• Title/Summary/Keyword: 입자빔

Search Result 146, Processing Time 0.024 seconds

Response Function of HPGe Detector using $^{23}Na$(p, $\gamma$)$^{24}Mg$ and $^{27}Al$(p, $\gamma$)$^{28}Si$ Reaction ($^{23}Na$(p, $\gamma$)$^{24}Mg$$^{27}Al$(p, $\gamma$)$^{28}Si$반응을 이용한 HPGe 검출기의 응답함수)

  • Park, Sang-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.2
    • /
    • pp.85-90
    • /
    • 2010
  • In the present work, peak relative efficiency for the energy was obtained and response function was worked out. This study was carried out using the high resolution high efficiency HPGe detector(diameter 78.7 mm, length 86.5 mm) and NaI(Tl) detector for anti-compton. The anti-coincidence of the signals from the two detectors could be used to lessen the Compton effect signal; thus, the $\gamma$-ray energy resolution could be improved. The $\gamma$-ray spectrum was measured at $55^{\circ}$ to the direction of the incident proton beam. Reaction spectrum was obtained from the $^{23}Na$(p, $\gamma$)$^{24}Mg$ reaction at $E_p$ = 1424 keV and $^{27}Al$(p, $\gamma$)$^{28}Si$ reaction at $E_p$ = 992 keV. To accelerate the incident proton which creates the (p, $\gamma$) capture reaction, the 3 MeV Pelletron accelerator at the Tokyo Institute of Technology was used. Response function was worked out by a noble technique. We worked out a response function from 1.2 to 9.4 MeV at intervals of 0.75 MeV.

Experimental Study on Hydraulic Characteristics and Vorticity Interactions of Floating Breakwaters (부유식방파제의 수리특성 및 와 상호작용에 관한 실험적 연구)

  • Yoon, Jae Seon;Cho, Yong-Sik
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.55-55
    • /
    • 2011
  • 연안 및 해안공학의 발달과 더불어 부유식방파제의 기능적 효율성이 중요시 되고 있다. 흔히 사용되어오던 착저식방파제는 설치에 많은 시간과 경비가 소요되고 환경 및 생태계에 많은 변화를 줄 수 있으며, 설치 예정지의 수리학적 특성 등의 여건에 많은 제약을 받는 단점이 있다. 부유식방파제는 일본 등의 선진국을 중심으로 활용이 잦아지고 있는 방파제로서 수면 위에 설치되기 때문에 수중 생태계에 미치는 영향이 적은 친환경방파제이다. 또한 기존에 시공된 중력식방파제와는 달리 수심에 제한을 덜 받고, 공사기간이 짧기 때문에 경제적이다. 실제 시공사례로는 2007년 마산 원전항에 완공된 부유식방파제가 대표적이며, 지금까지도 부유식방파제에 대한 여러 연구자들의 관심이 증가하고 있는 추세이다. 방파제뿐만 아니라 우리나라처럼 국토의 면적이 작은 지역에서 증가하는 해상물동량을 소화하기 위해서 부유식방파제 등을 이용한 항만의 시공이 필요한 실정이다. 이러한 부유식방파제의 분석적인 측면에 있어서 수치해석은 파랑과 구조물의 상호작용을 해석하는 데 한계가 있으며, 부유식방파제 단면형상을 정확하게 재현할 수 없으므로, 수리모형실험을 통한 부유식방파제의 연구가 필요할 것으로 판단된다. 최근 기술의 발달로 인한 유동장 해명이 가능해 졌으며, PIV(Particle image velocimetry) 및 LDV시스템은 다양한 분야에서 응용되고 있다. 특히, LDV시스템은 측정하려는 한 지점에 대하여 레이저 빔을 단면(Cross-section)으로 만들고 입자의 산란광을 후방산란(Back scatter)으로 받아서 도플러 효과를 이용, 속도에 대한 주파수를 획득하며, 유속을 측정하는 장비로 매우 높은 정확도와 비접촉식 이라는 장점을 가지고 있다. 또한, PIV 시스템에 비하여 측정시간이 오래 걸리는 반면 데이터를 가공하지 않고 활용할 만큼 높은 정확성을 가지고 있다. 본 연구에서는 수리모형실험을 통하여 단독형, 2열형 및 3열형 부유식방파제의 형상, 흘수 및 거리를 변화시키며 유동장을 수집하였으며, 방파성능에 따른 와의 생성 및 소멸시점에서의 파랑변형과의 관계를 분석하였다. 방파제의 형상과 흘수를 달리하여 수리모형실험을 수행하였으며, 와류의 상관관계를 분석하였다. 또한, 연직 2차원 Navier-Stokes 방정식 모형을 이용하여 수치모형실험을 수행하였으며, 수치모형실험 결과와 수리모형실험 결과를 비교 분석하였다. 후방방파제에서 발생되는 파랑은 입사파의 주기가 길어질수록 상대적으로 커지는 현상을 보였으며, 흘수심이 깊어질수록 전방방파제 입사 면에서 자유 수면이 높게 관측되는 결과를 보였다. 또한, 비교적 장주기파랑에 해당하는 입사파랑의 경우 전달파고비 산정에 있어서 설계기준인 0.5를 대다수 초과하는 반면, 3열형 구조에서는 대부분이 0.5이하로 상당히 높은 방파성능 결과를 나타내었다.

  • PDF

The Fabrication and Evaluation of HgI2 Semiconductor Detector as High Energy X-ray Dosimeter Application (고에너지 X선 선량계 적용을 위한 TiO2 첨가된 요오드화수은 반도체 검출기 제작 및 평가)

  • Choi, Il Hong;Noh, Sung Jin;Park, Jung Eun;Park, Ji Koon;Kang, Sang Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.383-387
    • /
    • 2014
  • In this paper, for a new detection system development with the better accurate dose evaluation and beam distribution imaging using the small field irradiation of linear accelerator, the compound semiconductor based detection sensors were fabricated and the performance evaluation was investigated. The special particle-in-binder sedimentation was used for a large area film sensor fabrication. The detection properties for high energy x-rays were investigated from a dark current, an output current, a rising time, a falling time, and response delay measurement. The experimental results, the $TiO_2$ mixed $HgI_2$ sensor showed the best electrical characteristics than $PbI_2$, PbO, pure $HgI_2$. Linearity, repeatability, and accuracy tests from LINAC were tested, the $TiO_2$ mixed $HgI_2$ sensor showed the better performance than the commercially available dosimetry devices.

Comparative Study of Optimization Algorithms for Designing Optimal Aperiodic Optical Phased Arrays for Minimal Side-lobe Levels (비주기적 광위상배열에서 Side-lobe Level이 최소화된 구조 설계를 위한 최적화 알고리즘의 비교 연구)

  • Lee, Bohae;Ryu, Han-Youl
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.1
    • /
    • pp.11-21
    • /
    • 2022
  • We have investigated the optimal design of an aperiodic optical phased array (OPA) for use in light detection and ranging applications. Three optimization algorithms - particle-swarm optimization (PSO), a genetic algorithm (GA), and a pattern-search algorithm (PSA) - were employed to obtain the optimal arrangement of optical antennas comprising an OPA. The optimization was performed to obtain the minimal side-lobe level (SLL) of an aperiodic OPA at each steering angle, using the three optimization algorithms. It was found that PSO and GA exhibited similar results for the SLL of the optimized OPA, while the SLL obtained by PSA showed somewhat different features from those obtained by PSO and GA. For an OPA optimized at a steering angle <45°, the SLL value averaged over all steering angles increased as the angle of optimization decreased. However, when the angle of optimization was larger than 45°, low average SLL values of <13 dB were obtained for all three optimization algorithms. This implies that an OPA with high signal quality can be obtained when the arrangement of the optical antennas is optimized at a large steering angle.

Characteristics and Quality Control of Precipitable Water Vapor Measured by G-band (183 GHz) Water Vapor Radiometer (G-band (183 GHz) 수증기 라디오미터의 가강수량 특성과 품질 관리)

  • Kim, Min-Seong;Koo, Tae-Young;Kim, Ji-Hyoung;Jung, Sueng-Pil;Kim, Bu-Yo;Kwon, Byung Hyuk;Lee, Kwangjae;Kang, Myeonghun;Yang, Jiwhi;Lee, ChulKyu
    • Journal of the Korean earth science society
    • /
    • v.43 no.2
    • /
    • pp.239-252
    • /
    • 2022
  • Quality control methods for the first G-band vapor radiometer (GVR) mounted on a weather aircraft in Korea were developed using the GVR Precipitable Water Vapor (PWV). The aircraft attitude information (degree of pitch and roll) was applied to quality control to select the shortest vertical path of the GVR beam. In addition, quality control was applied to remove a GVR PWV ≥20 mm. It was found that the difference between the warm load average power and sky load average power converged to near 0 when the GVR PWV increased to 20 mm or higher. This could be due to the high brightness temperature of the substratus and mesoclouds, which was confirmed by the Communication, Ocean and Meteorological Satellite (COMS) data (cloud type, cloud top height, and cloud amount), cloud combination probe (CCP), and precipitation imaging probe (PIP). The GVR PWV before and after the application of quality control on a cloudy day was quantitatively compared with that of a local data assimilation and prediction system (LDAPS). The Root Mean Square Difference (RMSD) decreased from 2.9 to 1.8 mm and the RMSD with Korea Local Analysis and Precipitation System (KLAPS) decreased from 5.4 to 4.3 mm, showing improved accuracy. In addition, the quality control effectiveness of GVR PWV suggested in this study was verified through comparison with the COMS PWV by using the GVR PWV applied with quality control and the dropsonde PWV.

Quantitative Elemental Analysis in Soils by using Laser Induced Breakdown Spectroscopy(LIBS) (레이저유도붕괴분광법을 활용한 토양의 정량분석)

  • Zhang, Yong-Seon;Lee, Gye-Jun;Lee, Jeong-Tae;Hwang, Seon-Woong;Jin, Yong-Ik;Park, Chan-Won;Moon, Yong-Hee
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.42 no.5
    • /
    • pp.399-407
    • /
    • 2009
  • Laser induced breakdown spectroscopy(LIBS) is an simple analysis method for directly quantifying many kinds of soil micro-elements on site using a small size of laser without pre-treatment at any property of materials(solid, liquid and gas). The purpose of this study were to find an optimum condition of the LIBS measurement including wavelengths for quantifying soil elements, to relate spectral properties to the concentration of soil elements using LIBS as a simultaneous un-breakdown quantitative analysis technology, which can be applied for the safety assessment of agricultural products and precision agriculture, and to compare the results with a standardized chemical analysis method. Soil samples classified as fine-silty, mixed, thermic Typic Hapludalf(Memphis series) from grassland and uplands in Tennessee, USA were collected, crushed, and prepared for further analysis or LIBS measurement. The samples were measured using LIBS ranged from 200 to 600 nm(0.03 nm interval) with a Nd:YAG laser at 532 nm, with a beam energy of 25 mJ per pulse, a pulse width of 5 ns, and a repetition rate of 10 Hz. The optimum wavelength(${\lambda}nm$) of LIBS for estimating soil and plant elements were 308.2 nm for Al, 428.3 nm for Ca, 247.8 nm for T-C, 438.3 nm for Fe, 766.5 nm for K, 85.2 nm for Mg, 330.2 nm for Na, 213.6 nm for P, 180.7 nm for S, 288.2 nm for Si, and 351.9 nm for Ti, respectively. Coefficients of determination($r^2$) of calibration curve using standard reference soil samples for each element from LIBS measurement were ranged from 0.863 to 0.977. In comparison with ICP-AES(Inductively coupled plasma atomic emission spectroscopy) measurement, measurement error in terms of relative standard error were calculated. Silicon dioxide(SiO2) concentration estimated from two methods showed good agreement with -3.5% of relative standard error. The relative standard errors for the other elements were high. It implies that the prediction accuracy is low which might be caused by matrix effect such as particle size and constituent of soils. It is necessary to enhance the measurement and prediction accuracy of LIBS by improving pretreatment process, standard reference soil samples, and measurement method for a reliable quantification method.