• Title/Summary/Keyword: 이종 복합재료

Search Result 169, Processing Time 0.029 seconds

Development of Hybrid Metals Coated Carbon Fibers for High-Efficient Electromagnetic Interference Shielding (고효율 전자파 차폐를 위한 이종금속 코팅 탄소섬유 개발)

  • Moon, Jai Joung;Park, Ok-Kyung;Lee, Joong Hee
    • Composites Research
    • /
    • v.33 no.4
    • /
    • pp.191-197
    • /
    • 2020
  • In this study, a hybrid metals such as copper (Cu) and nickel (Ni) coated carbon fibers (Ni-Cu/CFs) was prepared by wet laid method to develop a randomly oriented sheet material for high-efficiency electromagnetic interference shielding with the enhanced durability. The prepared sheet materials show a high electromagnetic interference shielding efficiency of 69.4 to 93.0 dB. In addition, the hybrid metals coated Ni-Cu/CFs sheets showed very high durability with harsh chemical/thermal environments due to the effective corrosive and mechanical resistances of Ni surface. In this context, the Ni-Cu/CF sheet possesses longer service life than the Cu/CF sheet, that is, 1.7 times longer.

Thermal, Frictional and Wear Behavior of Carbon Nanofiber/Poly(methyl methacrylate) Composites (탄소나노섬유/폴리(메틸 메타크릴레이트) 복합재료의 열적 및 마찰 마모 거동 연구)

  • Park Soo-Jin;Im Se-Hyuk;Lee Jae-Rock;Rhee John-M.
    • Polymer(Korea)
    • /
    • v.30 no.5
    • /
    • pp.385-390
    • /
    • 2006
  • In this work, the effect of carbon nanofiber (CNF) on thermal properties, and friction and wear behavior of CNF/PMMA composites were examined. While thermal properties of the composites were investigated with differential scanning calorimetry, thermograyimetric analyzer, and dynamic mechanical analyzer friction and wear behaviors were examined using a friction and wear tester. The glass transition temperature (Tg), integral procedural decomposition temperature (IPDT), storage modulus (E'), and tan ${\delta}$ appeared at higher temperatures with increasing CNF content, which were probably attributed to the presence of strong interactions between the carbonaceous fillers and the PMMA resins matrix. The wear loss in the composites decreased at 0.1 wt% CNF and then increased with 5-10 wt% CNF content. This was due to the existence of large aspect ratio CNF in PMMA which led to an alignment of PMMA chains and an increase of mechanical interlocking, resulting in the formation of crosslinked structures between CNF and PMMA in the composite.

Experimental Investigation of Riverbed Materials by Using the Characteristics of Ultrasonic Scour Sensor (하상변동 파악을 위한 초음파 세굴심 센서의 특성에 관한 실험적 연구)

  • Kim, Young-Bin;Yeo, Woon-Kwang;Lee, Jong-Kook
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1128-1132
    • /
    • 2005
  • 세굴을 일으키는 주요 원인은 와류의 작용에 의해서라고 알려져 있다. 와류를 일으키는 인자에는 흐름조건, 흐름의 변화, 하상재료, 그리고 교각의 형상 등이 있다. 그러나 세굴현상은 이들 인자 외에도 다른 원인들과 함께 복합적인 형태로 나타나기 때문에 수리 및 수치모형실험으로는 정확한 세굴을 규명하기 힘들다. 최근 국내에서는 보다 정확한 세굴을 관찰하기 위해 실시간 세굴모니터링이 이루어지고 있다. 이에 맞추어 실시간 세굴모니터링을 위해 초음파 세굴심 측정 센서가 개발되었는데, 이 센서는 수공구조물에 설치할 수 있어 평수 시뿐만 아니라 홍수 시에도 세굴의 변화를 관찰할 수 있다는 장점을 갖고 있다. 이 센서에 사용된 초음파는 반사면에 따라 반사파의 특성이 달라지는 성질을 갖고 있다. 본 연구에서는 이러한 초음파의 성질에 착안하여 초음파 세굴심센서를 이용한 하상재료 판단에 대한 실내실험을 실시하였다. 주로 하상에서 접할 수 있는 입자를 선정하여 실험을 실시하고 실험으로부터 획득된 초음파의 반사파자료를 이용하여 각 시료를 분류할 수 있는 정량적 근거를 제시하였다. 그리고 이 자료의 현장적용성을 검토하기 위하여 현장의 자료와 비교 및 분석하였다.

  • PDF

Study on the Oil Seal Application Using Polytetrafluoroethylene Composites (Polytetrafluoroethylene 복합재료를 이용한 오일씰 응용에 관한 연구)

  • Ha, Ki-Ryong;Lee, Jong-Cheol;Lee, Young-Seok
    • Elastomers and Composites
    • /
    • v.45 no.1
    • /
    • pp.32-39
    • /
    • 2010
  • The mechanical properties of PTFE 100%, PTFT 90% + carbon black 10%, PTFE 85% + glass fiber 15%, PTFE 80% + glass fiber 15% + molybdenum disulfide ($MoS_2$) 5%, PTFE 75% + glass fiber 25%, and PTFE 75% + carbon black 18% + graphite 7% composites were investigated in this study. The differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA) were used to examine the heat of fusion(${\Delta}H_f$) and thermal stability of the composites. Also, the wear surface and wear volume of PTFE lip seal were examined using the durability test. Wear surface was observed using scanning electron microscope (SEM). It was found that the hardness, wear resistance and durability were enhanced by adding glass fiber and molybdenum disulfide into pure PTFE, but tensile strength and elongation were decreased. According to the experimental results, the composite (PTFE + 15% glass fiber + 5% molybdenum disulfide) showed the best properties for applying to oil-seal among six types of PTFE composites.

Performance Evaluation of Multi-Friction Dampers for Seismic Retrofitting of Structures (구조물 내진보강을 위한 다중 마찰댐퍼의 성능 평가)

  • Kim, Sung-Bae;Kwon, Hyung-O;Lee, Jong-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.54-63
    • /
    • 2022
  • This paper is a study on the friction damper, which is one of the seismic reinforcement devices for structures. This study developed a damper by replacing the internal friction material with ultra high molecular weight polyethylene (UHMWPE), a type of composite material. In addition, this study applied a multi-friction method in which the internal structure where frictional force is generated is laminated in several layers. To verify the performance of the developed multi-friction damper, this study performed a characteristic analysis test for the basic physical properties, wear characteristics, and disc springs of the material. As a result of the wear test, the mass reduction rate of UHMWPE was 0.003%, which showed the best performance among the friction materials based on composite materials. Regarding the disc spring, this study secured the design basic data from the finite element analysis and experimental test results. Moreover, to confirm the quality stability of the developed multi-friction damper, this study performed an seismic load test on the damping device and the friction force change according to the torque value. The quality performance test result showed a linear frictional force change according to the torque value adjustment. As a result of the seismic load test, the allowable error of the friction damper was less than 15%, which is the standard required by the design standards, so it satisfies the requirements for seismic reinforcement devices.

Evaluation of the Change in Adhesion Strength of GFRP and CFRP with Carbon Nanotube Contents in Epoxy Adhesive with Moisture Change during Curing (에폭시 접착제의 탄소나노튜브 함량과 경화시 습도 변화에 따른 GFRP 및 CFRP의 접착강도 변화 평가)

  • Park, Hee-Woong;Kim, Jong-Hyun;Park, Joung-Man
    • Journal of Adhesion and Interface
    • /
    • v.23 no.1
    • /
    • pp.1-7
    • /
    • 2022
  • As the wind blades become larger, they tend to be made by mixing glass fiber and carbon fiber, and it is important to increase the properties of the adhesive which adheres the two materials. The physical properties of the adhesive vary depending on the content of the additive and curing conditions. In this study, the change in adhesion strength with the difference between the CNT (Carbon Nanotube) content of the epoxy adhesive and the humidity during curing was evaluated. GFRP and CFRP specimens were prepared and adhered using an epoxy adhesive, and to examine changes in characteristics with carbon nanotube contents and with the humidity during curing of the epoxy adhesive, adhesion strength was evaluated by dividing the difference between carbon nanotube content and humidity. To find out the change with the CNT contents, the intelaminar shear strength (ILSS) test was performed by dividing the contents of the CNT into 0, 0.1, 0.3, 0.5, and 1 wt%, and to confirm the change with the humidity conditions, the adhesive was cured by dividing the humidity by 20, 50, and 80%. From the result of the experiment, the adhesive force decreased when the content was excessively large, although the adhesive property was enhanced by adding CNT to the epoxy adhesive. In addition, it was confirmed that the adhesion characteristics were not changed as the humidity increased.

Shear bond strength of dental CAD-CAM hybrid restorative materials repaired with composite resin (치과용 복합레진으로 수리된 CAD-CAM hybrid 수복물의 전단결합강도)

  • Moon, Yun-Hee;Lee, Jonghyuk;Lee, Myung-Gu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.193-202
    • /
    • 2016
  • Purpose: This study was performed in order to assess the effect of the surface treatment methods and the use of bonding agent on the shear bond strength (SBS) between the aged CAD-CAM (computer aided design-computer aided manufacturing) hybrid materials and added composite resin. Materials and methods: LAVA Ultimate (LU) and VITA ENAMIC (VE) specimens were age treated by submerging in a $37^{\circ}C$ water bath filled with artificial saliva (Xerova solution) for 30 days. The surface was ground with #220 SiC paper then the specimens were divided into 9 groups according to the combination of the surface treatment (no treatment, grinding, air abrasion with aluminum oxide, HF acid) and bonding agents (no bonding, Adper Single Bond 2, Single Bond Universal). Each group had 10 specimens. Specimens were repaired (added) using composite resin (Filtek Z250), then all the specimens were stored for 7 days in room temperature distilled water. SBS was measured and the fractured surfaces were observed with a scanning electron microscope (SEM). One-way ANOVA and Scheffe test were used for statistical analysis (${\alpha}=.05$). Results: Mostly groups with bonding agent treatment showed higher SBS than groups without bonding agent. Among the groups without bonding agent the groups with aluminum oxide treatment showed higher SBS. However there was no significant difference between groups except two subgroups within LU group, which revealed a significant increase of SBS when Single Bond Universal was used on the ground LU specimen. Conclusion: The use of bonding agent when repairing an aged LAVA Ultimate restoration is recommended.

Damage Evaluation for High Pressure Fuel Tank by Analysis of AE Parameters (고압가스 연료탱크의 손상평가를 위한 음향방출 변수의 분석)

  • Jee, Hyun-Sup;Lee, Jong-O;Ju, No-Hoe;Lee, Jong-Kyu;So, Cheal-Ho
    • Composites Research
    • /
    • v.24 no.4
    • /
    • pp.36-40
    • /
    • 2011
  • This paper described analysis of acoustic emission parameter for the damage evaluation of type II vehicle fuel tank during fracture test. The observation of Kaiser effect, Felicity effect and creep effect is the means of damage evaluation method. It is possible to evaluate tank damage by the ratio of hit of over 60 dB and total hit. Damage mechanism of pressure tank can be estimated by analysis of average rise time, average amplitude.

Analysis of Acoustic Emission Signal for Vehicle CNG Tank Using Wideband Transducer (광대역 탐촉자를 이용한 자동차용 CNG 탱크의 음향방출 신호 분석)

  • Jee, Hyun-Sup;Lee, Jong-O;Ju, No-Hoe;So, Cheal-Ho;Lee, Jong-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.1
    • /
    • pp.1-6
    • /
    • 2012
  • This study is damage evaluation for CNG fuel tank during the burst test through the analysis of acoustic emission signals. Kaiser effect until the pressure 420 bar appears, but More than 420 bar by the creep effect appears significantly damaged vessels, and 480 bar pressure, the Kaiser effect of the rising phase was missing. Resonant transducer at 540 bar than 480 bar decreased activity such as energy and count Continually, but increased wideband transducer. In addition, through the rise time or frequency analysis of composite pressure vessels in order to observe the damage mechanisms wideband transducer is more effective than resonant transducer.

A Study on the Dielectric Properties and Mechanical characteristics of Composit Materials due to the High-Temper, and-Humidity (고온.다습하(高溫.多濕下)에서의 복합재료(複合材料)의 수요특성(特性) 및 기계적특성(機械的特性)에 관한 연구(硏究))

  • Lee, Jong-Ho;Lee, Kyu-Chul;Hwang, Yeong-Han;Kim, Hea-Dae;Lee, Tae-Sik;Park, Hong-Tae
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.750-752
    • /
    • 1992
  • The paper presents the effects of environment on glass-cloth/epoxy composites exposed to humid air were investigated. Tests were performed at temperature 40$^{\circ}C$ and 70$^{\circ}C$ with the materials exposed to humid air at 76% and 90% relative humidity. This investigation surveyed include (a) the moisture absorption and desorption characteristics of single and multi layered composites exposed to steady and to transient ambients, and (b) the resulting changes in tensile strength, dielectric strength, tan $\delta$ and $\varepsilon_{\tau}$ and the effects of environment on these parameters were assessed.

  • PDF