• Title/Summary/Keyword: 인체공학형

Search Result 81, Processing Time 0.027 seconds

Development of a Upper Body Micropostural Classification Scheme Based on Perceived Joint Discomfort (인체 관절 동작의 지각 불편도에 근거한 상체의 자세 분류 체계의 개발)

  • Kee, Do-Hyung
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.24 no.3
    • /
    • pp.447-455
    • /
    • 1998
  • It is important to identify and evaluate poor working postures properly to prevent work-related musculoskeletal disorders. The purpose of this study is to develope a new upper body micropostural classification scheme for analyzing postural stress in industry. Most of the existing postural classification schemes were based either on the literature, or on simple biomechanical principles, or on a subjective ranking system. The scheme suggested in this study was based on perceived joint discomfort measured through experiment, in which nineteen subjects participated and the magnitude estimation method was employed to obtain subjects' joint discomfort. Also, the criteria for evaluating postural stress of working postures were presented for practitioners of health and safety to be able to redesign working methods and workplaces, which was based on maximum holding time by Miedema and other people. It is expected that the scheme developed in this study could be used as a valuable tool when evaluating working postures.

  • PDF

Produced Body Customized 3D Print Finger Brace using Dicom File (Dicom file을 이용하여 만든 신체 맞춤형 3D print 손가락 보조기 제작)

  • Choi, Hyeun-Woo;Park, Ji-Eun;Kim, Jung-Hun;Seo, An-Na;Lee, Jong-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.597-603
    • /
    • 2019
  • We obtained a Dicom file using a CT (Computed Tomography), a diagnostic test device used in clinical practice. Dicom files and 3D programs, and finger printers with 3D printers. Because the finger brace is intended for the human body, the accuracy of the shape is very important. 3D Print has the advantage of high precision, variety of materials, and short output time. In clinic, aluminum protector or medical device manufacturer's finger protector is limited. By creating a finger brace with a 3D printer, we expect to be able to apply a precise form of a custom finger brace to the patient that can be used to treat a patient's finger trauma, illness, or deformity.

A Field Measuring Study on the Thermal Environment of Human Surrounding in the Classroom Equipped with Ceiling Unit (천장형 유닛을 설치한 교실 내의 인체 주변 온열환경에 관한 실측연구)

  • Cho Sung-Woo;Im Young-Bin;Lee Kyung-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.3
    • /
    • pp.240-246
    • /
    • 2006
  • This paper performed to investigate on vertical temperature distribution, effective draft temperature (ETD) and PMV (Predicted Mean Vote) in the classroom, which is located YangSan city (Kyungsangnam-Do), Korea, is equipped with ceiling unit. The vertical temperature difference between F.L+10 cm (ankle) and F.L+120 cm (neck) of a measuring point which is adjacent corridor in the classroom showed about $1^{\circ}C$ but of measuring point which is adjacent outdoor expressed up to $4^{\circ}C$, The effective draft temperature (ETD) is -2.3 and -0.52 and 0.67 at near ceiling unit but is 1.2 and 3.3 at far from ceiling unit. The PMV of total classroom showed the range of 'Cold' and 'Slightly Cold.' Therefore, to achieve comfort condition in the classroom is equipped with ceiling unit, the location of ceiling unit and discharge angle and discharge distance from ceiling unit are very important elements.

Multi-Region based Radial GCN algorithm for Human action Recognition (행동인식을 위한 다중 영역 기반 방사형 GCN 알고리즘)

  • Jang, Han Byul;Lee, Chil Woo
    • Smart Media Journal
    • /
    • v.11 no.1
    • /
    • pp.46-57
    • /
    • 2022
  • In this paper, multi-region based Radial Graph Convolutional Network (MRGCN) algorithm which can perform end-to-end action recognition using the optical flow and gradient of input image is described. Because this method does not use information of skeleton that is difficult to acquire and complicated to estimate, it can be used in general CCTV environment in which only video camera is used. The novelty of MRGCN is that it expresses the optical flow and gradient of the input image as directional histograms and then converts it into six feature vectors to reduce the amount of computational load and uses a newly developed radial type network model to hierarchically propagate the deformation and shape change of the human body in spatio-temporal space. Another important feature is that the data input areas are arranged being overlapped each other, so that information is not spatially disconnected among input nodes. As a result of performing MRGCN's action recognition performance evaluation experiment for 30 actions, it was possible to obtain Top-1 accuracy of 84.78%, which is superior to the existing GCN-based action recognition method using skeleton data as an input.

The Study on the Implementation of the X-Ray CT System Using the Cone-Beam for the 3D Dynamic Image Acquisition (3D 동영상획득을 위한 Cone-Beam 형 X-Ray CT 시스템 구현에 관한 연구)

  • Jeong, Chan-Woong;Jun, Kyu-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.4
    • /
    • pp.370-374
    • /
    • 2009
  • In this paper, we presents a new cone beam computerized tomography (CB CT) system for the reconstruction of 3 dimensional dynamic images. The system using cone beam has less the exposure of radioactivity than fan beam, relatively. In the system, the reconstruction 3-D image is reconstructed with the radiation angle of X-ray in the image processing unit and transmitted to the monitor. And in the image processing unit, the Three Pass Shear Matrices, a kind of Rotation-based method, is applied to reconstruct 3D image because it has less transcendental functions than the one-pass shear matrix to decrease a time of calculations for the reconstruction 3-D image in the processor. The new system is able to get 3~5 3-D images a second, reconstruct the 3-D dynamic images in real time.

Proposition of Korean Type Powered Wheelchair Seat Standards According to Age of the Human Scale (연령별 인체 치수에 따른 한국형 전동휠체어 좌석 표준규격 제언)

  • Kim, S.E.;Song, B.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.3
    • /
    • pp.237-243
    • /
    • 2015
  • As one of the most widely used assistive technology devices for the disabled in Korea, the powered wheelchair conforms to KS P ISO 7176-5 standard size which uses original version of international standard, ISO 7176-5 without technological modification. However, the international standard is not suitable for the disabled in Korea because it defines the size of wheelchair based on the body size of foreigners, which causes imbalanced posture due to limitation of movement or rotation of pelvis, pressure ulcer incidence due to excessive pressure on the thigh or popliteal space and calf, and safety of reduction due to improper posture. This study suggested the guidance of size for powered wheelchair based on human body size examined by Korean Agency for Technology and Standards, showing a great difference from the size defined in KS P ISO 7176-5 and accordingly redefinition for the size of powered wheelchair is needed.

  • PDF

Development and Evaluation of an Impulsive Force Test Method for Wearable Airbags (착용형 에어백의 충격력 시험 방법개발 및 평가)

  • Park, Jin-O;Kim, Young-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.597-602
    • /
    • 2021
  • Even in the era of the 4th industrial revolution, the prevention of industrial accidents is still an important issue in industrial sites. In solving the problem of industrial safety, a product can be difficult to market if there is a lack of standard or method for a reliable performance evaluation. The purpose of this study was to develop and evaluate a test method for a wearable airbag product for protecting the body from falls that was newly developed to respond to fall accidents in industrial sites. As a research method, reliable evaluation standards were developed and applied through four stages of the evaluation and development process (Step 1: Product review, Step 2: Data research, Step 3: Expert meeting, Step 4: Drawing evaluation standard). In addition, the impact force was evaluated according to the developed evaluation standard. The fall impact force obtained through the evaluation showed a reduction effect of approximately 96% compared to the existing impact force. Therefore, the fall impact force was reduced significantly when the airbag was applied. This will enable new convergence products to be launched on the market and produce an environment where industrial workers can work safely.

Development of Personalized Exercise Prescription System based on Kinect Sensor (Kinect Sensor 기반의 개인 맞춤형 운동 처방 시스템 개발)

  • Woo, Hyun-Ji;Yu, Mi;Hong, Chul-Un;Kwon, Tae-Kyu
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.3
    • /
    • pp.593-605
    • /
    • 2022
  • The purpose of this study is to investigate the personalized treacmill exercise analysis using a smart mirror based on Kinect sensor. To evaluate the performance of the development system, 10 health males were used to measure the range of the hip joint, knee joint, and ankle joint using a smart mirror when walking on a treadmill. For the validity and reliability of the development system, the validity and reliability were analyzed by comparing the human movement data measured by the Kinect sensor with the human movement data measured by the infrared motion capture device. As a result of validity verification, the correlation coefficient r=0.871~0.919 showed a high positive correlation, and through linear regression analysis, the validity of the smart mirror system was 88%. Reliability verification was conducted by ICC analysis. As a result of reliability verification, the correlation coefficient r=0.743~0.916 showed high correlation between subjects, and the consistency for repeated measurement was also very high at ICC=0.937. In conclusion, despite the disadvantage that Kinect sensor is less accurate than the motion capture system, Kinect is it has the advantage of low price and real-time information feedback. This means that the Kinect sensor is likely to be used as a tool for evaluating exercise prescription through human motion measurement and analysis.

The Algorithm Improved the Speed for the 3-Dimensional CT Video Composition (3D CT 동영상 구성을 위한 속도 개선 알고리즘)

  • Jeong, Chan-Woong;Park, Jin-Woo;Jun, Kyu-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.2
    • /
    • pp.141-147
    • /
    • 2009
  • This paper presents a new fast algorithm, rotation-based method (RBM), for the reconstruction of 3 dimensional image for cone beam computerized tomography (CB CT) system. The system used cone beam has less exposure time of radioactivity than fan beam. The Three-Pass Shear Matrices (TPSM) is applied, that has less transcendental functions than the one-pass shear method to decrease a time of calculations in the computer. To evaluate the quality of the 3-D images and the time for the reconstruction of the 3-D images, another 3-D images were reconstructed by the radon transform under the same condition. For the quality of the 3-D images, the images by radon transform was shown little good quality than REM. But for the time for the reconstruction of the 3-D images REM algorithm was 35 times faster than radon transform. This algorithm offered $4{\sim}5$ frames a second. It meant that it will be possible to reconstruct the 3-D dynamic images in real time.

Study On The Development of Mobile Shampoo Device Using Ozone Water For Good hair condition (모발에 좋은 오존수를 이용한 이동식 샴푸 장치 개발에 관한 연구)

  • Kim, Duck-Sool
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.394-399
    • /
    • 2017
  • The goal of this study is to suggest the technology and the way of developing ergonomic shampoo device, which is able to adjust the height and to be devided, and it uses ozone water. As a result of developing the device, it can complete better the effect of preventing water splash than existing devices by making neck holding part higher. And it is also made with ergonomic design, therefore, the head of shampoo candidate can be drawn into it more easily. By adjusting water temperature($38^{\circ}C$) to candidate's taste through water heater attached to water bucket, when a candidate is being shampooed, it can help keep warm shampooing without delaying. We could know the process through temperature sensor. And we could also know the utility of its own sterilization(1PPM) and purification. Finally, ozone water was measured for 20 minutes and the ozone concentration was measured to be less than 1 PPM to ensure stability. All parts of the mobile shampoo stand together with the hot water device and the ozonated water conversion device were designed so as not to be inconvenient for the user to use.