• Title/Summary/Keyword: 입자운동분석장치

Search Result 12, Processing Time 0.028 seconds

Numerical Study on the Performance of the Round Type Impactor (원형 임팩터의 성능에 관한 수치적 연구)

  • 허재영;김상수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.1
    • /
    • pp.292-298
    • /
    • 1991
  • Previous studies on the performance of the round type impactor were reexamined and extended to the case of high particle mass loading. It was pointed out that the previous numerical studies need to be supplemented in the numerical process. The impactor performance was calculated under the same conditions as previous studies by the exact calculation process and it was found out that a tail of the collection efficiency curve, which have not been found in the previous studies, appeared in the results of ours. Numerical results for high particle mass loading show that the value of the collection efficiency in the impactor decreases but better particle-cut characteristics can be obtained, as the amount of the particle mass loading increases.

Study on the Fabrication of Porous Uranium Oxide Granule Using a Rotary Voloxidizer (회전형 휘발성 산화장치 이용 다공성 우라늄산화물 그래뉼 제조 연구)

  • Lee, Jae-Won;Yun, Yeo-Wan;Shin, Jin-Myeong;Lee, Jung-Won;Park, Guen-IL;Park, Jang-Jin
    • Applied Chemistry for Engineering
    • /
    • v.22 no.6
    • /
    • pp.642-647
    • /
    • 2011
  • The fabrication characteristics of porous uranium oxide granules from $U_3O_8$ powder was investigated in terms of initial particle bed motions such as slumping and rolling, thermal treatment conditions, and rotational velocities in slumping motion using a rotary voloxidizer. With respect to the initial particle bed motion the recovery rate of granule of above 1 mm in slumping motion was higher than that in the rolling motion. Rolling motion was changed into slumping motion with high slumping frequency by formation of granules from fine particles. Recovery rate of granule significantly increased with the increas in thermal treatment temperature and time of upto 10 h. As the rotational velocity of voloxidizer in the case of the initial particle bed showing slumping motion increased, the recovery rate of granule increased from 81.5 to 88.7%. However, the rotational velocity of 2 rpm provided an effective density, crushing strength and sphericity of granules.

Measurement of Physical Properties of Pepper for Particle Behavior analysis of sorting system for Pepper Harvester (고추수확기용 선별장치의 입자 거동 해석을 위한 고추 물성측정)

  • Byun, Jun Hee;Kim, Su Bin;Kim, Myoung Ho;Kim, Dae Cheol
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.9-9
    • /
    • 2017
  • 입자거동해석소프트웨어(EDEM)은 DEM(Discrete Element Method)기법을 이용한 입자 거동 전용 해석툴로 입자 유입량, 위치 등을 조절하여 입자거동과 관련된 제품 개발, 프로세스 최적화를 위한 비용 및 시간 절감에 활용도가 뛰어난 소프트웨어이다. EDEM을 활용하기 위해선 적용대상에 대한 물성치를 적용하여야 한다. 따라서 본 연구에서는 EDEM를 이용하여 현재 연구개발 중인 카드클리너 방식의 고추 선별기의 성능을 분석을 수행하기 위해 고추 물성측정 실험을 수행 하였다. EDEM을 이용한 입자거동해석에 필요한 개인 물성치에는 포아송비, 전단탄성계수, 밀도가 있다. 또한 입자-입자, 입자-Geometry 간의 상호관계를 위한 물성치인 반발계수, 정지마찰계수, 구름마찰계수가 필요하다. 공시 시료인 고추는 광주광역시 남구 승촌동 소재의 개인농가 Plastic 온실로 재배된 '천상'품종을 사용하였다. 푸아송 비와, 전단 탄성계수를 측정하기 위한 인장시험기기로는 만능인장시험기(TA-XT2, Stable Micro, 영국)를 이용하였으며, 인장에 의한 고추의 변형량 축정은 초고속카메라(NX4-SI, IDT, 미국)을 이용하였다. 밀도는 비중병법에 기초하여 질량과 부피를 측정하여 밀도를 계산하였다. 반발계수는 고추의 충돌 실험을 통해 변화한 높이를 이용하여 계산하였고, 충동 실험을 통해 변화한 높이는 초고속카메라를 이용하여 측정하였다. 정지마찰계수와 구름마찰계수는 고추의 미끄러짐이 시작하는 각도와 등속도 운동으로 구르는 각도를 초고속카메라를 이용하여 측정 후 계산하였다. 모든 실험은 3번 반복을 통해 평균값을 시험 결과 값으로 이용하였다. 고추의 대한 물성치 실험결과 고추의 푸아송 비는 0.294(std : 0.2), 전단탄성계수 4.624E+06 Pa, 밀도 $600kg/m^3$로 나타났다. 또한 입자-입자 간의 물성치인 반발계수는 0.383, 정지마찰계수는 0.455, 구름마찰 계수는 0.043로 나타났다. 추후 본 연구에서 측정한 고추의 물성치를 적용한 EDEM 입자거동해석 시뮬레이션을 통해 카드클리너 방식의 고추 선별기의 성능에 대한 분석을 하고자 한다.

  • PDF

Development of Optimal Design Program of Air-Coal Pneumatic Conveying System to Enhance Combustion Efficiency (연소효율 향상을 위한 공기-미분탄 수송배관장치의 최적화 설계 프로그램 개발)

  • Ku, Jae-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.5
    • /
    • pp.7-14
    • /
    • 2009
  • This study describes to analyze the pressure drop characteristics for the air-particle flow in pneumatic coal powder conveying system and to proper design of the orifice located in the system to enhance combustion efficiency in furnace of the coal-fired power plant. Usually the system consists of the straight type pipe, the curved type pipe and the elbow, which cause increase of the pressure drop. In this study, the pressure drop arised in the system with straight and curved type pipes is analyzed with interactions of motion of air flow and particles. It is realized that total pressure drop increases with increasing of the pipe length and the angle of curved type pipe due to friction loss of air and particles in the system. The program for analysis of the pressure drop and optimum design of the orifice size for air flow control in the system is developed. The result is also compared with the existing system.

  • PDF

A Statistical Study on the Blasting Conditions when Micro Blasting for Rotating Aluminum Rod (회전하는 알루미늄 환봉의 미세입자 분사가공시 통계적 방법에 의한 분사조건에 대한 연구)

  • Kwon, Dae Kyu;Wang, Duck Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.2
    • /
    • pp.135-141
    • /
    • 2017
  • An experimental study of micro blasting for a rotating aluminum rod was conducted through the statistical analysis of ANOVA to obtain the effect of blasting conditions. The rotating equipment was designed and constructed with forward and backward moving for helical blasting, but rotation was used in this study. The blasting condition factors were the type of abrasive particle, nozzle diameter, pressure, standoff distance, injection time, etc. The width of the surface, the maximum depth of the sprayed surface, and ANOVA were analyzed by statistical analysis. The results showed that the contributions of the main factors were pressure, nozzle diameter, and injection particle.

The Screen Efficiency Improving Effect Analysis by the Screen Motion Characteristic Analysis Applying Blockage Prevention Spring (막힘 방지 스프링 적용 스크린 운동 특성 분석을 통한 스크린 효율 개선 효과 분석)

  • Han-Sol Lee;Myouing-yuol Yu;Hoon Lee
    • Resources Recycling
    • /
    • v.31 no.6
    • /
    • pp.36-43
    • /
    • 2022
  • The general screen used to separate the particle size of recycled aggregate has restrictions when dealing with moisturized materials because of the blockage phenomenon. Therefore, in this study, to improve the separation efficiency of the conventional screen, the excellence of additional vibrating device based on spring was decided by a simulation experiment based on the discrete element method (DEM). The motion characteristic was investigated by analyzing the displacement, amplitude, and strain angle based on the spring design. Further, the particle motion was simulated by applying spring motion. The material flow and separation efficiency of the screen applied spring were confirmed as 9.2 kg/s and 97 %, respectively. Consequently, the improvement in the screen applied with blockage prevention spring was confirmed by comparing with the conventional screen.

A Study on Atomization Characteristics of Gasoline Impinging Spray Using Glow plug (글로우플러그를 이용한 충돌분무의 미립화특성에 관한 연구)

  • 문영호;오영택
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.5
    • /
    • pp.54-61
    • /
    • 2001
  • It is reported that during the cold starting, especially in gasoline engine, the engine response and the effect of HC emission can be improved by prompting atomization and reducing the quantity of fuel adhered to the range of injector tip, inlet port, and inlet valve. The purposes of this study are to promote atomization of fuel before air-fuel mixture in the inlet port. In order to achieve its goal, the glow plug is to evaluate the feasibility of for the early fuel evaporator and the spray behavior characteristics of gasoline, injected on the surface of glow plug with room temperature(2$0^{\circ}C$) and high temperature(25$0^{\circ}C$) is to examine. Particle motion analysis system(PMAS) was used to measure the SMD and the dropsize distribution of impinging spray and free spray. The results of this experiment, evaporation rate of impinging spray was higher than that of free spray, and the higher evaporation rate win, the smaller peak dropsize was. Especially, during early spray SMD of impinging spray was still smaller than that of fee spray.

  • PDF

Numerical experiment for compressible effects around a butterfly valve (Butterfly 밸브 주위에서의 난류유동의 압축성 현상에 관한 연구)

  • Kim, C. H.;;B. E. Milton
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.15 no.2
    • /
    • pp.105-111
    • /
    • 1993
  • 내연기관의 혼합 가스 생성 장치로 흡입되는 공기의 유량을 조절하기 위해 Butterfly 밸브가 사용 된다. 이 밸브는 유량의 제어에는 매우 유용한 반면, 밸브 후면에서의 복잡한 공기의 유동현상[6] 으로 인하여 혼합가스의 생성에 장해적인 요소를 제공하기도 한다. 특히 밸브가 많이 닫힌 상태 에서는 밸브와 관로벽 사이의 간격이 좁아지는 Throttling 현상으로 인하여, 엔진에 고 부하시 흡 입되는 공기의 양이 증가하게 되어, 밸브 주위에서 공기 속도의 급증으로 인하여 유동장의 압축 성 현상을 기대할 수 있다. Throttle의 Choking 현상으로 인하여 공기의 입자는 운동에너지를 잃 게 되고, 궁극적 혼합가스의 생성에 영향을 미쳐 엔진성능의 저하를 초래하게 된다. 본 연구에서 는 실제 엔진(Central Fuel Injection Engine, 5 liters) [1]의 흡인 manifold를 modelling하여, 특히 밸브가 많이 닫힌 상태에서, 밸브 주위에서의 난류 유동의 압축성 현상을 정량적으로 분석해 보았다.

  • PDF

Effect of Coagulants on the Behavior of Ultra Fine Dust in a Coal Firing Boiler (석탄 화력 보일러에서의 응집제 이용에 따른 초미세먼지 거동)

  • Ryu, Hwanwoo;Song, Byungho
    • Applied Chemistry for Engineering
    • /
    • v.31 no.1
    • /
    • pp.84-89
    • /
    • 2020
  • Particulate matters of PM2.5, particularly focusing on 0.1~1 ㎛ decrease the efficiency of dust-collector due to the brownian-motion. This study is to verify the effect of coagulant on the particle size distributions of potassium and PM2.5. The activated coagulant was spayed to the coal fired fluidized bed combustion boiler by the weight ratio of 1,200 : 1 = coal : coagulant, and the size distributions of captured particles at both the cyclone (FP) and electrostatic precipitator (EP) were measured. As the result of XRP analysis, the potassium content of FP increased to 13.33% (averagely from 1.65% to 1.87%) and, in EP at 17.68% (averagely from 1.65% to 2.03%). And it was confirmed by the particle size distribution analyzer and SEM image analysis that the distribution rates of PM2.5 decreased at 89.53% on average in FP, and at 88.57% in EP. The total dust concentration (mg/㎥) confirmed by tele-monitering system (TMS) decreased during the primary test from 2.6 to 1.7~1.9 and also the secondary test from 2.9 to 1.7~1.9.

A Study on the Fine Dust Removal Equipment of Pressurized Water type for the Removal of Exhaust Gas Fine Dust and Volatile Organic Compounds from the Non-industrial combustion plant (비산업 연소 사업장 배출 가스상 미세먼지와 휘발성 유기 화합물 제거를 위한 가압수식 미세먼지 제거 장치 연구)

  • Youn, Jae-Seo;Kim, Sang-Min;Lee, Ye-Ji;Noh, Seong-Yeo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.506-512
    • /
    • 2018
  • The fine dust generated in the home and restaurant business occupies a low ratio of about 4% of the total fine dust emissions. However, at the foodservice business, the rate of change of the pollutant concentration is very high, so that the temporary fine dust concentration can be measured up to 60 times. The pollutants generated from non-industrial combustion plants consist of particulate fine dust and gaseous organic compounds. To remove these pollutants, cleaning dust collection system, which is an effective system for simultaneous removal of gaseous and particulate matter, is applied. This is a method of increasing the probability of diffusion capture of the Brownian motion by pressurized liquid injection method using the atomizing nozzle. The dust removal efficiency of the fine dust collecting system was analyzed by nozzle spraying air pressure condition and angle using the manufactured fine dust removing system. As a result, it was confirmed that the efficiency of removal of fine dust and gaseous organic compounds was more than 90%. The developed system is expected to be highly usable in the future because it can remove particulate dust from the existing plant hood system without any installation cost.