• 제목/요약/키워드: 이중덕트

검색결과 27건 처리시간 0.019초

국소환기시스템의 후드형상 개선에 따른 수치해석 (Numerical Analysis on Hood Shape Improvement of Local Ventilation System)

  • 이중섭;장성철;최주홍
    • 설비공학논문집
    • /
    • 제21권4호
    • /
    • pp.260-265
    • /
    • 2009
  • The aim of this study is to remove crack on a ventilation device at the suction part of zinc plating factory, and the main point is making optimum configuration by improving an existing hood system. The result shows that existing hood system has problem with duct configuration, angle and reducer. Model-5 shows lowest pressure difference as meaning of suction capability. The hood inlet surface has most uniform suction capability.

천창의 유형및 특성에 관한 연구 -빛의 유입 방법을 중심으로- (A Study on the Typology and the Characteristics of the Architectural Zenithal Opening -Focused on the Inflow Methods of the Zenithal Light-)

  • 류주희;김영석
    • 한국산학기술학회논문지
    • /
    • 제16권8호
    • /
    • pp.5619-5626
    • /
    • 2015
  • 천광(Zenithal Light)은 벽의 높은 곳에 위치한 창이나 지붕의 열린 부분으로부터 내부 혹은 중정과 같은 내부와 비슷한 공간에서 하강하면서 들어오는 빛으로, 본 연구에서는 이러한 천광을 이루는 천창의 다양한 사례들과 함께 빛이 들어오는 방식에 대한 유형을 구분하고 그 특성을 살펴보았다. 즉, 천창의 가장 큰 특징을 형성하는 것 중 하나로서 빛을 실내에 유입하는 구조적인 장치에 주목하고 이러한 장치인 매개체에 따라 크게 직사광형 덕트형, 쉐이드형으로 구분하고, 각각 세부적으로 변형된 유형으로 나누었다. 즉, 직사광형은 광원 비노출형과 광원 노출형으로 덕트형천창은 집중형과 분산형으로, 쉐이드형은 천정면형, 반사판형, 이중천창형, 수직벽면형 등으로 구분될 수 있다.

동심축 이중관 구조에서 유동기인진동 특성 고찰 (Investigation of FIV Characteristics on a Coaxial Double-tube Structure)

  • 송기남;김용완;박상철
    • 대한기계학회논문집A
    • /
    • 제33권10호
    • /
    • pp.1108-1118
    • /
    • 2009
  • A Very High Temperature Gas Cooled Reactor (VHTR) has been selected as a high energy heat source of the order of $950^{\circ}C$ for nuclear hydrogen generation, which can produce hydrogen from water or natural gas. A primary hot gas duct (HGD) as a coaxial double-tube type cross vessel is a key component connecting a reactor pressure vessel and an intermediate heat exchanger in the VHTR. In this study, a structural sizing methodology for the primary HGD of the VHTR is suggested in order to modulate a flow-induced vibration (FIV). And as an example, a structural sizing of the horizontal HGD with a coaxial double-tube structure was carried out using the suggested method. These activities include a decision of the geometric dimensions, a selection of the material, and an evaluation of the strength of the coaxial double-tube type cross vessel components. Also in order to compare the FIV characteristics of the proposed design cases, a fluid-structure interaction (FSI) analysis was carried out using the ADINA code.

적응 능동소음제어를 위한 오차경로 인식 방법을 통한 filtered-X LMS 알고리듬 (A Filtered-X LMS Algorithm by New Error Path Identification Method for Adaptive Active Noise Control)

  • 권기룡;송규익;김덕규;이건일
    • 한국통신학회논문지
    • /
    • 제19권8호
    • /
    • pp.1528-1535
    • /
    • 1994
  • 본 논문에서는 적응 능동소음제어를 위한 새로운 오차경로 인식 방법을 통한 filtered-X LMS(least mean square) 알고리듬을 제안하였다. 제안한 알고리듬에서는 3개의 마이크로폰과 이중루프제어를 이용하여 오차경로의 전달 특성을 온라인으로 정확히 인식하도록 하였다. 덕트를 통한 소음이 정형파인 경우와 실제 공조기의 소음에 대하여 컴퓨터 시뮬레이션을 각각 수행한 결과, 제안한 방식은 입력소음에 비하여 각각 평균 29.1dB 및 10.4dB 정도의 소음레벨이 감쇠됨을 확인하였다. 이는 Eriksson의 방법보다 각각 평균 0.5dB 및 2.5dB 정도 개선된 것이다.

  • PDF

고층건물에서 연돌효과를 활용한 자연환기시스템 설계를 위한 이론적 고찰 (A Theoretical Study for Stack Effect driven Natural Ventilation System in High-rise Building)

  • 윤성민;서정민;김양수;이중훈;송두삼
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.123-129
    • /
    • 2009
  • In these days, the green building movement caused by the energy crisis is increasing, passive design is getting mere and more attention as it provides many possibilities for energy conservation. Moreover, with the increasing social intention for healthy life, the demand for indoor air Quality is increasing in Korea. As result, the ventilation system which can provide the sound outdoor air constantly has been obliged in Korea. So, the hybrid system which using natural power and mechanical power and makes up for the shortage of mechanical and natural ventilation attracts people's attention in Korea. As a hybrid ventilation system, in this study, the stack effect driven hybrid ventilation system in high-rise residential building will be suggested. And in this paper, the theoretical review for hybrid ventilation system suggested in this study will be addressed. Especially, the characteristics of pressure distribution and airflow caused by stack effect in high-rise residential building and the possibility of natural ventilation as results of stack effect will be described.

  • PDF

덕트내에서의 능동 소음 제거를 위한 Transducer의 최적 위치 선정 (Optimal Selection of Transducer Locations for Active Cancelation of Noise in a Duct)

  • 남현도;강택동
    • 조명전기설비학회논문지
    • /
    • 제13권1호
    • /
    • pp.102-110
    • /
    • 1999
  • 제어용 스피커 및 검출용 마이크로폰 등 트랜스듀서들의 위치는 능동 소음제어 시스템의 성능에 큰 영향을 미친다. 능동 소음제어 시스템의 음향 특성이 매우 복잡하고, 유체 밀도, 복소 전파계수 등 음향 파라미터들의 값을 실제 적용 시에는 알 수 없는 경우가 많아 트랜스듀서들의 위치가 능동 소음제어 시스템의 성능에 미치는 영향을 해석적으로 구하기는 매우 어렵다. 본 논문에서는 트랜스듀서들 간의 전달함수들을 중첩의 원리를 이용하여 유도하였으며, 트랜스듀서들 간의 거리가 능동 소음제어 시스템의 성능에 미치는 영향을 컴퓨터 시뮬레이션을 통해 연구하였다. 단일극 시스템은 소음원과 제어 음원 사이의 거리에 영향을 받으며, 이중극 시스템은 두 제어 음원 사이의 거리와 소음원과 1차 제어 음원 사이의 거리에 많은 영향을 받는 것을 알 수 있었다.

  • PDF

전산유체역학을 이용한 단일 송풍기가 적용된 공냉식 연소설비의 효율개선 (Enhancement of combustion efficiency of a air-cooled combustor system with single F.D. Fan Using CFD)

  • 김민철;손병현;이재정;박흥석
    • 한국산학기술학회논문지
    • /
    • 제22권6호
    • /
    • pp.460-468
    • /
    • 2021
  • 본 연구는 multi fan 방식의 "공랭식 연소설비"의 공정관리상의 문제점을 single F.D. fan 으로 대체하여 개선시키기 위해 CFD 진행하였고, 연소로 내 유동조건 변화를 분석하여 문제점을 확인하였다. 이를 개선하기 위해 연소공기 주입구조를 변경하였고, 구조 변화에 따른 연소효율 개선을 수치해석으로 평가하였다. 또한 실제 연소설비에 수치해석결과를 반영하여 구조개선을 한 후 개선 전·후의 연소효율을 실험적으로 측정하였다. 먼저 기존 Single F.D fan 이 적용된 연소설비에 대한 수치해석을 통해, 2개의 유로로 공급되는 연소공기가 각 유로의 마찰력 차이와 압력의 변화로 인해 연소로 내에서 공급비율이 불규칙하게 되어 선회방식의 연소조건을 위한 축 형태의 난류형성이 어려움을 확인하였다. 이를 개선하기 위해서 연소로에 주입하는 공기 공급 방식을 두 가지로 나누어 수치해석을 하였다. 첫 번째 방식은 연소공기를 외벽에서 180 ~ 360° 회전 후 예열된 연소공기가 주입되는 구조에 대하여 검토하였고, 두 번째는 연소로 내에는 선회할 수 있는 베인(vane) 구조를 적용하여 연소로 밖에서 1차 열교환 후 연소로 내부에 접선방향으로 연소공기가 주입되는 구조에 대하여 검토하였다. 그 결과, single F.D. fan을 가진 공랭식 연소로에 선회방식으로 공기를 주입할 경우, 연소로 외벽의 냉각과 연소로 내부의 완전혼합 유지를 위해 이중 냉각벽을 가지는 덕트 구조를 적용하는 것이 연소조건을 최적화하는데 바람직한 것으로 나타났으며, 실제 운영중인 설비에 적용하여 개선 전·후의 연소효율을 비교한 결과 연소효율이 개선되는 것을 확인할 수 있었다.