• Title/Summary/Keyword: 일반촬영 검사

Search Result 163, Processing Time 0.025 seconds

Usability Evaluation of Foot Pedal Switch in X-ray Radiography System (진단용 엑스선 촬영장치에서 발판 스위치의 유용성 평가)

  • Kwon, Hyeokjin;Jung, Hongmoon;Jung, Jaeeun;Jung, Kyunghwan;Won, Doyeon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.651-658
    • /
    • 2018
  • A foot pedal switch in the diagnosis x-ray radiography system has been researched to improve radiologic technologist works and patient satisfaction. The switch has been installed in the diagnosis x-ray radiography system used in domestic clinics. Quantitative evaluation has been conducted by measuring the exposure dose reproducibility test, tube voltage, mAs, and percentage average error. Qualitative evaluation has been conducted by analysis of the radiologic technologists questionnaire. In the quantitative evaluation for the use of the foot pedal switch, the coefficient of variation was less than 0.05 in the exposure dose reproducibility test. In the mAs test, percentage average error of ${\pm}20%$ was measured. There was no problem raised since it meets the all inspection standards of the diagnosis x-ray generator. In the qualitative evaluation, most of the opinions are that it has a clinical value for the foot pedal switch in the diagnosis x-ray radiography system. Therefore, developing the foot pedal switch for the diagnosis x-ray radiography system can improve effectively the rapidity and accuracy of the radiologic technologist work. In addition, it is effective in decreasing the x-ray exposure of patients and increasing satisfaction for the medical service due to reduction of retaking x-ray.

Diagnosis of Location and Size of Lesions using Chest X-ray Image (X-선 영상을 이용한 암의 위치 및 크기 진단)

  • Jung-Min, Son;Byung-Ju, Ahn
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.167-173
    • /
    • 2023
  • X-ray general radiography is the simplest and most important one to get a lot of information. Nevertheless, current x-ray general radiography does not observation in-depth observation. Information about the anatomy of the human body and changes in disease in x-ray general radiography can be obtained but it is difficult to determine the size and shape of the actual lesion due to the disadvantage of expanding the image. In this study, PA and LAT images were acquired and cancer magnification was calculated in the images by measuring the distance of cancer samples. By adjusting the magnification the actual cancer length and thickness were measured and compared with the CT image and the actual cancer sample size. After the PA and LAT images of the inserted 6.0 mm cancer sample were obtained and the magnification was corrected, the length was 5.9 mm and the thickness was 6.1 mm. This value was measured similarly to the actual. The problem of obtaining the magnification that needs to know the actual length from the detector to the cancer sample was secured by obtaining the magnification through PA and LAT images and it is possible to accurately measure the cancer sample size. X-ray general radiography may provide useful information in situations where CT imaging is difficult.

Analysis of Healthcare Convergence on Bacterial Contamination of Radiological Equipment in Emergency Rooms of General Hospitals (종합병원 응급실내의 영상의학과 장비에서의 세균 오염에 관한 보건학적 융합 분석)

  • Hong, Dong-Hee;Park, Mi-Soon
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.1
    • /
    • pp.51-59
    • /
    • 2017
  • It is to establish preliminary data about healthcare convergencr of infection control by performing a bacterial contamination test for CT scanner as well as general radiographic systems in the emergency rooms of general hospitals. The period was December 1 ~ December 31, 2015. It is detect in the emergency rooms of 7 medical facilities including 2 in Seoul, and 1 in Gyeonggi-do Province, and 2 in Jeonla-do Province, and 2 in Chungcheong-do Province. The surface contamination strains detected from CT scanner in the radiology department emergency rooms were Micrococcus species(4,5%), Stenotrophomonas maltophilia(9%), Enterococcus faecium(4.5%), Providencia stuartii(4.5), and Gram negative bacilli(4.5%). Also, the surface contamination strains detected from general radiographic system in the radiology department emergency rooms were Providencia stuartii(11%), Klebsiella pneumonia(3.5%), Stenotrophomonas maltophilia(11%), Pantoea species(11%), Acinetobacter baumannii(3.5%), Micrococcus species(3.5%), Escherichia coli(3.5%), Enterobacter species(3.5%), and Gram negative bacilli(11%). Considering that the regions of most detection were all the places closely related to patients, radiologists would have to thoroughly clean with alcohol before and after a test.

Patient exposure doses from medical x-ray examinations in Korea (진단방사선검사에서 환자피폭선량에 관한 연구)

  • Kim, You-Hyun;Choi, Jong-Hak;Kim, Sung-Soo;Oh, Yuw-Han;Lee, Chan-Hyeup;Cho, Pyong-Kon;Kang, Dae-Hyun;Lee, Young-Bae;Kim, Hyung-Chul;Kim, Chel-Min
    • Journal of radiological science and technology
    • /
    • v.28 no.3
    • /
    • pp.241-248
    • /
    • 2005
  • X-ray examinations represent the largest man-made source of radiation exposure for the population. The need for standardization of radiation exposures has been suggested and the guidance levels for various radiographic and radioisotope examinations has been proposed by the International Atomic Energy Aency(IAEA) as a safety standard. In many countries, the situation of medical radiographic exposures in each country should be researched before the appropriate guidance level is established. In this study, measurements of entrance surface dose, dose-area product(DAP), computed tomograghic dose index(CTDI) and mean glandular dose(MGD) were carried out in patients who underwent routine x-ray examinations, fluoroscopy, computed tomograghy and mamography in Korea. These measured quantities were compared with the results from the calculation method in previous study. And we suggested diagnostic reference levels in medical imaging in Korea.

  • PDF

Assessment of Radiation Dose Due to X-Ray Simple Series Examinations (X-선 단순 Series 촬영 시 피폭 선량 평가)

  • Gang, Eunbo;Hwang, Incheol;Shin, Woonjae
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.2
    • /
    • pp.81-88
    • /
    • 2014
  • In diagnostic radiology, each part is examined through serial radiography in most cases of general radiography. However, the reality is that, as for diagnostic reference level, measured values have been set up only for AP projection of each part and lateral projection. In the clinical setting, cumulative dose is incurred by serial radiography of patients, and this can make comparison of diagnostic reference level and cumulative exposure dose impossible or can lead to underestimation of diagnostic reference level. In this study, measurement of cumulative dose of serial radiography of each part revealed that when converting entrance surface dose to effective dose in case it is included in the exposure field, cumulative dose measured from a maximum of 38.06% to a minimum of 0.23% of individual dose limitation of the public. Also, when converting entrance surface dose of each part that is not included in the exposure field into effective dose, it measured from a maximum of 5% to a minimum of 0.04% of individual dose limitation of the public. Results of this study show entrance surface dose substantially increases in serial radiography of each part. Therefore, it is deemed that hospitals need to establish diagnostic reference level specifically, and subdivision of radiography orders for patients is also required in order to reduce unnecessary inspections. Moreover, the need of accurate exposure field is emphasized in case of inspection of several parts.

A Study on the Optimization of Exposure condition at Lumbar projection Using Blind Test (블라인드 테스트를 통한 요추 검사 시 조사 조건의 최적화 연구)

  • Park, Jikoon;Kim, Kyotae;Yoon, Inchan;Choi, Ilhong;Jung, Hyungjin;Kang, Sangsik;Noh, Sicheul;Jung, Bongjae
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.6
    • /
    • pp.389-395
    • /
    • 2013
  • This study intended to investigate the optimum conditions for lumbar test that has the highest level of irradiation conditions among general test sites. To to this, the most widely used irradiation conditions in terms of statistics were set as standards; test groups applied with DMF were selected; tests groups suitable for clinical trials were selected by using suggested patient dose. Blind tests were conducted by 10 specialists and radiologists. The results suggested that under the optimum conditions, the radiation dose reduction of 2.09 mGy, 4.42 mGy and 3.65 mGy can be achieved in forward-backward test, lateral test and 4-direction test, respectively. There is a need of further studies on the optimization of irradiation conditions in accordance with the conditions of patients.

Evaluation of Inflammatory Disease in the Nasal Cavity and Paranasal Sinuses using CT in Dogs and Cats (개와 고양이에서 컴퓨터단층촬영술을 이용한 비강의 염증성 질병 평가)

  • Choi, Ho-Jung;Lee, Ki-Ja;Park, Seong-Jun;Jeong, Seong-Mok;Song, Kun-Ho;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.27 no.1
    • /
    • pp.42-45
    • /
    • 2010
  • Inflammatory sinonasal disease was diagnosed in five dogs and two cats with clinical signs of nasal discharge and epistaxis. Survey radiography and CT were performed in all of patients. CT scan of the rostral cranium was performed with a thickness of 2 or 5 mm. Nasal cytology and culture from nasal smear were performed immediately after CT examination. Remarkable increase of opacity in the nasal cavities and frontal sinuses was observed in only 3 cases. On CT images, the cavitating lesions were isodense in nasal cavity (7 cases), frontal sinuses (3 cases), and nasopharynx (2 cases) with destruction of the nasal septum (4 cases), maxillary turbinates (5 cases), maxilla (3 cases), and hard palate (3 cases). The lesions were enhanced after intravenous contrast administration in 5 cases and were not enhanced in 2 cases. Inflammatory cells were observed in nasal cytology. Most of the cultures from nasal smear were bacteria. CT is useful to diagnose sinonasal disease and is more accurate in demonstrating the extent and character of lesions of nasal cavity than radiography.

Evaluation of the Patient Dose in Case of Standard Radiographic Examinations Using CR and DR (표준영상의학검사를 대상으로 한 CR과 DR에서의 환자선량평가)

  • Kim, Sang-Tae;Han, Beom-Hui
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.173-178
    • /
    • 2010
  • In projection radiography, two types of digital imaging systems are currently available, computed radiography (CR) and digital radiography (DR): a difference between them can be stated in terms of dose and image quality. In the Department of Radiology our hospital, a flat-panel DR equipment (Digital diagnost, Philips) and two CR systems (ADC Compact plus digitizer, AGFA) are employed. Eight standard radiographic examinations (Skull AP, Skull LAT, Chest PA, Chest LAT, Abdomen AP, L-spine AP, L-spine LAT, Pelvis AP) were considered: doses delivered to patients in terms of both entrance skin dose (ESD) were calculated and compared in order to study the dosimetric discrepancies between CR and DR. Assessment of image quality is undertaken by Consultant Radiologists to ensure that the quality criteria for diagnostic radiographic images of the European guidelines were met. Results showed that both ESD in DR are lower than that in CR; all images met the criteria in the European Guidelines for both modalities and were used for reporting by the radiologists. Since the operators are the same and the image quality is comparable in both modalities, this study shows that in the considered examinations, DR can perform better than CR from a dosimetric point of view.

Patient Radiation Exposure Dose Evaluation of Whole Spine Scanography Due to Exposure Direction (Whole Spine Scanography의 검사방향에 따른 환자 선량 평가)

  • Kim, Jung-Su;Seo, Deok-Nam;Kwon, Soon-Mu;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • Whole spine scanography (WSS) is a radiological examination that exposes the whole body of the individual being examined to x-ray radiation. WSS is often repeated during the treatment period, which results in a much greater radiation exposure than that in routine x-ray examinations. The aims of the current study were to evaluate the patient dose of WSS using computer simulation, image magnification and angulation of phantom image using different patient position. We evaluated the effective dose(ED) of 23 consecutive patients (M : F = 13:10) who underwent WSS, based on the automatic image pasting method for multiple exposure digital radiography. The Anterior-Posterior position(AP) and Posterior-Anterior position( PA) projection EDs were evaluated based on the PC based Monte Carlo simulation. We measured spine transverse process distance and angulation using DICOM measurement. For all patient, the average ED was 0.069 mSv for AP position and 0.0361 mSv for PA position. AP position calculated double exposure then PA position. For male patient, the average ED was 0.089 mSv(AP) and 0.050 mSv(PA). For female patient, the average ED was 0.0431 mSv(AP) and 0.026 mSv(PA). The transverse process of PA spine image measured 5% higher than AP but angulation of transverse process was no significant differences. In clinical practice, just by change the patient position was conformed to reduce the ED of patient. Therefor we need to redefine of protocol for digital radiography such as WSS. whole spine scanography, effective dose, patient exposure dose, exposure direction. protocol optimization.

A Study on the Repeat Tests for Diagnosis at a Tertiary Hospital in Taegu City (3차진료기관(3次診療機關)과 환자의뢰기관간(患者依賴機關間)의 중복검사(重複檢査))

  • Park, Jae-Yong;Kim, Gui-Young
    • Journal of Preventive Medicine and Public Health
    • /
    • v.26 no.3 s.43
    • /
    • pp.457-468
    • /
    • 1993
  • This study was conducted to investigate the repeat test rate for diagnosis at a tertiary hospital for the outpatients who were referred themselves to the hospital by the clinics and other medical facilities. The study population consisted of 498 patients who visited outpatient department of internal medicine, general surgery, orthopedic surgery and neurosurgery in the hospital between March 16 and April 11, 1992. This study was surveyed by the questionnaire about the tests for diagnosis at first level medical facilities, and then, was investigated by the medical record about the tests for diagnosis at a tertiary hospital. The proportion of test among the patients who utilized the first level medical facilities was 20.9% for the X-ray test, 10.6% for the urinalysis, 9.0% for the electrocardiogram, 3.4% for the computer tomogram and 6.4% for the ultrasonogram. At the tertiary hospital, the X-ray test was 45.2%, the liver function test was 24.1%, the urinalysis was 19.1%, and the electrocardiogram was 15.7%. The proportion of patients who possessed results of test for diagnosis at the first level medical facilities was 76.5% for the computer tomogram, and 31.3% for the ultrasonogram. As the repeat test rate between the first level medical facilities and the tertiary hospital, the thyroid function test was the first rank as 71.4%, the second rank was the routine CBC as 67.9%, and the third rank was the X-ray test as 64.4%. But among the patients that brought the result for tests at the first level medical facilities, the repeat test rate was as follow : the routine CBC was 75.0%, the liver function test was 72.1%, and the computer tomogram was 15.4%.

  • PDF