 뇌혈류량 측정)

  • 박병래;예수영;나상옥;김학진;이석홍;전계록
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.100-106
    • /
    • 2000
  • Purpose : To evaluate the usefulness of cerebral blood flow measurement applied to perfusion weighted image with short-scan time single shot gradient echo-planar technique in measuring cerebral blood volume(rCBV) of normal rabbits. Materials and methods : With 2.1-3.6 kg weighted rabbits, image is acquired when they are in supine position in children positioner. Perfusion weighted image is acquired to 44 seconds per 1 second successively. After 4 seconds later, Gd-DTPA 2ml are injected into int. jugular vein with 2 ml per second and normal saline is also injected after that. Same technique is applied 2 times per 30 minites in same rabbit. After Image is obtained in two part of cerebral cortex at vertex, convexity, in one of basal ganglia with choosing about $3-5{\textrm{mm}^2}$ areas. Curve of signal intensity changes in time sequence is drawn. After this images are transmitted by PC and software IDL, regional cerebral blood volume is measured with imaging processing program made by us. Results : With 22 of 24 rabbits, satisfactory 1-2 signal intensity versus time curve is made. Cerebral blood capacity and contrast media stay time (ST) is measured in two cerebral cortex and basal ganglia refering in parietal cerebral cortex. Mean focal cerebral blood flow capacity ratio in cortex was $0.97{\pm}0.35$ and in basal ganglia, $0.99{\pm}0.37$, mean contrast media stay time in cortex was $9.83{\pm}1.63$ sec and in basal gaiglia, $9.42{\pm}1.14$ sec, but there was no statistically significant difference between two areas ($\rho$=0.05). Conclusion : In cerebral cortex and basal ganglia, there is no difference in mean focal blood volume and mean contrast stay time. Therefore, PWI is useful in cerebral blood flow and early diagnosis, prognosis of cerebral ischemic disease. Hereafter, it is helpful in analysing cerebral blood flow changes with comparison difference in rCBV between normal tissue and ischemic tissue, and that with DWI finding in infarcted patient.

  • PDF

A Study on Usefulness of Specific Agents with Liver Disease at MRI Imaging: Comparison with Ferucarbotran and Gd-EOB-DTPA Contrast Agents (간 병변 특이성 조영제 자기공명영상에 대한 연구: Ferucarbotran과 Gd-EOB-DTPA 조영제의 비교)

  • Lee, Jae-Seung;Goo, Eun-Hoe;Park, Cheol-Soo;Lee, Sun-Yeob;Choi, Yong-Seok
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.235-243
    • /
    • 2009
  • The purpose of this experiment is to know the relation of the detection and characterization of liver's diseases as comparison of finding at MR imaging using a Ferucarbotran (SPIO) and Gd-EOB-DTPA (Primovist) agents in diffuse liver disease. A total of 50 patients (25 men and 25 women, mean age: 50 years) with liver diseases were investigated at 3.0T machine (GE, General Electric Medical System, Excite HD) "with 8 Ch body coil for comparison of diseases and contrast's uptake relation, which used the LAVA, MGRE." All images were performed on the same location with before and after Ferucarbotran and Gd-EOB-DTPA administrations (p<0.05). Contrast to noise ratio of Ferucarbotran and Gd-EOB-DTPA in the HCC were $3.08{\pm}0.12$ and $7.00{\pm}0.27$ with MGRE and LAVA pulse sequence, $3.62{\pm}0.13$ and $2.60{\pm}0.23$ in the hyper-plastic nodule, $1.70{\pm}0.09$ and $2.60{\pm}0.23$ in the meta, $2.12{\pm}0.28$ and $5.86{\pm}0.28$ in the FNH, $4.45{\pm}0.28$ and $1.73{\pm}0.02$ in the abscess and ANOVA test was used to evaluate the diagnostic performance of each disease (p<0.05). In conclusions, two techniques were well demonstrated with the relation of the detection and characterization of liver's diseases.

  • PDF

Tc-99m ECD Brain SPECT in MELAS Syndrome and Mitochondrial Myopathy: Comparison with MR findings (MELAS 증후군과 미토콘드리아 근육병에서의 Tc-99m ECD 뇌단일 광전자방출 전산화단층촬영 소견: 자기공명영상과의 비교)

  • Park, Sang-Joon;Ryu, Young-Hoon;Jeon, Tae-Joo;Kim, Jai-Keun;Nam, Ji-Eun;Yoon, Pyeong-Ho;Yoon, Choon-Sik;Lee, Jong-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.6
    • /
    • pp.490-496
    • /
    • 1998
  • Purpose: We evaluated brain perfusion SPECT findings of MELAS syndrome and mitochondrial myopathy in correlation with MR imaging in search of specific imaging features. Materials and Methods: Subjects were five patients (four females and one male; age range, 1 to 25 year) who presented with repeated stroke-like episodes, seizures or developmental delay or asymptomatic but had elevated lactic acid in CSF and serum. Conventional non-contrast MR imaging and Tc-99m-ethyl cysteinate dimer (ECD) brain perfusion SPECT were Performed and imaging features were analyzed. Results: MRI demonstrated increased T2 signal intensities in the affected areas of gray and white matters mainly in the parietal (4/5) and occipital lobes (4/5) and in the basal ganglia (1/5), which were not restricted to a specific vascular territory. SPECT demonstrated decreased perfusion in the corresponding regions of MRI lesions. In addition, there were perfusion defects in parietal (1 patient), temporal (2), and frontal (1) lobes and basal ganglia (1) and thalami (2). In a patient with mitochondrial myopathy who had normal MRI, decreased perfusion was noted in left parietal area and bilateral thalami. Conclusion: Tc-99m ECD SPECT imaging in patients with MELAS syndrome and mitochondrial myopathy showed hypoperfusion of parieto-occipital cortex, basal ganglia, thalamus and temporal cortex, which were not restricted to a specific vascular territory. There were no specific imaging features on SPECT. The significance of abnormal perfusion on SPECT without corresponding MR abnormalities needs to be evaluated further in larger number of patients.

  • PDF

Usefulness of High-B-value Diffusion - Weighted MR Imaging for the Pre-operative Detection of Rectal Cancers (B-values 변환 자기공명영상: 국소 직장암 수술 전 검출을 위한 적합한 b-value 유용성)

  • Lee, Jae-Seung;Goo, Eun-Hoe;Lee, Sun-Yeob;Park, Cheol-Soo;Choi, Ji-Won
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.683-690
    • /
    • 2009
  • The purpose of this study is to evaluate the usefulness of high-b-values diffusion weighted magnetic resonance imaging for the preoperative detection of focal rectum cancers. 60patients with diffusion weighted imaging were evaluated for the presence of rectal cancers. Forty were male and twenty were female, and their ages ranged from 38 to 71 (mean, 56) years. Used equipment was 1.5Tesla MRI((GE, General Electric Medical System, Excite HD). Examination protocols were used the fast spin echo T2, T1 weighted imaging. All examination protocols were performed by the same location with diffusion weighted imaging for accuracy detection. The b-values used in DWI were 250, 500, 750, 1000. 1500, 2000$(s/mm^2)$. The rectum, bladder to tumor contrast-to-noise ratio (CNR) of MR images were quantitativlely analyzed using GE software Functool tool, four experienced radiologists and three radiotechnologists qualitatively evaluated image quality in terms of image artifacts, lesion conspicuity and rectal wall. These data were analysed by using ANOVA and Freedman test with each b-value(p<0.05). Contrast to noise ratio of rectum, bladder and tumor in b-value 1000 were 27.21, 24.44, respectively(p<0.05) and aADC value was $0.73\times10^{-3}$. As a qualitative analysis, the conspicuity and discrimination from the rectal wall of lesions were high results as $4.0\pm0.14$, $4.4\pm0.16$ on b-value 1000(p<0.05), image artifacts were high results as $4.8\pm0.25$ on b-value 2000(p<0.05). In conclusion, DWI was provided useful information with depicting the pre-operative detection of rectal cancers, High-b-value 1000 image was the most excellent DWI value.