• Title/Summary/Keyword: 일본건축

Search Result 592, Processing Time 0.029 seconds

A Study on the comparison of Infill Technology between Korea long life Apartment Mock up House and Japan KSI experimental House (국내 장수명 공동주택 Mock-up House와 일본 KSI 실험주택 인필 요소기술 비교 연구)

  • Choi, Young Ho;Kim, Shin;Kim, Sung Wan
    • KIEAE Journal
    • /
    • v.8 no.4
    • /
    • pp.63-69
    • /
    • 2008
  • The thesis is a comparative analysis of Infill Technologies between Korea's long-life Mock-up House, a study driven by 'Durability and Flexibility of Long-life Housing Technology Development' of R&D, and Japan's KSI experimental house, the major example of Japan's long-llfe housing. In terms of the domestic Mock-up House, a system of building the floor first was applied. The floor material of each housing unit required a development of dry heating component that is partially substitutable in order to avoid conflict with the finishing. Also, a development of a floor system that can counteract against the construction inaccuracy was required. In the Case of an outer wall, need to make the wall with the chassis. In the case of ceiling, need to develop the double ceiling system which is good for sound insulation. Also, in comparison to KSI experimental house in Japan, it would require to develop a wiring system of the ceiling which can react to the movement of the wall. Especially, to assure the flexible nature of an internal wall, it would desperately require the research and development of the products related to components and flexible system of mechanical/electrical/communication parts as well as supporting institutionalized system for this development. Furthermore, for KSI experimental house in Japan, it would be necessary to formulate a construction manual as well as a systematic and practical planning guide to invent a new interface rule which will secure simplicity of assembling, dismantling, installation and replacement of architectural components for which research development is quite insignificant at the moment. This effort will have to continue to give a solid direction for better application of such reference manual during construction and development of long life span apartment by public sector as well as private corporations.

Selection on Representative Compound According to the Characteristics of the Change of VOC Concentration Indoor from the Newly Built House in Japan (일본 신축주택의 실내 VOC의 실태와 농도추이 특성에 의한 유형별 대표물질선정)

  • Yoo, Bok-Hee;Tanaka, Tatsuaki;Yoon, Chung-Sook
    • KIEAE Journal
    • /
    • v.1 no.1
    • /
    • pp.35-43
    • /
    • 2001
  • The VOC, which were detected from the newly built house, exist as a certain number of types according to the characteristics of the change of VOC concentration indoors. In this paper, we aim to divide the VOC into types so that those with similar characteristics of the transition of their concentration are in the same group and select the representative compound according to each classified type, and to verify these processes statistically in order to verify and propose new method creating the representing index of the VOC concentration in indoor which is used in evaluation of the degree of air pollution. As a result, the characteristic of the change of VOC concentration in the indoor can be divided into three types. Type1; the group in which the concentration is relatively high right after the completion of the house, and then decreases rapidly. Type2; the group in which the concentration is relatively low right after the completion of the house, and then although it shows the tendency of increasing and decreasing repeatedly, it decreases overall. Type3 is the group, which show only one peak at a certain time during the measuring period. As the method like this was verified to have the statistical significance, the Ethylbenzene was selected as the representative compound of type1, and Styrene was selected as that of type2. Moreover, if considering transition of the VOC from the point of similarity, the research method of making the classification and the selection of the representative compound in this study are said to be significant method.

  • PDF

A Study on the Mineral Water in Europe Partial Area (유럽 일부 지역의 광천수 수질특성에 관한 연구)

  • Hwang Sang-Yong
    • Journal of environmental and Sanitary engineering
    • /
    • v.19 no.4 s.54
    • /
    • pp.76-81
    • /
    • 2004
  • From September 1, 2003 to November 30, 2004, 20 mineral water wells were selected for some area in east Europe and the study on their water quality was analized. It revealed that mineral water contained considerable quantity of magnesium ions which helps the smooth activities of vascular muscles, nervous systems and protects skins from allergic reactions. It also lowers cholesterol level and contains high concentration of calcium ions which is one of the vital components of teeth and bone like phosphorus. Thus it is concluded that it is not qualified as boiler feed water as it has overall high degree of hardness by the presence of four times content of $Mg^{2+}\;and\;Ca^{2+}$.

A Study on the Main Characteristics and Factors of the Process of Beginning Egress during the Fire at the Buildings - Focus on Overseas Fire Cases including the Japanese - (건축물 화재 시 피난개시과정의 주요 특성 및 요소에 관한 연구 - 일본 등 해외 화재사례를 중심으로 -)

  • Park, Jae-Sung
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.59-68
    • /
    • 2012
  • Predicting occupants' behaviors from the start of the fire to egress and reducing the time required for such process are critical matters that can decide success and failure of safe egress. In this research, research literatures and theories and fire cases were compared and analyzed so as to prepare logical grounds that could predict the process of beginning egress. As a result of this research, there was a significant difference in the time elapsed until people start evacuating due to spatial positions and quarantine from the place from which the fire originated and their auditive and olfactory signs did not recognize the fire instantly and they showed a strong tendency to recognize the fire by visual sign, warning announcement for egress and notice by others. And the results also showed that only a very small minority of occupants evacuated as soon as they perceived the fire and that variation in the time elapsed until evacuation begun for occupants were wider as the size of building was bigger and that accommodations such as hotel had wider variation in the time elapsed regardless of the size of buildings.

Universal Design characteristics shown in the Japanese model houses (일본 주택의 유니버설디자인 특성에 관한 연구)

  • Lee, Yeunsook;Lee, Soyoung;Yeo, Wookhyun;Jang, Miseon;Lee, Sunmin;Lee, Yoojin
    • KIEAE Journal
    • /
    • v.7 no.1
    • /
    • pp.5-13
    • /
    • 2007
  • Since aging has become one of most hot and serious issues in the whole global world, universal design as a strategic concept to enable the elderly age in place has received much attention and its importance is getting recognized. Japan has undergone the Aging phenomenon much earlier than Korea and other countries. During that time, through much trials and errors, it accumulated the wisdoms and techniques to precede aging friendly environment and products. Therefore current Japan house is a comprehensive setting which embraces lots of universal design features that has a valuable implication for Korean development that faces fast aging future. The purpose of this study was to delineate characteristics of universal design features appeared in Japanese Model houses. One site of housing park in the city where various model houses of representative housing construction companies was selected as a cluster area for data collecting. Data were collected mainly through field survey at the housing park of Tokyo during November, 2006, and additional data were collected through website and company information of relevant company. Universal design features were extracted for 17 houses of the housing park and sorted and analyzed according to the analysis frame. The frame were made using 2 major clusters; space area, and 8 universal design principle. Results showed a range of universal design feature and its detail universal design principle satisfied. The 8 principle currently developed became to house realistic practical examples and theory became proved its impractical power. The academic, educational and industrial implication were documented.

Structural Tensile Capacities of Split-Tee Connection with High Strength Bolts (고력볼트 Split Tee 접합부의 인장내력)

  • Choi, Hye Kyoung;Choi, Sung Mo;Kim, Jin Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.5 s.66
    • /
    • pp.541-549
    • /
    • 2003
  • Split-tee connection with High Strength Bolts is normally used in low and middle rise buildings in Europe because the structural efficiency and installation work of connections are excellent. However, the domestic situation is different from that in Europe. The analysis and the design for the T-split connection are complicated, because the structural behavior often T-split connection with High Strength Bolt is governed by so many parameters, i.e., prying action, bolt's tension, shear failure and plastic failure of flange plates. Many researches regarding the structural behavior of the split-tee connection have been undertaken in other parts of the world, such as the, Americas, Japan and Europe, but in the domestic context, this is a pioneering study. Therefore, the purpose of this paper is to supply basic data for the design of T-split connection, and to verify the structural characteristics that define reactions to prying action, based on an experimental study.

Eunsa Memorial Science Museum and Colonial Science Technology (은사기념과학관(恩賜記念科學館)과 식민지 과학기술)

  • Jung In-Kyung
    • Journal of Science and Technology Studies
    • /
    • v.5 no.2 s.10
    • /
    • pp.69-95
    • /
    • 2005
  • Eunsa Memorial Science Museum is a political space to justify ruling colony. Japanese imperialism made use of science museum in ruling colony under the cloak of propagating science thoughts. The science museums made it natural to rule the inferior Joseon(Korea) by bring the concept of 'Great Science Empire' into relief. The exhibition, lecture, experiment and science movies propagated those colonial ruling ideology. This transplantation of the colonial science museumraised the following problems. First, the science museum was used as means for the propagation of political power. All the aspects of the architecture, exhibition, and operation of the colonial science museum propagated and supported the direction of political authority, and furthermore planted a rosy phantasm of 'Development' and 'Progression' into the colony. Second, The science technology of science museum was treated as 'Result' and 'Instrument'. Japanese imperialism denied that the science is a historical and cultural staple product; it instilled only the 'Instrumental Rationality' in the colony. Third, the science technology dealt in the colonial science museum was below the level. What they educated and set forth as domestic science was to cultivate the laborers people for the political power by internalizing modernistic discipline.

  • PDF

A Comparative Study on Domestic and Foreign Standards for Air Supply for the Improvement of a Smoke Control System for High-Rise Buildings (국내 고층건축물의 제연설비 성능 개선을 위한 국내·외 급기량 관련 기준 비교연구)

  • Kim, Hye-Won;Lee, Byeong-Heun;Jin, Seung-Hyeon;Lee, Su-Gak;Kim, Jung-Yup;Kwon, Young-Jin
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.105-111
    • /
    • 2019
  • In South Korea, smoke control systems are designed according to the fire safety standards NFSC501 and NFSC 501A. However, there is a problem in that the design values are incompatible when measuring the performance of the system after the design construction for calculating the leakage crack area described in the standards. Therefore, we compared the standards for smoke control systems from South Korea, Japan, and the United Kingdom. In South Korea, designs are conducted uniformly according to the NFSC 501A Manual, but in Japan and the United Kingdom, designs consider smoke temperature, duct loss, and fire floor air supply. Furthermore, they use larger values than in South Korea.

Seismic Performance of Rib Plate H Beam to Column Connections (리브로 보강된 기둥-보 접합부의 내진성능 평가)

  • Kim, Sung-Yong;Shin, Chang-Hoon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.6 no.1 s.20
    • /
    • pp.9-16
    • /
    • 2006
  • The moment resisting frame has been well-known as it had very excellent seismic performance, and it has been widely used and constructed in the design of a lot of buildings. However, the moment resisting frame system did not exert the seismic performance during the earthquake in Northridge and Kobe sufficiently, and it produced the crack or brittle fracture on the joint. this study was to ]m tests with the full-scale test subject as parameters of existence of H-beam web high tensile bolt shearing joint and reinforcement of H-flange rib. This researcher was to anticipate the decrease of number of high tensile bolts and the improvement of workability through the double shear joint by the experiment, and improve the seismic performance through the reinforcement of rib plate. In addition, this study was to prevent the brittle fracture by the stress concentration through the non scallop.

A Basic Study on The Architectural Characteristic of the Group Home in Japan (일본 그룹 홈의 건축적 특징에 관한 기초연구)

  • Yang, Yoon-Sil;Kim, Tae-Il
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.4
    • /
    • pp.248-256
    • /
    • 2014
  • According to data from the national office of Statistics Korea and Ministry of Health and Welfare, as the elderly population increases, the dementia elderly population continues to increase and its future population growth rate is expected to be even faster. In particular, the Dementia Management Act has been in effect since February 2012, and active efforts has been made for a policy for the dementia management. The purpose of this study is to establish standards on building plans based on the appropriate scale and spatial configuration on facilities planning for the elderly with dementia. Specifically, the basic data were collected with a request for a total of 103 points on the basis of a database of group homes in the survey managed by the Japan Association of Group Homes. Specific information of the research includes the management body of facilities operation, scale of the facilities, number of units and configuration of personal living space, and the collected survey data and drawings were statistically proceed and analyzed using the SPSS WIN 20.0. analysis results are summarized as follows. first, most of the group homes come to the small size of the 1-2 story home ; the approximate number of units is one or two per home, and each unit consists of nine rooms. second, a number of group homes with the building area of $300m^2$ have the U-shaped arrangement which is advantageous in the extension and facilities maintenance. In conclusion, this study is to be the fundamental data for judgments that can be used to establish standards for the facilities for the dementia elderly whose population continues to increase. In addition, further study is necessary to establish suitable design conditions of our country.