• Title/Summary/Keyword: 임성

Search Result 334, Processing Time 0.024 seconds

A Study of Power Quality Monitoring System Using Web Technology (웹 기술을 이용한 전기품질 감시시스템 연구)

  • Lee, K.S.;Lim, S.I.;Lee, S.J.;Lee, D.W.;Park, D.H.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.148-150
    • /
    • 2003
  • A meaning of power quality has changed, which affects on an environmental change of existing electricity supply markets. Today, it should take both consumers and suppliers into consideration to develop information and communication technology and to increase the use of power and electronic equipments. As a result, it is necessary to develop a system to monitor power quality and to display data. In this paper, a system, as a power quality monitoring equipment, which can use protective replays with progress of microprocessor technology and provide information in the intranet/internet circumstances using web-based architecture is described.

  • PDF

Data Compression using Waveform Comparison (파형 비교를 이용한 데이터 압축 기법)

  • Sung, S.M.;Lim, S.I.;Lee, S.J.;Bae, Y.J.;Jin, Y.W.;Kim, J.H.;Kim, B.J.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.151-153
    • /
    • 2003
  • This paper was studied on using data of the protective relay by Power Quality Monitor. The protective relay will have problem to save data for PQM(Power Qualify Monitoring) analysis because the protective relay memory is limited. So this paper was proposed new data compression of the data was get from the protective relay. The scheme is compared each cycle after DFT(Discrete Fourier Transform). And scheme is verified through simulation of protective relay data was from real distribution system.

  • PDF

Processing Conditions of Low Salt Fermented Squid and its Flavor Components 1. Volatile Flavor Components of Low Salt Fermented Squid (저염 오징어젓갈 제조 방법 및 향미성분 1. 저염 오징어젓갈의 휘발성 향기성분)

  • 최성희;임성임;허성호;김영만
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.24 no.2
    • /
    • pp.261-267
    • /
    • 1995
  • Low-salted and fermented squid product, squid jeotkal was prepared with the addition of 10% salt and fermented for 50 day at 1$0^{\circ}C$. During fementation of squid, sensory evaluation and changes of volatile components were examined. Volatile flavor components in raw squid and low-salted squid jeotkal were extracted using a rotary evaporating system. The volatile concentrates were identified by GC and GC-MS. Major volatile components of raw squid were methional and 2-methyl-2-propanol. However, alcohols such as propanol, isoamyl alcohol, methionol and phenylethyl alcohol increased during the period of fermentation. The model reaction using microorganism was carried out, in order to confirm formation mechanism ofvolatile flavor compounds of the squid during fermentation. The main volatile components of Pseudomonas sp. D2 model system were isoamyl alcohol and acetoin. Those of Staphylococcus xylosus model system were isoamyl alcohol and phenylacetaldehyde.

  • PDF

purification of Fungal Protease Produced by Mucor racemosus f. racemosus PDA 103 from Korean Traditional Meju (재래식 메주로부터 분리한 Mucor racemosus f. racemosus PDA 103 유래 Fungal Protease의 정제)

  • 임성일;유진영
    • Microbiology and Biotechnology Letters
    • /
    • v.27 no.6
    • /
    • pp.446-451
    • /
    • 1999
  • The protease produced by Mucor racemosus f. racemosus PDA 103 from meju was purified by precipitating with 80% saturated ammonium sulfate, CM Sephadex C-50 ion-exchange chromatography, and secondary Sephadex G-100 gel filtration chromatography. The specific activity of the purified enzyme was 60.1unit/mg protein and the purification fold of the enzyme was 83.5. The molecular weight of the enzyme was estimated 33,746Da and the enzyme was elucidated as monomer by LC-MS and SDS-PAGE. The number of amino acids was evaluated about 330 residues.

  • PDF

A Study on the Protective Coordination and Automatic Setting Method using Agents in Distribution System with Loop (루프 배전계통에서 Agent를 이용한 보호협조 및 자동정정 방법에 관한 연구)

  • Jin, Young-Taek;Lee, Seung-Jae;Choi, Myeon-Song;Lim, Seong-Il;Kim, Wan-Tae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.8
    • /
    • pp.1107-1114
    • /
    • 2012
  • In this paper, we propose protective coordination and automatic setting method using agents for distribution system with loop. The proposed protection scheme adopts an agent technology assuming communication among protection agents and auto-switch agents. Having exchanged fault-related information with each other, protection agents and auto-switch agents perform the primary and backup protection and fault section isolation, respectively. this proposed scheme using agents for distribution system with loop is implemented by matlab. Because of the various configuration of distribution system, It's difficult to find cooperative agents for each agent. This paper develops a program to automatically set the cooperative route for the agents.

Optimal protection by using Parametric Protection Ability Index (파라미터를 이용한 배전계통 보호능력 평가 및 최적화)

  • Shin, J.H.;Hyun, S.H.;Lim, S.I.;Lee, S.J.;Choi, I.S.;Jin, B.G.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.202-204
    • /
    • 2003
  • This paper suggests an optimal parameter setting method by use of parametric protectability index, as the objective function. In this paper, a gradient based optimization method is used under the assumption that the initial values of a parameter is in a convex set including the optimal value, which is verified by a plenty of simulation studies. The proposed method is applied to a sample distribution network to shows its effectiveness.

  • PDF

Faulted Section Identification Method in The Distribution Systems with Renewable Energy Resources (신재생 에너지 전원을 고려한 배전선로 고장구간 판단 기법)

  • Lee, Han-Seong;Jeon, Cheol-Woo;Kim, Young-Kook;Lim, Seong-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.10
    • /
    • pp.1321-1327
    • /
    • 2014
  • Faulted section identification is one of the most important function in distribution automation systems. Conventional over current detection based fault indicators frequently mal-operate due to the reverse fault current from the renewable energy resources. This paper present a new faulted section identification method based on the fuzzy decision making technique. In order to establish feasibility of the proposed method, case studies using Matlab Simulink has been performed.

Load Balancing Technique to Release Multiple Overloading of Distribution Feeders using Minimum Spanning Tree (최소신장트리를 이용한 배전선로 다중 과부하 해소 방법)

  • Oh, Seong-Hyeon;Lee, Han-Seong;Kim, Young-Kook;Lim, Seong-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.2
    • /
    • pp.33-39
    • /
    • 2015
  • Power supplying capacity of the distribution feeder should be maintained within thermal capacity of the wire. This paper presents the minimum spanning tree based load balancing technique to release multiple overloading of distribution feeders. In order to minimize number of involved backup feeders, Dijkstra and Prim algorithm are adopted to construct minimum spanning tree. Simulation testing result based on part of KEPCO's commercial distribution systems shows effectiveness of proposed scheme.

A Reliability Enhancement Methodology of the IEC61850 based Substation Automation System (IEC61850 기반 변전소자동화시스템인 신뢰도 향상기법)

  • Lim, Seong-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.75-81
    • /
    • 2008
  • The effect of the fault could be propagated to healthy region when the fault on the power system is not cleared in time. In order to enhance reliability of the protective relay, a dual and/or backup system is adopted for the power system protection. The IEC61850 has become an international standard of the substation automation system for interoperability between heterogeneous IEDs from different vendors. This paper introduces a reliability enhancement technique for the substation automation system using characteristics of the IEC61850.

CIM based Distribution Automation Simulator (CIM 기반의 배전자동화 시뮬레이터)

  • Park, Ji-Seung;Lim, Seong-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.3
    • /
    • pp.87-94
    • /
    • 2013
  • The main purpose of the distribution automation system (DAS) is to achieve efficient operation of primary distribution systems by monitoring and control of the feeder remote terminal unit(FRTU) deployed on the distribution feeders. DAS simulators are introduced to verify the functions of the application software installed in the central control unit(CCU) of the DAS. Because each DAS is developed on the basis of its own specific data model, the power system data cannot be easily transferred from the DAS to the simulator or vice versa. This paper presents a common information model(CIM)-based DAS simulator to achieve interoperability between the simulator and the DASs developed by different vendors. The CIM-based data model conversion between Smart DMS (SDMS) and Total DAS (TDAS) has been performed to establish feasibility of the proposed scheme.