• Title/Summary/Keyword: 입자 영상 유동장 계측

Search Result 36, Processing Time 0.024 seconds

PIV를 이용한 만곡형 전개판의 가시화 실험

  • 박경현;이주희;배재현;현범수
    • Proceedings of the Korean Society of Fisheries Technology Conference
    • /
    • 2001.05a
    • /
    • pp.45-46
    • /
    • 2001
  • PIV(Particle Image Velocimetry : 입자영상유속계)는 유동장에 분포된 추종입자의 위치를 영상처리에 의해 자동추적 함으로써 속도벡터를 전유동영역에 걸쳐 동시에 구할 수 있는 계측기법이다. 따라서, CFD와 같이 정량적 및 정성적으로 수치해석된 결과와 바로 비교 검토가 가능한 유일한 실험기법으로 인식되고 있다. 본 실험에서는 CFD에 의한 모형의 유체유동 특성을 분석하고 이를 회류수조에서 PIV를 이용해 모형 전개판 주위의 유체흐름을 분석하여 각 전개판 모형의 유체유동 특성을 파악하였다. (중략)

  • PDF

Measurement of the Flow Field Around a Quadcopter in Vertical Descending Flight (수직 하강 비행 조건에서의 쿼드콥터 주위의 유동장 계측)

  • Kwon, Min-Jeong;Kwon, Ki-Jung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.5
    • /
    • pp.359-367
    • /
    • 2018
  • The vortex ring state that occurs during the descending flight of a rotorcraft generates a circulating flow like a donut near the rotating surface, and it often causes a rotorcraft fall due to loss of thrust. In this paper, we have physically identified the flow field in the vortex ring state of the quadcopter, one of the types of unmanned aerial vehicles. The descending flight of the quadcopter was simulated in a 1m subsonic wind tunnel of the Korea Aerospace Research Institute(KARI) and the Particle Image Velocimetry(PIV) was used for the flow field measurement. The induced velocity in the hovering state is estimated by using the momentum theory and the test was carried out in the range of descent rate at which the vortex ring condition could be caused. The development and the direction of the vortex ring were confirmed by the measurement of the flow field according to not only the descent rate but also propeller separation distance. In addition, the results of the study show the vortex ring state can be predicted sufficiently by measuring the flow velocity around the quadcopter.

Flow Characteristics of Rectangular Space with Asymmetric Inlet and Outlet (비대칭 입출구를 갖는 장방형공간의 유동특성)

  • Lee, Cheol-Jae
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.12 no.4 s.27
    • /
    • pp.261-266
    • /
    • 2006
  • In this study, a scaled model chamber was built to investigate ventilation characteristics of the hood room in LNG carrier. Experimental study was performed in model by visualization equipment with laser apparatus. Four different kinds of measuring area were selected as experimental condition Instant simultaneous velocity vectors at whole field were measured by 2-D PIV system and its software adopting two-frame grey-level cross correlation algorithm. The flow pattern reveals the large scale counter-clockwise forced-vortex rotation at center area.

  • PDF

PIV Measurement of Airflow in a Vertical Channel With Square Heat Source (정방형 발열체를 갖는 수직채널 내부의 공기유동 관한 PIV계측)

  • Bae, S.T.;Kim, D.K.;Kim, S.P.;Cho, D.H.;Lee, Y.H.
    • Solar Energy
    • /
    • v.17 no.3
    • /
    • pp.35-41
    • /
    • 1997
  • An experimental study was carried out in a vertical channel with square heat source by visualization equipment with laser apparatus. The image processing system consists of one commercial image board slit into a personal computer and 2-dimensional sheet light by Argon-Ion Laser with cylindrical lens and flow picture recording system. Instant simultaneous velocity vectors at whole field were measured by 2-D PIV system which adopted two-frame grey-level cross correlation algorithm. Heat source was uniform heat flux(5W). The obtained results show various flow patterns such as the kinetic energy distribution and the turbulent kinetic energy distribution.

  • PDF

Study on the Measurements of Flow Field around Cambered Otter Board Using Particle Image Velocimetry (PIV를 이용한 만곡형 전개판의 유동장 계측에 관한 연구)

  • 박경현;이주희;현범수;노영학;배재현
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.38 no.1
    • /
    • pp.43-57
    • /
    • 2002
  • This paper introduces an analysis method to predicting the flow characteristic of flow field around otter board In order to develope a high performance model. In this experiment, it is used a numerical analysis of flow field through CFD(Computational Fluid Dynamic), PIV method in which quantitative, qualitative evaluation is possible. In this experiment, it is used PIV method with flow filed image around otter board in order to analysis of flow characteristic. The result compared flow pattern with analysis result through CFD and also measurement result of lift and drag force coefficient carried out in CWC(Circulating Water Channel). The numerical analysis result is matched well with experiment result of PIV in the research and it is able to verify In the physical aspect. The result is as follows ; (1) It was carried out visibility experiment using laser light sheet, and picture analysis through PIV method in order to analysis fluid field of otter-board. As a result, the tendency of qualitative fluid movement only through the fluid particle's flow could be known. (2) Since PIV analysis result is quantitative, this can be seen in velocity vector distributions, instantaneous streamline contour, and average vorticity distributions through various post processing method. As a result, the change of flow field could be confirmed. (3) At angle of attack 24$^{\circ}$ where It Is shown maximum spreading force coefficient, the analysis result of CFD and PIV had very similar flow pattern. In both case, at the otter-board post edge a little boundary layer separation was seen, but, generally they had a good flow (4) As the result of post processing with velocity vector distributions, instantaneous streamline contour and average vorticity distributions by PIV, boundary layer separation phenomenon started to happen from angle of attack 24$^{\circ}$, and from over angle of attack 28$^{\circ}$, it happen at leading edge side with the width enlarged.

PIV Measurement on the Flows of PDP(Plasma Display Panel) (PDP 유동장 PIV 계측)

  • Doh, D.H.;Cho, G.R.;Pyun, Y.B.;Song, J.S.;Baek, T.S.;Jung, W.M.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.733-737
    • /
    • 2001
  • Heat generated from the electronic parts in PDP is undesirable physical properties. To attain optimal arrangement of the electronic parts in PDP, thermal flows in PDP should be analyzed. PIV measurement has been made to quantify the characteristics of the inner flows and outer flows of an actual PDP. The quantity of heat flux from PDP has been estimated using the PIV results. Measurement system consists of Ar-ion laser, CCD camera and an image grabber installed on a host computer.

  • PDF

Effect of Particle Loading Ratio on Fluid Characteristics and Particle Distribution in Particle-laden Coaxial Jet (입자부상 동축 분사기에서 입자로딩비가 유동 특성과 입자분포에 미치는 영향에 대한 연구)

  • Yoon, Jungsoo;Yoon, Youngbin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.3
    • /
    • pp.9-19
    • /
    • 2015
  • Experimental research on characteristics of particle-laden jet by using a coaxial injector was conducted in order to design fuel and oxidizer injectors of the supercavitation underwater vehicle. $1{\mu}m$ and $42{\mu}m$ particles was simultaneously injected to obtain particle and fluid velocity. Small particles($1{\mu}m$) and large particles represent fluid and fuel characteristics respectively. Small particles, which was processed using PIV algorithms, and one for the large particles processed using PTV algorithms. Fluid phase axial velocity increases according to particle loading ratio increases, and particles are located at the outside of the high vorticity region in a mixing layer of a coaxial injector.

PIV Measurement of Viscous Flow Field in the Wake of Transom Stern (PIV기법을 이용한 트랜섬 선미 후류 점성유동장 계측)

  • Lee, Gyoung-Woo;Gim, Ok-Sok
    • Journal of Navigation and Port Research
    • /
    • v.35 no.10
    • /
    • pp.805-810
    • /
    • 2011
  • An experiment was carried out to figure out the instantaneous flow characteristics in the wake of the transom stern's 2-dimensional section by 2-frame grey level cross correlation PIV method at $Re=3.5{\times}103$, $Re=7.0{\times}103$. The stern angles of models were learning at $45^{\circ}$(Model "A"), $90^{\circ}$(Model "B") and $135^{\circ}$(Model "C") respectively based on the survey results of real ships. The depth of wetted surface is 40mm from free surface. As Reynolds number increases, vortices increase in volume and move their way to the downstream. Flow separation appeared at the end of model's bottom.

A Study on PIV Measurement of Unsteady Flow around Disk caused by Slide Type Valve Quick Closing (슬라이드 밸브 급폐쇄에 따른 디스크 주위 비정상유동의 PIV계측에 관한 연구)

  • Lee, Chul-Jae;Cho, Dae-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.15 no.3
    • /
    • pp.251-256
    • /
    • 2009
  • In this research, we experimentally studied flow characteristic by applying PIV measuring techniques which could measure the point velocity of all flow field and measuring the unsteady velocity of surrounding disk generated in a short time. Time range of great velocity change following quick closing of the slide valve was within 0.1s and the cycle was presumed to be 0.12s as a result of comparison study between the result of point flow field and of existing pressure change. Also, surrounding disk flow inside the circular pipe was closed from the upper part and flow road was getting narrow and advanced to the lower part incidentally quickly there was a tendency that the size of the flow back velocity to the upper part immeadiately after the closure decreased to 4/120s and increased again. There was flow back velocity component in y/D=0.2 lower part by the influence of flow back to the upper part after complete closure and the vortex flow of 0.2D-size near y/D=0.7, x/D=-0.3 was observed.

  • PDF