• Title/Summary/Keyword: 이하선 종양

Search Result 191, Processing Time 0.027 seconds

Fuzzy-based Segmentation Algorithm for Brain Images (퍼지기반의 두뇌영상 영역분할 알고리듬)

  • Lee, Hyo-Jong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.12
    • /
    • pp.102-107
    • /
    • 2009
  • As technology gets developed, medical equipments are also modernized and leading-edge systems, such as PACS become popular. Many scientists noticed importance of medical image processing technology. Technique of region segmentation is the first step of digital medical image processing. Segmentation technique helps doctors to find out abnormal symptoms early, such as tumors, edema, and necrotic tissue, and helps to diagnoses correctly. Segmentation of white matter, gray matter and CSF of a brain image is very crucial part. However, the segmentation is not easy due to ambiguous boundaries and inhomogeneous physical characteristics. The rate of incorrect segmentation is high because of these difficulties. Fuzzy-based segmentation algorithms are robust to even ambiguous boundaries. In this paper a modified Fuzzy-based segmentation algorithm is proposed to handle the noise of MR scanners. A proposed algorithm requires minimal computations of mean and variance of neighbor pixels to adjust a new neighbor list. With the addition of minimal compuation, the modified FCM(mFCM) lowers the rate of incorrect clustering below 30% approximately compared the traditional FCM.

CASE REPORT OF PILOMAIRICOMA (Pilomatricoma 환아에 대한 증례 보고)

  • Seo, Hyun-Woo;Kim, Ji-Hyuck;Park, Ho-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.1
    • /
    • pp.79-84
    • /
    • 2004
  • Pilomatricoma is a benign soft tissue tumor of hair follicle origin. They occur most commonly in the head and neck region and are usually found in girls during the first two decades of life. Although malignant transformation has been described, it is exceedingly rare. The clinical presentation is typically that of an asymptomatic, superfical, solitary, firm mass that is often accompanied by a reddish-blue discoloration of the overlying skin. Histopathologically pilomatricoma are seen as epithelial islands embedded in a cellular stroma. The epithelial component consist of two main cell types : basaloid cells and ghost cells. Intracellular and stromal calcification is reported in many cases. Diagnosis is usually suspected based on palpation of a superficial, rock-hard mass and confirmed by histopathologic examination. Surgical excision is both curative and the treatment of choice. Recurrence is rare. In this case, the radiographs showed a dense calcification, measuring about 1cm diameter. So simple excision was peformed intraorally, and resultantly the lesion was proved to be a pilomatricoma by histological examination.

  • PDF

Primary Squamous Cell Carcinoma of the Parotid Gland (원발성 이하선 편평상피세포암종)

  • Lee Sang-Wook;Kim Gwi-Eon;Park Cheong-Soo;Park Won;Lee Chang-Geol;Keum Ki-Chang;Lim Ji-Hoon;Yang Wook-Ick;Suh Chang-Ok
    • Korean Journal of Head & Neck Oncology
    • /
    • v.13 no.2
    • /
    • pp.228-234
    • /
    • 1997
  • Squamous cell carcinoma originating in the parotid gland has rare occurrence. The primary squamous cell carcinoma of the parotid gland comprise about 0.3% and 9.8% of all parotid malignant tumor. We investigated the clinical behavior and treatment outcome of patients with primary squamous cell carcinoma of the parotid gland. We reviewed all cases of possible primary squamous cell carcinoma of the parotid gland treated at Yonsei Cancer Center, Seoul, Korea, from 1981 through 1995. A total of 128 had primary parotid malignancy. Metastatic squamous cell carcinoma and mucoepidermoid carcinoma were excluded in this study. Ten cases of primary squamous cell carcinoma of the parotid gland were identified. 6 cases of them are men & 4 cases are women. The age of patients ranged from 31 to 68 years with median age of 55 years. On physical examination, 5 cases had palpated cervical neck node and 6 cases had facial nerve palsy. Staging was done according to the current guidelines established by the American Joint Committee on Cancer (1992). Two cases were stage I, 1 in stage III, and 7 in stage IV. Six cases were performed operation and postoperative radiation therapy. Four cases were treated by curative radiation therapy, dose of more than 65 Gy on parotid gland region. The 5 year actual survival rate and the 5 year disease free survival rate were 30.8%, and 40.0%. Initial complete response rate was 70% for all patients. Local failure were occurred 3 of 7 patients with local controlled cases, failure sites were primary site, ipsilateral cervical neck node, contralateral supraclavicular node. Most recurrences developed within 1 year of initial treatment. Distant metastasis was appeared 2 of 3 patients who did not achieved local control. Primary squamous cell carcinoma of the parotid gland occured infrequently. A retrospective study at the Yonsei Cancer Center indicates incidence of 7.8%. At diagnosis, advanced stage, neck node presentation, facial nerve paralysis were associated with a poor prognosis. These results may suggested that radical surgical excision may be treatment of choice and that planned postoperative radiotherapy may be bendicial for reducing locoregional recurrence rates.

  • PDF

Parotid Mass as First Presentation of Malignant Lymphoma (이하선 종괴로 발현된 악성 림프종)

  • Chung Woong-Youn;Lee Hyo-Sang;Seo Jin-Hak;Yang Woo-Ik;Park Cheong-Soo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.17 no.1
    • /
    • pp.26-31
    • /
    • 2001
  • Background: Primary malignant lymphoma of the parotid gland is a rare disease and defined as any malignant lymphoma that first manifests in the parotid gland, regardless of the subsequent stage of the diseases, whether it arises in the parenchyma or intraglandular lymph nodes. This study was performed to review the clinicopathological characteristics of primary parotid lymphoma and identify its optimal treatment modality. Materials and Methods: Six cases with parotid mass as first presentation of malignant lymphoma between 1988 and 2000, were studied on the basis of clinical features, diagnostic tools, treatment modality, treatment outcomes, and clinical stage by Ann Arbor Criteria. All were microscopically reevaluated and classified by NCI working formulation. Results: All patients were males and mean age was 36.7 years (2-66 years). Rapid growing non-tender mass was presented in all the cases and cervical lymphnodes were palpated in 4 cases. However, there was not any evidence of concurrent autoimmune disease such as Sjogren's syndrom or Rheumatoid arthritis. One case was confirmed by surgical specimen after superficial parotidectomy, 2 by excisional biopsy, and 3 by incisional biopsy. The stage of disease by NCI working formulation was IE in 1 patient, IIE in 4 and IV in 1. All were classified into non-Hodgkin' lymphoma, of which there were 5 cases of B-cell type and 1 case of T-cell type. There were 3 diffuse large cell lymphomas, 1 Burkitt lymphoma, 1 MALT lymphoma and 1 T-lymphoblastic lymphoma. Three cases were treated by chemotherapy only, 2 by radiotherapy only and 1 by chemo-radiotherapy. One case with Burkitt lymphoma was died from the disease and one case was lost to follow-up. The others are alive with no evidence of recurrence. Conclusions: Although primary parotid lymphoma is rare and difficult to diagnose preoperatively, most were detected in early stage and showed a relatively good response to the chemotherapy or radiotherapy like other types of extranodal malignant lymphoma.

  • PDF

Warthin Tumor on the Parotid Gland: A Case Report (우측 이하선에 발생한 Warthin 종양: 증례보고)

  • Min, Sungchang;Yoon, Kyuho;Park, Kwansoo;Cheong, Jeongkwon;Bae, Jungho;Jo, Kyuhong;Han, Jihoon;Oh, Youngil;Shin, Jaemyung;Baik, Jeeseon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.6
    • /
    • pp.473-479
    • /
    • 2012
  • Warthintumor (WT), also known as adenolymphoma or papillary cystadenoma lymphomatosum, was described in 1895 for the first time. It is a common benign tumor of the parotid glands and the second most common neoplasm of the salivary gland, accounting for 5% to 14% of all parotid neoplasm. A 63-year-old man visited our clinic with the complaint of swelling on the right parotid gland. Physical examination showed a 3 cm, firm, well-circumscribed, painless mass on the right mandibular angle. Computed tomography imaging showed a $3.5{\times}2.0{\times}1.6$ cm well-defined cystic mass. WT is histologically characterized by bilayered, oncocystic cell, lymphoid stroma, and cystic space. With these typical cytomorphologic characteristics, the fine-needle aspiration cytology was performed as diagnostic tool before the surgery. The lymphocytes and oncocystic cell were not observed. The lesion was completely excised under general anesthesia. We diagnosed the case as WT, from the surgically excised specimen. We report on the case with a review of the literatures.

Analysis on the Positional Accuracy of the Non-orthogonal Two-pair kV Imaging Systems for Real-time Tumor Tracking Using XCAT (XCAT를 이용한 실시간 종양 위치 추적을 위한 비직교 스테레오 엑스선 영상시스템에서의 위치 추정 정확도 분석에 관한 연구)

  • Jeong, Hanseong;Kim, Youngju;Oh, Ohsung;Lee, Seho;Jeon, Hosang;Lee, Seung Wook
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.143-152
    • /
    • 2015
  • In this study, we aim to design the architecture of the kV imaging system for tumor tracking in the dual-head gantry system and analyze its accuracy by simulations. We established mathematical formulas and algorithms to track the tumor position with the two-pair kV imaging systems when they are in the non-orthogonal positions. The algorithms have been designed in the homogeneous coordinate framework and the position of the source and the detector coordinates are used to estimate the tumor position. 4D XCAT (4D extended cardiac-torso) software was used in the simulation to identify the influence of the angle between the two-pair kV imaging systems and the resolution of the detectors to the accuracy in the position estimation. A metal marker fiducial has been inserted in a numerical human phantom of XCAT and the kV projections were acquired at various angles and resolutions using CT projection software of the XCAT. As a result, a positional accuracy of less than about 1mm was achieved when the resolution of the detector is higher than 1.5 mm/pixel and the angle between the kV imaging systems is approximately between $90^{\circ}$ and $50^{\circ}$. When the resolution is lower than 1.5 mm/pixel, the positional errors were higher than 1mm and the error fluctuation by the angles was greater. The resolution of the detector was critical in the positional accuracy for the tumor tracking and determines the range for the acceptable angle range between the kV imaging systems. Also, we found that the positional accuracy analysis method using XCAT developed in this study is highly useful and will be a invaluable tool for further refined design of the kV imaging systems for tumor tracking systems.

Evaluation of the usefulness of Bolus, which combines Step Bolus and 3D Bolus (Step Bolus와 3D Bolus를 combine 한 Bolus의 유용성 평가)

  • Lee, Chang-Suk;Chae, Moon-Ki;Park, Byung-Suk;Kim, Sung-Jin;Joo, Kyoo-Sang;Park, Chul-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.79-88
    • /
    • 2021
  • Objectives: Bolus, which combines 3D-bolus and Step-bolus, was produced and its usefulness is evaluated. Materials and Methods: A Bolus was manufactured with a thickness of 10mm and 5mm using a 3D printer (3D printer, USA), and a Step Bolus of 5mm was bonded to a 5mm thick bolus. In order to understand the characteristics of Step bolus and 3D bolus, the differences in relative electron density, HU value, and mass density of the two bolus were investigated. These two Bolus were applied to anthropomorpic phantom to confirm its effectiveness. After all contouring of the phantom, a treatment plan was established using the computed treatment planning system (Eclipse 16.1, Varian medical system, USA). Treatment plan was performed using electron beam 6MeV, nine dose measurement points were designated on the phantom chest, air-gap was measured at that point, and dose evaluation was performed at the same point for each bolus applied using a glass dosimeter (PLD). Results: Bolus, which combines 3D-bolus 5mm and Step-bolus 5mm, was manufactured and evaluated compared with 3D-bolus 1cm. The relative electron density of 3D Bolus was 1.0559 g/cm2 and the step Bolus was 1.0590 g/cm2, which was different by 0.01%, so the relative electron density was almost the same. In the lightweight measurement of air-gap, the combined bolus was reduced to 54.32% for all designated points compared to 3D-bolus. In the dose measurement using a glass dose meter (PLD), the consistency was high in phantom using combined bolus at most points except the slope point. Conclusion: Combined bolus made by combining 3D-bolus and Step-bolus has all the advantages of 3D-bolus and Step-bolus. In addition, by dose inaccuracy due to Air-gap, more improved dose distribution can be shown, and effective radiation therapy can be performed.

Change of Dose Distribution on the Beam Axis of 60Co γ Ray and 10MV X-Ray with Part Thickness (치료부위(治療部位)두께에 따른 Co-60 γ선(線)과 10MV X선(線)의 선축상(線軸上) 선량분포(線量分布)의 변화(變化))

  • Kang, Wee Saing;Koh, Kyoung Hwan;Ha, Sung Whan;Park, Charn Il
    • Radiation Oncology Journal
    • /
    • v.1 no.1
    • /
    • pp.21-24
    • /
    • 1983
  • The thickness of the part being irradiated is finite. Percent depth dose tables being used routinely are generally obtained from dosimetry in a phantom much thickner than usual patient. At or close to exit surface, the dose should be less than that obtained from the percent depth dose tables, because of insufficient volume for backscattering. To know the difference between the true absorbed dose and the dose obtained from percent depth dose table, the doses at or close to the exit surface were measured with plate type ionization chamber with volume of 0.5ml. The results are as follows; 1. In the case of $^{60}Co$, percent depth dose at a given depth increases with underlying phantom thickness up to the 5cm. 2. In the case of $^{60}Co$, the dose correction factor at exit surface which is less than 1, increases with part thickness and decreases with field size. 3. Exposure time may not be corrected when the part above 10cm in thickness is treated by $^{60}Co$. 4. In the case of 10MV x-ray, the dose correction factor is nearly 1 and constant for the underlying phantom thickness and field size, so the correction of monitor unit is not necessary for part thickness.

  • PDF

The Effects of Diltiazem and Pentoxifylline on Apoptosis of Irradiated Rat Salivary Gland (흰쥐 침샘의 방사선조사시 Apoptosis에 대한 Diltiazem과 Pentoxifylline의 효과)

  • Yang, Kwang-Mo;Suh, Hyun-Suk
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.367-375
    • /
    • 1998
  • Purpose : Xerostomia is a complication met by almost all patients who have radiotherapy for cancers of head and neck. Many studies for prevention of xerostomia will be necessary. Radiation-induced acute response of salivary glands has been defined as interphase death or apoptosis. Increased intracellular calcium level have an important role in radiation-induced apoptosis. Calcium channel blocker may prevent radiation-induced apoptosis of salivary glands. This study was designed to evaluate the effectiveness of diltiazem known as calcium channel blocker and pentoxifylline with inhibition of inflammatory response on the apoptosis as an acute response of radiation in rat salivary glands. Materials and Methods : Sprague-Dawley rats with about body weight 200-250 g were divided into 5 study groups : control, radiation alone, diltiazem with radiation, pentoxifylline with radiation, and diltiazem and pentoxifylline with radiation. The diltiazen and pentoxifylline were injected intraperitoneally 20 mg/kg and 50 mg/kg, 30 and 20 mimute before irradiation. respectively. Irradiation was given with a 4 MV linear accelerator. The 1600 cGy of radiation was delivered in a single fraction through a single anterior portal encompassing the entire neck. After 24 h of irradiation, rats were sacrificed and parotid and submandibular glands were removed and stained with hematoxylin and eosin. The quantification of apoptosis was performed by microscopic examination of stained tissue sections at a magnification of 200X and the percentage of apoptotic cell was calculated. Results : On parotid glands, the percentage of apoptosis by radiation alone, diltiazem with radiation, pentoxifylline with radiation, and diltiazem and pentoxifylline with radiation were 1.72$\%$ (8.35/486), 0.64$\%$ (2.9/453), 0.23$\%$ (1.2/516), and 0.28$\%$ (1.1/399), respectively. The apoptosis was markedly reduced in the groups receiving drugs compared with groups receivinge, radiation alone (p<0.05). In serous cell of submandibular glands, the percentages of apoptosis of radiation alone, diltiazem with radiation, pentoxifylline with radiation, and diltiazem and pentoxifylline with radiation were 1.94$\%$ (l1/567), 0.34$\%$ (1.9/554), 0.28$\%$ (1.8/637), and 0.22$\%$ (1.3/601), respectively. In the mucus cell of submandibular glands, the percentages of apoptosis were 0.92$\%$ (5.1/552), 0.41$\%$ (2.5/612), 0.29$\%$ (1.3/455), and 0.18$\%$ (1.0/562), respectively. The apoptosis was markedly reduced in the serous glands (p<0.05), but there was no difference in development of apoptosis in each group of mucus gland. Conclusion : These results suggest that radiation-induced apoptosis of serous cells of salivary glands may be decreased by diltiazem and pentoxifylline administration.

  • PDF

MOSFET Dosimetry for Evaluation of Gonad Shielding during Radiotherapy (방사선 치료시 생식선 차폐체 성능 평가를 위한 MOSFET 선량 측정)

  • Kim, Hwi-Young;Choi, Yun-Seok;Park, So-Yeon;Park, Yang-Kyun;Ye, Sung-Joon
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.1
    • /
    • pp.23-27
    • /
    • 2011
  • In order to confirm feasibility of MOSFET modality in use of in.vivo dosimetry, evaluation of gonad shielding in order to minimize gonadal dose of patients undergoing radiotherapy by using MOSFET modality was performed. Gonadal dose of patients undergoing radiotherapy for rectal cancer in the department of radiation oncology of Seoul National University Hospital since 2009 was measured. 6 MV and 15 MV photon beams emitted from Varian 21EX LINAC were used for radiotherapy. In order to minimize exposed dose caused by the scattered ray not only from collimator of LINAC but also from treatment region inside radiation field, we used box.shaped lead shielding material. The shielding material was made of the lead block and consists of $7.5\; cm\;{\times}\;9.5\;cm\;{\times}5.5\;cm$ sized case and $9\;cm\;{\times}\;9.5\;cm\;{\times}\;1\;cm$ sized cover. Dosimetry for evaluation of gonad shielding was done with MOSFET modality. By protecting with gonad shielding material, average gonadal dose of patients was decreased by 23.07% compared with reference dose outside of the shielding material. Average delivered gonadal dose inside the shielding material was 0.01 Gy. By the result of MOSFET dosimetry, we verified that gonadal dose was decreased by using gonad shielding material. In compare with TLD dosimetry, we could measure the exposed dose easily and precisely with MOSFET modality.