• Title/Summary/Keyword: 인공관절

Search Result 315, Processing Time 0.028 seconds

Quantitative Analysis of Magnetization Transfer by Phase Sensitive Method in Knee Disorder (무릎 이상에 대한 자화전이 위상감각에 의한 정량분석법)

  • Yoon, Moon-Hyun;Sung, Mi-Sook;Yin, Chang-Sik;Lee, Heung-Kyu;Choe, Bo-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.98-107
    • /
    • 2006
  • Magnetization Transfer (MT) imaging generates contrast dependent on the phenomenon of magnetization exchange between free water proton and restricted proton in macromolecules. In biological materials in knee, MT or cross-relaxation is commonly modeled using two spin pools identified by their different T2 relaxation times. Two models for cross-relaxation emphasize the role of proton chemical exchange between protons of water and exchangeable protons on macromolecules, as well as through dipole-dipole interaction between the water and macromolecule protons. The most essential tool in medical image manipulation is the ability to adjust the contrast and intensity. Thus, it is desirable to adjust the contrast and intensity of an image interactively in the real time. The proton density (PD) and T2-weighted SE MR images allow the depiction of knee structures and can demonstrate defects and gross morphologic changes. The PD- and T2-weighted images also show the cartilage internal pathology due to the more intermediate signal of the knee joint in these sequences. Suppression of fat extends the dynamic range of tissue contrast, removes chemical shift artifacts, and decreases motion-related ghost artifacts. Like fat saturation, phase sensitive methods are also based on the difference in precession frequencies of water and fat. In this study, phase sensitive methods look at the phase difference that is accumulated in time as a result of Larmor frequency differences rather than using this difference directly. Although how MT work was given with clinical evidence that leads to quantitative model for MT in tissues, the mathematical formalism used to describe the MT effect applies to explaining to evaluate knee disorder, such as anterior cruciate ligament (ACL) tear and meniscal tear. Calculation of the effect of the effect of the MT saturation is given in the magnetization transfer ratio (MTR) which is a quantitative measure of the relative decrease in signal intensity due to the MT pulse.

  • PDF

A Study of Image Quality Improvement Through Changes in Posture and Kernel Value in Neck CT Scanning (경부 CT검사 시 Kernel 값과 검사자세 변화를 통한 화질개선에 관한 연구)

  • Kim, Hyeon-Ju;Chung, Woo-Jun;Cho, Jae-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.59-66
    • /
    • 2011
  • There is a difficulty because of classifying the anatomical structure in the neck CT scan by the beam hardening artifact no more than disease and it including the 6, 7 number cervical spine and intervertebral disk. In case of enforcing the neck CT scan cause of the inner diameter of beam artifact tried to be inquired by the image evaluation according to the change of the image evaluation according to the direction of the shoulder joint applying the variation method of a posture and location and Kernel value and it was most appropriate, the lion tax and Kernel value try to be searched for through an experiment. Somatom Sensation 16 (Siemens, Enlarge, Germany) equipment was used in a patient 30 people coming to the hospital for the neck CT scan. A workstation used the AW 4.4 version (GE, USA). According to a direction and location of the shoulder joint, the patient posture gave a change to the direction of the shoulder joint as the group S it gave a change as three postures and placed the both arms comfortably and helps a group N and augmented unipolar left in the wealthy merchant and group P it memorized the both hands and ordered the eversion and drops below to the utmost and enforced a scan. By using a reconstructing method as the second opinion, it gave and reconstructed the Kernel value a change based on scan data with B 10 (very smooth), B 20 (smooth), B 30 (medium smooth), B 40 (medium), B 50 (medium sharp), B 60 (sharp), and B 70 (very sharp). By using image data which gave the change of the examination posture and change of the Kernel value and are obtained, we analyzed through the noise value measurement and image evaluation of. The outside wire eversion orders the both hands and the examination posture is cost in the neck CT scan with the group P it drops below to the utmost. And in case of when reconstructing with B 40 (medium) or B 50 (medium sharp) being most analyzed into the inappropriate posture and Kernel value and applying the Kernel value to a clinical, it is considered to be very useful.

A CLINICAL STUDY ON MANDIBULAR MOVEMENT AFTER ORTHOGNATHIC SURGERY (악교정 수술환자의 술전후 하악운동 양상변화에 관한 임상적 연구)

  • Baek, Sang-Heum;Jang, Hyun-Jung;Lee, Sang-Han;Kim, Hyun-Soo;Cha, Doo-Won
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.3
    • /
    • pp.239-249
    • /
    • 2001
  • The purpose of this study is to evaluate the relationship of the factors which could be influenced by orthognathic surgery especillay SSRO. We measured the amounts of the maximum opening, lateral movements, maximum velocity and pattern of mandibular path during the opening and closing of mandible at the following times ; preoperative, 1 month after operation, 6 months after operation respectively using MKG. And the results were compared according to the categorized subgroups. Following results were obtained : 1. The change of the amounts of mandibular lateral movement and maximum opening velocity were statistically different between male and female (p<0.05), but the others were not. 2. According to the method of operation, there was no difference in the change of the mandibular movements between the group of SSRO and SSRO plus LeFort I osteotomy (p>0.05). 3. According to the amounts of mandibular movement, the recovery of left lateral movement of the group of $6{\sim}10mm$ was better than the other groups (p<0.05). 4. In the frontal pattern of the opening and closing of the mandible, the complex deflected type (F5), simple deflected type (F4), complex deviated type (F3), simple deviated type (F2), straight type (F1) were obtained in order at the time of preoperative, simple deflected type, simple deviated type, complex deviated type, straight type, complex deflected type in order at the time of 1 month after surgery, and the result at the time of 6 months after surgery was the same with that of the time of preoperative. In the sagittal pattern, non-coincident type (S2) was predominant at the time of preoperative, and coincident type (S1) was predominant at the time of 1 month after surgery. After 6 months, the result was also the same with that of the preoperative in sagittal pattern. 5. There was not a statistical difference in the change of the mandibular movement between group of presence of the preoperative TMJ symptoms and non-presence group (p>0.05). 6. There was not a statistical difference in the change of the mandibular movement between repositioning device applied group and non-applied group (p>0.05). 7. Sixty three percents of the patients who had preoperative TMJ symptoms were improved after surgery and preoperative TMJ symptoms were more improved after operation in the repositioning device non-applied group statistically (p<0.05).

  • PDF

A Biomechanical Study on a New Surgical Procedure for the Treatment of Intertrochanteric Fractures in relation to Osteoporosis of Varying Degrees (대퇴골 전자간 골절의 새로운 수술기법에 관한 생체역학적 분석)

  • 김봉주;이성재;권순용;탁계래;이권용
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.401-410
    • /
    • 2003
  • This study investigates the biomechanical efficacies of various cement augmentation techniques with or without pressurization for varying degrees of osteoporotic femur. For this study, a biomechanical analysis using a finite element method (FEM) was undertaken to evaluate surgical procedures, Simulated models include the non-cemented(i.e., hip screw only, Type I), the cement-augmented(Type II), and the cemented augmented with pressurization(Type III) models. To simulate the fracture plane and other interfacial regions, 3-D contact elements were used with appropriate friction coefficients. Material properties of the cancellous bone were varied to accommodate varying degrees of osteoporosis(Singh indices, II∼V). For each model. the following items were analyzed to investigate the effect surgical procedures in relation to osteoporosis of varying degrees : (a) von Mises stress distribution within the femoral head in terms of volumetric percentages. (b) Peak von Mises stress(PVMS) within the femoral head and the surgical constructs. (c) Maximum von Mises strain(MVMS) within the femoral head, (d) micromotions at the fracture plane and at the interfacial region between surgical construct and surrounding bone. Type III showed the lowest PVMS and MVMS at the cancellous bone near the bone-construct interface regardless of bone densities. an indication of its least likelihood of construct loosening due to failure of the host bone. Particularly, its efficacy was more prominent when the bone density level was low. Micromotions at the interfacial surgical construct was lowest in Type III. followed by Type I and Type II. They were about 15-20% of other types. which suggested that pressurization was most effective in limiting the interfacial motion. Our results demonstrated the cement augmentation with hip screw could be more effective when used with pressurization technique for the treatment of intertrochanteric fractures. For patients with low bone density. its effectiveness can be more pronounced in limiting construct loosening and promoting bone union.

Osteological Development of the Larvae and Juveniles of Takifugu pardalis (Teleostei: Tetraodontodae) (졸복 (Takifugu pardalis) 자치어의 골격발달)

  • Han, Kyeong-Ho;Cho, Jae-Kwon;Lee, Sung-Han;Hwang, Seon-Yeong;Yoon, Seung-Min;Seo, Won-II;Kim, Chun-Chel
    • Korean Journal of Ichthyology
    • /
    • v.17 no.1
    • /
    • pp.29-35
    • /
    • 2005
  • Fertilized eggs of Takifugu pardalis (Temminck et Schlegel) were collected on the coast of Jook-do in Tongyong, Korea, from March 1997 to June 1999, and hatched and reared in the laboratory to investigate osteological development of the larve and juveniles. The newly hatched larvae attained a mean of $3.13{\pm}0.05mm$ in total length (TL). Ossification first began in the parasphenoid, premaxillary and dentary. At 5 days after hatching, the postlarvae attained a mean of $3.82{\pm}0.03mm$ in TL, and their sphenotic, prefrontal, preopercle, opercle, maxillary, and articular were ossified. At 15 days, the postlarvae attained a mean of $7.84{\pm}0.06mm$ in TL, their nasal and posttemporal bones were ossified and the hyoid arch completed ossification. Ossification of all bones was completed in the juveniles (mean = $10.21{\pm}0.06mm$ in TL) at 21 days.

The Effects of Artificial Balneotherapy on Osteoarthritis (인공 온천수가 퇴행성 슬관절염에 미치는 효과)

  • Park Rae-Joon;Han Dong-Wook;Park Chang-Gon;Lee Hyun-Kee
    • The Journal of Korean Physical Therapy
    • /
    • v.15 no.2
    • /
    • pp.131-145
    • /
    • 2003
  • The purpose of this study was to evaluate effects of artificial balenotherapy on the with degenerative osteoarthritis were selected as the subject do this study among the patients with degenerative osteoarthritis having pains in their knees by the criteria of America Rheumatoid Association. And the randomly selected ten patients out of the twenty were classified as an artificial balenotherapy group and the other the Patients were in a control group. Ten individuals with degenerative osteoarthritis patients in the artificial balenotherapy group Participated in artificial balenotherapy Program four weeks from March 1st, 2003 to March 31st, 2003 in Daegu 00 hospital. Ten individuals with degenerative osteoarthritis in the control group did not receive Artificial Balenotherapy. The conclusions were as follows: 1. After 4 weeks of therapy, the score of WBC(p < 0.01), RBC(p < 0.01), HTC(p < 0.01) in the artificial blalenotherapy group were significantly decreased, compared with their scores in pre-intervention. 2.In the balenotherapy group, significantly increase $Na^{+}$ ion(P < 0.05), decrease K ion(p < 0.01), unchanged Cl ion scores were found, compared with their scores in pro-intervention. 3. The result of the substudy about the effects of artificial balenotherapy on the substances that have relations with the function of liver were following that artificial balenotherapy group, increased total bilirubin(P < 0.01), unchanged total Protein, Albumin, total cholesterol, GOT, GPT, ALP were found, compared with their score in pre-intervention. 4. The result of the substudy about the effects of artificial balenotherapy on the substances that have relations with the function of kidney were following that in the artificial balenotherapy group, reduced BUN(P < 0.05), and increased creatine were found. 5. The result of the substudy about effects of artificial balenotherapy on the knee pain visual analog score, knee's functional score, ADL score were following that in the artificial balenotherapy group, decreased VAS score(P < 0.05), increased ADL score(p < 0.01), unchanged knee's functional score were founf, compared with their scores of the pre-intervention. In conclusion, the result of this study suggest that artificial balenotherapy improved ADL score and reduced knee pain visual analog score of the patients with degenerative osteoarthritis. The result proposed that appropriate use of artificial balenotherapy improves the degenerative osteoarthritis

  • PDF

A Numerical Study on the Response of the Tibial Component in Total Knee Arthroplasty to Longitudinal Impact (인공무릎관절 전치환술에 있어 축방향 충격에 의한 Tibial Component의 응답 특성 분석 연구)

  • 조용균;조철형;최재봉;이태수;최귀원
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.503-511
    • /
    • 1998
  • In this study, the stress distribution for different tibial components was observed In order to Investigate the load transfer and potential failure mechanism of the tibial components subjected to dynamic impact loading and also to evacuate the effect of bone-implant bonding conditions on the implant system. The 3-dimensional finite element models included an intact tibia, cemented metal-backed tibial component, uncemented metal-blocked tibial component, cemented all-polyethylene tibial component, and metal-backed component with a debonded bone/stem interface. The results showed that the cemented metal-hocked component Induced slightly higher peak stress at stem tip than the uncemented component. The peak stress of the all-polyethylene tibia1 component at stem trip showed about half thats of metal-backed tibial components. The all-polyethylene component showed a similar dynamic response to intact tibia. In case of debonded bone/stem interface, the peak stress below the metal tray was three times Higher than that of the fully bonded interface and unstable stress distribution at the stem tip was observed with time, which causes another adverse bone apposition and implant loosening. Thus, the all-polyethylene tibial component bonded fully to the surrounding bone might be most desirable system under an impact loading.

  • PDF

Neutral zone approach and external impression for rehabilitation of macroglossia: a case report (거대설을 가진 환자에서 중립대 개념과 연마면 인상을 이용한 총의치 수복 증례)

  • Kang, Hyeon;Seo, Nu-Ri;Park, Sang-Won;Yun, Kwi-Dug;Park, Chan;Lim, Hyun-Pil
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.3
    • /
    • pp.218-224
    • /
    • 2018
  • Macroglossia is an obstacle in regard to general prosthodontic restoration. Not only is it difficult to obtain support and stability from dentures manufactured from normal protocol, obtaining efficacy from basic mastication is also difficult. In such cases, realizing harmony between the occlusion and surrounding muscle structures may be important with regard to manufacture of stable full dentures, and it is necessary to form the appropriate polished surface for this case. The neutral zone is defined as the potential area resulting from the neuromuscular function that results in equilibrium between the outward force exerted by the tongue and the inward force exerted by the lips and cheeks. The artificial teeth of the full denture lies in this area, and if the polished zone follows the anatomic form of the dynamic muscles, the movement of the muscles simply acts as an element of stabilizing the dentures improving the esthetics through facial support.

Hip Range of Motion Estimation using CT-derived 3D Models (CT기반 3차원 모델을 이용한 고관절 운동범위 예측)

  • Lee, Yeon Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.115-122
    • /
    • 2018
  • The success of the total hip arthroplasty is revealed as initial stability, range of motion, and long term pain, etc. Depending upon choice of implantation options such as femoral neck offset, diameter of the femoral head, the lateral opening tilt. Especially the impingement between femoral head component and acetabular cup limits the range of motion of the hip. In this sense, estimation or evaluation of the range of motion before and after the total hip arthroplasty is important. This study provides the details of a computer simulation technique for the hip range of motion of intact hip as well as arthroplasty. The suggested method defines the hip rotation center and rotation axes for flexion and abduction, respectively. The simulation uses CT-based reconstructed 3D models and an STL treating software. The abduction angle of the hip is defined as the superolateral rotation angle from sagittal plane. The flexion angle of the hip is defined as the superoanterior angle from the coronal plane. The maximum abduction angle is found as the maximum rotation angle by which the femoral head can rotate superolaterally about the anterior-posterior axis without impingement. The maximum flexion angle is found as the maximum rotation angle by which the femoral head can rotate superoanteriorly about the medial-lateral axis without impingement. Compared to the normal hip, the total hip replacement hip showed decreased abduction by 60 degrees and decreased flexion by 4 degrees. This measured value implies that the proposed measurement technique can make surgeons find a modification of increase in the femoral neck offset or femoral head, to secure larger range of motion.

Gait Analysis of Patients with Tumor Prosthesis around the Knee (인공 종양대치물을 이용한 사지구제술후의 보행 분석)

  • Lee, Sang-Hoon;Chung, Chin-Youb;Kim, Han-Soo;Kim, Byung-Sung;Lee, Han-Koo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.3 no.1
    • /
    • pp.18-25
    • /
    • 1997
  • Prosthetic replacement is one of the most common methods of reconstruction after resection of malignant tumor around the knee. Gait analysis provides a relative objective data about the gait function of patients with prosthesis. The purpose of this study was to compare the gait pattern of the patients who underwent limb salvage surgery with prosthesis for distal femur and that of patients with prosthesis for proximal tibia. This study included ten patients (4 males, 6 females, mean age 22.7 years, range 14-36) who underwent a wide resection and Kotz hinged modular reconstruction prosthesis replacement and six normal adult(Control). The site of bone tumor was the distal femur (Group 1) in six patients and proximal tibia (Group 2) in 4 patients. The follow-up period ranged from 15 to 82 months (mean : 33 months). The evaluation consisted of clinical assessment, radiographic assessment, gait analysis using VICON 370 Motion Analysis System. The gait analysis included the linear parameters such as, walking velocity, cadence, step length, stride length, stance time, swing time, single support and double support time and the three-dimensional kinematics (joint rotation angle, velocity of joint rotation) of ankle, knee, hip and pelvis in sagittal, coronal and transverse plane. For the kinetic evaluation, the moment of force (unit: Nm/kg) and power (unit: Watt/kg) of ankle, knee and hip joint in sagittal, coronal and transverse plane. In the linear parameters, cadence, velocity, step time and single support were decreased in both group 1 and group 2 compared with control. Double support decreased in group 2 compared with control significantly(p<.05). In contrast to our hypothesis, there was no significant difference between group 1 and group 2. In Kinematics, we observed significant difference (p<.05) of decreased knee flexion in loading response (G2

  • PDF