• Title/Summary/Keyword: 임플란트 종류

Search Result 87, Processing Time 0.043 seconds

Structural Design of a Dental Implant (I): Comparative Structural Analysis (치과용 임플란트 구조설계 (1): 구조해석 비교연구)

  • Kwon, Young-Joo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.5
    • /
    • pp.421-432
    • /
    • 2012
  • This paper is the first paper among two papers which constitute the paper about the structural design of a dental implant. This paper surveyed types and characteristics of dental implants. Merits and shortcomings of clinically used dental implants were analysed through this survey. A new structural model of dental implant was proposed on the basis of survey results. Especially, a comparative structural analysis of the new dental implant and the well known dental implants has been performed using the finite element analysis method. The analysis results confirm that the newly proposed dental implant has a good structural performance. The well known dental implants used for the comparative structural analysis are 3i implant and Sargon implant. These implants are imported dental implants and we could know that most implants clinically used are endosteal implants and these two implants(3i implant and Sargon implant) are also endosteal implants.

Types and Distribution of Implant Dental Clinic Patients in Busan Area (부산지역 치과환자의 임플란트 유형 및 분포 경향)

  • Lee, Mi-Ok;Yoon, Hyun-Seo
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.8
    • /
    • pp.274-282
    • /
    • 2010
  • The purpose of this study was to examine the types of implant, the type of bone graft, periodontal status and the distribution of implant among patients in a region. The subjects in this study were 299 patients who received implant treatment Busan area. The number of their implants was 871 in total. The findings of the study were as follows: As for the type of implant, home-made implants accounted for 83.6 percent, and imported ones represented 16.4 percent. Regarding bone graft, The presence or absence of disease made a significant difference to that($x^2$=14.66, p<.01). As to periodontal status by gender, age and disease, the periodontal state was better among those who were female(y=-2.73, p<.01), who were younger(F=14.20, p<.001) and who had no disease(t=-4.67, p<.001). The intergroup gaps were statistically significant. Concerning the distribution of implant, The distribution of implant was statistically significantly different($x^2$=33.14, p<.01). Age made a statistically significant difference to that($x^2$=74.09, p<.001). As to links between periodontal status and the number of implant, The intergroup gaps were statistically significant($x^2$=38.28, p<.01).

Detorque Values of Various Compatible Dental Implant Screws (호환 가능한 수종의 치과용 임플란트 나사의 풀림토크값에 대한 연구)

  • Lee, Ju-Ri;Lee, Dong-Hwan;Hwang, Jae-Woong;Choi, Jung-Han
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.273-283
    • /
    • 2010
  • This study evaluated the effect of 3 different compatible screws on the detorque values in a multiple implant-supported superstructure and single implant abutments. An implant superstructure directly connected to 4 implants was screwed to 6 experimental dental stone casts made by acrylic resin splinted impressions, using 20 Ncm. The detorque values of screws were measured twice. Three compatible abutment screws used in this study were TorqTite screw, Gold-Tite screw, and, Titanium screw. And, using single implant abutments (GoldAdapt Engaging abutments), the detorque values of 3 different screws were measured twice on 2 implants of 5 experimental casts. According to statistical analysis of detorque values using mixed model at a .05 level of significance, no statistically significant differences among 3 different compatible screws were found in a multiple implant-supported superstructure (p>0.05). But, in single implant abutments, statistically significant differences among 3 different compatible screws were found (p=0.0175). The detorque values of TorqTite(p=0.0462) and Titanium(p=0.0348) screws were significantly higher than those of Gold-Tite screw, but no statisticantly significantlydifferences were found between TorqTite and Titanium screws(p>0.05). Therefore, various compatible screws showed significant effects on the detorque values for single implant abutment, but, showed no significant effects for a multiple implant-supported superstructure.

In Vitro Study on the Initial Stability of Two Tapered Dental Implant Systems in Poor Bone Quality (연질 골에서 두 종류의 테이퍼 형태 임플란트의 초기 안정성에 관한 실험실적 연구)

  • Kim, Duck-Rae;Kim, Myung-Joo;Kwon, Ho-Beom;Lee, Seok-Hyung;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.391-401
    • /
    • 2009
  • The successful outcome of dental implants is mainly the result of intial implant stability following placement. The aim of this study was to investigate the effect of a self-tapping blades and implant design on initial stability of two tapered implant systems in poor bone quality. The two different implant systems included one with self-tapping blades and one without self-tapping blades. D4 bone model using Solid Rigid Polyurethane Form was used to simulate poor bone densities. The insertion torque during implant placement was recorded. Resonance frequency Analysis (RFA), measured as the implant stability quotient (ISQ), was assessed immediately after insertion. Finally, the implant-bone specimen was transferred to an Universal Testing Machine to measure the axial pull-out force. Insertion torque values and maximum pull-out torque value of the non self-tapping implants were significantly higher than those in the self-tapping group (P = 0.008). No statistically differences were noted between the two implant designs in RFA. Within the each implant system, no correlation among insertion torque, maximum pull-out torque and RFA value could be determined. Higher insertion torque of the non-self-tapping implants appeared to confirm higher clinical initial stability. In conclusion, implants without self-tapping blades have higher initial stability than implants with self-tapping blades in poor bone quality.

Influence of varying cement types and abutment heights on pull-off force of zirconia restorations (시멘트의 종류 및 임플란트 지대주 높이가 지르코니아 수복물의 제거력에 미치는 영향)

  • Yeong-Jun Jung;Yu-Lee Kim;Ji-Hye Jung;Nae-Un Kang;Hyun-Jun Kong
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.2
    • /
    • pp.64-71
    • /
    • 2024
  • Purpose: The purpose of this study is to evaluate Ti-base abutment's three different heights and three different cement types on the pull-off force of zirconia-based restorations. Materials and Methods: A total of 90 fixture lab analogs were embedded in auto polymerizing resin bloack. 90 Ti-base abutments heights of 3 mm, 5 mm, 7 mm were scanned and zirconia restoration were prepared from scanned files. Zirconia restoration were cemented with three different types of cements (temporary, semi-permanent, permanent) following manufacturer's instructions. All 90 specimens were placed and tested in a universal testing machine for pull-out testing. Retention was measured by recording the force at load drop. Statistical analysis was performed using Kruskal-Wallis test for detecting whether there are any statistical significance along cement types or abutment heights. After that, Mann-Whitney test was used for figuring out differences regarding abutment height and the comparison between 3 cements. Results: Temp bond showed significantly lower pull-off force compared to Fujicem regardless of any abutment height. However, there were significant differences between Cem-implant and Fujicem in abutment height of 3 mm and 7 mm, but there was no significant difference in 5 mm. Temp bond and Cem-implant had significant differences only in abutment height of 5 mm. Conclusion: Although Ti-base abutment height did not influenced zirconia restorations' retentiveness, cement types showed significant differences.

Effect of attachments and palatal coverage of maxillary implant overdenture on stress distribution: a finite element analysis (상악 임플란트 피개의치에서 유지장치 종류와 구개 피개 유무에 따른 응력분포에 대한 유한요소분석)

  • Park, Jong-Hee;Wang, Yuan-Kun;Lee, Jeong-Jin;Park, Yeon-Hee;Seo, Jae-Min;Kim, Kyoung-A
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.70-79
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the effect of attachments and palatal coverage on stress distribution in maxillary implant overdenture using finite element analysis. Materials and Methods: Four maxillary overdenture 3-D models with four implants placed in the anterior region were fabricated with computer-aided design. 1) Ball-F: Non-splinted ball attachment and full palatal coverage, 2) Ball-P: Non-splinted ball attachment and U-shaped partial palatal coverage, 3) Bar-F: Splinted milled bar attachment and full palatal coverage, 4) Bar-P: Splinted milled bar attachment and U-shaped partial palatal coverage. Stress distribution analysis was performed with ANSYS workbench 14. 100 N vertical load was applied at the right first molar unilaterally and maximum stress was calculated at the implant, peri-implant bone and mucosa. Results: The use of the ball attachment showed lower maximum stress on implant and peri-implant bone than the use of the milled bar attachment. But it showed contrary tendency in the mucosa. Regardless of attachment, full palatal coverage showed lower maximum stress on implant, peri-implant bone and mucosa. Conclusion: Within the limitation of this study, ball attachment improved stress distribution on implant and peri-implant bone rather than milled bar attachment in maxillary implant overdenture. Also, full palatal coverage is more favorable in stress distribution.

Evaluating usability of and satisfaction with two types of dental CAD software (두 종류 치과 임플란트 캐드 소프트웨어의 사용자 편의성 및 만족도 비교)

  • Kim, Seong-Min;Lee, Wan-Sun;Son, Keunbada;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.1
    • /
    • pp.11-19
    • /
    • 2019
  • Purpose: This study evaluated the usability of and satisfaction with two types of computer-aided design (CAD) software among users who had experience with dental implant CAD software and those who did not. Materials and Methods: Dental technicians (n = 20) who had previous experience with dental implant CAD Software and students from the College of Dentistry (n = 12) who had never designed implant custom abutments were asked to evaluate two types of CAD Software, Exocad and Deltanine. In addition, the participants were asked to fill out a structured questionnaire (Section 1: Entering basic information and retrieving files; Section 2: Setting conditions before abutment design; Section 3: Setting abutment design; and Section 4: Overall satisfaction). For the statistical analysis of the collected data, Mann-Whitney U test was used (${\alpha}=.05$). Results: The ease of design and satisfaction with the implant CAD Software, evaluated with respect to 21 statements divided into four Stages, were significantly higher for Exocad in both groups for Secion 1. For Sections 2 and 3, participants with experience evaluated Deltanine to be significantly better. For Section 4, both groups evaluated Exocad Software to be better. Conclusion: Overall, the Exocad Software was evaluated as having better usability and offering greater satisfaction. However, in terms of performance in the core of the design process, i.e. Sections 2 and 3, Deltanine was rated higher by the experienced users. Thus, if the user interface design parts are supplemented, Deltanine CAD Software could be put to a wider use in clinics.

Three Dimensional Finite Element Analysis on Stress Distribution According to the Bucco-lingual Inclination of the Implant Fixture and Abutment in the Mandibular Posterior Region (하악 구치부에서 임플란트 고정체와 지대주의 협설 기울기에 따른 응력분포에 관한 삼차원 유한요소 분석)

  • Lee, Hyun-Sook;Kim, Ji-Youn;Kim, Ye-Mi;Kim, Myung-Rae;Kim, Sun-Jong
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.4
    • /
    • pp.371-392
    • /
    • 2011
  • The purpose of this study was to comparatively analyze the stress distribution according to the inclinations of abutments and angulations of the implant fixtures under occlusal loading force. Three study models with straight and $15^{\circ}$ and $25^{\circ}$-angled abutments were prepared following the insertion of Implants parallel to the long axis of the tooth. Additional two experimental models were fabricated with $15^{\circ}$ and $25^{\circ}$ fixture inclinations. Using ANSYS 11, a finite element analysis program, the magnitudes of stress distribution were analyzed. The magnitude of stress under loading was lowest when the load was applied vertically onto the axis of implant. And the magnitude of stress under compound(vertical+oblique) loading was increased as the inclination of implant abutment and fixture was increase. But, the distribution of stress was different as the loading conditions, because of the horizontal offset. As the offset between the axis of loading and the central axis of the implant increased, the stress was increased.