• Title/Summary/Keyword: 임플란트 핸드피스

Search Result 6, Processing Time 0.02 seconds

The comparative study of user satisfaction on various implant engine system (다양한 임플란트 엔진 시스템에 대한 사용자 만족도 비교)

  • Lee, Du-Hyeong;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.9-15
    • /
    • 2014
  • Purpose: Implant engine system is composed of the handpiece, micromotor, control box and foot switch. The aim of this study was to evaluate the satisfaction of the implant engine systems in terms of convenience-design and to examine the relation with the experience of implant surgery. Materials and Methods: Three implant systems were evaluated: SurgicXT/X-SG20L, INTRAsurg300/CL3-09, XIP10/CRB26LX. For this comparative study, 30 dentists were included and the satisfaction was measured using a structured questionnaire. One-way analysis of the variance (ANOVA) and multiple regression analysis were used within and between the groups. Results: Total satisfaction differed from each other (P < 0.05). The convenience score was more associated with the total satisfaction than design score. Moreover, the implant surgery experience affected several assessments. Conclusion: Collectively, in a cross-sectional study model, the design of implant system significantly affects its total satisfaction and the surgery experience can be influential factor in the evaluation of implant engine system.

The effect of guided flapless implant procedure on heat generation from implant drilling (수술가이드를 이용한 무피판 임플란트 술식에서 임플란트 드릴링이 열발생에 미치는 효과)

  • Yoo, Je-Hyeon;Jeong, Seung-Mi;Choi, Byung-Ho;Joo, Sang-Don
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.11-19
    • /
    • 2013
  • Purpose: The aim of this study was to evaluate the heat generation in bone in vitro during the guided flapless drilling procedure and the effect of drilling methods on the heat generation. Materials and methods: A model that has missing the first and second mandibular molars bilaterally was used. In group A, classical flap implant surgery was performed. In group B, flapless implant surgery using surgical guide was performed. In group C, flapless implant surgery using surgical guide without up-and-down pumping motion was performed. Temperature was measured with k-type thermocouple and a real-time digital thermometer. The thermocouples were placed at 0.5 mm away from the osteotomy area at the depths of 3 mm and 6 mm. The measured values were evaluated with independent t-test. Results: The mean temperature generated was $27.2^{\circ}C$ ($SD{\pm}2.1^{\circ}C$) and $27.5^{\circ}C$ ($SD{\pm}2.3^{\circ}C$) for groups A and B, respectively. These differences were not statistically significant. In group C, the mean temperature was $37.0^{\circ}C$ ($SD{\pm}3.4^{\circ}C$). There were statistically significant differences between groups B and C with respect to the mean temperature. Conclusion: These findings suggest that guided flapless drilling with up-and-down pumping motion may not significantly increase the bone temperature.

Study of heat transfer to the implant-bone interface induced by grinding of occlusal surface of implant gold prosthesis (금 합금 보철물의 교합면 삭제로 인한 임플란트-골 계면으로의 열전달에 관한 연구)

  • Jo, Jae-Young;Kang, Sun-Nyo;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo;Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.29-35
    • /
    • 2012
  • Purpose: The purpose of this study was to analyze temperature change along the implant-bone interface induced by grinding the occlusal surface of implant gold prosthesis and to compare the temperature generated by grinding of prosthesis with different cooling methods. Materials and methods: The experimental gold prostheses were fabricated with dental gold alloy and castable abutment. The prostheses had 3 cylindrical protrusions on the occlusal surface with 1mm in height. Temperature was measured using 16 thermocouple wires attached to the implant fixture surface and the fixture was embedded in an acrylic resin block inside the $37^{\circ}C$ water bath. Cylinders were grinded for a period of 30 second with a low-speed handpiece with green stone point. One cylindrical protrusion was grinded without cooling, the second one was grinded with air blow, and the third one was grinded with water-spray. Results: The mean maximum temperature was measured more than $47^{\circ}C$ of the implant and the maximum temperature was measured at the cervical portion of the implant in the group without cooling. There was statistically significant difference between the group without cooling and the groups with cooling (P<.05). However, there was no significant difference at all portion of implant in the groups with cooling (P>.05). Conclusion: The results of this study support that the grinding of implant gold prosthesis without cooling may damage the peri-implant tissue. The continuous use of air blow and water-spray adjacent to prosthesis during the grinding of implant gold prosthesis may prove to be beneficial for cooling of the implant.

Comparison of Implant Torque Controllers using Detorque Value (풀림토크를 이용한 임플란트 토크조절기의 비교)

  • Huh, Yoon-Hyuk;Cho, Lee-Ra;Kim, Dae-Gon;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.419-432
    • /
    • 2010
  • Various torque generating devices have been developed and employed to apply a proper torque. These devices are usually calibrated by the manufacturer to apply appropriate torque levels for their specific implants and attachments. The purpose of this investigation was to determine and compare the accuracy of the torque controllers. In this study, 4 types of torque controllers were used; torque limiting device(TLD), torque indicating device(TID) and contra angle torque driver(CA), electronic torque controller(ETC). Digital torque gauge was employed to measure the de-torque value. Thirty cycles of tightening and loosening were repeated with each torque controller. All implant torque controllers have shown slight errors and deviations. The contra angle torque driver exhibited the most accurate data. In the limitation of this study, it would be recommended that the implant torque controllers should be checked whether uniformed and precise torque can be generated and a measuring error should be corrected.

Temperature change and performance of bur efficiency for two different drill combinations (두 가지 임플란트 드릴 조합에 따른 온도 변화 및 효율 비교)

  • Hwang-Bo, Heung;Park, Jae-Young;Lee, Sang-Youn;Son, Keunbada;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.143-151
    • /
    • 2022
  • Purpose. The purpose of this study was to evaluate the performance efficiency of two different drill combinations according to the heat generated and drilling time. Materials and methods. In this study, cow ribs were used as research materials. To test the specimen, cow bones were rid of fascia and muscles, and a temperature sensor was mounted around the drilling area. The experimental group was divided into a group using a guide drill and a group using a Lindmann drill according to the drill used before the initial drilling. The drilling sequence of the guide drilling group is as follows; guide drill (ø 2.25), initial drill (ø 2.25), twist drill (ø 2.80), and twist drill (ø 3.20). The drilling sequence of the Lindmann drilling group is as follows; Lindmann drill (ø 2.10), initial drill (ø 2.25), twist drill (ø 2.80), and twist drill (ø 3.20). The temperature was measured after drilling. For statistical analysis, the difference between the groups was analyzed using the Mann-Whitney U test and the Friedman test was used (α = .05). Results. The average performance efficiency for each specimen of guide drilling group ranged from 0.3861 to 1.1385 mm3/s and that of Lindmann drilling group ranged from 0.1700 to 0.4199 mm3/s. The two drill combinations contained a guide drill and Lindmann drill as their first drills. The combination using the guide drill demonstrated excellent performance efficiency when calculated using the drilling time (P < .001). Conclusion. Since the guide drill group showed better performance efficiency than the Lindmann drill group, the use of the guide drill was more suitable for the primary drilling process.

Syncope and pneumomediastinum during the maxillary sinus elevation with an air-syringe: a case report (주사기를 이용한 상악동 거상술 시 발생한 실신 및 종격동기종에 관한 증례보고)

  • Kim, Su Wan;Lee, Jonggeun;Song, Ji-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.3
    • /
    • pp.171-176
    • /
    • 2021
  • Pneumomediastinum is a very rare and potentially catastrophic complication of dental procedures. Its common causes are tooth extraction, endodontic treatment, and subgingival curettage using handpieces and high-pressure air/water syringes. We present a case of massive pneumomediastinum with subcutaneous emphysema in a 61-year-old female who underwent bone grafting into the maxilla for pretreatment of dental implantation using a syringe. The patient suffered from abrupt severe odynophagia and loss of consciousness. The patient transferred to emergency department and images work-up revealed a pneumomediastinum and subcutaneous emphysema on the entire face and neck. We performed conservative treatments including prophylactic antibiotics, oxygen inhalation, and fasting meals, and then discharge after 7 days uneventfully. The patient's syncope might be resulting from hypotension and pain shock induced by pneumomediastinum with a sudden chest compression. The pneumomediastinum could be resulting from concurrent perforation and massive air infiltration into the maxillary sinus during bone grafting. We suggest that pneumomediastinum needs prompt diagnosis and management because of the risk of airway obstruction when a patient present syncope in the dental room.