• Title/Summary/Keyword: 자가 보정 법

Search Result 107, Processing Time 0.028 seconds

Orthogonality Calibration of a High Precision Stage using Self-calibration Method (자가보정법을 이용한 정밀 스테이지의 직각도 보정)

  • Kim, Ki-Hyun;Park, Sang-Hyun;Kim, Dong-Min;Jang, Sang-Don
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.3
    • /
    • pp.50-57
    • /
    • 2010
  • A high precision air bearing stage has been developed and calibrated. This linear-motor driven stage was designed to transport a glass or wafer with the X and Y following errors in nanometer regime. To achieve this level of precision, bar type mirrors were adopted for real time ${\Delta}X$ and ${\Delta}Y$ laser measurement and feedback control. With the laser wavelength variation and instability being kept minimized through strict environment control, the orthogonality of this type of control system becomes purely dependent upon the surface flatness, distortion, and assembly of the bar mirrors. Compensations for the bar mirror distortions and assembly have been performed using the self-calibration method. As a result, the orthogonality error of the stage was successfully decreased from $0.04^{\circ}$ to 2.48 arcsec.

The First Hyperpolarizability $\beta$ measurement of dipoles and cotupoles by the Hyper-Rayleigh scattering technique (Hyper-Rayleigh scattering(HRS)방법을 이용한 쌍극자와 팔중극자의 1차 초분극율$\beta$측정)

  • ;;;;;Mingjun Piao
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2002.07a
    • /
    • pp.104-105
    • /
    • 2002
  • Hyper-Rayleigh scattering(HRS)방법을 이용하여 쌍극자와 새로이 합성된 팔중극자들의 1차 초분극율 $\beta$를 측정하였다. External reference 법을 이용하였고, reference 물질로는 잘 알려져 있는 쌍극자인 PNA를 이용하여 Disperse Red 1과 팔중극자들의 1차 초분극율 $\beta$의 값을 구하였다. 또한 HRS 의 세기뿐만 아니라 이들 물질의 two-photon induced fluorescence 스펙트럼을 측정하였다. 1차 초분극율 $\beta$값은, 먼저 시료로부터 scattering 된 신호를 파장변화에 따른 스펙트럼으로 측정하여 two-photon induced fluorescence를 뺀 순수한 HRS 신호만을 이용하고, 실험에 사용된 물질들은 532nm에서 흡수가 있어 second harmonic generation 신호가 시료에 의해 흡수가 되므로 흡수효과를 식 $I_{2{\omega}}$(obs)= $I_{2{\omega}}$(true) $e^{-{\sigma}lN}$ ---(1)를 이용하여 흡수에 의한 신호의 감소 효과를 보정하여 값을 구했다. (중략)

  • PDF

추적자 방법에 의한 유량측정법

  • 이선기;정백순;한정란;이철언
    • Nuclear Engineering and Technology
    • /
    • v.29 no.6
    • /
    • pp.1-7
    • /
    • 1997
  • 원자력 발전소의 주급수 유량은 원자로 열출력 산출에 사용되는 중요한 변수로서, 노심관리 뿐만 아니라 원자로 안전운전에도 중요하며, 발전소 출력에 직접적인 영향을 미친다. 그러므로 현재 사용되고 있는 주급수 유량 측정설비의 정확도 검증 및 보정을 위하여 정확한 유량측정법의 개발이 필요한 실정이다. 본 연구는 화학 추적자 방법에 의한 고정밀 유량측정 기술을 개발하여, 원자력 발전소 주급수 계통의 유량측정에 사용되고 있는 벤츄리(Venturi), 노즐(Nozzle), 오리피스(Orifice) 등의 유량계에 관한 검증용으로 활용함으로서 발전소의 안전성을 유지하는 범위에서 출력을 극대화시킨다는 목적으로 예비 실험장치를 설계 설치하여, 본 방법의 유효성에 대해서 검토하였다. 그 결과, 본 연구에 사용한 추적자 방법은 유량변동에도 좋은 응답성을 보이고 있으며, 유량측정에 있어서도 매우 신뢰성 있는 측정이 가능하다.

  • PDF

Exploring nano structures with a pair of eyes

  • Jeon, Cheol-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.85.1-85.1
    • /
    • 2016
  • 현대 과학기술에는 표면/계면 및 나노물질의 구조와 물성을 분석하는 다양한 방법들이 존재한다. 이들 분석장비들의 분해능과 감도의 향상으로 이전에는 보지 못한 물성들이 속속 발견되고 있다. 이러한 흐름 속에서 분석장비들의 다기능 시대가 열리고 있다. 예전에는 성분, 형태, 구조, 전자구조 등을 분석하기 위해 각각에 해당하는 분석장비들이 동원되었다. 하지만 21세기에 접어들어 분석장비들이 두 종류 이상의 분석이 가능하도록 개발되었다. 예를 들면, TEM으로 형태를 보는 것 외에도 TED와 EELS로 구조와 성분을 동시에 확인할 수 있게 되었다. 전통적인 성분 및 전자구조 분석법의 하나인 광전자분광법도 microscopy 기능을 탑재하는 변신이 있었다. 본 발표에서는 빛과 전자를 시료에 조사하여 물질의 성분, 형태, 구조, 전자구조 등을 동시에 분석이 가능한 분석법들에 대해 소개하고자 한다. 그 중, SPEM(Scanning Photoelectron Emission Microscopy)은 포항가속기연구소에 설치되어 있으며, PEEM(Photoelectron Microscopy)과 LEEM(Low Energy Electron Microscopy)은 수차보정장치를 갖춘 사양으로 최근 한국기초과학지원연구원에 설치되었다. 위에 언급한 장비를 활용하여 얻은 데이터를 바탕으로 나노물질의 표면 및 계면의 특성을 분석하는 방법 및 최근 연구 결과를 소개하고자 한다.

  • PDF

Parameter Calibration of Storage Function Model and Flood Forecasting (1) Calibration Methods and Evaluation of Simulated Flood Hydrograph (저류함수모형의 매개변수 보정과 홍수예측 (1) 보정 방법론과 모의 홍수수문곡선의 평가)

  • Song, Jae Hyun;Kim, Hung Soo;Hong, Il Pyo;Kim, Sang Ug
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.1B
    • /
    • pp.27-38
    • /
    • 2006
  • The storage function model (SFM) has been used for the flood forecasting in Korea. The SFM has a simple calculation process and it is known that the model is more reasonable than linear model because it considers non-linearity of flood runoff. However, the determination of parameters is very difficult. In general, the trial and error method which is an manual calibration by the decision of a model manager. This study calibrated the parameters by the trial and error method and optimization technique. The calibrated parameters were compared with the representative parameters which are used in the Flood Control Centers in Korea. Also, the evaluation indexes on objective functions and calibration methods for the comparative analysis of simulation efficiency. As a result, the Genetic Algorithm showed the smallest variation in objective functions and, in this study, it is known that the objective function of SSR (Sum of Squared of Residual) is the best one for the flood forecasting.

Ultra-Wide Band Sensor Tuning for Localization and its Application to Context-Aware Services (위치추적을 위한 UWB 센서 튜닝 및 상황인지형 서비스에의 응용)

  • Jung, Da-Un;Choo, Young-Yeol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.6
    • /
    • pp.1120-1127
    • /
    • 2008
  • This paper presents implementation of localization system using UWB (Ultra-Wide Band) sensors and its experimental results along with development of context-aware services. In order for precise measurement of position, we experimented various conditions of pitch angles, yaw angles, number of sensors, height of tags along with measuring errors at each installation. As an application examples of the location tracking system, we developed an intelligent health training management system based on context-aware technology. The system provides appropriate training schedule to a trainee by recognizing position of the trainee and current status of gymnastic equipments and note the usage of the equipment through a personal digital assistant (PDA). Error compensation on position data and moving direction of the trainee was necessary for context-aware service. Hence, we proposed an error compensation algorithm using velocity of the trainee. Experimental results showed that proposed algorithm had made error data reduce by 30% comparing with the data without applying the algorithm.

Anthropometric Measurements and Volumetric Measurement of the Human Female Breast (유방용적 측정과 인체계측에 관한 연구 -중년여성을 대상으로-)

  • Lee, Kyung-Mi;Park, Hei-Sun
    • Journal of the Korean Home Economics Association
    • /
    • v.38 no.12
    • /
    • pp.249-256
    • /
    • 2000
  • 본 연구는 유방절제수술을 받은 여성들이 착용하는 브래지어와 보정물의 중량을 결정하는데 필요한 예비자료를 수집하기 위하여 중년여성 12명을 대상으로 31항목에 대한 인체계측 및 석고법에 의한 유방용적측정을 실시하고 얻어진 유방관련 항목자료와 각 치수별 무게자료를 비교.분석하였다. 그 결과는 다음과 같다. 1.유방용적 측정결과 모든 피험자에 있어 오른쪽과 왼쪽 유방용적에 차이가 있는 것으로 나타났다. 2. 브래지어 컵 치수는 가슴둘레와 밑가슴둘레간의 차이로 결정되는 것이므로 유방용적과 브래지어 치수의 크기가 일치하지 않는 것으로 나타났다. 3.절반 이상의 피험자가 자신의 브래지어 치수를 잘못 선택하고 있는 것으로 나타났다.

  • PDF

A Data Optimization using a Framework based on Bigdata-R for Analysis of Coatings Mixing Process (코팅제 배합 공정 분석을 위한 빅 데이터-R 기반의 프레임워크를 이용한 데이터 최적화)

  • Jeong, Yeonghoon;Lee, Jongran;Noh, SeongYeo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.04a
    • /
    • pp.958-961
    • /
    • 2015
  • 코팅제는 다양한 산업 분야에서 중요성이 더욱 커지고 있으나 실제 제조업체에서는 여전히 작업자의 경영에 의존하여 배합공정을 수행하는 실정이다. 본 논문에서는 R과 실험계획법을 이용하여 코팅제 배합 공정을 분석하기 위한 프레임워크를 제안한다. 제안된 프레임워크를 통한 분석 결과는 보다 정량적인 작업 기준 데이터를 확보하고 작업 현장에 제공함으로써 코팅제 배합 공정을 개선시킬 수 있다. 특히 정확한 배합 기준이 되는 표준 데이터의 부재로 인한 품질 저하와 원가 손실을 감소시키고, 배합 공정에서 발생한 오차 데이터에 대하여 R과 실험 계획법을 이용한 분석을 통하여 표준 보정 관계식을 도출함으로써 차후 발생 가능한 오차에 대한 대응 방안을 제시할 수 있다.

Accuracy Improvement and Systematic Bias Analysis of Scanning White Light Interferometry for Free-form Surfaces Measurements (자유 곡면 형상 측정을 위한 백색광 주사 간섭계의 정확도 향상 및 시스템 오차 분석)

  • Ghim, Young-Sik;Davies, Angela;Rhee, Hyug-Gyo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.7
    • /
    • pp.605-613
    • /
    • 2014
  • Scanning white-light interferometry is an important measurement option for many surfaces. However, serious profile measurement errors can be present when measuring free-form surfaces being highly curved or tilted. When the object surface slope is not zero, the object and reference rays are no longer common path and optical aberrations impact the measurement. Aberrations mainly occur at the beam splitter in the interference objective and from misalignment in the optical system. Both effects distort the white-light interference signal when the surface slope is not zero. In this paper, we describe a modified version of white-light interferometry for eliminating these measurement errors and improving the accuracy of white-light interferometry. Moreover, we report systematic errors that are caused by optical aberrations when the object is not flat, and compare our proposed method with the conventional processing algorithm using the random ball test.

An Efficient Background Modeling and Correction Method for EDXRF Spectra (EDXRF 스펙트럼을 위한 효율적인 배경 모델링과 보정 방법)

  • Park, Dong Sun;Jagadeesan, Sukanya;Jin, Moonyong;Yoon, Sook
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.8
    • /
    • pp.238-244
    • /
    • 2013
  • In energy dispersive X-ray fluorescence analysis, the removal of the continuum on which the X-ray spectrum is superimposed is one of the most important processes, since it has a strong influence on the analysis result. The existing methods which have been used for it usually require tight constraints or prior information on the continuum. In this paper, an efficient background correction method is proposed for Energy Dispersive X-ray fluorescence (EDXRF) spectra. The proposed method has two steps of background modeling and background correction. It is based on the basic concept which differentiates background areas from the peak areas in a spectrum and the SNIP algorithm, one of the popular methods for background removal, is used to enhance the performance. After detecting some points which belong to the background from a spectrum, its background is modeled by a curve fitting method based on them. And then the obtained background model is subtracted from the raw spectrum. The method has been shown to give better results than some of traditional methods, while working under relatively weak constraints or prior information.