Numerical Study of Natural Convection in a Square Enclosure with an Inner Circular Cylinder for Rayleigh Number of 107 (107의 Rayleigh 수에서 원형 실린더가 존재하는 사각형 실린더 내부의 자연대류에 관한 수치적 연구)

  • Yu, Dong-Hun;Yoon, Hyun-Sik;Ha, Man-Yeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.8
    • /
    • pp.739-747
    • /
    • 2010
  • Numerical calculations are carried out for evaluating the natural convection induced by the temperature difference between a hot inner circular cylinder and a cold outer square enclosure. A two-dimensional solution for unsteady natural convection is obtained by using the finite volume method to model an inner circular cylinder that was designed by using the immersed boundary method (IBM) for a Rayleigh number of $10^7$. In this study, we investigate the effect of the location ($\delta$) of the inner cylinder, which is located along the vertical central axis of the outer enclosure, on the heat transfer and fluid flow. The natural convection changes from unsteady to steady state depending on the $\delta$. The two critical lower bound and upper bound positions are ${\delta}_{C,L}$ = 0.05 and ${\delta}_{C,U}$ = 0.18, respectively. Within these defined bounds, the thermal and flow fields are in steady state.

A Study on the Effects on Low Cycle Fatigue Life of a High Pressure Turbine Nozzle due to the Perturbation of Crystal Orientation of Grain of DS Materials (일방향 응고 재료의 결정립 성장 방향 섭동이 고압터빈 노즐 저주기 피로 수명에 미치는 영향에 대한 연구)

  • Huh, Jae Sung;Kang, Young Seok;Rhee, Dong Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.7
    • /
    • pp.653-658
    • /
    • 2016
  • High pressure components of a gas turbine engine are generally made of nickel-base superalloys, using precision casting process due to complicated geometries with intricate channels and cooling holes. Turbine components manufactured from directionally solidified and single crystal materials have columnar grains; however, it is found that the crystals do not grow in its preferred direction, although the orientation can be controlled. This anisotropy can lead to the variations of elastic and Hill's parameters in constitutive equations, and they alter stress distributions and the low cycle fatigue life. We aims to evaluate the effects of perturbed crystal orientations on the structural integrity of a directionally solidified nozzle using low cycle fatigue life. We also attempt to show the necessity for the control of allowed manufacturing errors and stochastic analysis. Our approaches included conjugate heat transfer and structural analysis, along with low cycle fatigue life assessment.

A Study on Corrosive Wear Characteristics and the Mechanism of Austempered Low-Alloy Ductile Iron (오스템퍼링 한 저합금구상흑연주철의 부식마멸특성 및 그 기구에 관한 연구)

  • 박흥식;진동규
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.6
    • /
    • pp.1404-1411
    • /
    • 1993
  • This study was undertaken to investigate the corrosive wear charateristics upon various transformation condition of austempered low-alloy ductile cast iron in corrosive environments against mating specimen made of the hardened SM45C. The corrosive wear test was carried out by rubbing the annular surface of two test pieces in distilled water and aqueous solution at constant sliding speed of 0.5m/s. In severe wear region, the corrosive wear rate Wc increased hastily with NaCl concentration owing to intermetallic adhesion but Wc went down slowly in mild wear region due to lubricating effect of the corrosion product. The critical sliding distance decreased with increasing NaCl concentration due to increased generation rate of the corrosion product and the specific corrosive wear rate has maximum in 1% NaCl aqueous solution at mild wear region. With the variation of matrix, the corrosive wear resistance of the fine acicular bainite was higher than that of coarse upper bainite because of reducing the local cell reaction by carbides. A growth in volume fraction of retained austenite in matrix increased the Wc due to soften surface, but has a declining tendency of Wc in mild wear region.

Three-Dimensional Natural Convection from a Single Module on the Wall of a Vertical Parallel-Plate Channel (수직평행채널의 벽면에 부착된 단일모듈로부터의 3차원 자연대류 열전달)

  • Riu, K.J.;Lee, J.H.;Kim, H.W.
    • Solar Energy
    • /
    • v.19 no.3
    • /
    • pp.29-41
    • /
    • 1999
  • Three-dimensional natural convective heat transfer in a vertical channel with a protruding single module was investigated experimentally. The particular interest was in the removal of thermal energy from the module by convective heat transfer. Hence radiative and conductive heat losses were estimated by using thermocouples and heat flux sensor respectively. The flow fields in the channel were visualized by means of a smoke-method. Also, local temperatures were measured by thermocouples inside the channel, along the vertical wall and module surface. It is found that convective heat transfer was promoted at the lower comer of the module and was decreased at the upper comer due to a recirculation zone. A general correlation of the critical channel ratios was found as a function of Rayleigh number. For the range of $8.28{\times}10^3<Ra^*_c<3.48{\times}10^6$, a useful correlation for the mean Nusselt number was proposed as a function of modified channel Rayleigh number.

  • PDF

Study on the Solubilization of Phenoxide Anion into Aqueous Micellar Systems of Cationic Surfactants (양이온 계면활성제에 의한 Phenoxide 음이온의 가용화에 대한 연구)

  • Lee, Byung Hwan
    • Journal of the Korean Chemical Society
    • /
    • v.42 no.4
    • /
    • pp.383-390
    • /
    • 1998
  • The interaction of phenoxide anion with several cationic surfactant micelles (DTAB, TTAB, CTAB, CDEAB, and CTAC) was studied by UV/Vis spectrophotometric method. The solubilization constants of phenoxide anion into the cationic micellar phase and the critical micelle concentration of these surfactants in the presence of the phenoxide anion could be determined from the absorbance changes. The measured solubilization constants were changed according to the following order: $K_s(CTAC)>K_s(CDEAB)>K_s(CTAB)>K_s(TTAB)>K_s(DTAB).$ Effects of salts(NaCl and NaBr) and n-alcohols(butanol, pentanol, and hexanol) on the solubilization of phenoxide anion by the TTAB system have been also measured and analyzed. There was a great decrease of solubilization constant and CMC with these additives. The standard Gibbs free energy, enthalpy, and entropy changes for the solubilization of phenoxide anion by the TTAB system were calculated from the temperature dependence of $K_s$ values.

  • PDF

Effect of In Vitro Degradation on the Weight Loss and Tensile Strength of PLA/PEG Melt Blend Fiber (In Vitro 분해가 PLA/PEG 용융블렌드 섬유의 무게감량률 및 인장강도에 미치는 영향)

  • Yoon, Cheol-Soo;Ji, Dong-Sun
    • Polymer(Korea)
    • /
    • v.33 no.6
    • /
    • pp.581-587
    • /
    • 2009
  • PLA/PEG blend fibers composed of poly (lactic acid) (PLA) and poly (ethylene glycol) (PEG) were prepared via melt blending and spinning for bioabsorbable filament sutures. The blend fibers hydrolyzed with the immersion in a phosphate buffer solution at pH 7.4 and $37\;^{\circ}C$ for 1~8 weeks. The effects of blending time, blend composition, and hydrolysis time on the weight loss and tensile strength of the hydrolyzed blend fibers were investigated. After hydrolysis, the weight loss of the blend fibers increased with increasing PEG content, blending time, and hydrolysis time. The tensile strength and tensile modulus of the blend fibers decreased with increasing PEG content, blending time, and hydrolysis time. Therefore, it can be concluded that the weight loss of the PLA/PEG blend fibers was less than 0.9% even at hydrolysis time of 2 weeks and their strength retentions were over 90%.

A Study on the Method for Releasing the Internal Pressure of the Propane Cylinder caused by Liquid Expansion (액팽창을 고려한 프로판용기의 내압 해소방안에 대한 연구)

  • Yim, Sang-Sik;Jang, Kap-Man;Lee, Jin-Han;Park, Gi-Dong;Kim, Ki-Bum
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.5
    • /
    • pp.98-103
    • /
    • 2015
  • Liquefied petroleum gas can be charged up to 85% of cylinder volume by enforcement regulations of safety control and business of liquefied petroleum gas act. The charged mass by enforcement regulations is considered by liquid expansion of internal liquefied petroleum gas at $65^{\circ}C$. But the temperature of liquid would not be suspended under $65^{\circ}C$ in a cylinder or portable vessel at certain situation. In the thermodynamics view point, the cylinder can be exposed to high pressure by liquid expansion. Consequently, it can be possible to potential risk such as physical explosion. Hence, this paper will offer a method of estimated internal pressure by liquid expansion at critical state in the closed system. Also, the structural factor which is given rise to volume increasement of cylinder is offered by experiment. This paper is expected as crucial reference for a cylinder design of liquefied petroleum gas.

Heat Transfer Characteristics of Supercritical $CO_2$ in Helical Coil Gas Coolers on the Change of Coil Diameters (코일직경변화에 따른 헬리컬 코일형 가스냉각기내 초임계 이산화탄소의 냉각열전달 특성)

  • Son, Chang-Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.3
    • /
    • pp.44-48
    • /
    • 2007
  • The cooling heat transfer characteristics of supercritical $CO_2$ in a helical coil gas cooler on the change of coil diameters are experimentally investigated. The main components of the refrigerant loop are a receiver, a variable speed pump, a mass flow-meter, a pre-heater and a helical coil gas cooler (test section). The test sections are made of a copper tube which the inner diameter is 4.55 mm and the helical coil diameters are done of 26.75 mm and 41.35 mm. The mass fluxes of refrigerant are varied from 200 to 800 [$kg/m^2s$] and the inlet pressures of gas cooler are 7.5 to 10.0 (MPa). A gas cooler with helical coil diameter of 26.75 mm has larger heat transfer coefficient than that of 41.35 mm. Also, when compared with experimental data and published correlations avaliable, most of correlations are under-predicted, but Pitla published correlations avaliable, most of correlations are under-predicted, but Pitla et al.'s correlation shows a relatively good coincidence with the experimental data except the region of pseudo critical temperature.

  • PDF

Heat Transfer Characteristics of Carbon Dioxide in a Inclined Helical Coil Type Heat Exchanger with Inner Diameter Tube of 4.55 mm (내경 4.55 mm의 경사진 헬리컬 코일형 열교환기내 이산화탄소의 열전달 특성에 관한 연구)

  • Son, Chang-Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.3
    • /
    • pp.1-6
    • /
    • 2007
  • The heat transfer coefficient and pressure drop during gas cooling process of $CO_2$ (R-744) in inclined helical coil copper tubes were investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and a inclined helical coil type gas cooler (test section). The test section consists of a smooth copper tube, which is specified as the inner diameter of 4.55 mm. The refrigerant mass fluxes were varied from 200 to $600kg/m^2s$ and the inlet pressures of gas cooler were done 7.5 to 10.0 (MPa). The heat transfer coefficients of $CO_2$ in the inclined helical coil tubes increase with the increase of mass flux and gas cooling pressure of $CO_2$. The pressure drop of $CO_2$ in the gas cooler shows relatively good coincidence with those predicted by Ito's correlation developed for single-phase in a helical coil tube. The local heat transfer coefficient of $CO_2$ is well coincident with the correlation by Pitla et al. However, at the region near pseudo-critical temperature, the experiments indicate higher values than the Pitla et al. correlation.

  • PDF

Study on depositing oxide films on Ni substrate for superconducting tape (초전도 테이프 제작을 위한 니켈기판상의 산화물 박막증착에 대한 연구)

  • Kim, Ho-Sup;Shi, Dongqui;Chung, Jun-Ki;Ha, Hong-Soo;Ko, Rock-Kil;Choi, Soo-Jeong;Park, Yu-Mi;Song, Kyu-Jeong;Yeom, Do-Jun;Park, Chan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.531-534
    • /
    • 2004
  • 초전도 coated conductor는 보호층/초전도층/완충층/금속기판의 구조를 가지며 완충층은 다층산화물 박막으로 이루어져 있다. 본 연구에서는 니켈 기판의 원자가 초전도층으로 확산 침투하는 것을 방지하는 YSZ(Yttria Stabilized Zirconia) 박막의 증착방법 및 최적조건에 대하여 소개하고자 한다. 금속타겟을 사용하며 산화반응가스로서 수증기를 사용하는 것을 특징으로 하는 DC reactive sputtering을 이용하여 YSZ를 증착하였으며 기판 온도는 $850^{\circ}C$ 이며 증착시 수증기 분압은 1mTorr이었다. YSZ의 최적두께를 알아보기 위하여 $CeO_2(12.2nm)/Ni$ 상부에 130nm, 260nm, 390nm, 650nm로 두께를 달리하여 YSZ층을 증착하고 SEM으로 박막 표면상태를 관찰한 결과 columnar grain growth를 하며 두께가 두꺼워 질수록 표면조도가 증가함을 알 수 있었다. 4개의 각 시료위에 thermal evaporation 증착법을 이용하여 $CeO_2$를 18.3nm의 두께로 증착한 후 PLD를 이용하여 YBCO 초전도 박막을 300nm 두께로 증착하였고 77K, 0T에서 임계전류가 각각 0, 6A, 7.5A, 5A로 측정되었다. 이는 YSZ층의 두께가 두꺼워질수록 기판 구성원자의 확산방지역할을 충실히 하는 반면에 표면조도는 증가함을 알 수 있었다.

  • PDF