• Title/Summary/Keyword: 자기지전류

Search Result 179, Processing Time 0.022 seconds

Construction of a Low Magnetic Field Standard System Using a Precision Solenoid (정밀솔레노이드를 사용한 저자장 표준시스템 제작)

  • 박포규;손대락;우병칠;김창석
    • Journal of the Korean Magnetics Society
    • /
    • v.2 no.2
    • /
    • pp.150-155
    • /
    • 1992
  • The low magnetic field standard below 1 mT with resolution of 100 nT has been established for the calibration and testing of low field magnetometers. A precision single layered solenoid, which is made of quartz tube and bare copper wire, was constructed in order to generate a precise magnetic field. To improve the field homogeneity in the solenoid, three-current method was employed. The injected current and injection points on the solenoid were optimized by computer simulation. The magnetic field uncertainty in the solenoid was 0.1 % and 0.01 % in the range of ${\pm}5\;cm$ from the center for a single and three-current methods respectively. We also constructed a testing system for the dynamic properties of low field magnetometers.

  • PDF

Design of Electronic Ballast for HID Lamps (HID 램프용 전자식 안정기의 설계)

  • 이치환
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.14-20
    • /
    • 1999
  • This paper presents a design techniques for an electronic ballast of HID lamps. An electronic ballast for HID lamps usually employs a high-frequeocy resonant inverter and voltage-to-frequency converter to control the outpIt and a half-bridge and series resonant circuit are chosen for the ballast First, to design PI controller, the inverter with V/F converter is modeled with a transfer function and the controller PI gains are determined. This paper shows that an integral controller is only needed to control the current. Second, a se1f-feedback controller is proposed. This structure, simple and robust, is analyzed and a feedback gain is determined by using the inverter model. Experirrental system is built with a commercial 250W high pressure sodium lamp and the results show a validity of the proposed ballast and the total efficiency is increased by 5%.

  • PDF

A Study on the Power supply of a magnetic levitation system(MAGLEV) (자기부상열차용 전원장치에 관한 연구)

  • Chung, Choon-Byeong;Jeon, Kee-Young;Jeon, Ji-Young;Oh, Bong-Hwan;Lee, Hoon-Goo;Kim, Yong-Joo;Han, Kyung-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.258-266
    • /
    • 2007
  • When the magnetic levitation system(MAGLEV) initially rise, The MAGLEV has a weak point that is very large variation of the electric current. In this paper, The author applied the multi-loop-control to stably control the magnetic levitation system(MAGLEV). The gains of the control algorithm were selected based on pole locations formulated from a prototype Bessel transfer function model. The design incorporate tradeoffs in DC-to-DC converter hard-ware para-meters and pole locations. In order to confirm the superiority of the proposed pole selection md controller, MATLAB simulation and experiment results are presented.

Magnetic analysis of a finite solenoid (유한 솔레노이드의 자속밀도 해석)

  • Lee, Ju-Hee;Hwang, Seon;Lee, Dong-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.6453-6457
    • /
    • 2015
  • In this paper, the theoretical analysis for a solenoid with a finite length was verified by the finite element simulation. The solenoids are widely being used in the field of mechanical, industrial, medical industry due to their simple structure and fast responses. Solenoid actuators use an electromagnetic force. A magnetic field is formed around the solenoid coil when a current is applied. The magnetic force generated by the magnetic field enables an inside plunger to move linearly. The axial and radial magnetic fields (magnetic flux density, B) at a certain point were calculated from the Biot-Savart's law and compared with the simulation analysis from the ANSYS-Magnetostatic S/W. Comparison result, an error exists in the error range, and could therefore verify the accuracy.

Electro-Magnetic Field Analysis for Optimal design of Magneto-Rheological Fluid Damper Core (자기점서유체 댐퍼 코어의 최적화 설계를 위한 전자기장 해석)

  • Song, June-Han;Son, Sung-Wan;Chun, Chong-Keun;Kwon, Young-Chul;Ma, Yang-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1511-1517
    • /
    • 2008
  • The magneto-rheological fluid expresses different cohesiveness according to the strength of the external electric current. The magneto-rheological fluid damper, which uses such characteristics of the fluid, generates shear force due to the fluid's cohesiveness. The core can be said to determine the magneto-rheological fluid damper's performance. This study uses the finite element analysis to compare the performance of different electromagnetic forces, which are affected by the shapes of the coil, and thus to find the optimum design for the core. In addition, as a step to construct a high-efficient damper, we suggest a type of damper that can control multiple coils and compares the performance of this damper and that of the standard damper by comparing the performance of their electro-magnetic fields.

Study on The Electromagnetism of Interior Permanent Magnet Synchronous Motor due to Field Weakening (매입형 영구자석 동기전동기의 약계자 제어에 따른 전자기적 특성 연구)

  • Kwon, Soon-O
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.1
    • /
    • pp.254-260
    • /
    • 2013
  • This paper deals with electromagnetic characteristics of IPMSM (Interior Permanent Magnet Synchronous motor) caused by field weakening current control. In order to extend operation speed, field weakening current control is generally used in IPMSM operation. During field weakening, distorted linkage fluxes are resulted by saturation of core material. Therefore, distorted input voltage waveform is required for sinusoidal current input. As the current vector angle increases for field weakening, distortion of linkage flux and back-emf becomes significant. This situation is analyzed by 2-dimensional finite element analysis and verified by experiment. With the results, it is concluded that motor parameters, such as linkage flux by permanent magnet, phase resistance, d-q axis inductance, are insufficient for estimating required voltage for given speed especially in field weakening and additional considerations for increased harmonics of voltage are required.

Analysis of Electromagnetic Coupling to an Infinitly Long Wire through a Slot in an Infinite Conducting Plate (무한도선과 무한 도체평판에 있는 슬롯간의 전자기적 결합에 대한 해석)

  • Baek, W. S.;Lee, C. H.;Cho, U. H.;Cho, Y. K.;Son, H.
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.2
    • /
    • pp.137-150
    • /
    • 1997
  • The problem of electromagnetic coupling into a thin conducting wire through a slot in an infinite conducting is analyzed by use of MPIE(mixed potential integral equation) and two- dimensional moment method using subsectional(rooftop) basis functions. The equivalent circuit is derived using a center-repesentation method which is valid in a narrow slot case. The equi- valent magnetic currents on the slot and the induced currents on the wire are caculated respec- tively, for the TM wave is incident upon the slot with arbitrary angle of incidence. The theoretical transmission coefficients of transmission line which is composed of thin-wire and infinite conducting plate with a narrow slot are compared and found to be in good agreement with experimental results.

  • PDF

Hysteresis Current Control with Self-Locked Frequency Limiter for VSI Control (자기동조 주파수 제한기를 갖는 전압원 인버터의 히스테리시스 전류제어)

  • Choe, Yeon-Ho;Im, Seong-Un;Gwon, U-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.1
    • /
    • pp.23-33
    • /
    • 2002
  • A hysteresis control is widely used to control output current of inverter. A hysteresis bandwidth is affected by system parameters such as source voltage, device on/off time, load inductance and resistance. The frequency limiter is used to protect switching devices overload. In the conventional hysteresis controller, a lock-out circuit with D-latch and timer is used to device protection circuit. But switching delay time and harmonic components are appeared in output current. In this paper the performance of lock-out circuit is tested, and new circuit for switching device fault protection is proposed ad it's performance is simulated.

Analysis of Leakage Current Waveforms for Transmission Line Porcelain Insulators due to ESDD Contamination (ESDD 오손에 따른 송전용자기애자의 누설전류 파형의 분석)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1461-1470
    • /
    • 2012
  • This paper reports the contamination performance of transmission line porcelain insulators tested under five different contaminant conditions - clean and ESDD (equivalent salt deposit density) level (A, B, C, and D) through measurement of their leakage current under drop of potential method. To estimate the contamination for transmission line porcelain insulators, leakage current waveform and its maximum value were measured under step-up power test. In the clean insulators test, % distortion factors decreased with increasing step-up power, and as the ESDD level increased, some characteristics such as frequency analysis, harmonics and % distortion facotor could be used for contamination diagnosis of the transmission line porcelain insulators.

The Analysis of Torque Ripple of SRM Using Artificial Neural Network (신경회로망을 이용한 SRM의 맥동토오크 해석)

  • 오석규;최태완
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.3
    • /
    • pp.256-262
    • /
    • 1998
  • The torque of SRM depends on phase current and the derivative of inductance. But the inductance of SRM is nonlinearly changed according to rotor position angle and phase current because of saturation in magnetic circuit, and it is difficult to control the desired torque. This paper proposes inductance modeling method using ANN(Artificial Neural Network) that is used to simulate the inductance which is nonlinearly varied with rotor position and current. The torque ripple is analyzed and input voltage and current condition to reduce torque ripple is simulated by inductance model.

  • PDF