• Title/Summary/Keyword: 자기진단신호

Search Result 163, Processing Time 0.026 seconds

Magnetic Resonance Characteristics of Ischemic Brain Infarction in Three Dogs (자기공명영상을 이용한 개의 허혈성 뇌경색의 진단 3례)

  • Lee, Ki-Ja;Kim, Young-Whan;Choi, Sung-Jin;Choi, Soo-Young;Jeong, In-Seong;Choi, Ho-Jung;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.31 no.5
    • /
    • pp.457-460
    • /
    • 2014
  • This case study describes the magnetic resonance characteristics of brain infarction in three dogs. Locations of the brain infarcts were cerebella, thalamus, and multifocal. The infarcts were sharply demarcated from adjacent brain parenchyma, homogeneous, T1-hypointense, T2-hyperintense with/without contrast enhancement, and minimal or no mass effect. Diffusion-weighted imaging (DWI) sequences were available in a dog and the infarcts were hyperintense on DWI and were hypointense on the apparent diffusion coefficient map.

네트웍 기반 자기베어링용 전력 증폭기 설계

  • 진재호;박종권;경진호;노승국
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.115-115
    • /
    • 2003
  • 최근 회전기계에 대한 세계적인 기술추세를 볼 때 해를 거듭할수록 더욱 정밀해지고 고속화에 대한 요구가 한층 증대되고 있으며 이러한 측면에서 여러 분야에 우수한 장점을 지니고 있는 능동적 자기베어링의 회전축계 활용에 대한 연구가 활발히 진행되고 있다. 특히 프랑스를 중심으로 한 미국, 일본 등이 이에 대한 연구를 활발하게 수행하여 고속 공작기계 스핀들을 비롯한 고진공 펌프 및 각종 터어빈, 압축기 등에 실용화시키는 단계에 있다. 그러나 국내 관련기술에 대한 연구는 연구소, 학계를 중심으로 실험실적인 기초연구로서 부분적으로 수행하는 단계에 있으며 관련분야 활용을 위한 본격적인 연구는 수행되지 못하고 있는 실정이고 이를 실용화시키기 위한 일환으로 능동적 자기 베어링의 회전 축계를 구성하고 있는 요소기술 중 하나인 전력 증폭기의 개발이 이뤄져야 할 필요성이 있는데 본 논문에서는 네트웍 기반 전력 증폭기 개발을 시도하였다. 전력 증폭기는 크게 리니어 앰프와 스위칭 앰프로 구분된다. 리니어 앰프의 경우 회로가 간단하고 노이즈가 비교적 작다는 장점이 있지만 전력손실 및 발열이 크기 때문에 에너지 측면에서 저 효율이라는 점과 따로 방열판을 부착해야 한다는 단점을 가지고 있고, 스위칭 앰프의 경우 전력손실이 작은 반면, 회로가 비교적 복잡하고 노이즈의 발생 가능성이 높다는 단점이 있다. 본 논문에선 위 두 가지 방식을 혼합한 혼합형 전력 증폭기로 설계하였다. 또한 기존에 전력증폭기의 경우 상위 주제어기로부터 제어량을 아날로그 신호로 통신하기 때문에 발생할 수 있는 EMI 노이즈신호에 대한 대책을 세워야 하는데 본 연구를 통해 개발된 전력증폭기는 따로 보조제어기(TMS320LF2406A)를 두어 상위 주제어기에 전력증폭기의 상태값을 궤환할 수 있도록 명령 신호체계를 전체 시스템의 샘플링 시간을 고려하여 비교적 전송 속도가 빠른 CAN(Controller Area Network)으로 구축하여 주제어기와 전력 증폭기간에 양방향 통신이 가능하도록 하였다. 이로써 전력증폭기의 상태정보를 알 수 있다. 따라서 본 논문에서는 칩 설계기술의 발전으로 가격대 성능비가 우수한 DSP(TMS320LF2406A)를 이용하여 과거의 아날로그 방식의 명령신호체계를 디지털 신호체계로 바꿈으로써 네트웍을 통해 전력증폭기의 상태진단 가능성을 검증한다.

  • PDF

Remote Measurement for Automobile′s ECU Diagnostic Signals based on the PDA (PDA 기반의 차량 진단신호의 원격 계측)

  • 윤여흥;서지원;이현호;권대규;이영춘
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.279-282
    • /
    • 2002
  • In this paper, we present a new method for monitoring of ECU's self diagnostic signals of vehicle without wire. In order to measure the ECU's self diagnostic signals, the interfaced circuit is designed to communicate ECU and a designed display terminal according to the ISO, SAE regulation of communication protocol standard. A 80C196KC processor is used for communicating ECU's self diagnostic signals and the results are sent to PDA monitoring system. Software on PDA is developed to monitor the ECU's self diagnostic signals using the Embedded Visual C++ compiler in which RS232 port is programmed by half duplex method. The algorithms for measuring the ECU's self diagnostic signals are verified to monitor ECU's state. At the same time, the information to fix the vehicle's problem can be shown on the developed PDA software. The possibility for remote measurement of ECU self diagnostic signal using PDA is also verified through the developed systems and algorithms.

  • PDF

Estimation of Causal Connectivity between Cortical Areas Using Near-Infrared Spectroscopy (NIRS) (근적외선 분광법을 이용한 대뇌피질영역 간 연관성 분석)

  • Lee, Seung-Deok;Go, Dal-Gwon;Jeong, Yeong-Jin;Kim, Do-Won;Im, Chang-Hwan;Kim, Beop-Min
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2009.10a
    • /
    • pp.151-152
    • /
    • 2009
  • 최근 신경과학 분야에서 대뇌피질 영역 간 연관성 분석은 신경학적 질병 (자폐증, 간질, 정신 분열증)의 분석 및 진단에 적용되고 있다. 기존 대뇌피질 영역 간 연관성 분석은 뇌전도 (EEG), 기능적 자기공명영상 (fMRI), 뇌자도 (MEG)등이 이용되었지만, 뇌전도의 낮은 공간분해능, 기능적 자기공명영상의 낮은 시분해능 등은 영역 간 연관성 분석에 단점으로 작용되고 있다. 반면, 근적외선 분광법(NIRS)은 대뇌피질에서의 혈류변화(oxy-, deoxy-hemoglobin)를 비침습적이며 빠른 시분해능으로 측정할 수 있는 방법으로 최근 신경과학 분야에 응용되고 있다 [1-2]. 본 논문에서는 근적외선 분광법을 이용한 대뇌피질영역 간 연관성 분석의 효용성을 입증하기 위해, 쥐의 수염자극 시 대응되는 지역 (일차-, 이차 체감각피질, 일차 운동피질 영역)에서의 혈류변화 신호의 영역 간 연관성 분석을 하였다. 본 연구결과에 의하면 수염자극 시 일차-, 이차 체감각피질 영역에서의 방향성은 확인할 수 없었고, 일차-, 이차 체감각피질 영역에서 일차 운동피질영역으로의 방향성은 확인할 수 있었다. 본 결과는 기존 수염자극 시 활성화되는 전기신호의 패턴과 일치하며, 향후 신경과학적 질병의 분석 및 진단에 근적외선을 이용한 대뇌피질 영역 간 연관성 분석이 유용할 수 있음을 보여준다.

  • PDF

Susceptibility-Weighted Imaging as a Distinctive Imaging Technique for Providing Complementary Information for Precise Diagnosis of Neurologic Disorder (신경계 질환에 관한 정확한 진단을 위해 다양한 보완 정보를 제공하는 독특한 영상 기법으로서의 자기화율 강조 영상)

  • Byeong-Uk Jeon;In Kyu Yu;Tae Kun Kim;Ha Youn Kim;Seungbae Hwang
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.1
    • /
    • pp.99-115
    • /
    • 2021
  • Various sequences have been developed for MRI to aid in the radiologic diagnosis. Among the various MR sequences, susceptibility-weighted imaging (SWI) is a high-spatial-resolution, three-dimensional gradient-echo MR sequence, which is very sensitive in detecting deoxyhemoglobin, ferritin, hemosiderin, and bone minerals through local magnetic field distortion. In this regard, SWI has been used for the diagnosis and treatment of various neurologic disorders, and the improved image quality has enabled to acquire more useful information for radiologists. Here, we explain the principle of various signals on SWI arising in neurological disorders and provide a retrospective review of many cases of clinically or pathologically proven disease or components with distinctive imaging features of various neurological diseases. Additionally, we outline a short and condensed overview of principles of SWI in relation to neurological disorders and describe various cases with characteristic imaging features on SWI. There are many different types diseases involving the brain parenchyma, and they have distinct SWI features. SWI is an effective imaging tool that provides complementary information for the diagnosis of various diseases.

Investigation of Correlations of Double Inversion Recovery and MR Spectroscopy on Breast MR Imaging (유방 자기공명영상에의 이중반전회복기법과 자기공명분광영상법의 상관관계 연구)

  • Ryu, Jung Kyu;Rhee, Sun Jung;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.34-42
    • /
    • 2014
  • Purpose : To evaluate the correlation of lesion-to-normal ratio (LNR) of signal intensity from double inversion recovery MR imaging and total choline-containing compound (tCho) resonance from single voxel MR spectroscopy in breast cancers. Materials and Methods: Between August 2008 and December 2009, 28 patients who were diagnosed as breast cancer and had undergone both double inversion recovery (DIR) MR imaging and MR spectroscopy (MRS) were included in this study. The signal intensities of the lesion (L) and ipsilateral normal breast tissue (N) were measured in region of interest of each breast cancer in DIR and contrast enhance MR image (CE-T1WI) to calculate the LNR value for each technique. MRS was performed using single-voxel MR spectroscopy. The height, width and area of tCho resonance were compared with each LNR of DIR and CE-T1WI. We used Pearson's correlation coefficient(r) for correlation analysis and the significance level was p=0.05. Results: There was no statistically significant correlation between LNR of CE-T1WI and height (r=-0.322, p=0.094), width (r=-0.233, p=0.232) and area (r=-0.309, p=0.109) of MRS tCho. There was no statistically significant correlation between LNR of DIR and height (r=0.067, p=0.735), width (r=-0.287, p=0.139) and area (r=0.012, p=0.953) of MRS tCho, either. The Pearson's correlation coefficient was 0.186 between LNRs of CET1WI and DIR (p=0.344). Conclusion: There was no statistically significant correlation between LNR of DIR and relative amount of tCho resonance of MRS.

MR Imaging of Intracranial Pediatric Meningiomas: Manifestations in 16 Patients (두개강내 소아 수막종 16예의 자기공명영상 소견)

  • Eo, Hong;Kim, Ji-Hye
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.188-196
    • /
    • 2008
  • Purpose : To describe the clinical, MR imaging, and pathologic findings of pediatric meningiomas. Materials and Methods : The authors retrospectively reviewed the medical records and MR images of 16 pediatric patients with pathologically proven meningioma. Mean patient age at diagnosis was 14 years (range, 3-18). MR images were reviewed for details of lesion sizes, locations, signal intensity (SI), marginal characteristics, internal architectures, enhancements, and dural and parenchymal changes. The findings of other imaging modalities and of pathological examinations were also analyzed. Results : Mean tumor size was 5.24 cm (range, 1.3-18.1 cm) and locations were supratentorial in 12 and infratentorial in 4. SI of masses were variable, that is, high in 9, iso in 4, and low in 3 on T2 weighted images (T2WI), and low (n=11), iso (n=4), or high (n=1) on T1WI images. All lesions were visualized as well-demarcated enhancing masses. Five of the tumors were heterogeneous with cystic or necrotic components. Dural attachment was observed in 11 patients and adjacent brain edema in 10. Tumors exhibited hyperdense (n=6) or isodense (n=4) on non-enhanced CT scans, and 3 of the 7 angiograms demonstrated blood supply from the internal carotid artery. Pathologic examinations revealed the following subtypes; transitional cell (n=4), meningotheliomatous (n=4), chordoid (n=2), fibrous (n=2), clear cell (n=1), hyalinized (n=1), rhabdoid papillary (n=1), and atypical (n=1). Conclusion : Pediatric meningiomas occur usually in teenagers, have diverse pathological types, and may produce atypical imaging findings, such as, a heterogeneous internal content or findings suggestive of intraaxial tumors.

  • PDF

A Study on the Artifact Reduction Method of Magnetic Resonance Imaging in Dental Implants and Prostheses (치아 임플란트와 보철에서 발생하는 자기공명영상의 인공물 감소방안 연구)

  • Shin, Woon-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.1025-1033
    • /
    • 2019
  • Although magnetic resonance imaging without linear hardening of CT is recognized as a method of obtaining high contrast of tissue and excellent resolution image in brain disease and head and neck examination, magnetic susceptibility artifact is generated in case of metal implants in the oral cavity, which is an obstacle to image diagnosis. Therefore, an effort was made in this thesis to find a method to reduce artifacts caused by dental implants and prosthesis in MRI. Implant-induced artifacts in magnetic resonance imaging showed that the signal size increased with shorter TE in GE technique and was inconsistent with water temperature change. In SE technique as well, the signal size of water was generally higher than that of air, but the signal to noise ratio (SNR) was not different by air and temperature. In EPI technique, images with fewer artifacts were obtained quantitatively and qualitatively when there was more water than air, and the signal to noise ratio was measured the highest, especially at water temperatures of 20° and 30°. In conclusion, when examining using the EPI technique rather than the SE or the GE technique, obtaining brain diffusion using a 20° and 30° water bag reduces the magnetic susceptibility artifacts caused by implants and prosthesis, suggesting that it may provide images with high diagnostic value.

Development of Magnetoimpedance Sensor Utilizing Soft Magnetic Amorphous Ribbon with Exchange Coupling and Application to Nondestructive Testing (교환결합을 가진 연자성 비정질 리본을 이용한 자기 임피던스 센서 개발과 비파괴검사 응용)

  • Yoon, Seok-Soo;Kim, Gun-Woo;Lee, Sang-Hun;Kim, Cheol-Gi
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.5
    • /
    • pp.401-406
    • /
    • 2008
  • Recently, portable magnetic sensors with high sensitivity are strongly required for various applications such as biosensor, nondestructive testing and directional sensor. A novel magnetic sensor system was developed by utilizing giant magnetoimpedance(MI) effect of soft magnetic ribbons. The sensor system consists of sensing head of $Co_{66}Fe_{4}Si_{15}B_{15}$ ribbon having asymmetric MI characteristics through exchange coupling produced by field-annealing in open air and circuit for signal processing. The sensor system showed almost linear characteristics in dynamic range of $-1\;Oe\;{\sim}\;1\;Oe$ and sensitivity of 10.5 V/Oe. The sensor was applicable to nondestructive testing system to detect defects in wire ropes.

MRI Findings of Intramuscular Foreign Body Injection: A Case Report (근육 내 이물질 주사의 자기 공명 영상 소견: 증례 보고)

  • So, Seong Yong;Kim, Hyun-Joo;Choi, Deuk Lin;Hong, Seong Sook;Chang, Yun-Woo;Park, Sung Tae
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.1
    • /
    • pp.59-62
    • /
    • 2013
  • There are various types of foreign body reactions, such as inflammation, edema, fluid collection, hematoma, infection, abscess and granulomas. There are various imaging findings according to types of foreign bodies and depending on the lapse of time. Therefore, correct diagnosis of a foreign body reaction is difficult and easily confused with soft tissue neoplasm. The MRI is ideal for the detection of foreign bodies regardless of radiolucency or acoustic impedance. It is especially very useful in the evaluation of the surrounding tissue reaction. The authors report a case of a 26-year-old female patient with both forearm swelling due to self-injection of a mixture of powdered tablets and saline. The lesion shows numerous internal T1 and T2 dark signal intensity micro-spots with surrounding fluid collection, which are diagnosed as foreign bodies with surrounding inflammatory changes during an operation.