• Title/Summary/Keyword: 인명대피

Search Result 178, Processing Time 0.034 seconds

A Study on the Conceptual Design of Quay Process Monitoring System (안벽공정 모니터링 시스템의 개념 설계에 관한 연구)

  • Kim, Ho-Kyeong;Ko, Dae-Eun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.426-431
    • /
    • 2016
  • In quay processes in shipyards, it is difficult to manage workers and to maintain secure working environments because at least 1,000 people can occupy the quay at the same time. In this study, a system was designed to monitor the environment and processes of quay operation. In order to lower initial investments and the costs of maintenance and operation, the entire system consists of six connected components. Considering the communication environment of the shipyard site, Wi-Fi and the LoRa communication protocol were selected for the system. The feasibility of the communication protocols was verified by data transmission tests in the field. The designed system can provide real-time information about employees working in the quay area, the safety status of moored ships on the quay, and step-by-step alarms in dangerous situations based on the detected information. The system is expected to prevent or greatly reduce safety hazards.

Real-Time Flood Forecasting Using Neuro-Fuzzy in Medium and Small Streams (Neuro-Fuzzy를 이용한 중.소하천 실시간 홍수예측)

  • Choi, Seung-Yong;Han, Kun-Yeun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.262-262
    • /
    • 2011
  • 최근 들어 지구환경 변화에 따른 이상기후의 영향으로 태풍 및 집중호우로 인한 하천범람 등 홍수재해에 의한 인명과 재산의 피해가 급증하고 있다. 특히 한반도 지역에서는 집중호우와 태풍과 같은 이상강우로 인한 홍수피해의 발생이 매년 나타나고 있으며 홍수피해의 빈도와 강도는 증가하고 있는 실정이다. 이러한 상황에서 극심한 기상이변으로 인하여 발생되는 이상홍수의 예측에 관한 사항은 치수 이수는 물론 친수관점에서 볼 때 하천관리의 측면에서 매우 중요한 관심사로 부각되고 있다. 특히 홍수예측은 주민의 대피 및 통제, 시설물의 보호 등을 위해 충분한 선행시간을 확보할 수 있는 실시간적 관점에서의 홍수예측 및 관리가 중요하다. 기존의 수문학적 강우-유출 모형은 비선형성이 강하고 유역의 지형학적 인자와 기후학적 인자의 영향을 포함하기 때문에 정확한 예측이 어렵고 유출량을 계산하기 위한 유역추적, 저수지추적 및 하도추적의 각 추적과정에서 크고 작은 오차들이 발생하고 그것들이 누적되어 유출 모형의 해석 결과에는 많은 오차들이 포함되어 있다는 문제점이 있다. 또한 주로 유역 면적이 크고 홍수의 도달시간이 긴 대하천의 홍수예측에는 기존의 강우-유출 모형이 적당한 방법임에도 불구하고 유역면적이 작은 중소하천에 적용됨으로써 많은 불확실성을 포함하고 있으며 충분한 선행시간을 확보하지 못하는 문제점을 가지고 있다. 따라서 본 연구에서는 중소하천에서의 기존의 홍수예경보가 가지고 있는 문제점을 해결하기 위해 실시간 수위측정 자료 및 강우자료를 이용한 간단한 입력자료 만으로도 홍수예측이 가능한 뉴로-퍼지(Neuro-Fuzzy) 모형을 구축하여 충분한 선행시간을 확보함으로써 중소하천에서 의 실시간 홍수예측이 가능한 시스템을 구성하여 실시간으로 구동되는 효율적인 홍수예경보 시스템을 개발하고자 하였다. 임진강 유역을 대상으로 기존의 강우-유출 모형이 요구하는 유역의 물리적, 지형 자료 및 매개변수와 같은 광범위한 양의 자료를 배제하고, 유역의 강우 자료와 수위자료만으로 유역의 중요지점에 대한 홍수위 및 홍수량을 예측할 수 있는 뉴로-퍼지 모형을 구축하고 대상 유역에 적용하여 실측치와 비교 검증하였다.

  • PDF

The Verification of Two Dimensional Model Applicability for Establishing EAP from Dam Failure (댐 붕괴에 따른 EAP 수립을 위한 2차원 모형의 적용성 검증)

  • Park, Jun Hyung;Lee, Jae Yeong;Keum, Ho Jun;Han, Kun Yeun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.66-66
    • /
    • 2016
  • 태풍 및 집중호우로 인해 댐과 저수지 등의 붕괴위험이 증가되고 있으며, 실제로 붕괴가 일어나 크고 작은 피해사례가 증가하고 있다. 담수의 목적을 가진 댐과 저수지가 붕괴될 경우 다른 자연재해에 비해 인명 및 재산에 대한 피해가 막대하다. 따라서 국가 및 각 지자체에서 관리하고 있는 댐과 저수지는 안전성 평가 및 비상대처계획 등을 수립하여 만약의 상황에 대해 대비를 하고 있다. 특히 비상대처계획의 경우 댐 붕괴시 상황을 예상하여 홍수파의 전파와 대피로 등을 설정하는 것으로 댐 붕괴상황시 매우 중요한 역할을 한다. 하지만 지금까지의 비상대처계획 수립시 하류부 홍수파 해석은 1차원 모형을 활용하여 범람지역의 산정 및 홍수파에 대한 정보를 획득하였다. 1차원 모형의 경우 빠른 계산시간과 해석을 위한 절차가 간단한 장점이 있으나 건물 및 제내지의 정확한 지형을 반영하지 못하며, 제내지에서의 홍수파 전파양상 등을 나타내지 못하는 단점이 있다. 이에 본 연구에서는 정확한 지형의 반영과 제내지에서의 상세한 홍수파 해석이 가능한 2차원 모형을 이용하여 비상대처계획 수립시 적용성을 검토해보았다. 실제 붕괴사례인 경주 산대저수지 붕괴를 통해 2차원 모형의 정확성을 검증하였으며, 이를 국내 A저수지에 적용하여 비상대처계획도를 작성하였다. 대상저수지의 경우 댐 직하류부에 주거지역 및 홍수파가 넓게 퍼질 수 있는 지형을 가지고 있어 2차원 모형의 장점을 잘 활용할 수 있다고 판단하여 대상 저수지로 선정하였다. 1차원 모형인 DAMBRK 모형과 2차원 모형인 FLO-2D 모형을 사용하여 1 2차원 모형의 댐 붕괴홍수파 해석 결과를 비교하고, 그 결과를 이용한 비상대처계획도를 작성을 하여 비교하였다. 그 결과 기존에 활용되던 비상대처계획도의 단점을 보완하여 정확한 침수범위 및 홍수파 전파양상을 나타낼 수 있는 새로운 비상대처계획도 작성할 수 있었다. 따라서 본 연구를 통해 정확한 지형의 반영이 필요하거나 댐 및 저수지 하류부에 도심지가 위치한 경우 제내지에서의 상세한 홍수파 정보를 제공할 수 있는 비상대처계획도 작성에 기여할 수 있을 것으로 판단된다.

  • PDF

A Comparative Study on 1D and 2D Hydraulic Analysis Model for Emergency Action Plan (비상대처계획 활용을 위한 1차원 및 2차원 수리해석모형의 비교 검토 연구)

  • Kim, Tae Hyung;Kim, Ji Sung;Lee, Young Gon;Kwak, Jae Won;Choi, Kyu Hyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.350-350
    • /
    • 2016
  • 댐 및 저수지 시설물의 붕괴에 대비하기 위한 댐 붕괴 비상대처계획 수립은 대규모 인명 또는 재산의 피해를 예방하기 위한 중요한 비구조적 대책중의 하나이다. 특히 대규모 댐붕괴로 인한 재난 발생시 국민의 생명과 재산 피해를 최소화하기 위해 댐 시설물의 관리주체 및 유관기관은 발생가능한 비상상황을 미리 예측하고, 대응조치를 신속하고 효율적으로 집행해야 한다. 댐 붕괴 비상대처계획 수립을 위해 가장 중요한 사항은 댐 붕괴 위험도를 파악하고, 발생가능한 여러 시나리오에 따른 댐 하류부의 피해정도를 예측하는 일이다. 댐 붕괴 비상대처계획 시 작성되는 홍수범람 지도는 댐 붕괴사고가 발생했을 때 주민대피계획 및 위험지역 교통통제, 응급의료활동 및 생필품 공급 등, 비상대처계획 수립을 위한 가장 기본적인 자료가 된다. 현재 우리나라는 댐 붕괴 비상대처계획 수립을 위해 1차원 또는 2차원 수리해석 모형을 이용하여 홍수범람지도를 작성하고 있다. 전체적인 비상대처 계획도 작성을 위해 댐 붕괴로 인한 홍수파 해석이 가능한 1차원 수리해석 모형을 주로 이용하지만, 홍수파가 전파되는 하류부의 지형학적 특성상 2차원 해석이 필요한 지역에 대해 2차원 수리해석 모형을 이용하여 추가의 검토가 이루어지고 있다. 본 연구에서는 비상대처계획시 동시에 활용되는 1차원 수리해석 모형과 2차원 수리해석 모형의 특성을 각각 분석하고, 시범지역의 가상 댐 붕괴사상에 대해 적용함으로써, 각 모형의 장단점과 적용성에 대한 비교 검토 연구를 수행하였다. 낙동강유역내 위치한 다목적댐에 대해 1차원 및 2차원 붕괴모의를 실시하였으며, 여러 시나리오에 대해 1차원 모형과 2차원 모형 각각에 대해 동일하게 적용함으로써 두 모형의 모의 결과에 대한 비교 분석을 실시하였다. 본 연구를 통해 비상 대처계획 수립을 위한 홍수범람지도 작성 시 1차원 모형과 2차원 모형의 장점을 각각 반영할 수 있도록 홍수범람지도를 효율적이고 정확하게 작성하기 위한 제언을 제시하고자 하였다.

  • PDF

Implementation of CNN-based water level prediction model for river flood prediction (하천 홍수 예측을 위한 CNN 기반의 수위 예측 모델 구현)

  • Cho, Minwoo;Kim, Sujin;Jung, Hoekyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.11
    • /
    • pp.1471-1476
    • /
    • 2021
  • Flood damage can cause floods or tsunamis, which can result in enormous loss of life and property. In this regard, damage can be reduced by making a quick evacuation decision through flood prediction, and many studies are underway in this field to predict floods using time series data. In this paper, we propose a CNN-based time series prediction model. A CNN-based water level prediction model was implemented using the river level and precipitation, and the performance was confirmed by comparing it with the LSTM and GRU models, which are often used for time series prediction. In addition, by checking the performance difference according to the size of the input data, it was possible to find the points to be supplemented, and it was confirmed that better performance than LSTM and GRU could be obtained. Through this, it is thought that it can be utilized as an initial study for flood prediction.

Using Flood Inundation Map of Yeongsan and Seomjin River Basin for Coping with Disaster (영산·섬진강 권역 홍수위험지도의 재난대응 활용)

  • Kwon, Minsung;Jung, Chung Gil;Lee, Joonho;Gang, Donghoon;Choi, Kyuhyun;Kim, Kyuho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.497-497
    • /
    • 2022
  • 홍수위험지도는 홍수발생시 예방되는 침수범위와 침수깊이를 나타내는 지도로 2009년 영산강수계(237.53 km), 2016년에 섬진강수계(251.06 km) 국가하천의 홍수위험지도가 제작되었고, 2021년 영산·섬진강권역 지방하천(4521.31 km) 홍수위험지도가 제작됨으로써 영산·섬진강권역 홍수위험지도 제작이 모두 완료되었다. 홍수위험지도 제작은 GIS 범람해석, 1차원 및 2차원 수치모형으로 구분할 수 있따. GIS 범람해석은 제내지의 지형 수치표고모델(DEM) 등을 활용하여 지형자료를 구축하고, 측점별 홍수위를 이용한 홍수위 DEM을 작성한 후 각 DEM의 고도차를 계산하여 홍수범람구역을 도시하는 방법이다. 도심지 또는 주거지를 관류하는 하천에 대해서는 제방의 편안 파제를 가정하여 FLUMEN모형을 이용한 2차원 범람분석 또는 HEC-RAS모형을 이용한 1차원 범람분석 방법 적용한다. 위와 같은 분석 방법으로 도출된 침수 결과는 제방 월류 및 제방 유실 등의 극한 상황을 가정한 것으로, 2020년 섬진강 대홍수 홍수피해 침수구역과 홍수위험지도의 침수구역의 겨의 일치하는 것으로 나타났다. 즉 하천홍수로 발생할 수 있는 피해의 규모를 예측할 수 있으며, 이러한 예측정보는 방재계획 수립 및 홍수대응에 활용도가 높을 것이다. 홍수위험지도는 홍수위험지도정보시스템(www.floodmap.go.kr)에서 누구나 확인이 가능하며, 지자체 방재담당자는 회원가입을 통해 홍수위험지도 전산파일 및 보고서 등을 받을 수 있다. 방재담당자는 홍수위험지도의 침수구역을 바탕으로 대피계획을 수립하고, 집중호우로 인한 하천수위 상승 시 홍수위험지도의 침수구역을 중심으로 방재활동을 하여 인명피해를 최소화할 수 있을 것이다.

  • PDF

RSET Analysis of Factory Workbench Layout Configuration (공장 작업대 배치 형태에 따른 RSET 분석)

  • WOO-GI JANG;DEOK-JIN JANG;HA-SUNG KONG
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.479-485
    • /
    • 2023
  • Although fire incidents occur frequently in factory buildings, the focus has primarily been on property damage rather than human casualties. In this study, we conducted an analysis of RSET(Required Safe Egress Time) variation by examining the relocation of workbenchs using evacuation simulations. The results demonstrated that a simple change in workbench placement led to different RSET and variations in the feasibility of evacuation. Specifically, arranging workbenchs in a vertical configuration reduced travel time for workers and minimized total evacuation time. The hybrid layout of "vertical-horizontal" exhibited the shortest RSET, while the "horizontal-vertical" configuration resulted in the longest RSET. These research findings are significant as they provide practical alternatives to decrease RSET in small-scale factories where additional investments beyond essential safety equipment may pose challenges due to budget constraints. However, it is important to note that this study solely focused on comparing RSET while controlling for all other factors, without considering real-life fire simulations. Therefore, further research is necessary to integrate fire simulations and conduct comprehensive assessments of evacuation safety.

Installation Standards of Urban Deep Road Tunnel Fire Safety Facilities (도심부 대심도 터널의 방재시설 설치 기준에 관한 연구(부산 승학터널 사례를 중심으로))

  • Lee, Soobeom;Kim, JeongHyun;Kim, Jungsik;Kim, Dohoon;Lim, Joonbum
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.727-736
    • /
    • 2021
  • Road tunnel lengths are increasing. Some 1,300 tunnels with 1,102 km in length had been increased till 2019 from 2010. There are 64 tunnels over 3,000 m in length, with their total length adding up to 276.7 km. Safety facilities in the event of a tunnel fire are critical so as to prevent large-scale casualties. Standards for installing disaster prevention facilities are being proposed based on the guidelines of the Ministry of Land, Infrastructure and Transport, but they may be limited to deep underground tunnels. This study was undertaken to provide guidelines for the spacing of evacuation connection passages and the widths of evacuation connection doors. Evacuation with various spacing and widths was simulated in regards to evacuation time, which is the measure of safety, using the evacuation analysis simulation software EXODUS Ver.6.3 and the fire/smoke analysis software SMARTFIRE Ver.4.1. Evacuation connection gates with widths of 0.9 m and 1.2 m, and spacings of 150 m to 250 m, were set to every 20 m. In addition, longitudinal slopes of 6 % and 0 % were considered. It was determined to be safe when the evacuation completion time was shorter than the delay diffusion time. According to the simulation results, all occupants could complete evacuation before smoke spread regardless of the width of the evacuation connection door when the longitudinal slope was 6 % and the interval of evacuation connection passage was 150 m. When the evacuation connection passage spacing was 200 m and the evacuation connection gate width was 1.2 m, all occupants could evacuate when the longitudinal slope was 0 %. Due to difference in evacuation speed according to the longitudinal slope, the evacuation time with a 6 % slope was 114 seconds shorter (with the 190 m connection passage) than with a 0 % slope. A shorter spacing of evacuation connection passages may reduce the evacuation time, but this is difficult to implement in practice because of economic and structural limitations. If the width of the evacuation junction is 1.2 m, occupants could evacuate faster than with a 0.9 m width. When the width of a connection door is 1.2 m with appropriate connection passage spacing, it might provide a means to increase economic efficiency and resolve structural limitations while securing evacuation safety.

A Study on the Necessity of Introducing Evacuation Instrument in High-rise Buildings - Focusing on Elevator Type Evacuation Instrument - (고층건축물의 피난기구 도입 필요성에 관한 연구 - 승강식피난기를 중심으로 -)

  • Choi, Kyu-Chool;Ra, Pan-Ju;Seul, Yeong-Mi
    • Fire Science and Engineering
    • /
    • v.28 no.3
    • /
    • pp.10-19
    • /
    • 2014
  • The fast evacuation from fire floors to evacuation floors in high-rise building fires can minimize the human damage. In this study, an evacuation instrument, which are applicable to the high-rise buildings of adaptable escape mechanisms by the current NFSC 301 (national fire safety code 301), were selected to analyze the applicability in the high-rise buildings over 11th floor through the site adaptability test. The results of the site test were as follows. The elevator type evacuation instrument of new concept developed as a new technology by compensating the defect of evacuation instrument limiting in the high-rise buildings over 11th floor had completed the stability test and the performance certification test in fire stations, which there were no problems in the introduction of the elevator type evacuation instrument as an escape mechanism in the high-rise buildings. The elevator type evacuation instrument using escapers' weight without using electric power was an escape mechanism that many people could evacuate in a short period of time when a fire broke out in the high-rise buildings. In particular, The elevator type evacuation instrument operated by nonpower had the adaptability as a customized escape mechanism considering user characteristics in the buildings for the disabled or patients with an advanced disease.

Standardization of Underground Shopping Center Address System for the Three-Dimensional GIS-based Emergency Management (3차원 GIS기반의 소방방재를 위한 지하상가 주소체계 표준화)

  • Ha, Byeong Po;Kang, In Joon;Hong, Soon Heon;Park, Dong Hyun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.22 no.4
    • /
    • pp.63-69
    • /
    • 2014
  • Due to population growth and urban development in construction technology has expanded living space, underground construction as public transport as has been extended to the ground and underground urban traffic congestion increases. This underpass Stations sphere of influence this development was the center of the living space, space-time became a cultural space. However underpass ground space and time and space are enormous difficulties in contrast visibility due to smoke when light levels are low fire occurs, momentary loss of judgment errors due to a sense of orientation, rapid diffusion and ambient oxygen deficiency due to acquisition limitations, such as the Open resulting in property damage and personal injury. The purpose of this study is to analyze the existing system with respect to the address of the underground shopping center and system for presenting an address to the underground shopping mall in the basement of the straight and circular in connection with the street name address. Also can be known only to evacuate their citizens to address the position in the event of a fire inside the basement through the underground shopping mall address standardization system, the fire department only address exact location is being judged will be identified.