• Title/Summary/Keyword: 이중냉각

Search Result 119, Processing Time 0.024 seconds

Experimental Analysis of Fretting Wear Behaviors in Elastic Deformable Contacts (탄성변형 접촉에서 프레팅 마멸거동의 실험적 분석)

  • Lee, Young-Ho;Kim, Hyung-Kyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.1
    • /
    • pp.49-54
    • /
    • 2010
  • Fretting wear behavior under elastic deformable contacts was experimentally examined by using a simulated dual cooled fuel rod and its supporting structure. As this fuel rod has larger outer diameter than the typical solid rod to accommodate sufficient internal flow, new supporting structure geometries should be designed and their reliabilities (i.e. vibration characteristics, fretting wear resistance, etc.) are also examined with both analytical and experimental methods. In this study, the supporting structure characteristics and fretting wear behaviors are analyzed and examined by using one of the supporting structure candidates which has an embossing shape. The supporting structure characteristics were examined by using a specially designed test rig and their results were compared with that of analytical method. Based on the test results, the relationship between the supporting structure characteristics and their fretting wear behaviors was discussed in detail.

원자로 효율 향상을 위한 이중냉각핵연료 유동설계 방안

  • Jo, Hyeong-Hui;Kim, Gyeong-Min;Kim, Tae-Hwan;In, Wang-Gi;Sin, Chang-Hwan
    • Journal of the KSME
    • /
    • v.52 no.3
    • /
    • pp.32-36
    • /
    • 2012
  • 이 글에서는 가압경수로의 성능 향상을 위해 연구 중인 이중냉각핵연료를 소개하고, 성능 향상을 위해 수행 중인 실험 및 수치해석을 이용한 유동설계 방법을 소개하고자 한다.

  • PDF

이것이 신기술이다 - F/1.0 이중배율 비냉각 열화상카메라 광학계 개발

  • Kim, Hyeon-Gyu
    • The Optical Journal
    • /
    • s.122
    • /
    • pp.41-43
    • /
    • 2009
  • 본 연구에서는 최근에 민수용으로 활용 빈도가 높은 $320{\times}240$ 어레이를 갖는 비냉각 검출기에 적합하도록 F/1.0. 이중배율 광학계를 설계제작하여 열영상을 획득하고 광학성능을 확인하기 위하여 최소분해가능온도차(MRTD; Minimum Resolvable Temperature Difference) 값을 측정하고 사람과 차량의 탐지를 추정하였다.

  • PDF

Examination of Forced Convection Heat Transfer Performance of a Twist-Vane Spacer Grid for a Dual-Cooled Annular Fuel Assembly (이중냉각 환형핵연료 집합체를 위한 비틀림 혼합날개 지지격자의 강제대류열전달 성능 검토)

  • Lee, Chi Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.1
    • /
    • pp.53-62
    • /
    • 2017
  • The forced convection heat transfer performance of a twist-vane spacer grid for a dual-cooled annular fuel assembly was examined experimentally. The twist-vane spacer grid was uniquely designed to enhance mixing inside subchannels and mixing between adjacent subchannels. For testing, a $4{\times}4$ square-arrayed rod bundle with narrow gaps between rods was prepared as the dual-cooled annular fuel assembly to be simulated. The pitch-to-rod diameter ratio of simulated dual-cooled annular fuel assembly was 1.08. The experiments were performed under the following conditions: axial bulk velocity, 1.5 m/s and heat flux, $26kW/m^2$. With regard to the circumferential temperature distribution, the lowest rod-wall temperatures upstream and downstream were measured at the subchannel center and the position toward the tip of twist-vane, respectively. With regard to the axial temperature distribution, behind the twist-vane spacer grid, the rod-wall temperature decreased drastically, and the Nusselt number was enhanced by up to 56 %. The present measured data indicate that the twist-vane spacer grid can effectively improve the forced convection heat transfer in the dual-cooled annular fuel assembly with narrow gaps.

Effects of the Lateral Ejection Angles and Distances of Double-Jet Holes on Flim Cooling Effectiveness (이중분사 막냉각 홀의 측면 분사각 및 홀 사이의 거리가 막냉각 효율에 미치는 영향)

  • Choi, Dae-Woong;Lee, Ki-Don;Kim, Kwang-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.4
    • /
    • pp.33-41
    • /
    • 2012
  • In the present work, a parametric study on double-jet film-cooling has been carried out to enhance the film-cooling effectiveness using three-dimensional Reynolds-averaged Navier-Stokes analysis. The shear stress transport turbulence model is used as the turbulence closure. The lateral ejection angles and the lateral and streamwise distance between the centers of the cooling holes are chosen as the geometric parameters. The spatially averaged film-cooling effectiveness averaged over an area of 8 hole diameters in width and 30 hole diameters in streamwise length is used to evaluate the performance of film-cooling. The parameter of the lateral distance has the largest impact on the film cooling effectiveness compared to the others. On the other hand, the parameter of streamwise distance gives the least influence on the film cooling effectiveness.

Mechanical Performance Evaluation of a Top End Piece for Dual Cooled Fuels (이중냉각 핵연료 상단고정체의 기계적 성능평가)

  • Kim, Jae-Yong;Yoon, Kyung-Ho;Kim, Hyung-Kyu;Choi, Woo-Seok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.4
    • /
    • pp.417-424
    • /
    • 2011
  • A fuel assembly consists of five major components, i.e., a top end piece (TEP), a bottom end piece (BEP), spacer grids (SGs), guide tubes (GTs) and an instrumentation tube (IT); in addition, it also includes fuel rods (FRs). The TEP/BEP should satisfy stress intensity limits according to the conditions A and B of ASME, Section III, Division 1-Subsection NB. In a dual-cooled fuel assembly, the array and position of fuel rods are different from those in a conventional PWR fuel assembly; these changes are necessary for achieving power uprating. The flow plates of the TEP and BEP have to be modified accordingly. The pattern and shape of the flow holes were newly designed. To verify the strength compatibility, the Tresca stress limit according to the ASME code was investigated in the case of an axial load of 22.241 kN. In this paper, the stress linearization procedure for strength evaluation of a newly designed TEP is presented.

Development of Double Rotation C-Scanning System and Program for Under-Sodium Viewing of Sodium-Cooled Fast Reactor (소듐냉각고속로 소듐 내부 가시화를 위한 이중회전구동 C-스캔 시스템 및 프로그램 개발)

  • Joo, Young-Sang;Bae, Jin-Ho;Park, Chang-Gyu;Lee, Jae-Han;Kim, Jong-Bum
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.338-344
    • /
    • 2010
  • A double rotation C-scanning system and a software program Under-Sodium MultiVIEW have been developed for the under-sodium viewing of a reactor core and in-vessel structures of a sodium-cooled fast reactor KALIMER-600. Double rotation C-scanning system has been designed and manufactured by the reproduction of double rotation plug of a reactor head in KALIMER-600. Hardware system which consists of a double rotating scanner, ultrasonic waveguide sensors, a high power ultrasonic pulser-receiver, a scanner driving module and a multi channel A/D board have been constructed. The functions of scanner control, image mapping and signal processing of Under-Sodium MultiVIEW program have been implemented by using a LabVIEW graphical programming language. The performance of Under-Sodium MultiVIEW program was verified by a double rotation C-scanning test in water.

기기냉각수 최저온도와 정지냉각계통 유량조절밸브 개도에 관한 설계분석

  • 김도현;이중섭;오종필;오광석
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.444-449
    • /
    • 1995
  • 한국형 표준 원자력발전소의 정지냉각운전시 최대냉각율은 75$^{\circ}$F/hr(41.7$^{\circ}C$/hr)로 기술사양서에 규정되어 있다. 정지냉각운전 냉각율에 가장 큰 영향을 미치는 2가지 중요한 변수는 정지냉각계통 열교환기를 지나는 원자로냉각재 유량과 기기냉각수의 온도다. 이중 열교환기를 지나는 원자로냉각재 유량은 butterfly형 정지냉각계통 유량조절밸브의 개도에 의하여 조절되는데 개도에 따른 throttle 능력이 중요한 인자다. 또 기기냉각수의 온도는 해수온도의 변화에 따라 편차가 발생하므로 유량조절밸브의 개도와 기기냉각수 온도의 상관관계에 따라 냉각능력이 달라진다. 본 논문에서는 현 울진 3&4호기 정지냉각계통 열 교환기 및 조절밸브 둥의 설비를 기준으로 기술사양서 상의 냉각율 75$^{\circ}$F/hr(41.7$^{\circ}C$/hr) 유지가 가능한 최저 기기냉각수의 온도를 찾아보았고, 아울러 기기냉각수의 온도와 조절밸브의 개도 사이의 관계를 조사하였다. 그 결과 현재의 울진 3&4호기 조절밸브를 최저개도로 조절할 때 약 57$^{\circ}$F(13.9$^{\circ}C$)의 기기냉각수가 공급되어도 냉각율 제한치를 넘지 않는 것으로 분석되었다. 한편, 최저조절가능 유량이 약 2000 gpm(7570 l/min)일 경우에는 낮은 기기냉각수가 공급될 경우 최대냉각율을 초과하므로 한 train을 정지시키고 한 train만으로 운전할 것을 고려하여야 할 것으로 보인다. 이 경우 최저 약 56.5$^{\circ}$F(13.6$^{\circ}C$)의 기기냉각수가 공급되어야 한다. 본 논문의 분석결과는 향후 기기설계사양서나 운전지침서 등에 반영되어 실제 발전소 설계 및 운전절차 수립에 기여할 수 있을 것으로 생각된다.공감대의 형성이 요구된다. 질적 측면에서는 공원 녹지의 기능성의 회복이라는 측면과 시대에 부합되는 새로운 기능 및 가치의 부여가 필요하며, 이를 위해서는 공원의 매력, 공원의 시설기능 증진, 녹지의 질의 향상 및 녹지 가치의 증진에 대한 다양한 시책이 요구된다. 구성적 측면에서는 공원녹지의 개별적 존재보다는 공원 녹지를 상호간 유기적인 계통을 확보하여 공원 녹지의 네트워크를 형성하여 도시 속의 산재된 고립된 섬으로서의 공원 녹지가 아닌 시민생활에 늘 가까이 있는 생활 속의 공원녹지로 재편되어야 한다. 이러한 정책의 의제는 양적 측면에서 보전(CONSERVATION)과 창출(CREATION), 질적 측면에서 쇄신(RENOVATION)과 복구(RESTORATION), 그리고 구성적 측면에서 공원 녹지의 연결(CONNECTION)과 시민 참여에 의한 운동(MOVEMENT)이라는 정책 개념의 구현을 통해 가능하다. 이러한 정책 개념과 의제를 가지고 서울시 공원 녹지 정책을 구체화시키기 위해서 푸르름의 새로운 탄생이라는 기치 아래 풍요로운 서울, 사랑 받는 공원, 생활 속의 녹지의 3대 목표, 공원 녹지의 보전, 잠재 공원 녹지의 창출, 공원의 활성화, 녹지의 복구, 경관 보전 및 복구, 공원 녹지의 네트워크, 도시 녹화의 7대 과제를 설정하고 미시설 공원 녹지 집행, 개발 사업시 공원 녹지의 확보, 환경 녹지의 총량 보호 관리, 도시 소공원 개발, 역사 문화 공원 조성, 하천 공간 복원, 공원 시설 기능 개선, 이용 프로그램 개발, 공원 관리 개선, 환경 피해 녹지의 회복, 도시 환경 림 조성, 녹지 기능 증진, 도시 자연 경관 보전, 공원 녹지체계 구성, 공원 녹지 공급 균형, 주변 환경 녹화, 가로 녹화의 17개 시책을 제안하였다. 이러한 정책사업의 원활한 추진을 위해서는 기존의 관주도의 일방적인 공원 녹지 행정이 아닌 시민의 참여를 통한 시민이 함께 하는 정 책 사업의 추진이 요구되며, 특히 민간 부문의

  • PDF