• Title/Summary/Keyword: 임상결과

Search Result 9,964, Processing Time 0.05 seconds

20 Years Surgical Experiences for Ebstein's Anomaly (엡스타인 기형의 20년 수술 치험)

  • Lee, Sak;Park, Han-Ki;Lee, Chang-Young;Chang, Byung-Chul;Park, Young-Hwan
    • Journal of Chest Surgery
    • /
    • v.40 no.4 s.273
    • /
    • pp.280-287
    • /
    • 2007
  • Background: We retrospectively evaluated the clinical results of surgically managing patients with Ebstein's anomaly. Material and Method: Between Feb. f 984 and June 2006, 50 patients who underwent surgical treatment for Ebstein's anomaly at Yonsei Cardiovascular Center were retrospectively reviewed. The mean age of the patients was 26.9 years and 19 patients were male, Associated anomalies included atrial septal defect (33), patent ductus arteriosus (2), ventricular septal defect (1), and pulmonary stenosis (4), and 90%, (45/50) of the patients had more than a moderate degree of tricuspid regurgitation. Carpentier type A was present in 6 patients, type B in 26, type C in 14 and type D in 4. Ten patients were associated with WPW syndrome. Conservative surgery was possible in 31 patients (tricuspid annuloplasty, plication of the atrialized RV), Fontan's operation was peformed in 4 patients, tricuspid valve replacement was done in 12 and palliative surgery was done in 2 patients. Thirteen patients were associated with hi-directional cavopulmonary shunt (BCPS: one and a half ventricular repairs): 10 patients with WPW syndrome and 4 patients with atrial fibrillation underwent concomitant ablation. Result: The postoperative median NYHA functional class $(3{\rightarrow}1)$ and the mean cardio-thoracic ratio $(0.65{\rightarrow}0.59)$ were decreased significantly (p<0.001, p=0.014). The mean oxygen saturation $(86.6{\rightarrow}94.1%)$, and median TR grade $(4{\rightarrow}1)$ were also significantly improved (p=0.004, p<0.001). For comparison of BCPS and conservative surgery, the preoperative right ventricular pressure (33.0 vs. 41.3 mmHg), the ICU stay (2.80 vs. 1.89 days), the hospital say (10.6 vs. 16.8 days), and the left ventricular ejection fraction (64.3 vs. 72.8%) were statistically different. Postoperative mortality occurred in 3 patients (6%) due to biventricular failure in 2 patients and sepsis in the other patient. The mean follow up duration was 101.5 months, and one patient died of Fontan failure and 6 patients required reoperation (bioprosthetic degenerative change (2) and Fontan conversion (4)). The overall survival rate at 10 years was 90.2%, the freedom from reoperation rate and rate of cardiac related events were 78.9% and 49.2%, respectively. Conclusion: Surgical management of Ebstein's anomaly can be performed safely, and the associated BCPS may be helpful for high-risk patients. Adequate application of surgical management may increase the long-term survival with a reduced rate of reoperation.

Computed Tomography-guided Localization with a Hook-wire Followed by Video-assisted Thoracic Surgery for Small Intrapulmonary and Ground Glass Opacity Lesions (폐실질 내에 위치한 소결질 및 간유리 병변에서 흉부컴퓨터단층촬영 유도하에 Hook Wire를 이용한 위치 선정 후 시행한 흉강경 폐절제술의 유용성)

  • Kang, Pil-Je;Kim, Yong-Hee;Park, Seung-Il;Kim, Dong-Kwan;Song, Jae-Woo;Do, Kyoung-Hyun
    • Journal of Chest Surgery
    • /
    • v.42 no.5
    • /
    • pp.624-629
    • /
    • 2009
  • Background: Making the histologic diagnosis of small pulmonary nodules and ground glass opacity (GGO) lesions is difficult. CT-guided percutaneous needle biopsies often fail to provide enough specimen for making the diagnosis. Video-assisted thoracoscopic surgery (VATS) can be inefficient for treating non-palpable lesions. Preoperative localization of small intrapulmonary lesions provides a more obvious target to facilitate performing intraoperative. resection. We evaluated the efficacy of CT-guided localization with using a hook wire and this was followed by VATS for making the histologic diagnosis of small intrapulmonary nodules and GGO lesions. Material and Method: Eighteen patients (13 males) were included in this study from August 2005 to March 2008. 18 intrapulmonary lesions underwent preoperative localization by using a CT-guided a hook wire system prior to performing VATS resection for intrapulmonary lesions and GGO lesions. The clinical data such as the accuracy of localization, the rate of conversion-to-thoracotomy, the operation time, the postoperative complications and the histology of the pulmonary lesion were retrospectively collected. Result: Eighteen VATS resections were performed in 18 patients. Preoperative CT-guided localization with a hook-wire was successful in all the patients. Dislodgement of a hook wire was observed in one case. There was no conversion to thoracotomy, The median diameter of lesions was 8 mm (range: $3{\sim}15\;mm$). The median depth of the lesions from the pleural surfaces was 5.5 mm (range: $1{\sim}30\;mm$). The median interval between preoperative CT-guided with a hook-wire and VATS was 34.5 min (range: ($10{\sim}226$ min). The median operative time was 43.5.min (range: $26{\sim}83$ min). In two patients, clinically insignificant pneumothorax developed after CT-guided localization with a hook-wire and there were no other complications. Histological examinations confirmed 8 primary lung cancers, 3 cases of metastases, 3 cases of inflammation, 2 intrapulmonary lymph nodes and 2 other benign lesions. Conclusion: CT-guided localization with a hook-wire followed by VATS for treating small intrapulmonary nodules and GGO lesions provided a low conversion thoracotomy rate, a short operation time and few localization-related or postoperative complications. This procedure was efficient to confirm intrapulmonary lesions and GGO lesions.

Granulocytic Sarcoma(Chloroma) in Leukemic Patients (백혈병 환자의 과립구 육종(녹색종양))

  • Rhee, Seung-Koo;Kang, Yong-Ku;Bahk, Won-Jong;Jung, Yang-Kuk;Lee, Sang-Wook;Jeong, Ji-Ho
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.11 no.1
    • /
    • pp.54-61
    • /
    • 2005
  • Purpose: The granulocytic sarcoma which developed in leukemic patients are quite rare and it will have bad prognosis, but it's tumor pathogenesis and also their treatment are not yet established. Through this study we have tried to know their clinical course, prognosis and their end result of recent treatment. Material and Methods: Total 20 patients of granulocytic sarcoma which were developed in total 2,197 leukemic patients from April, 1998 to September, 2004 were treated at the leukemic center and the orthopaedic department of St. Mary's hospital, Catholic University of Korea, and followed them for 1~78 months(average 18 months). Results: Total 20 cases of granulocytic sarcoma was found in 14 cases of total 1,331 acute myelocytic leukemic patients(AML), 4 cases of total 744 of chronic myelocytic leukemic patients(CML), and only one case in total 122 of acute biphenotype of leukemia. And so their occurrence rate in leukmic patients are actually 0.91%, total 20 cases of granulocytic sarcoma in total 2,197 leukemic patients at same period. Their ages are average 28.3 years(4~52 years), and male are predominant(13 cases) than female(7 cases). Single involvement was found in 11 cases but multiple lesions are in 9 cases, and spine, brain, extremities, chest, and pelvic bone are involved in frequency. The granulocytic sarcoma was developed in various stages of the leukemia, ie, 8 cases in complete remission of leukemia, and 12 cases in the treatment process of AML. The pathohistologic evaluation of granulocytic sarcoma was done in 6 cases which was developed in their extremities, and confirmed numerous immature myeloblasts and lymphocytes mixed. The treatment of these granulocytic sarcoma was mainly limited for the treatment of leukemia by Glivac and massive steroid therapy(19cases) and also combined with the bone marrow transplantation(13 cases), but radiation therapy with average 3,500 rads in 15 cases out of total 20 sarcomas was also done, and followed them for average 17.5 months after development of granulocytic sarcomas. Finally their prognosis was so bad that 12 patients(60%) out of total 20 granulocytic sarcoma were dead in 6.5 months after sarcoma developed and we found the granulocytic sarcoma was more fatal if they are developed during the process of CML(mortality: 100%(4/4cases). Conclusion: The prognosis of granulocytic sarcomas in leukemic patients are quite fatal, and much more studies for their pathogenesis and ways of treatment should be performed continuously.

  • PDF

Radioprotective Effects of Granulocyte-Colony Stimulating Factor in the Jejunal Mucosa of Mouse (생쥐에서 과립구 집락형성인자(Granulocyte-Colony Stimulating Factor)의 공장점막에 대한 방사선 보호효과)

  • Ryu, Mi-Ryeong;Chung, Su-Mi;Kay, Chul-Seung;Kim, Yeon-Shil;Yoon, Sei-Chul
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.45-52
    • /
    • 2001
  • Purpose : Granulocyle-colony stimulating factor (G-CSF) has been widely used to treat neutropenia caused by chemotherapy or radiotherapy. The efficacy of recombinant human hematopoietic growth factors in improving oral mucositis after chemotherapy or radiotherapy has been recently demonstrated in some clinical studies. This study was designed to determine whether G-CSF can modify the radiation injury of the intestinal mucosa in mice. Materials and Methods : One hundred and five BALB/c mice weighing 20 grams were divided into nine subgroups including G-CSF alone group $(I:10\;{\mu}g/kg\;or\;II:100\;{\mu}g/kg)$, radiation alone group (7.5 or 12 Gy on the whole body), combination group with G-CSF and radiation (G-CSF I or II plus 7.5 Gy, G-CSF I or II plus 12 Gy), and control group. Radiation was administered with a 6 MV linear accelerator (Mevatron Siemens) with a dose rate of 3 Gy/min on day 0. G-CSF was injected subcutaneously for 3 days, once a day, from day -2 to day 0. Each group was sacrificed on the day 1, day 3, and day 7. The mucosal changes of jejunum were evaluated microscopically by crypt count per circumference, villi length, and histologic damage grading. Results : In both G-CSF I and II groups, crypt counts, villi length, and histologic damage scores were not significantly different from those of the control one (p>0.05). The 7.5 Gy and 12 Gy radiation alone groups showed significantly lower crypt counts and higher histologic damage scores compared with those of control one (p<0.05). The groups exposed to 7.5 Gy radiation plus G-CSF I or II showed significantly higher crypt counts and lower histologic damage scores on the day 3, and lower histologic damage scores on the day 7 compared with those of the 7.5 Gy radiation alone one (p<0.05). The 12 Gy radiation plus G-CSF I or II group did not show significant difference in crypt counts and histologic damage scores compared with those of the 12 Gy radiation alone one (p>0,05). Most of the mice in 12 Gy radiation with or without G-CSF group showed intestinal death within 5 days. Conclusion : These results suggest that G-CSF may protect the jejunal mucosa from the acute radiation damage following within the tolerable ranges of whole body irradiation in mice.

  • PDF

Analysis of Neurological Complications on Antegrade Versus Retrograde Cerebral Perfusion in the Surgical Treatment of Aortic Dissection (대동맥 박리에서 전방성 뇌 관류와 역행성 뇌 관류의 신경학적 분석)

  • Park Il;Kim Kyu Tae;Lee Jong Tae;Chang Bong Hyun;Lee Eung Bae;Cho Joon Yong
    • Journal of Chest Surgery
    • /
    • v.38 no.7 s.252
    • /
    • pp.489-495
    • /
    • 2005
  • In the surgical treatment of aortic dissection, aortic arch replacement under total circulatory arrest is often performed after careful inspection to determine the severity of disease progression. Under circulatory arrest, antegrade or retrograde cerebral perfusion is required for brain protection. Recently, antegrade cerebral perfusion has been used more, because of the limitation of retrograde cerebral perfusion. This study is to compare these two methods especially in the respect to neurological complications. Material and Method: Forty patients with aortic dissection involving aortic arch from May 2000 to May 2004 were enrolled in this study, and the methods of operation, clinical recovery, and neurological complications were retrospectively reviewed. Result: In the ACP (antegrade cerebral perfusion) group, axillary artery cannulation was performed in 10 out of 15 cases. In the RCP (retrograde cerebral perfusion) group, femoral artery Cannulation was performed in 24 out of 25 cases. The average esophageal and rectal temperature under total circulatory arrest was $17.2^{\circ}C\;and\;22.8^{\circ}C$ in the group A, and $16.0^{\circ}C\;and\;19.7^{\circ}C$ in the group B, respectively. Higher temperature in the ACP group may have brought the shorter operation and cardiopulmonary bypass time. However, the length of period for postoperative clinical recovery and admission duration did not show any statistically significant differences. Eleven out of the total 15 cases in the ACP group and thirteen out of the total 25 cases in the RCP group showed neurological complication but did not show statistically significant difference. In each group, there were 5 cases with permanent neurological complications. All 5 cases in the ACP group showed some improvements that enabled routine exercise. However all 5 cases in RCP group did not show significant improvements. Conclusion: The Antegrade, cerebral perfusion, which maintains orthordromic circulation, brings moderate degree of hypothermia and, therefore, shortens the operation time and cardiopulmonary bypass time. We concluded that Antegrade cerebral perfusion is safe and can be used widely under total circulatory arrest.

The Clinical Significance of Follow Up SCC Levels in Patients with Recurrent Squamous Cell Carcinoma of the Cervix (재발성 자궁경부 편평상피암 환자들에서 Squamous Cell Carcinoma 항원의 유용성)

  • Choi Young Min;Park Sung Kwang;Cho Heung Lae;Lee Kyoung Bok;Kim Ki Tae;Kim Juree;Sohn Seung Chang
    • Radiation Oncology Journal
    • /
    • v.20 no.4
    • /
    • pp.353-358
    • /
    • 2002
  • Purpose : To investigate the clinical usefulness of a follow-up examination using serum squamous cell carcinoma antigen (SCC) for the early detection of recurrence in patients treated for conical squamous cell carcinoma. Materials and Methods : 20 patients who were treated for recurrent cervical squamous cell carcinoma between 1997 and 1998, who had experienced a complete remission after radiotherapy and who underwent an SCC test around the time when recurrence was detected, were included in this study. The levels of SCC were measured from the serum of the patients by immunoassay and values less than 2 ng/mL were regarded as normal. The sensitivity of the SCC test for use in the detection of recurrence, the association between the SCC values and the recurrence patterns and the tumor size and stage, and the temporal relation between the SCC increment and recurrence detection were evaluated. Results : The SCC values were above normal in 17 out of 20 patients, so the sensitivity of the SCC test for the detection of recurrence was $85\%$, and the mean and median of the SCC values were 15.2 and 9.5 ng/mL, respectively. No differences were observed in the SCC values according to the recurrence sites. For 11 patients, the SCC values were measured over a period of 6 months before recurrence was detected, and the mean and median values were 13.6 and 3.6 ng/mL, respectively. The SCC values of 7 patients were higher than the normal range, and the SCC values of the other 4 patients were normal but 3 among them were above 1.5 ng/mL. At the time of diagnosis, the SCC valuess were measured for 16 of the 20 recurrent patients, and the SCC values of the patients with a bulky tumor $(\geq4\;cm)$ or who were in stage IIb or III were higher than those of the patients with a non-bulky tumor or who were in stage Ib or IIa. Conclusion : The SCC test is thought to be useful for the early detection of recurrence during the follow up period in patients treated for cervical squamous cell carcinoma. When an effective salvage treatment is developed in the future, the benefit of this follow-up SCC test will be increased.

Comparison of Virtual Wedge versus Physical Wedge Affecting on Dose Distribution of Treated Breast and Adjacent Normal Tissue for Tangential Breast Irradiation (유방암의 방사선치료에서 Virtual Wedge와 Physical Wedge사용에 따른 유방선량 및 주변조직선량의 차이)

  • Kim Yeon-Sil;Kim Sung-Whan;Yoon Sel-Chul;Lee Jung-Seok;Son Seok-Hyun;Choi Ihl-Bong
    • Radiation Oncology Journal
    • /
    • v.22 no.3
    • /
    • pp.225-233
    • /
    • 2004
  • Purpose: The Ideal breast irradiation method should provide an optimal dose distribution In the treated breast volume and a minimum scatter dose to the nearby normal tissue. Physical wedges have been used to Improve the dose distribution In the treated breast, but unfortunately Introduce an Increased scatter dose outside the treatment yield, pavllculariy to the contralateral breast. The typical physical wedge (FW) was compared with 4he virtual wedge (VW) to do)ermine the difference In the dose distribution affecting on the treated breast and the contralateral breast, lung, heart and surrounding perlpheral soft tissue. Methods and Materials: The data collected consisted of a measurement taken with solid water, a Humanoid Alderson Rando phantom and patients. The radiation doses at the ipsllateral breast and skin, contralateral breast and skin, surrounding peripheral soft tissue, and Ipsllateral lung and heart were compared using the physical wedge and virtual wedge and the radiation dose distribution and DVH of the treated breast were compared. The beam-on time of each treatment technique was also compared Furthermore, the doses at treated breast skin, contralateral breast skin and skin 1.5 cm away from 4he field margin were also measured using TLD in 7 patients of tangential breast Irradiation and compared the results with phantom measurements. Results: The virtual wedge showed a decreased peripheral dose than those of a typical physical wedge at 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$, and 60$^{\circ}$. According to the TLD measurements with 15$^{\circ}$ and 30$^{\circ}$ virtual wedge, the Irradiation dose decreased by 1.35$\%$ and 2.55$\%$ In the contralateral breast and by 0.87$\%$ and 1.9$\%$ In the skin of the contralateral breast respectively. Furthermore, the Irradiation dose decreased by 2.7$\%$ and 6.0$\%$ in the Ipsllateral lung and by 0.96$\%$ and 2.5$\%$ in the heart. The VW fields had lower peripheral doses than those of the PW fields by 1.8$\%$ and 2.33$\%$. However the skin dose Increased by 2.4$\%$ and 4.58$\%$ In the Ipsliateral breast. VW fields, In general, use less monitor units than PW fields and shoriened beam-on time about half of PW. The DVH analysis showed that each delivery technique results In comparable dose distribution in treated breast. Conclusion: A modest dose reduction to the surrounding normal tissue and uniform target homogeneity were observed using the VW technique compare to the PW beam in tangential breast Irradiation The VW field is dosmetrically superlor to the PW beam and can be an efficient method for minimizing acute, late radiation morbidity and reduce 4he linear accelerator loading bV decreasing the radiation delivery time.

Myocardial Tracer Uptake in SPECT Images after Direct Intracoronary Injection Of TI-201: Comparison with Stress-Reinjection Images (관동맥내 주사 TI-201 SPECT에서 심근 분절의 섭취: 부하-재주사 TI-201 영상과의 비교)

  • Seo, Ji-Hyoung;Kang, Seong-Min;Bae, Jin-Ho;Lee, Yong-Jin;Lee, Sang-Woo;Yoo, Jeong-Soo;Ahn, Byeong-Cheol;Cho, Yong-Geun;Lee, Jae-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.291-298
    • /
    • 2007
  • Purpose: To investigate the feasibility of TI-201 SPECT with intra coronary injection (lC-I) in the detection of viable myocardium, we have performed SPECT imaging after direct intracoronary injection of TI-201 and images were compared with those of stress-reinjection (Re-I) SPECT. Methods: Fourteen coronary artery disease patients (male 11, mean age 54 years) who had myocardial infarction or demonstrated left ventricular wall motion abnormality on echocardiography were enrolled. Three mCi of TI-201 was injected into both coronary arteries during angiography and images were acquired between 6- and 24-hour after injection. Reinjection imaging with 1 mCi of TI-201 was performed at 4-hour after adenosine stress imaging with 3 mCi of TI-201. Images were interpreted according to 4-grade visual scoring system (grade 0-3). Segments with mild to moderated uptake (${\leq}$grade 1), and upgraded more than one score with reinjection, and were defined as viable myocardium. Results: Image quality was poor in two cases with IC-I. Numbers of non-viable segments were 60 (23.8%) with IC-I, and 38 (15.1%) with Re-I, respectively. Overall agreement for perfusion grade per myocardial segment in each IC-I and Re-I was 76.5%. Overall agreement for viable segment between IC-I and Re-I was 90.5%. Only one out of 38 segments interpreted as non-viable with Re-I were interpretated as viable with IC-I. And 23 out of 214 segments interpreted as viable with Re-I were interpreted as non-viable with IC-I. Conclusion: Intracoronary TI-201 SPECT seemed to be not advantageous over stress-rest reinjection imaging in the assessment of myocardial viability, mainly due to low count statistics at 6-hour or 24-hour delayed time points. The feasibility of intracoronary TI- 201 SPECT is considered to be limited.

The Correction Factor of Sensitivity in Gamma Camera - Based on Whole Body Bone Scan Image - (감마카메라의 Sensitivity 보정 Factor에 관한 연구 - 전신 뼈 영상을 중심으로 -)

  • Jung, Eun-Mi;Jung, Woo-Young;Ryu, Jae-Kwang;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.208-213
    • /
    • 2008
  • Purpose: Generally a whole body bone scan has been known as one of the most frequently executed exams in the nuclear medicine fields. Asan medical center, usually use various gamma camera systems - manufactured by PHILIPS (PRECEDENCE, BRIGHTVIEW), SIEMENS (ECAM, ECAM signature, ECAM plus, SYMBIA T2), GE (INFINIA) - to execute whole body scan. But, as we know, each camera's sensitivity is not same so it is hard to consistent diagnosis of patients. So our purpose is when we execute whole body bone scans, we exclude uncontrollable factors and try to correct controllable factors such as inherent sensitivity of gamma camera. In this study, we're going to measure each gamma camera's sensitivity and study about reasonable correction factors of whole body bone scan to follow up patient's condition using different gamma cameras. Materials and Methods: We used the $^{99m}Tc$ flood phantom, it recommend by IAEA recommendation based on general counts rate of a whole body scan and measured counts rates by the use of various gamma cameras - PRECEDENCE, BRIGHTVIEW, ECAM, ECAM signature, ECAM plus, IFINIA - in Asan medical center nuclear medicine department. For measuring sensitivity, all gamma camera equipped LEHR collimator (Low Energy High Resolution multi parallel Collimator) and the $^{99m}Tc$ gamma spectrum was adjusted around 15% window level, the photo peak was set to 140-kev and acquirded for 60 sec and 120 sec in all gamma cameras. In order to verify whether can apply calculated correction factors to whole body bone scan or not, we actually conducted the whole body bone scan to 27 patients and we compared it analyzed that results. Results: After experimenting using $^{99m}Tc$ flood phantom, sensitivity of ECAM plus was highest and other sensitivity order of all gamma camera is ECAM signature, SYMBIA T2, ECAM, BRIGHTVIEW, IFINIA, PRECEDENCE. And yield sensitivity correction factor show each gamma camera's relative sensitivity ratio by yielded based on ECAM's sensitivity. (ECAM plus 1.07, ECAM signature 1.05, SYMBIA T2 1.03, ECAM 1.00, BRIGHTVIEW 0.90, INFINIA 0.83, PRECEDENCE 0.72) When analyzing the correction factor yielded by $^{99m}Tc$ experiment and another correction factor yielded by whole body bone scan, it shows statistically insignificant value (p<0.05) in whole body bone scan diagnosis. Conclusion: In diagnosing the bone metastasis of patients undergoing cancer, whole body bone scan has been conducted as follow up tests due to its good points (high sensitivity, non invasive, easily conducted). But as a follow up study, it's hard to perform whole body bone scan continuously using same gamma camera. If we use same gamma camera to patients, we have to consider effectiveness of equipment's change by time elapsed. So we expect that applying sensitivity correction factor to patients who tested whole body bone scan regularly will add consistence in diagnosis of patients.

  • PDF

A Comparative Study of the Standard Uptake Values of the PET Reconstruction Methods; Using Contrast Enhanced CT and Non Contrast Enhanced CT (PET/CT 영상에서 조영제를 사용하지 않은 CT와 조영제를 사용한 CT를 이용한 감쇠보정에 따른 표준화섭취계수의 비교)

  • Lee, Seung-Jae;Park, Hoon-Hee;Ahn, Sha-Ron;Oh, Shin-Hyun;NamKoong, Heuk;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.235-240
    • /
    • 2008
  • Purpose: At the beginning of PET/CT, Computed Tomography was mainly used only for Attenuation Correction (AC), but as the performance of the CT have been increase, it could give improved diagnostic information with Contrast Media. But it was controversial that Contrast Media could affect AC on PET/CT scan. Some submitted thesis' show that Contrast Media could overestimate when it is for AC data processing. On the contrary, the opinion that Contrast Media could be possible to affect the alteration of SUV because of the overestimated AC. But it does not have a definite effect on the diagnosis. Thus, the affection of Contrast Media on AC was investigated in this study. Materials and Methods: Patient inclusion criteria required a history of a malignancy and performance of an integrated PET/CT scan and contrast- enhanced CT scan within a 1-day period. Thirty oncologic patients who had PET/CT scan from December 2007 to June 2008 underwent staging evaluation and met these criteria. All patients fasted for at least 6 hr before the IV injection of approximately 5.6 MBq/kg (0.15 mCi/kg) of $^{18}F$-FDG and were scanned about 60 min after injection. All patients had a whole body PET/CT performed without IV contrast media followed by a contrast-enhanced CT on the Discovery STe PET/CT scanner. CT data were used for AC and PET images came out after AC. The ROIs drew and measured SUV. A paired t-test of these results was performed to assess the significance of the difference between the SUV obtained from the two attenuation corrected PET images. Results: The mean and maximum Standardized Uptake Values (SUV) for different regions averaged over all Patients. Comparing before using Contrast Media and after using, Most of ROIs have the increased SUV when it did Contrast Enhanced CT compare to Non-Contrast enhanced CT. All regions have increased SUV and also their p value was under 0.05 except the mean SUV of the Heart region. Conclusion: In this regard, the effect on SUV measurements that occurs when a contrast-enhanced CT is used for attenuation correction could have significant clinical ramifications. But some submitted thesis insisted that the percentage change in SUV that can determine or modify clinical management of oncology patients is small. Because there was not much difference that could be discovered by interpreter. But obviously the numerical change was occurred and on the stage finding primary region, small change would be base line, such as the region of liver which has greater change than the other regions needs more attention.

  • PDF