• 제목/요약/키워드: 인발 하중

검색결과 198건 처리시간 0.025초

사질토지반에서 수평인발하중을 받는 석션말뚝에 관한 연구 (A Study on Behavior of Horizontal Pull-out Loaded suction pile in Sands)

  • 김진복;박종운;진홍민;권오균
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.1120-1131
    • /
    • 2010
  • In this thesis the model tests were performed to the horizontal pull-out characteristics of a suction pile subjected to a pull in sands. For this model tests, soil conditions ($D_r$=65), three pile diameters (D=100, 150, 200mm) and five loading points (h/L=0, 0.25, 0.5, 0.75, 1) were changed. And the experimental results were also compared with those by the theoretical methods. The results by the experimental and theoretical analysis are as follows. The ultimate horizontal pull-out resistance by the model test increased as the loading point (h/L) moved downwards from the pile top, and the maximum value reached at the h/L=0.75. The theoretical ultimate horizontal pull-out resistance by Broms(1964) and Hong(1984) agreed well with that by the model test at h/L=0 and 0.25, but their results overestimated the experimental result at lower part of pile and the differences between the theoretical and experimental results were of great. While the horizontal loading applied at the upper part of pile, the pile moved to the horizontal direction with rotating clockwise. As the loading point moved downwards from the pile top, the rotating angle of pile was smaller.

  • PDF

타격식 앵커를 이용한 하이브리드 섬유보강재의 보강특성 (Reinforcing Characteristics of Hybrid Fiber Composite Fixed with Impact Anchor)

  • 하상수;최동욱;이진용;김동완
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.453-456
    • /
    • 2008
  • 섬유보강재는 부식에 대한 저항성이 높고, 고강도이며, 또한 강도에 대한 중량비(섬유보강재의 중량은 보강철근의 약 1/4정도)가 매우 낮아서 구조물 및 내하력이 저하된 콘크리트구조물의 보강에 따른 추가적인 중량의 증가 없이 보강을 할 수 있는 장점을 가지고 있다. 그러나 섬유보강재는 하중을 가하면, 최대 응력점까지 응력이 선형적으로 증가하다가 파괴되는 취성적 성질을 가지고 있다. 이러한 단점을 보완하기 위해 여러 섬유를 혼합하여 하이브리드화된 섬유보강재를 개발하였다. 개발된 하이브리드 섬유보강재는 유리섬유와 탄소섬유를 혼합하여 바 형태로 제작했으며, 유리섬유에 대한 탄소섬유의 체적비는 약 9 : 1로 구성이 된다. 하이브리드 섬유보강재를 타격식 앵커를 사용하여 시험체를 보수한 다음 인발 및 휨 시험을 실시하여 정착앵커의 수에 대한 시험체의 거동을 분석하였다. 본 연구에서는 타격식 앵커를 이용한 하이브리드 섬유보강재로 보강된 구조물의 보강특성을 알아보는데 목적이 있다.

  • PDF

신축이음장치에서 나사 풀림을 방지하기 위한 앵커시스템 (Anchor system in order not to Unscrew of Expansion Joint for Bridge)

  • 하상수;최동욱;이진용
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.793-796
    • /
    • 2008
  • 교량 신축이음장치의 파손 유형은 주로 후타재(무수축 모르타르)와 관련된 부분에서 많이 발생된다. 또 다른 문제는 중차량 통과에 따른 충격과 진동하중으로 인해서 신축이음장치를 후타재에 고정하기 위해서 사용하는 앵커 풀림 현상이다. 본 연구에서는 무수축 모르타르의 파괴에 따른 신축이음 장치의 파손을 방지하기 위해 탄성콘크리트를 개발하였다. 개발된 탄성콘크리트와 현재 주로 사용하고 있는 무수축 모르타르의 인발성능을 비교하였다. 또한, 후타재와 신축이음장치를 일체화하여 후타재의 파손을 방지하고 신축이음장치를 쉽게 교체할 수 있는 앵커 시스템을 개발하였다.

  • PDF

원자력 증기발생기 결함 세관 보수용 폭발 Plugging에 관한 연구 (A Study on the Explosive Plugging of A Repair for Defective Tube/Tubeplate on the Nuclear Steam Generator)

  • 이병일;심상한;강정윤;이상래
    • 화약ㆍ발파
    • /
    • 제17권4호
    • /
    • pp.18-31
    • /
    • 1999
  • The explosive forming has been used for many year to expand tubes into tubesheets. this process has demonstrated ability to direct carefully the energy of an explosive to expand tubes into tubesheet holes without damaging the tubesheet and without causing the excessive cold work at the tube I.D. that is normally associated with mechanical expansion. The success of explosive tube expansion provided the background for the development of the explosive tube plug. The main results are as follows : (1) The optimum explosives and explosive qualities are PETN, RDX, HMS and about 18~31gr/ft of explosive plugging in nuclear steam generator. (2) Explosive plugging's thickness is 0.9~1.8mm. If groove of 0.4 mm formed in plug outside, For the hydraulic leakage is go up, explosive plugging of formed groove are applicate tube and tubrplate. (3) Sheath is designed on the polyethylene of low density, In thermal impact test of the $430^\circ{C}$, hydraulic leakage is $300kg/cm^2$. (4) About 10~60mm oxide inclusions are existed on the space of explosive plug and tube protect to the leakage.

  • PDF

중공단면 복합소재 교량 바닥판의 시험을 통한 구조적 특성 분석 (Experimental Study on the Composite Bridge Deck of Hollow Section)

  • 이성우;김병석;홍기증
    • 한국전산구조공학회논문집
    • /
    • 제19권4호
    • /
    • pp.325-335
    • /
    • 2006
  • 본 논문에서는 설계와 해석을 거쳐 인발성형으로 제작된 중공단면 복합소재 교량 바닥판에 대해 휨 성능시험, 바닥판-거더 연결부시험, 바닥판-방호벽 연결부시험 등을 통해 구조적 특성을 분석하였다. 휨시험체에 지간 중앙에 변위계와 상 하부판의 주요부에 변형률계를 부착하여 파괴하중 재하시까지 거동을 계측하고 그 결과를 분석하였다. 휨시험체에 대한 유한요소해석도 실시하여 시험결과와 비교분석하였으며, 휨에 대한 극한 내하력을 추정하였다. 또한, 시범시공된 복합소재 바닥판 플레이트 거더 교량에 대한 현장 재하시험결과와 현장적용사례를 기술하였다.

사질토지반에서 인발하중을 받는 석션말뚝에 관한 연구 (A Study on Behavior of Pull-out Loaded Suction Pile in Sands)

  • 김진복;박종운;진홍민;권오균
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.944-955
    • /
    • 2009
  • In this thesis the model tests were performed to the pull-out characteristics of a suction pile subjected to a pull-out in sands. For this model tests, three different soil conditions ($D_r$=45, 65, 82%), three pile diameters (D=100, 150, 200mm) and three pile lengths (L=100, 150, 200mm), were changed. And the experimental results were also compared with those by the theoretical methods. The results by the experimental and theoretical analysis are as follows. The ultimate pull-out resistances increased as the relative density of sands, pile diameter, length and the ratio of pile length to diameter increased. The ultimate pull-out resistance by Meyerhof method(1973) overestimated that by the model test, but the results using the soil-pile friction angle suggested by Aas(1966) in the Meyerhof(1973) method were in good agreement with the experimental results.

  • PDF

하중 방향(압축-인발)과 말뚝 직경이 말뚝의 지지력에 미치는 영향에 관한 연구 -실내모형시험- (The Effect of Load Direction and Pile Size on the Pile Bearing Capacity : Model Pile Tests)

  • 이인모;백세환
    • 한국지반공학회지:지반
    • /
    • 제8권3호
    • /
    • pp.13-22
    • /
    • 1992
  • Model pile tests using calibration chamber are performed in !his paper in order to clarify the effect of the fundamental differences between the newly developed SPLT(Simple Pile Loading Test)and the conventional pile loading test on the pile bearing capacity. They are : (1) the direction of the applied load to mobilize the skin friction ; and (2) the use of reduced sifted sliding core. The conclusions obtained from the model pile tests are as follows : (1) The skin friction in tension loading is found to be somewhat smaller than that in compression loading. The average ration is 0.73 with the coefficient of variation (COV) of 0.18. (2) The ratio of the tip resistance rosin연 the reduced sized sliding core to that using the whole shoe shows wide scattering ; its average is 0.99 and the COV is 0.28. The aver - age of 0.99 means that there is no considerable difference in the tip resistance whether the reduced sized sliding core or the whole shoe is used, on condition that penetration depth ratio is larger than 4 : if the boundary effect of the chamber test is considered, the resistance of the whole shoe might be even larger.

  • PDF

수치해석을 이용한 육각 낙석방지망의 성능 평가 (Performance Estimation of Hexagonal Rockfall Protection Net by Numerical Analysis)

  • 오세욱;박수범;권영철
    • 한국지반환경공학회 논문집
    • /
    • 제15권11호
    • /
    • pp.53-59
    • /
    • 2014
  • 낙석방지망에 대한 기존 연구 결과에 의하면 종래의 낙석방지망에서 발생되는 대표적인 문제점으로 이완성이 없는 횡방향 와이어로프에 의해 발생되는 낙석 중량의 누적현상, 지반과 낙석방지망의 결합지점 부족으로 인한 인발지지력 부족, 낙석의 과도한 충격으로 인한 철망의 빈번한 파손, 낙석방지망의 유지관리 시 철망의 재사용의 어려움 등이 보고되고 있다. 선행 연구를 통해 실내에서의 인장력과 현장실험이 실시되어 새로운 낙석방지망의 효과를 검증한 바 있다. 선행연구에 이어 본 연구에서는 기존의 사각낙석방지망과 비교하여 충격 완화형 육각 낙석방지망의 전체적인 구조적 안정성과 성능을 수치해석적 방법을 통해 점검하는 것에 그 목적이 있으며, 이를 충분히 검토하고 결과를 얻을 수 있도록 수치해석 프로그램이 설정되었다. 수치해석 결과를 종합해볼 때 동일한 단일 셀 간격 뿐만 아니라 동일한 면적비로 비교하더라도 육각 낙석방지망이 사각 낙석방지망에 비해 하중분배 효과가 우수한 것으로 나타났으며, 육각 낙석방지망은 낙석하중이 작용할 경우 이를 효율적으로 분산시킴으로써 과도한 하중 집중이 발생하는 것을 피할 수 있어 장기적인 안정성 확보에 유리할 것으로 판단된다.

소규모 철골조건축물을 위한 약축방향 노출형 주각부의 내진성능 향상 (Seismic Performance Enhancement of Exposed Column-base Plate Weak-axis Connections for Small-Sized Steel Buildings)

  • 유영찬
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권5호
    • /
    • pp.1-12
    • /
    • 2019
  • 소규모 철골조건축물의 접합상세에 대한 현장조사에 따르면 지진하중에 의한 횡적 안전성 및 안정성 확보가 불충분할 것으로 예상되는 임의 접합상세가 현장에서 적용되는 것으로 조사되었다. 이에 따라 본 연구에서는 소규모 강구조건축물의 노출형 주각부 약축 연결부의 반복이력 실험을 통해 문제점을 분석하고, 이를 바탕으로 내진성능을 향상시킬 수 있는 접합상세의 개발을 위해 일련의 실험연구를 수행하였다. 본 실험결과에 의하면, 국내에서 흔히 사용되는 노출형 주각부 약축방향 접합부의 이력거동은 앵커볼트가 콘크리트로부터 점진적으로 인발됨에 따라 베이스플레이트와 앵커볼트사이에 이격거리가 누적되어 하중역전구간에서 "Rocking" 현상이 발생되어 내진성능이 매우 낮은 것으로 조사되었다. 이와 같은 문제점을 개선하기 위하하여 앵커볼트의 콘크리트에 대한 부착 유/무와 개수 및 배열형태 등을 변수로 한 성능개선 실험체에 대한 일련의 반복 이력 실험을 수행하였으며, 최종적으로 소규모철골조 건축물의 노출형 주각부에 고강도 전산볼트형 앵커볼트를 8개로 3열로 배치하는 상세의 적용을 통하여 하중지지능력과 에너지분산능력 측면에서 내진성능이 크게 개선된 것을 확인할 수 있었다.

격자형 CFRP 보강재의 격자간격에 따른 콘크리트 부착거동에 대한 실험적 연구 (An Experimental Study on Concrete Bond Behavior According to Grid Spacing of CFRP Grid Reinforcement)

  • 노치훈;장낙섭;오홍섭
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권6호
    • /
    • pp.73-81
    • /
    • 2022
  • 최근 구조물의 사용연한이 증가함에 따라 다양한 요인에 의해 철근이 부식되어 구조물의 내하력이 감소하는 문제들이 발생하고 있다. 이를 해결하기 위하여 내식성, 경량성, 고인장강도를 갖는 FRP 보강근의 부착특성에 대한 연구가 활발히 진행중이나, 콘크리트에 매립된 격자형 CFRP 보강재의 부착특성에 관한 연구는 미흡한 실정이다. 따라서 격자형 CFRP 보강재를 철근의 대체재로 사용하고 사용성 측면에서 부착특성을 평가하기 위해, 격자형 CFRP 보강재의 종방향 부착길이와 횡방향 격자길이를 변수로 하여 직접인발시험을 수행하였다. 이를 통해 격자형 CFRP 보강재의 부착하중-슬립 곡선을 도출하였으며, 부착거동을 분석하였다. 총 부착하중 식은 종방향 부착길이의 부착력과 횡방향 격자의 전단력의 합으로 제안하였으며, 부착하중-슬립곡선의 면적을 전체 일로 표현하여 슬립량에 대한 에너지 소산량의 변화를 분석하여 횡방향 격자가 부착력에 미치는 영향에 대하여 검토하였다.