• Title/Summary/Keyword: 인화성 액체

Search Result 52, Processing Time 0.027 seconds

Propagation Speed and Characteristic Analysis of Flame in Compartment Fires of Flammable Liquids (인화성 혼합유의 구획 화재에 의한 화염의 전파 속도 및 특성 해석)

  • Joe, Hi-Su;Lee, Jae-Ou;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.29 no.3
    • /
    • pp.31-36
    • /
    • 2015
  • This study analyzed the flame characteristics when igniting 200 ml of flammable liquids containing equal parts gasoline and another flammable liquid. These mixtures were used to fill a divided space in a simulation. The length of one side of the divided space was 2,000 mm, and the length of the combustion device was 1,000 mm. The mixture with alcohol had the highest flame propagation speed (0.7 s), while the mixture with light oil showed the lowest (1.2 s). The gasoline and acetone mixture reached peak flame in 25.5 s, at the highest speed, while the mixture with light oil reached peak flame in 163.7 s at the lowest speed. The gasoline and light oil showed the longest continuous combustion time (332.7 s), while the gasoline and paint thinner showed the shortest (121.5 s). A fire inspector who is examining the scene of a fire needs to analyze both the statements of the first eyewitness and the flame characteristics collectively.

A study on Preventive Measures for Fire and Explosion Accidents During Acetic Acid Handling in Manufacturing the Semiconductor Material (반도체 소재 제조 공정에서 아세트산 취급 작업 시 발생한 화재·폭발 사고 예방대책에 관한 연구)

  • Dae Joon Lee;Sang Ryung Kim;Sang Gil Kim;Kyo Shik Park;Joon Won Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.2
    • /
    • pp.65-70
    • /
    • 2023
  • Flammable materials used in semiconductor supply facilities are manufactured at high temperatures and high pressures, and as the semiconductor industry becomes more sophisticated and larger, the amount of materials used is rapidly increasing. Recently, fires and explosions occurred during the handling of acetic acid, which is a raw material for making products in the semiconductor material manufacturing process. Overall problems such as lack of air inflow prevention for fire and explosion prevention were identified. Therefore, in this study, in order to accurately identify the cause of the accident and prevent fire and explosion that may occur in the process of handling large amounts of flammable liquids, opinions from various perspectives, such as construction of facilities such as hoppers, installation of AOPS components, and change in workers' perceptions would like to present.

Numerical Study on Atmospheric Dispersion and Fire Possibility in Toluene Leakage (톨루엔 누출 시 대기확산 및 화재가능성에 관한 수치해석 연구)

  • Ko, Jae Sun;Kim, Joo-Seok
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.1-10
    • /
    • 2017
  • This study examined the risk of accidents when handling hazardous materials in hazardous materials storage facilities without safety facilities. In the case of illegal dangerous cargo containers, the burning rate is very fast in the case of fire, which leads to explosions, that are damaging and difficult to control. In addition, accidents that occur in flammable liquid hazardous materials are caused mostly by accidents that occur in the space due to leakage. Therefore, the variables that affect these accidents were derived and the influence of these variables was investigated. Numerical and computational fluid dynamics programs were used to obtain the following final results. First, when a flammable liquid leaks into a specific space, it is influenced by temperature and relative humidity until a certain concentration (lower limit of combustion) is reached. In the case of temperature, it was found that the reaching time was shorter than the flash point In addition, the effect of variables on pool fire accidents of leakage tanks is somewhat different, but the variables that have the largest influence are the wind speed. Therefore, it is expected that the results of this study will be used as basic data for similar numerical analysis and it will provide useful numerical information about the accidental leakage of hazardous materials under various research conditions.

A Study on the Fire Risk Assesment of Solvent-based Paints (유성페인트의 화재 위험성평가에 관한 연구)

  • Lee, Bong-Woo;Kwon, Seong-Pil
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.1-7
    • /
    • 2017
  • Currently, flammable liquids account for more than 87 wt% of the hazardous materials in circulation in Korea, and paint products are the most commonly used mixed hazardous materials. Therefore, one of the most urgent and important issues is that we have to secure the safety for manufacturing, storage and transport of paint products. In this study we investigated and analyzed the domestic hazardous materials safety management method, the international GHS test method and so forth. We tested risks for a variety of oil paints and found a relation between the results. Furthermore, the risk test method and criteria adapted for domestic situation was presented. Paints were classified as hazardous or non-hazardous according to the results of the flash point test, the amount of flammable liquid or the UN-combustion persistence test. It was revealed from the test results of 6 kind of oil-based paints using different resins that they were hazardous materials with very high risks and belonged to the Category 1 or the Category 2.

A Study on Flammability Risk of Flammable Liquid Mixture (가연성 액체 혼합물의 인화 위험성에 관한 연구)

  • Kim, Ju Suk;Koh, Jae Sun
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.4
    • /
    • pp.701-711
    • /
    • 2020
  • Purpose: In this study, the risk of flammability of a liquid mixture was experimentally confirmed because the purpose of this study was to confirm the increase or decrease of the flammability risk in a mixture of two substances (combustible+combustible) and to present the risk of the mixture. Method: Flash point test method and result processing were tested based on KS M 2010-2008, a tag sealing test method used as a flash point test method for crude oil and petroleum products. The manufacturer of the equipment used in this experiment was Japan's TANAKA. The flash point was measured with a test equipment that satisfies the test standards of KS M 2010 with equipment produced by the company, and LP gas was used as the ignition source and water as the cooling water. In addition, when measuring the flash point, the temperature of the cooling water was tested using cooling water of about 2℃. Results: First of all, in the case of flammable + combustible mixtures, there was little change in flash point if the flash point difference between the two substances was not large, and if the flash point difference between the two substances was low, the flash point tended to increase as the number of substances with high flash point increased. However, in the case of toluene and methanol, the flash point of the mixture was lower than that of the material with a lower flash point. Also, in the case of a paint thinner, it was not easy to predict the flash point of the material because it was composed of a mixture, but as a result of experimental measurement, it was measured between -24℃ and 7℃. Conclusion: The results of this study are to determine the risk of mixtures through experimental studies on flammable mixtures for the purpose of securing the effectiveness of the details of the criteria for determining dangerous goods in the existing dangerous goods safety management method and securing the reliability and reproducibility of the determination of dangerous goods Criteria have been presented, and reference data on experimental criteria for flammable liquids that are regulated in firefighting sites can be provided. In addition, if this study accumulates know-how on differences in test methods, it is expected that it can be used as a basis for research on risk assessment of dangerous goods and as a basis for research on dangerous goods determination.

Experimental Study on Ignition and Explosion Hazard by Measuring the Amount of Non-volatile (NVR) and Explosion Limit of Biodiesel Mixture (바이오디젤 혼합물의 가열잔분측정과 폭발한계 측정을 통한 발화 및 폭발위험성에 대한 실험적인 연구)

  • Kim, Ju Suk;Koh, Jae-Sun
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.1
    • /
    • pp.182-193
    • /
    • 2022
  • Purpose: By measuring and evaluating the risk of biodiesel through non-volatile residue (NVR) and flash point and explosion limit measurement at a specific temperature according to ASTM test standards, the risk of chemical fire causative substances is identified and a universal evaluation method By derivation and securing the risk-related data of the material, it can be used for the identification and analysis of the cause of the fire, and it can be applied to the risk assessment of other chemical substances Method: In order to measure the risk of biodiesel, it was measured using the non-volatile residue(NVR) measurement method, which measures how much flammable liquid is generated at a specific temperature. Heating was tested by applying KS M 5000: 2009 Test Method 4111. In addition, the flash point was measured using the method specified in ASTM E659-782005, and the energy supply method was measured using the constant temperature method. In addition, the explosion limit measurement was conducted in accordance with ASTM E 681-04 「Standard test method for concentration limits of flammability of chemicals(Vapors and gases)」 test standard. Result: As a result of checking the amount of combustible liquid by the non-volatile residue (NVR)measurement method, the non-volatile residue(NVR) of general diesel when left at 105±2℃ for 3 hours was about 30% (70% of volatile matter) and about 4% of biodiesel. In addition, similar results were obtained for the non-volatile residue(NVR)heating temperature of 150±2℃, 3 hours and 200±2℃ for 1 hour, and white smoke was generated at 200℃ or higher. In addition, similar values were obtained as a result of experimentally checking the explosion (combustion) limits of general diesel, general diesel containing 20% biodiesel, and 100% biodiesel. Therefore, it was confirmed that the flammability risk did not significantly affect the explosion risk. Conclusion: The results of this study suggested the risk judgment criteria for mixtures through experimental research on flammable mixtures for the purpose of securing the effectiveness, reliability, and reproducibility of the details of the criteria for determining dangerous substances in the existing Dangerous Materials Safety Management Act. It will be possible to provide reference data for the judgment criteria for flammable liquids that are regulated in the field. In addition, if the know-how for each test method is accumulated through this study, it is expected that it will be used as basic data in the research on risk assessment of dangerous substances and as a basis for research on the determination of dangerous substances.

Evaluation of Peak Overpressure and Impulse Induced by Explosion (폭발에 따른 최대과압 및 충격량 평가)

  • Yoon, Yong-Kyun
    • Explosives and Blasting
    • /
    • v.34 no.4
    • /
    • pp.28-34
    • /
    • 2016
  • Empirical model, phenomenological model, and CFD model have been used to evaluate the blast effects produced by explosion of explosives, flammable gas and liquid or dust. TNT equivalence method which is one of empirical models has been widely used as it is simple. In this study, new peak overpressure-scaled distance and scaled impulse-scaled distance equations are induced through fitting data from the curves given by TNT equivalence method. If the TNT equivalent mass is calculated, it is possible to estimate the peak overpressure and impulse using the regression equations. Differences of peak overpressure with yield factor which is a component of TNT equivalence method are found to be great in near-by distances from explosion source where the increase in overpressure is very steep, but the differences are getting smaller as the distances increase.

안전관리 - 용접공사의 화재.폭발 등 안전사고 예방대책(2)

  • 대한설비건설협회
    • 월간 기계설비
    • /
    • s.267
    • /
    • pp.65-71
    • /
    • 2012
  • 지난 8월 13일 서울 종로구 소격동 국립현대미술관 서울관 공사현장에서 화재 발생으로 4명이 숨지고 18명이 중경상을 입는 등 많은 인명피해를 냈다. 이처럼 인명피해가 컸던 것은 우레탄 공사를 하던 밀폐공간에서 불이 나면서 발생한 유독가스 때문에 사람들이 제대로 대피하지 못했기 때문이다. 사고발생 원인으로 '용접공사' 여부를 놓고 공방을 벌였으나 경찰은 '전기합선'이라는 잠정 결론을 내렸다. 지난 2008년 1월에 발생한 경기도 이천 냉동창고 화재는 40명의 목숨을 앗아갔다. 화재 원인은 냉동배관을 설치하면서 전기 용접을 하기 위해 불을 붙였다가 공기 중에 차 있던 유증기(기름증기)와 만나면서 폭발이 일어난 것이었다. 인화성 액체(유기용제)를 취급하는 건설현장에서는 다량의 유증기가 발생할 수 있을 뿐만 아니라 건조한 조건일 경우 정전기에 의한 화재 폭발 누출사고의 발생 위험이 높다. 기계설비공사에서 화재, 폭발 위험성이 가장 큰 공사는 용접공사이기에 용접공사를 할 때 화재, 감전의 위험성을 배제한 후 공사에 들어간다. 용접으로 인한 사망사고의 유형으로는 용접 중 추락사고와 더불어 용접 불꽃이 가연성 물질에 옮겨 붙어 화재 발생으로 인한 질식사, 용접작업 중 절연체가 파손된 용접기 홀더 충전부의 접촉으로 인한 감전사 등이 있다. 본지는 용접으로 인한 화재 감전 등의 사고발생을 미연에 방지하기 위해 안전작업 수칙 및 안전수칙 체크리스트, 재해사례를 지난호부터 시리즈로 연재하고 있다.

  • PDF

Combustion Characteristics of Pool and Whirl Fire on Methanol by Height of Fire Source using the Small Scale (화점높이 변화에 따른 메탄올의 소규모 Pool 및 Whirl Fire의 연소특성)

  • Park, Hyung-Ju
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.73-78
    • /
    • 2012
  • This study is intended to understand flame behavior of pool and whirl fire by height of fire source. Liquid fuel was methanol which is used in many studies for pool and whirl fire. Size of vessel was $100{\times}100{\times}50$ and the vessel was made by stainless steel. Combustion time, mass loss rate, flame temperature, flame height and air entrainment rate from the outside to flame were measured, and flame behavior was visualized with video camera. Based on the experiment, it was found that combustion characteristics by height of fire source got a more effect on whirl fire than pool fire.

A Study on the Estimation Model of Liquid Evaporation Rate for Classification of Flammable Liquid Explosion Hazardous Area (인화성액체의 폭발위험장소 설정을 위한 증발율 추정 모델 연구)

  • Jung, Yong Jae;Lee, Chang Jun
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.4
    • /
    • pp.21-29
    • /
    • 2018
  • In many companies handling flammable liquids, explosion-proof electrical equipment have been installed according to the Korean Industrial Standards (KS C IEC 60079-10-1). In these standards, hazardous area for explosive gas atmospheres has to be classified by the evaluation of the evaporation rate of flammable liquid leakage. The evaporation rate is an important factor to determine the zones classification and hazardous area distance. However, there is no systematic method or rule for the estimation of evaporation rate in these standards and the first principle equations of a evaporation rate are very difficult. Thus, it is really hard for industrial workplaces to employ these equations. Thus, this problem can trigger inaccurate results for evaluating evaporation range. In this study, empirical models for estimating an evaporation rate of flammable liquid have been developed to tackle this problem. Throughout the sensitivity analysis of the first principle equations, it can be found that main factors for the evaporation rate are wind speed and temperature and empirical models have to be nonlinear. Polynomial regression is employed to build empirical models. Methanol, benzene, para-xylene and toluene are selected as case studies to verify the accuracy of empirical models.