• Title/Summary/Keyword: 인장 강도

Search Result 3,706, Processing Time 0.032 seconds

Effects of Strain Rate and Water Saturation on the Tensile Strength of Rocks (변형률 속도 및 수분포화가 암석의 인장강도에 미치는 영향)

  • Jung, Woo-Jin
    • Tunnel and Underground Space
    • /
    • v.20 no.2
    • /
    • pp.119-124
    • /
    • 2010
  • Hopkinson's effect tests were carried out for various strain rates on three different types of rock in both saturated and dry states in order to examine the effects of strain rate and water saturation on tensile strength. The tensile strength increased with the increase of the strain rate not only in dry state but also in saturated state. It was also especially recognizable that the dynamic tensile strength of rock in the dry state was proportional to approximately a one-third multiple of strain rate no matter what the type of rock. It was found that water saturation decreased tensile strength in the dry state of sandstone and tuff, both with high porosity, but no significant difference could be recognized between the dry and the saturated states of granite, which has a low porosity of 0.49%.

자동차용 강판의 온도에 따른 기계적 특성

  • Hyeon, Ju-Sik;Lee, Bo-Ryong;Mun, Man-Bin
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2010.05a
    • /
    • pp.39.1-39.1
    • /
    • 2010
  • 겨울철 혹한지방에서의 차량운행 또는 여름철 혹서지방에서의 장시간 차량 운행시 차체를 구성하고 있는 강판에는 약 $-50^{\circ}C{\sim}150^{\circ}C$의 온도환경에 처하게 된다. 따라서 이러한 저온 고온 환경하에서 차체 충돌상품성 예측 및 충돌안전 설계를 위해 온도에 따른 차체 강판의 기계적 물성평가가 요구된다. 이를 위해 본 연구에서는 자동차용 충돌부재에 주로 쓰이는 HS440MPa, HS590MPa급 냉연 고장력 강판에 대해 $-60^{\circ}C{\sim}200^{\circ}C$의 온도범위로 저온 고온 인장시험을 수행 하였다. 각각의 인장시험 결과로부터 온도 별 항복강도, 인장강도, 연신율, 가공경화지수 등 기계적 물성 변화를 평가하였다. 저온 고온 인장시험은 ZWICK Z250 만능재료시험기를 사용하였고 KS5호 규격의 인장시편을 사용하였으며, 시편에 충분한 온도를 가하기 위하여 목표온도 도달 후 20분간 유지한 뒤 인장시험을 수행하였다. 인장시험결과 HS440MPa, HS590MPa급 두 강종 모두 온도가 낮아질수록 강도 및 연신율 등이 증가하였고, 온도가 증가할수록 강도 및 연신율 등 기계적 물성이 저하 되었다. 즉, 우리가 주로 평가해왔던 상온($25^{\circ}C$)에 비해 저온 고온 환경하에서는 강판의 기계적 물성 변화가 큰 것을 알 수 있다. 따라서 혹한 또는 혹서 지방 등 온도차이가 큰 운행환경하에서의 차체 강도 및 충돌안전성 확보를 위해 온도에 따른 강판의 정확한 물성평가가 필요하고 차체 설계시 온도에 따른 강도변화를 충분히 고려하여야 한다.

  • PDF

Cleavage Dependent Indirect Tensile Strength of Pocheon Granite Based on Experiments and DEM Simulation (포천화강암의 결에 따른 간접인장강도 특성에 대한 실험 및 개별요소 수치해석)

  • Zhuang, Li;Diaz, Melvin B.;Jung, Sung Gyu;Kim, Kwang Yeom
    • Tunnel and Underground Space
    • /
    • v.26 no.4
    • /
    • pp.316-326
    • /
    • 2016
  • The purpose of this study is to investigate the influence of cleavages on indirect tensile strength (ITS) of the granite. Brazilian disc tests and ring tests with three different hole sizes were performed. 2D DEM (Discrete Element Method) simulation was employed to further understand the failure process during the tests and the mechanism behind. Results show that ITS decreases across hardway, grain and rift cleavage. Measured average ITS from ring tests is about 2.5 ~ 6.4 times of those measured from Brazilian disc tests, and it decreases with increasing ratio of diameters of inner hole and specimen. Failure pattern in ring tests is influenced by both hole size and relative positions of cleavages parallel and perpendicular to the loading direction.

Tension Stiffening Effect of RC Tension Members Reinforced with Amorphous Steel Fibers (비정질 강섬유로 보강된 철근콘크리트 인장부재의 인장강화효과)

  • Park, Kyoung-Woo;Lee, Jun-Seok;Kim, Woo;Kim, Dae-Joong;Lee, Gi-Yeol
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.5
    • /
    • pp.581-589
    • /
    • 2014
  • This paper presents the tension stiffening behavior from experimental results of each 6 amorphous steel fibers and normal steel fibers reinforced direct tensile specimens with the main variables such as cover thickness to bar diameter ratio. A tension stiffening effect for steel fiber reinforced RC tension members improve on the increase in cover thickness, and also amorphous steel fiber is usually superior to normal steel fiber. The reinforcement of steel fibers controlled the splitting cracks and led to significant increase in the tension stiffening effect. In particular, if cover thickness is more than twice the bar diameter, the amorphous steel fiber reinforced specimen is controlled the splitting crack and increased the tension stiffening effect. And, the tension stiffening effect of amorphous steel fiber reinforced concrete tension members is different to current structural design code provision.

Tensile Strength Changes of Pinus densiflora root in Fire Damaged Forest Area (산불피해지에 있어서 소나무 뿌리의 인장강도특성 변화)

  • Cha, Du Song;Oh, Jae-Heun;Lee, Jung Su
    • Journal of Korean Society of Forest Science
    • /
    • v.97 no.4
    • /
    • pp.392-397
    • /
    • 2008
  • To characterize the root strength changes of Pinus densiflora by elapsed years after forest fire, we measured and analyzed the tensile force and strength of the roots using the universal testing machine for 4 years. The deterioration rate of the root strength was higher in small diameter class than that in large diameter class. Especially, the deterioration was highest of the root strength at the second year in all surveyed diameter classes and the mean deterioration rate of the root strength was 61% by that time. The tensile strength based on the simulation by ordinary differential equations deteriorated more than 50% in all diameter classes within 2 years after forest fire.

Strength and Modulus Relationship of Concrete for Rigid Pavement (포장용 콘크리트의 강도 및 탄성계수 상관관계식)

  • Yang, Sung-Chul;Park, Jong-Won
    • International Journal of Highway Engineering
    • /
    • v.9 no.4
    • /
    • pp.205-213
    • /
    • 2007
  • Strength relationships are presented through experimental data from the concrete strength tests in this study. Various strength tests such as the compressive, flexural, and splitting tensile strength and the modulus of elasticity are included. An experimental work was performed to determine the various strength characteristics for various mix designs. Three different coarse aggregates such as granite, limestone, sandstone were used and included were fine aggregates such as natural sand, washed sand and crushed sand. Also included was cement amount as experimental variable. It was confirmed that each strength value with respect to curing time is to follow a typical strength development curve. With this somewhat reliable test results various strength relationships such as flexural strength-compressive strength, splitting tensile strength-compressive strength, modulus of elasticity-compressive strength, splitting tensile strength-flexural strength were analyzed through statistics. Experimental data were well fitted to the 0.5-power relationship of flexural strength and compressive strength which has been commonly accepted. The splitting tensile strength is expected to be best in the linear relationship from the flexural strength data. Finally splitting tensile strength was found to be proportional to the 0.87 power of the cylindrical compressive strength.

  • PDF

Compressive and Tensile Behaviors of High Performance Hybrid Fiber Reinforced Concrete (고성능 하이브리드 섬유보강 콘크리트의 압축 및 인장 거동)

  • Kwon, Soon-Oh;Bae, Su-Ho;Lee, Hyun-Jin
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.4
    • /
    • pp.458-466
    • /
    • 2020
  • The purpose of this experimental research is to evaluate the compressive and tensile behaviors of high performance hybrid fiber reinforced concrete(HPHFRC) using amorphous steel fiber(ASF) and polyamide fiber(PAF). For this purpose, the HPHFRCs using ASF and PAF were made according to their total volume fraction of 1.0% for target compressive strength of 40MPa and 60MPa, respectively. And then the compressive and tensile behaviors such as the compressive strength, compressive toughness, direct tensile strength, and stress-strain characteristics under compressive and tensile tests were estimated. It was observed from the test results that the compressive strength of HPHFRC was slightly decreased than that of plain concrete, but the compressive toughness, compressive toughness ratio, and direct tensile strength of HPHFRC increased significantly. Also, it was revealed that the plain concrete showed brittle fracture after the maximum stress from the stress-strain curves, but HPHFRC showed strain softening.

Fracture Behaviors of Alumina Tubes under Combined Tension/Torsion (알루미나 튜브의 인장/비틀림 조합하중하의 파괴거동)

  • 김기태;서정;조윤호
    • Journal of the Korean Ceramic Society
    • /
    • v.28 no.1
    • /
    • pp.19-19
    • /
    • 1991
  • Fracture of Al2O3 tubes for different loading path under combined tension/torsion was investigated. Macroscopic directions of crack propagation agreed well with the maximum principal stress criterion, independent of the loading path. However, fracture strength from the proportional loading test(τ/σ= constant) showed either strengthening or weakening compared to that from uniaxial tension, depending on the ratio τ/σ. The Weibull theory was capable to predict the strengthening of fracture strength in pure torsion, but not the weakening in the proportional loading condition. The strengthening or weakening of fracture strength in the proportional loading condition was explained by the effect of shear stresses in the plane of randomly oriented microdefects. Finally, a new empirical fracture criterion was proposed. This criterion is based on a mixed mode fracture criterion and experimental data for fracture of Al2O3 tubes under combined tension/torsion. The proposed fracture criterion agreed well with experimental data for both macroscopic directions of crack propagation and fracture strengths.

Study on the Tensile Strength Characteristics of CFRP under the High Temperature Condition (고온 환경하에서의 CFRP의 인장강도특성에 관한 연구)

  • Park Jae-Beom;Hwang Tae-Kyung;Kim Hyung-Geun;Doh Young-Dae
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.86-89
    • /
    • 2006
  • In this research, the decrease of the tensile strength in CFRP was investigated by experimental and analytical methods. We focused on the role of the interface between the reinforcing fiber and the epoxy resin matrix. The tensile and the interface strengths in CFRF were evaluated using the strand and the short beam specimens. Curtin's model which correlate the mechanical strength of the interface to the tensile strength was introduced for analytical study. The experimental and the analytical results showed good coincidence and we found that the interface strength is the key factor which governs the CFRP's tensile strength.

  • PDF

A Study on Tensile Characteristics of AISI 304 Stainless Steel under Room and Elevated Temperatures (AISI 304강의 상온/고온 인장특성에 관한 연구)

  • Park, Sung-Ho;Park, No-Seok;Kim, Jae-Hoon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.5
    • /
    • pp.35-42
    • /
    • 2008
  • This study describes the tensile test results of AISI type 304 under room and elevated temperatures. The tensile tests for AISI type 304, which is widely used for airframe structural applications, are performed according to ASTM standard. Normal probability plot was used to evaluate A and B Basis value for tensile strengths. Ramberg-Osgood parameter assuming an exponential relationship between stress and small plastic strain was obtained by least square estimate for test data. After room and elevated temperature tensile tests the surface of fractured specimens was observed by SEM images and EDX.