• Title/Summary/Keyword: 자기호흡

Search Result 96, Processing Time 0.035 seconds

Diagnostic Accuracy and Evaluation of Myocardial Viability by Cardiac Magnetic Resonance Imaging in Acute Myocardial Infarction: A Comparison with Thallium-201 Myocardial SPECT (급성심근경색증에서의 심장자기공명영상술의 진단 정확도와 심근 생존력 평가: TI-201 심근관류 SPECT와의 비교)

  • Kim Hye-seon;Park Dong Woo;Kim Yongsoo;Kim Young-sun;Choi Yo Won;Jeon Seok Chul;Seo Heung Suk;Hahm Chang Kok;Kim Soon Kil;Ahn You hern;Choi Yoon Young;Park Choong-Ki
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.100-107
    • /
    • 2003
  • Purpose : To assess the usefulness of cardiac MR imaging (MRI) in the diagnosis of acute myocardial infarction and in the assessment of myocardial viability in comparision with T1-201 SPECT. Materials and Methods : We retrospectively studied 17 patients who complained of chest pain and dyspnea with cardiac MRI . The patients were evaluated for the presence or absence of high signal intensity on T2-weighted image (T2wI), abnormal wall motion on 2D-FIESTA, perfusion defect on Gd-DTPA enhanced T1WI, and delayed myocardial enhancement on 15-minutes delay Gd-DTPA enhanced T1WI. The results were correlated with the images on T1-201 SPECT, taken at rest and stress, through which reversibility of perfusion defect was assessed. Results : Both cardiac MRI and T1-201 SPECT proved to be useful methods for diagnosing acute myocardial infarction. In order of decreasing correspondence, T2WI, T1-201 SPECT, delayed enhancement study, and wall motion images all showed significant statistical correlation with the clinical diagnosis of myocardial infarction. Perfusion MRI, on the other hand, showed no significant statistical difference was found between T1-201 SPECT and cardiac MRI. The results on T2WI showed high accordance with those on Tl-201 SPECT, while delayed myocardial enhancement and wall motion studies showed no agreement with Tl-201 SPECT. Conclusion : Cardiac MRI is useful method for diagnosis of acute myocardiac infarction. With respect to the assessment of myocardial viability, the results obtained on cardiac MRI showed high agreement with those on Tl-201 SPECT. However, further study is necessary at this point for standardization and establishment of the methods for assessing myocardial viability on cardiac MRI.

  • PDF

Three Cases of Mitochondrial Disorders in the Neonatal Period (신생아기에 진단된 미토콘드리아 질환 3례)

  • Kim, Yoon-Hee;Lee, Young-Mock;Namgung, Ran;Kim, Jeong-Eun;Lee, Soon-Min;Park, Kook-In;Kim, Se-Hoon;Lee, Jin-Sung
    • Neonatal Medicine
    • /
    • v.17 no.2
    • /
    • pp.254-261
    • /
    • 2010
  • Little is known about neonatal mitochondrial disease, though mitochondrial metabolic disorders may often present in the neonatal period because of the high energy requirement of neonate. In newborn period, common presentations are not specific and the disease course may be rapid and fatal. In this study, we report three cases of neonatal mitochondrial disease. The first case was strongly suspected because of sudden seizure and mental change with severe lactic acidosis, and multiorgan failure. Plasma lactate/pyruvate (L/P) ratio was increased to 55.6 with marked lactic aciduria and increased plasma alanin up to 2,237 nmol/mL. In the second patient, a peritoneal dialysis was performed for acute adrenal and renal failure, but metabolic acidosis persisted. Plasma L/P ratio was increased to 23.9, and MRC I (mitochondrial respiratory chain defect) was diagnosed through the enzymatic analysis of the muscles. The third case showed repetitive episode of lactic acidosis during the first two months of life, hypotonia, failure to thrive and feeding difficulties. We found markedly increased cerebrospinal fluid L/P ratio up to 57 though plasma L/P ratio(19.4) was borderline with increased plasma lactate. The lactate peak was prominent in brain magnetic resonance spectroscopy (MRS). MRC II was confirmed through muscle biopsy. Plasma lactate level and lactate peak of brain MRS were normalized after conservative treatment.

Factors Affecting the Perception, Knowledge, and Preventive Behaviors of Chronic Pulmonary Disease Patients on Particulate Matter (만성호흡기질환자의 미세먼지에 대한 인식, 지식, 예방행위와 관련 요인)

  • Bang, So-Hee;Hwang, Tae-Yoon
    • Journal of agricultural medicine and community health
    • /
    • v.46 no.1
    • /
    • pp.1-11
    • /
    • 2021
  • Objectives: This research aimed to identify the level of perception, knowledge, preventive behavior, and factors affecting preventive behavior of patients with asthma and chronic obstructive pulmonary disease against particulate matter. Methods: This research was a descriptive survey research, and the subjects were chronic pulmonary disease patients over the age of 19 and under 80 who visited a university hospital in Daegu City. Data was collected by convenience sampling through structured self-administered questionnaire survey from December 2019 to January 2020, and a total of 212 copies were used for analysis. Results: Out of 212 total subjects, 112 were asthma patients (52.8%) and 100 were chronic obstructive pulmonary disease patients (47.2%). The average score (out of 10) of perception, knowledge and preventive behavior of patients with asthma for particulate matter was 7.92, 6.99, and 7.10, respectively, while those with chronic obstructive pulmonary disease scored 7.72, 6.24, and 6.80, respectively. The knowledge score was significantly higher in patients with asthma than those with chronic obstructive pulmonary disease (p=0.007). Factors affecting particulate matter preventive behavior were perception score, knowledge score, and age for asthma patients, and perception score for chronic obstructive pulmonary disease patients. Conclusions: As a result of the above, the factors relate to the preventive behavior of patients with asthma and chronic obstructive pulmonary disease were perception score, knowledge score, and age for asthma, and perception score for chronic obstructive pulmonary disease. Raising the level of particulate matter preventive behavior can prevent the deterioration of chronic pulmonary diseases caused by particulate matter, so the development of arbitration programs considering the characteristics of the patients according to the disease and continuous and repetitive education are required.

DSP Embeded Hardware for Non-contact Bio-radar Heart and Respiration Rate Monitoring System (DSP를 이용한 비 접촉식 도플러 바이오 레이더 생체신호 모니터링 시스템 임베디드 하드웨어의 개발)

  • Kim, Jin-Seung;Jang, Byung-Jun;Kim, Ki-Doo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.4
    • /
    • pp.97-104
    • /
    • 2010
  • In this paper, we provide an embedded type non-contact bio-radar heart and respiration rate monitoring system. We implemented the rate finding algorithm into the embedded system. The high-speed and reliable real-time signal processor is then tested. To avoid null-point data loss problem, we applied quadrature demodulation. Among several other combining techniques, we suggest arctangent demodulation for quadrature channel combining and DSP is used for real-time signal processing. We also suggest DC-offset compensation technique to preserve the wanted DC components of the IQ signals for accurate demodulation while keeping the dynamic range of the ADC lower. Using Texas Instrument C6711 series DSP and external 12Bit ADC, we implemented proper elliptic digital filter and autocorrelation detection algorithm for robust commercial hand held device.

Primary Undifferentiated Sarcoma of Left Atrium (좌심방에 발생한 원발성 미분화 육종-1례 보고-)

  • Lee, Seock-Yeol;Lee, Seung-Jin;Lee, Man-Bok;Youm, Wook;Lee, Kihl-Rho;Choi, Doo-Ho;Lee, Dong-Wha
    • Journal of Chest Surgery
    • /
    • v.31 no.8
    • /
    • pp.811-815
    • /
    • 1998
  • Primar99y cardiac tumors are rare and about 25% of primary cardiac tumors are malignant. A primary undifferentiated cardiac sarcoma, which very rare, is presented as follows: A 28-year old woman at the 32th week of pregnancy was admitted to the hospital because of dyspnea. A large intracardiac (left atrium) tumor was found with cardiac echocardiography and MRI. Emergency operation was performed under the diagnosis of left atrial myxoma. After Cesarean section, LA-tomy was done under the cardiopulmonary bypass. Tumor removal including endocardium of left atrium was done and final pathologic diagnosis was primary undifferentiated laft atrial sarcoma. After adjuvant radiotherapy, she has been followed up in out patient bases without problems up to now.

  • PDF

A Communicating Bronchopulmonary Foregut Malformation Associated with Absence of the Left Pericardium - A case report - (좌측 완전 심낭결손증을 동반한 Communicating Bronchopulmonary Foregut Malformation - 1예 보고 -)

  • Yoo, Dong-Gon;Park, Chong-Bin;Kang, Pil-Je;Lee, Jong-Hyeog;Kim, Chong-Wook
    • Journal of Chest Surgery
    • /
    • v.40 no.11
    • /
    • pp.793-797
    • /
    • 2007
  • A communicating bronchopulmonary foregut malformation (CBPFM) is a rare congenital anomaly that is characterized by a fistula between isolated respiratory tissue and the esophagus or stomach, The presence of accessory lung tissue arising from the primitive gastrointestinal tube is a common factor in the development of all forms of bronchopulmonary foregut malformations. Recurrent pneumonia associated with cystic radiographic structures is a characteristic of the condition. Further imaging studies using esophagogram, bronchography, computerized tomography, MRI, and arteriography can help in making a diagnostic evaluation. The treatment is a surgical resection of the involved lung tissue, and fistula closure with a good prognosis. We encountered a case of CBPFM, who presented with an extralobar pulmonary sequestration and bronchogenic cyst communicating with a tubular esophageal duplication that was associated with a complete left pericardial defect.

Research of video based Vibraimage technology stimulation examination KOCOSA (영상기반의 바이브라이미지 기술을 이용한 자극 검사에 대한 연구)

  • Lee, Jai-Suk;Lee, Il-ho;Lee, Tae-hyun;Choi, Jin-kwan;Chung, Suk-hwa;Han, Ji-soo
    • Convergence Security Journal
    • /
    • v.15 no.3_1
    • /
    • pp.41-51
    • /
    • 2015
  • Human have more complicate and skilled ability for lying even cheat ourself. It is not easy to cheat unconscious things like sweat, eyes, or voice, but if some one cheat own self, he can cheat every of that. Lie is one of the way to spread our gene and our instinct make a lie. Every living organism even bacteria or virus use similar trick to survive. In human body, there are more complicate and profound mechanism for lying like breathe, sweat, eyes, face or voice. We can control some of that and make a fake, but it can't be perfect. Human also called 'Homo Fallax' cause we have a language and skill to lie with it. In present, we can detect lie with polygraph, but it has few weakness. So we try to use Vibraimage technology for resolve it. In this paper, we describe how to use Vibraimage for lie detection and the research history.

Evaluating Cross-correlation of GOSAT CO2 Concentration with MODIS NDVI Patterns in North-East Asia (동북아시아에서 GOSAT CO2와 MODIS 식생지수 분포의 상관성 분석)

  • Choi, Jin Ho;Joo, Seung Min;Um, Jung Sup
    • Spatial Information Research
    • /
    • v.21 no.5
    • /
    • pp.15-22
    • /
    • 2013
  • The purpose of this work is to investigate correlation between $CO_2$ concentration and NDVI (Normalized Difference Vegetation Index) in North East Asia. Geographically weighted regression techniques were used to evaluate the spatial relationships between GOSAT (Greenhouse Observing SATellite) $CO_2$ measurement and MODIS (Moderate Resolution Imaging Spectroradiometer) vegetation index. The results reveals that $CO_2$ concentration to be negatively associated with NDVI. The analysis of Global Morans' I index and Anselin Local Morasn's I showed spatial autocorrelation between the overall spatial pattern of $CO_2$ and NDVI. Ultimately, there were clustered patterns in both data sets. The results show that carbon dioxide concentration shows non-random distribution patterns in relation to NDVI clusters, which proves that intense development activities such as deforestation are influencing carbon dioxide emission across the area of analysis. However, as the concentration of carbon dioxide varies depending on a variety of factors such as artificial sources, plant respiration, and the absorption and discharge of the ocean, follow-up studies are required to evaluate the correlations among more related variables.

A Clinical Case Report of a Cervical Herniated Intervertebral Disc Patient with Hyperventilation Syndrome Developed after Magnetic Resonance Imaging (자기공명영상 촬영 후 발생한 경추 추간판탈출증 환자의 과호흡증후군 호전 1례)

  • Jeong, Hoon;Kim, Dong-Sub;Kim, Mi-Riong;Kim, Eun-Soo;Kim, Tae-Hun;Park, Ji-Yong;Park, Hyun-Min;Cho, Nam-Hoon
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.7 no.1
    • /
    • pp.75-83
    • /
    • 2012
  • Objectives : The purpose of this study is to investigate the clinical application of acupuncture treatment to a cervical herniated intervertebral disc patient with hyperventilation syndrome developed after magnetic resonance imaging(MRI). Methods : A patient with cervical herniated intervertebral disc got hyperventilation syndrome after taking magnetic resonance imaging. To relieve symptoms, we took paperbag breathing first aid, but it had no effect. So we used acupuncture therapy with strong stimulation. To measure the outcome of the patient's improvement, we observed change of vital sign and verbal numerical rating scale(VNRS). Results : After 8 minutes of acupuncture treatment, the patient had significant improvement in change of vital sign and verbal numerical rating scale(VNRS). Conclusions : In emergency situation, acupuncture treatment as a first aid has a positive effect to control hyperventilation syndrome.

  • PDF

32-Channel Bioimpedance Measurement System for the Detection of Anomalies with Different Resistivity Values (저항률이 다른 내부 물체의 검출을 위한 32-채널 생체 임피던스 측정 시스템)

  • 조영구;우응제
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.6
    • /
    • pp.503-510
    • /
    • 2001
  • In this paper. we describe a 32-channel bioimpedance measurement system It consists of 32 independent constant current sources of 50 kHz sinusoid. The amplitude of each current source can be adjusted using a 12-bit MDAC. After we applied a pattern of injection currents through 32 current injection electrodes. we measured induced boundary voltages using a variable-gain narrow-band instrumentation amplifier. a Phase-sensitive demodulator. and a 12-bit ADC. The system is interfaced to a PC for the control and data acquisition. We used the system to detect anomalies with different resistivity values in a saline Phantom with 290mm diameter The accuracy of the developed system was estimated as 2.42% and we found that anomalies larger than 8mm in diameter can be detected. We Plan to improve the accuracy by using a digital oscillator improved current sources by feedback control, Phase-sensitive A/D conversion. etc. to detect anomalies smaller than 1mm in diameter.

  • PDF