Search Result 22, Processing Time 0.021 seconds

A Meta-Analysis of the Ventilator Circuit Change Period on Ventilator-Associated Pneumonia (인공호흡기 회로 교환주기가 인공호흡기 관련 폐렴에 미치는 영향에 관한 메타 분석)

  • Song, Ju Hyun;Kim, Kyung Hee
    • Journal of Korean Clinical Nursing Research
    • /
    • v.16 no.3
    • /
    • pp.111-121
    • /
    • 2010
  • Purpose: This meta-analysis was aimed to investigate the evidence of proper period of the ventilator circuit change using existing research. Methods: For this study, 14 published studies between 1995 and 2010 were tested by Macaskill, Funnel Plot, the Odds Ratio of DerSimonian and Laird, Fisher and Liptak analysis. Results: There were no publication bias found in the subjects. The results of the meta-analysis demonstrated no statistically significant differences were observed in neither the Odds Ratio (OR=1.18, 95% CI=0.94-1.47) of the frequency of ventilator-associated pneumonia and the mortality based on the period of the ventilator circuit change (Fisher p=.332, Liptak p=.498), nor the ventilation duration of ventilator (Fisher p=.843, Liptak p=.506), and the hospital length of stay (Fisher p=.254, Liptak p=.480). Conclusion: In order to present more concrete guidelines on the period of the ventilator circuit change, further research is warranted to thoroughly control confounding variables which related to the periods of the ventilator circuit change.

Clinical Study of Children Using Home Mechanical Ventilation (가정용 인공 호흡기를 사용하는 소아의 임상적 고찰)

  • Ahn, Young Joon;Lee, Seung Hyeon;Kim, Hyo-Bin;Park, Seong Jong;Ko, Tae Sung;Hong, Soo Jong
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.4
    • /
    • pp.401-405
    • /
    • 2005
  • Purpose : The use of mechanically-assisted ventilators at home reduces morbidity and improves the quality of life in children with chronic respiratory failure. But in Korea there is no clinical data of children with home mechanical ventilation. We investigated ventilator types, duration, the causes of failure or death, and the cost needed for care. Methods : We retrospectively analyzed the medical records of 21 children who were admitted and who applied for home mechanical ventilation at the Pediatric Intensive Care Unit in Asan Medical Center. Phone interviews took place after discharge. and interviewed by phone after discharge. Results : The median age was 31 months; the median duration with ventilator was 25 months. Underlying diseases were 16 neuromuscular diseases, one metabolic disease and four chronic respiratory diseases. The types of ventilator were pressure and volume type(16 and five patients, respectively). The frequency of ventilation failure was once per 19 months. Weaning could be performed in three cases. Frequencies of admission after receiving ventilators were 1.7 times per year; the most common cause was pneumonia. Nine patients(43%) died; four of them died because of endotracheal tube obstruction. The costs for medical care were about 1,110,000 won per month. Conclusion : There is an increment in the numbers of individuals who need mechanical ventilation support. The most common cause of death was endotracheal tube obstruction. The most important problem for the patients was medical cost. There needs to be more interest in patients with ventilator and social welfare systems to support their families need to be prepared.

Ventilator-associated Pneumonia with Circuit Changes Every 7 Days versus Every 14 Days (회로 교환주기에 따른 인공호흡기 관련 폐렴발생률 차이)

  • Choi, Jeong-Sil;Yeon, Jeong-Haw
    • Journal of Korean Academy of Nursing
    • /
    • v.40 no.6
    • /
    • pp.799-807
    • /
    • 2010
  • Purpose: To determine whether the practice of not routinely changing ventilator circuits in patients who require prolonged mechanical ventilation is associated with ventilator-associated pneumonia (VAP). Methods: Patients were divided into two groups, ventilator circuits were routinely changed every 7 days for the control group (39) and every 14 days for the experimental group (40) over a period of 1 yr (April 1, 2009-March 31, 2010). Pediatric patients (age 17 yr or less) were not included. VAP was diagnosed by the criteria of the Centers of Disease Control and Prevention (CDC). Incidence of VAP and characteristics of infection were evaluated. Results: In the experimental group, 2 episodes of pneumonia were observed in 40 patients and 1,322 ventilator days. The rate of VAP was 1.5 per 1,000 ventilator days. There was 1 episode of pneumonia in 39 patients and 481 ventilator days for the control group. The rate of VAP was 2.1 per 1,000 ventilator days. The difference between both groups was not significant (p=.695). Conclusion: Extending ventilator circuit change interval from 7 days to 14 days does not increase the risk for VAP.

Comparison of Rehospitalization during the First Year of Life in Normal and Low Birth Weight Infants Discharged from NICU (신생아 집중치료실에서 퇴원한 정상 체중아와 저출생 체중아의 재입원에 관한 비교)

  • Min, Sae Ah;Jeon, Myung Won;Yu, Sun Hee;Lee, Oh Kyung
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.12
    • /
    • pp.1503-1511
    • /
    • 2002
  • Purpose : Although the short- and long-term outcomes of low birth weight(LBW) neonatal intensive care unit(NICU) survivors have been extensively studied, much less information is available for normal birth weight(NBW) infants(greater than 2,500 gm) who require NICU care. Methods : We retrospectively examined the neonatal hospitalizations and one year health status of 302 NBW and 131 LBW admissions to our NICU. Information on the neonatal hospitalization was obtained from a review of medical records. Postdischarge health status was collected by using telephone surveys and medical records. Results : After initial discharge, 21.2% of the NBW infants and 23% of the LBW infants required rehospitalization during the first year of life and there was no significant difference between the two groups. The reasons for rehospitalization of the NBW infants included respiratory disorders (32.1%), G-I problems(26.2%), genitourinary problems(11.9%), surgery(10.7%), cardiac problems(7.1%), and congenital/developmental problems(1.2%). For the LBW infants, the order of frequency was the same, with the percentages slightly different. Neonatal risk factors related to the rehospitalization of the NBW infants included mechanical ventilation, duration of mechanical ventilation, and congenital anomaly. But no positive significant correlation of neonatal risk factors with rehospitalization of LBW infants was found. Conclusion : Low and normal birthweight NICU survivors were rehospitalized at similar rates. The most common cause of rehospitalization was respiratory problems. Neonatal risk factors related to rehospitalization of NBW infants were mechanical ventilation, duration of mechanical ventilation, and congenital anomaly. However, no positive significant correlation of neonatal risk factors with rehospitalization of LBW infants was found. The data suggests that NBW infant survivors, as well as LBW infant NICU survivors, require close follow up.

Weaning Following a 30 Minutes Spontaneous Breathing Trial (30분 자가호흡관찰에 의한 기계적 호흡치료로부터의 이탈)

  • Shin, Jin;Koh, Young-Min;Chung, Yeon-Tae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.6
    • /
    • pp.1326-1331
    • /
    • 1997
  • Background : Weaning is the process of switching a patient from mechanical ventilator to spontaneous breathing. A number of different weaning techniques can be employed. At recent study, conventional spontaneous breathing trial was superior to other techniques, such as intermittent mandatory ventilation(IMV) or pressure support ventilation(PSV). But adequate observation time of the spontaneous breathing trial was not determined. We reported the effectiveness of weaning and extubation following a 60 minutes spontaneous breathing trial with simple oxygen supply through the endotrachial tube. In this study, we tried to shorten the spontaneous breathing time from 60 minutes to 30 minutes. If weaning success was predicted after 30 minutes spontaneous breathing, extubation was done without reconnection with ventilator. Methodes : Subjects consisted of 42 mechanically ventilated patients from August 1994 to July 1995. The weaning trial was done when the patients recovered sufficiently from respiratory failure that originally required ventilatory assistance, the patients became alert and showed stable vital sign, and arterial $O_2$ tension was adequated($PaO_2$ > 55 mmHg) with less than 40% of inspired oxygen fraction. We conducted a careful physical examination when the patients was breathing spontaneously through the endobronchial tube for 30 minutes. We terminated the trial if a patients was any of following signs of distress; cyanosis, diaphoresis, tachypnea(above 30 breaths per minute), and extreme tachycardia. Patients who had none of this features during spontaneous breathing for 30 minutes were extubated promptly. Result : 17 weaning trials of 15 patients were done in 42 mechanically ventilated patients. Successful weaning and extubation was possible in 14 trials of total 17 trials. In this 14 patients, 8 patients were extubated after 30 minutes spontaneous breathing, 3 patients were extubated after 60 minutes spontaneous breathing, and 3 patients needed over 3 hours for extubation from weaning. We found similar overall success rate compared with weaning following a 60 minutes spontaneous breathing trial. Conclusion : From the result of present study, we believe that weaning and extubation from mechanical ventilation following a 30 minutes spontaneous breathing with $O_2$ supply through the endotracheal tube is a simple and effective method.

  • PDF

A Study on the Effects of Early Surfactant Replacement and Gentle Ventilation in the Treatment of Respiratory Distress Syndrome (미숙아 호흡 곤란 증후군에서 폐 표면 활성제의 조기 투여와 연성 환기 요법의 치료 효과에 관한 연구)

  • Lee, Yong Suk;Lee, Ji Hye;Lee, Sang Geel
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.10
    • /
    • pp.1096-1101
    • /
    • 2005
  • Purpose : Recently, early surfactant replacement and tidal volume based gentle ventilation has been a fundamental treatment of respiratory distress syndrome(RDS). The aims of this study were to survey the changes in ventilator care duration and rate of complication in RDS groups. Methods : We performed a retrospective study of 255 newborn infants less than 1,500 g admitted to the neonatal intensive care unit(NICU) and discharged from January 1999 to December 2003. 141 of 255 newborn infants were RDS groups that required invasive management, such as endotracheal intubation, surfactant replacement and assisted ventilation. We analyzed epidemiologic data to study the changes in ventilator care duration and outcome of RDS groups. Results : Of 141 RDS groups, 135 were mild to moderate RDS groups and only 6 were severe RDS groups. 24(17.8%) of 135 mild to moderate RDS groups and 3(50%) of 6 severe RDS groups were antenatal no use of maternal dexamethasone. 127(90.1%) of 141 RDS groups underwent replacement of surfactant during 3 hours after birth. 121(85.9%) weaned within 48 hours. Conclusion : Our study shows a decreased frequency of severe RDS by a antenatal use of maternal dexamethasone and decreased duration of ventilator care by early surfactant replacement and gentle ventilation.

Comparison of Oral Care and Ventilator Circuit on the Reduction of Multi-drug Resistant Infections among Intensive Care Unit Patients (구강간호방법과 인공호흡기회로 종류에 따른 다제내성균 발생률 비교)

  • Shin, Eun Suk;Lee, Gyung Jin;Choi, Eun Jung;Lim, Sung Chul;Lee, Eun Sook
    • Journal of Korean Clinical Nursing Research
    • /
    • v.17 no.2
    • /
    • pp.150-162
    • /
    • 2011
  • Purpose: Multi-drug resistant (MR) infections among intensive care unit (ICU) patients with oral intubation and a ventilator are serious nosocomial infections. This study was done to compare the effects of oral care and ventilator circuit on reduction of MR infections. Methods: A total of 92 participants were recruited from an ICU at C University Hospital in G-city, Korea, assigned to one of 4 groups and evaluated: group I received oral care with sponge and reusable circuit; group II received oral care with tooth brush and reusable circuit; group III received oral care with sponge and disposable circuit; group IV received oral care with tooth brush and disposable circuit. Results: Prevalence rate of MR infections was highest in group I (47.8%), followed by group II (30.4%), group IV (19.0%), and group III (13.6%). Of the four groups, group III showed a significantly decreased MR infections (p=.035) and higher possibility of survival rate as time passes according to survival analysis (p=.019). Conclusion: Results of this study indicate that using disposable ventilator circuit significantly decreases MR infections and raises the possibility of a higher survival rate as time passes. According to this study, the use of disposable ventilator circuit is useful in prevention of MR infections.

The Effects of Tidal Volume on Minimal Occlusion Pressure of Endotracheal Tube Cuff in Patients with Same Peak Inspiratory pressure (동일한 최고 흡기압(Peak inspiratory pressure)에서 기관 내관 풍선(Endotracheal tube cuff)의 최소 밀폐압(Minimal occlusion pressure)에 대한 상시량의 영향)

  • Sohn, Jang Won;Kim, Tae Hyung;Yoon, Ho Joo;Shin, Dong Ho;Park, Sung Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.57 no.5
    • /
    • pp.434-438
    • /
    • 2004
  • Background : An excessive endotracheal cuff pressure can cause tracheal injury, and insufficient cuff pressure may not generate an effective cuff seal. The peak inspiratory pressure influences the minimal occlusion pressure of the endotracheal tube cuff. However, the relationship between the minimal occlusion pressure and the tidal volume has not been investigated. This study was conducted to estimate the relationship between the tidal volume and the minimal occlusion pressure of the cuff. Methods : Ten mechanically ventilated patients were included. The minimal occlusion pressure of the cuff was measured using a pressure gauge. The basal tidal volume was increased and decreased as much as 10% whilst maintaining the same peak inspiratory pressure. The, minimal occlusion pressures were then measured in the high and low tidal volume state, respectively. Results : The peak inspiratory pressure was $32.6{\pm}4.72cmH_2O$ and the minimal occlusion pressure was $19.0{\pm}2.26$ mmHg in the basal ventilator setting. There was a significant relationship between the peak inspiratory pressure and the minimal occlusion pressure(r=0.77, p<0.01). The minimal occlusion pressure of the cuff was increased to $20.3{\pm}2.4$ mmHg in the high tidal volume state(p<0.05), and decreased to $16.8{\pm}3.01$ mmHg in the low tidal volume state (p<0.001). Conclusion : The minimal occlusion pressure of the cuff can be influenced by changes in the tidal volume as well as by the peak inspiratory pressure.

Factors Related to the Development of Myocardial Ischemia During Mechanical Ventilation (인공 호흡기 적용에 따른 심근 허혈의 발생에 관한 연구)

  • Kim, Tae-Hyung;Kim, You-Ho;Lim, Chae-Man;Kim, Won;Shim, Tae-Sun;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Koh, Youn-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.5
    • /
    • pp.645-653
    • /
    • 1999
  • Introduction : Although myocardial ischemia tends to occur more frequently than can he documented in ventilated patients, it has not been well studied on the factors related to the occurrence of the ischemia. Methods : To investigate the related factors to ischemia development, a prospective study was done in 95 cases with consecutive 73 patients who had received mechanical ventilation(MV) in MICU. In addition to 24 h holter monitoring, echocardiogram, electrolytes, cardiac enzymes, hemodynamic, and gas exchange measurements were done within 24 h after initiation of MV in 69 cases. The measurements were repeated at weaning period in 26 cases. The ischemia was defined by the ST segment changes; up-sloping depression more than 1.5 mm or down-sloping or horizontal depression more than 1.0 mm from isoelectric baseline for 80 ms following J point. Results : Twelve patients(12.6% in 95 cases) developed ischemia in total. The incidence of ischemia development showed an increased tendency in the initial 24 hr after MV (15.9%) and in patients with left-sided heart failure found by echocardiogram (18.2%) compared with that of the weaning period (3.8%) and patients without heart failure (10.9%) (P=0.12, P=0.09, in each). There were no differences in APACHE III score, baseline ECG findings, electrolytes abnormalities, use of inotropics or bronchodilators, presence of sepsis or shock, mode of ventilation, and survival rate according to the development of ischemia. Maximal heart rates and mean arterial pressure also were not different between patients with ($137.2{\pm}30.9/min$, $82.5{\pm}15.9$ mm Hg) and without ischemia ($l29.5{\pm}29.7/min$, $83.8{\pm}17.6$ mm Hg). Conclusion : Although the incidence of myocardial ischemia was 12.6% in total, there were no clinically predictable factors to the development of ischemia during mechanical ventilation.

  • PDF

Development of an Anaesthesia Ventilator by Volume Control Method and a Gas Monitoring System (가스 모니터 및 볼륨 제어 방식의 마취기용 인공 호흡기 개발)

  • Lee, Jong-Su;Seong, Jong-Hun;Kim, Yeong-Gil
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.37 no.4
    • /
    • pp.42-48
    • /
    • 2000
  • Generally an operator would take notice at putting a patient under anesthesia. If the operation is executed in mistake, the patient is exposed to danger. The object of this Paper is that a system is developed for an accuracy of system and a convenience of user interface to prevent an operation of several elements of risk by mistake. The part of electrical system particularly is made for convenience of a manipulation using electrical switch and encoder. A real-time monitoring system is developed for an airway pressure and a gas concentration of carbon dioxide of patient using graphic LCD(liquid crystal display). Moreover, this flow control system could be developed control with accuracy by feedback control method. This is implemented using flow control valve and flow sensor. The implemented system gives convenience and precision of a manipulation of variable value using developed technique. This system shows guaranteed stabilization and confidence of anesthesia ventilator by notifying us that patient's state and information in case of being out of alarm range of variable value.

  • PDF