• Title/Summary/Keyword: 잉여전력

Search Result 106, Processing Time 0.041 seconds

Photovoltaic Generation System Design for Controlling the Temperature and Humidity of Hospital (병원내 온도와 습도조절을 위한 태양광 발전 시스템 설계)

  • Cho, Moon-Taek;Lee, Chung-Sik;Baek, Jong-Mu
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.127-134
    • /
    • 2011
  • In this paper we propose an improved PV generation systems. Improved systems for temperature and humidity controlled heating and air conditioning offers a pleasant environment within the building, set up chopper and consists of a PWM voltage type inverter. The proposed system is stable modulation for a one-chip microprocessor using the synchronous signal and control signals was treated. The proposed system is a PWM voltage type inverter and phase of the synchronous to the grid voltage to detect the system voltage and inverter output to drive the statue, so surplus power to connection was able to, certain buildings such as buildings or hospitals, temperature and humidity sensor is applied to the good dynamic characteristic could be obtained. In addition, the system was applied to the high power factor and low-frequency harmonics by maintaining the output load and grid to power to be supplied to a stable control could get a good result.

Torque Predictive Control of Induction Motor Drives with Improved Performance and Reduced Torque Ripple (유도 전동기의 동특성 개선과 토크 리플 저감을 위한 토크 예측 제어)

  • In, Hyochul;Cho, Yongsoo;Lee, Kyo-Beum
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.251-252
    • /
    • 2016
  • 본 논문에서는 토크 리플 저감과 동특성을 개선하는 유도 전동기(IM)의 토크 예측 제어 기법을 제안한다. 제안하는 방법은 고정된 전압 벡터의 크기를 사용하지 않고, 토크 변동분 넓이의 합이 최솟값이 되도록 하는 전압 벡터 인가 시간을 결정하여 유도 전동기에 인가한다. 이 방법은 토크 제어에 필요한 전압만 인가하므로 잉여 전압이 발생하지 않는다. 따라서 정확한 제어 성능을 가지면서도 과도 상태에서는 동특성이 개선되고, 정상 상태에서는 토크 리플의 크기를 최소화할 수 있다. 제안하는 알고리즘의 유효성과 우수성을 시뮬레이션으로 검증한다.

  • PDF

Design of New-Renewable System for Energy Independence of Water Treatment Plant (수도사업장 에너지 자립화를 위한 신.재생에너지 구축 설계)

  • Choi, Young-Kwan;Kim, Yong-Kuk;Kim, Hee-Gon;Kim, Jong-Gyeum
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2099-2100
    • /
    • 2011
  • 본 논문은 ${\circ}{\circ}$댐에서 원수를 공급받는 ${\circ}{\circ}$정수장(이하 정수장) 유입관로의 잉여압력을 이용하여 소수력 발전기를 설치하고, 정수장 여유부지에 태양광발전설비를 계획하여 총163.4kW(Peak 사용전력 128.16kW)의 시설용량으로 연간전력사용량(451 MWh) 대비 110% 정도의 발전생산(약500MWh)이 가능한 에너지자립형 개념의 정수장을 설계한 사례이다.

  • PDF

Basic Economic Evaluation of Industrial Complex CHP Plant for Recieving Heat and Dispatch (수열 및 급전에 따른 산업단지 열병합 발전소 운전에 대한 기초 경제성 평가)

  • Seo, Young-Ho;Lee, Joon-Hee;Cho, Chung-Sik;Jeon, Yong-Han;Han, Sang-Chul;Cho, Sung-Kap
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05b
    • /
    • pp.981-984
    • /
    • 2011
  • 본 논문에서는 산업단지에 공정증기를 공급하는 열병합 발전소 건설에 대한 타당성 분석시 적용되는 기초 경제성 분석에 대한 것으로, 인근의 타 열병합 발전소에서 잉여열을 수열받고 중압급전을 하였을 경우 매전수익 및 기타 소요 금액 산출을 통해 연간 발생되는 발전소 경제성 평가에 목적이 있다. 시스템 구성은 순환유동층보일러, 증기터빈, 복수기, 급수펌프, 탈기기 및 급수가열기 그리고 수처리 설비로 구성되어 있다. 중앙급전 지시를 받을 경우 열원설비인 보일러는 최대부하로 운전되기 때문에 이때 전력생산량이 증가하였으며, 수열을 받을 경우도 수열된 증기는 탈기기 및 급수가열기 등의 열원 및 증기터빈으로 공급되기 때문에 전력생산량이 증가하였다.

  • PDF

System Performance Depending on the Deviation of RDPS in Dispersion Managed Optical Transmission Link with Random Distribution of RDPS (RDPS 분포가 랜덤한 분산 제어 광 링크에서 RDPS 편차에 따른 시스템 성능)

  • Lee, Seong-Real
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.967-970
    • /
    • 2014
  • The compensation characteristics are investigated as a function of the deviation of residual dispersion per span (RDPS) in the optical transmission links with a randomly distributed RDPS and optical phase conjugation (OPC). The simulation results show that the effective launch power are more increased and the effective net residual dispersions (NRDs) are more increased, as the deviation of RDPS is more narrow.

  • PDF

Reduction of the Number of Power States for High-level Power Models based on Clock Gating Enable Signals (클럭 게이팅 구동신호 기반 상위수준 전력모델의 전력 상태 수 감소)

  • Choi, Hosuk;Yi, Joonhwan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.9
    • /
    • pp.28-35
    • /
    • 2015
  • In this paper, we propose to identify redundant power states of high-level power model based on clock gating enable signals(CGENs) using dependencies of Boolean functions and structural dependencies of clock gating cells. Three functional dependencies between two CGENs, namely equvalence, inversion, and inclusion, are used. Functions of CGENs in a circuit are represented by binary decision diagrams (BDDs) and the functional relations are used to reduce the number of power states. The structural dependency appears when a clock gating cell drives another clock gating cells in a circuit. Automatic dependency checking algorithm has been proposed. The experimental results show the average number of power state is reduced by 59%.

A Study on the Power Factor Improvement of DC Power Regenerating Systems (직류전력 회생시스템의 역률개선에 관한 연구)

  • 김경원;윤인식;서영민;윤덕용;홍순찬
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.5
    • /
    • pp.410-415
    • /
    • 2001
  • This paper proposes a new control scheme for the power factor improvement of DC power regenerating systems, which can regenerate the excessive DC power from DC bus line to AC supply in substations for traction systems. From the viewpoint of both power capacity and switching losses, the system is designed on the basis of three-phase square-wave inverters and composed of two inverters, zig-zag connected output transformers, and an AC filter. The output voltages of the regenerating system are not sinusoidal. However, regenerated complex power is analyzed on the basis of fundamental components and thus the reactive power produced by harmonics is not considered. Therefore, it is needed a new control scheme capable of controlling the reactive power nearly to zero even for nonsinusoidal cases. To verify the validity of the proposed control scheme, computer simulations are carried out. And the results show that the power factor is theoretically higher than 0.99.

  • PDF

Regeneration Inverter System for DC Traction with Hormonic Reduction Capability (고조파 저감 능력을 가진 직류전철 회생인버터 시스템)

  • Won, Chung-Yuen;Jang, Su-Jin;Kim, Yong-Ki;Bang, Hyo-Jin;Song, Sang-Hun;Ahn, Kyu-Bok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.96-104
    • /
    • 2004
  • This paper proposes a dc power regenerating systems, which can generate the excessive dc power from dc bus line to ac supply in substations for traction system The proposed regeneration inverter system for dc traction can be used as both an inverter and an active power filter(APF). As an regeneration inverter mode, it can recycle regenerative energy caused by decelerating tractions and as an active power filter mode, it can compensate for harmonic distortion produced by the rectifier substation. From the viewpoint of both power capacity and switching losses, the system is designed on the basis of three phase PWM inverters and composed of parallel inverters, output transformers, and an LCL filter.

A Study on Adaptive Operation Control to Stabilize bus Voltage of GEO Satellite Power Supply Module (정지궤도 위성용 전력공급 모듈의 버스 전압 안정화를 위한 최적동작 제어에 관한 연구)

  • Ahn, Tae-Young;Choe, Hyun-Su
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.2
    • /
    • pp.123-129
    • /
    • 2016
  • In this paper, results of produced PCU(Power Control Unit) prototype was showed by suggesting and maintaining optimal operation status which let the three functional modules automatically operate with its necessity by prioritizing operation process. In order to validate effectiveness of the suggested method, we produced a test PCU and examined the results. PCU consists of S3R(Sequential Switching Shunt Regulator), BCR(Battery Charge Regulator), and BDR(Battery Discharge Regulator): converting photovoltaic power into constant voltage at linked bus voltage; storing dump power in the battery which is an auxiliary energy storage device; and supplying power charged in battery to the load. To maintain its high reliability and optimal condition of these three power conversion modules, each module operates in parallel and stable bus voltage is required to be retained at all-time due to the nature of power supply for satellite.

Double Encoder-Decoder Model for Improving the Accuracy of the Electricity Consumption Prediction in Manufacturing (제조업 전력량 예측 정확성 향상을 위한 Double Encoder-Decoder 모델)

  • Cho, Yeongchang;Go, Byung Gill;Sung, Jong Hoon;Cho, Yeong Sik
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.9 no.12
    • /
    • pp.419-430
    • /
    • 2020
  • This paper investigated methods to improve the forecasting accuracy of the electricity consumption prediction model. Currently, the demand for electricity has continuously been rising more than ever. Since the industrial sector uses more electricity than any other sectors, the importance of a more precise forecasting model for manufacturing sites has been highlighted to lower the excess energy production. We propose a double encoder-decoder model, which uses two separate encoders and one decoder, in order to adapt both long-term and short-term data for better forecasts. We evaluated our proposed model on our electricity power consumption dataset, which was collected in a manufacturing site of Sehong from January 1st, 2019 to June 30th, 2019 with 1 minute time interval. From the experiment, the double encoder-decoder model marked about 10% reduction in mean absolute error percentage compared to a conventional encoder-decoder model. This result indicates that the proposed model forecasts electricity consumption more accurately on manufacturing sites compared to an encoder-decoder model.