• Title/Summary/Keyword: 이완하중

Search Result 108, Processing Time 0.021 seconds

Analysis of the Creep Effect on the Dural-sac Occlusion in the Lumbar Spinal Motion Segment (크?현상이 요추 운동분절내의 척추경악 교합에 미치는 영향 해석)

  • 김영은;조성윤
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.6
    • /
    • pp.551-557
    • /
    • 2001
  • Occlusion of the dural-sac in the lumbar spine was quantitatively analysed using a one motion segment finite element mode developed in this study. Occlusion was quantified by calculating the cross sectional area chance of the dural-sac. In static analysis. less than 2 kN of compressive load could Produced no dural-sac occlusion. whereas 6kN load reduced cross sectional area by 4%, and produced 7.4%, 10.5% occlusion for additional 8 Nm. 10 Nm extension moments. respectively. In creep analysis, 10 Nm extension reduced cross sectional area and volume of the dural-sac by 6.9% and 2.4%, respectively. However. flexion moment could not produce any occlusion. The results suggested that occlusions may result mainly from slackening of ligamentum flavum and disc budging.

  • PDF

Fatigue Life Analysis and Prediction of 316L Stainless Steel Under Low Cycle Fatigue Loading (저사이클 피로하중을 받는 316L 스테인리스강의 피로수명 분석 및 예측)

  • Oh, Hyeong;Myung, NohJun;Choi, Nak-Sam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.12
    • /
    • pp.1027-1035
    • /
    • 2016
  • In this study, a strain-controlled fatigue test of widely-used 316L stainless steel with excellent corrosion resistance and mechanical properties was conducted, in order to assess its fatigue life. Low cycle fatigue behaviors were analyzed at room temperature, as a function of the strain amplitude and strain ratio. The material was hardened during the initial few cycles, and then was softened during the long post period, until failure occurred. The fatigue life decreased with increasing strain amplitude. Masing behavior in the hysteresis loop was shown under the low strain amplitude, whereas the high strain amplitude caused non-Masing behavior and reduced the mean stress. Low cycle fatigue life prediction based on the cyclic plastic energy dissipation theory, considering Masing and non-Masing effects, showed a good correlation with the experimental results.

Moment Resisting Behaviors of Railway Electric Pole Foundation According to Form Work Methods (거푸집 설치 방법에 따른 철도 전철주기초의 모멘트 저항 거동)

  • Lee, Su-Hyung;Lee, Seung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.411-417
    • /
    • 2013
  • The moment responses of electric pole foundations for a railroad were investigated using real-scale load tests. Large overturning moments were applied to two square rigid piles with a 1.1 m width and a 2.2 m embedded depth. Two different installation methods-with and without a form-were applied to evaluate the influence of the form work on the moment capacities of the foundations. The reduction of ground strength caused by the excavation without a form is more pronounce than the decrease of frictional strength due to the smooth concrete surface with a form. From the test results, it is found that the current design method which applies a proportional coefficient to consider the effect of a form work is not appropriate. When the normal and frictional stressed is considered separately, the effect of a form work can be estimated reasonably by reducing the friction angle between soil and foundation by 20%.

Structural Analysis for Constructing a Balloon Type Extracoporeal Membrane Oxygenator using CFD Analysis (CFD 해석을 이용한 Balloon형 인공심폐기 설계를 위한 구조적 해석)

  • Park, Young-Ran;Shim, Jeong-Yeon;Kim, Gi-Beum;Kim, Shang-Jin;Kang, Hyung-Sub;Kim, Jin-Shang;Kim, Min-Ho;Hong, Chul-Un;Kim, Seong-Jong
    • Korean Chemical Engineering Research
    • /
    • v.49 no.2
    • /
    • pp.238-243
    • /
    • 2011
  • In this study, we attempted a structural analysis in order to design a balloon type extracorporeal membrane oxygenator that can induce blood flow without using blood pumps for the purpose of complementing the weakness in the existing extracorporeal membrane oxygenator. To analyze the flow characteristic of the blood flow within the virtual model of extracorporeal membrane oxygenator, computational fluid dynamics(CFD) modeling method was used. The operating principle of this system is to make the surface of the extracorporeal membrane oxygenator keep contracting and dilating regularly by applying pressure load using a balloon, and the 'ime Function Value'that changes according to the time was applied by calculating a half cycle of sine waveform and a cycle of sine.waveform Under the assumption that the uni-directional blood flow could be induced if the balloon type extracorporeal membrane oxygenator was designed as per the method described above, we conducted a structural analysis accordingly. We measured and analyzed the velocity and pressure of blood flow at both inlet and outlet of the extracorporeal membrane oxygenator through CFD simulation. As a result of the modeling, it was confirmed that there was a flow in accord with the direction of the blood by the contraction/dilation. With CFD simulation, the characteristics of blood flow can be predicted in advance, so it is judged that this will be able to provide the most optimized design in producing an extracorporeal membrane oxygenator.

A Study on the Ground Improvement Effect with Grouting in Backside of Retaining Wall (흙막이 벽체 배면 그라우팅 시 지반보강 효과에 관한 연구)

  • Chu, Ickchan;Byun, Yoseph;Baek, Seungin;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.10
    • /
    • pp.77-83
    • /
    • 2012
  • Recently, excavations using propped walls were popularized in downtown due to reduced settlement of nearby structures. These excavations is induced strain to propped walls or settlement in near ground. In this study, the ground reinforcing effect was proven using NDS, which is an inorganic injection material. Injection tests were performed to compute optimum injection pressure and volume. Next, calibration chamber tests were performed by using computed injection pressure and volume, and wall behaviour was examined for overburden pressures of 50kPa and 150kPa. Ground reinforcing effect was shown when the material behind the propped wall was grouted. From test results, optimum injection pressure was 350kPa and the optimum volume was 10L considering economics. Calibration chamber test results show that after the material was grouted, the maximum settlement was reduced to 19% of the non-grouted condition. For overburden pressures of 50kPa and 150kPa behind the wall, the settlement of the wall increased by 58% and 57% when compared to the case of no overburden pressure.

A Study on the Evaluation of Expanded Metal Characteristics for Application Rockfall Facilities (낙석방지시설 적용을 위한 팽창메탈의 특성 연구)

  • Lee, Jong-In;Jung, Chun-Gyo;Kim, Sung-Ho;Hwang, Yeong-Cheol;Lee, Seung-Ho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.9
    • /
    • pp.13-20
    • /
    • 2011
  • There are many mountains in Korean Peninsula, and those used for the construction of roads and railways sectors are forming slopes. Slope collapse occurs with falling rocks and landslide because of the relaxation of the thawing rocks. The heavy rain in summer can also significantly contribute to the process, and abnormal climate change is much more influential than before. Therefore, rockfall-related accidents in rainy season are easily accessible in media every year. There has been a lot of research on application of strengthening compensation of the sections in order to minimize casualties and property damage. Rockfall Protection Net, however, has not been focused on much in the field yet. This study highlights the need of Rockfall Protection Net, since it can segregate the falling rocks inside the net relatively safely. Although there has been a little doubt about the effectiveness of rockfall protection facilities, it is obvious that relevant studies dealing with the solidity of the net are necessary for the rockfall protection net to be capable of supporting rockfall energies. As a result, Expanded metal strength is much more durable compared to the PVC coating net, and it is regarded as an excellent alternative material for the Rockfall Protection Net. In this study, the applicability of Expanded Metal as the alternative of Rockfall Protection Net is verified experimentally.

Two Dimensional Size Effect on the Compressive Strength of Composite Plates Considering Influence of an Anti-buckling Device (좌굴방지장치 영향을 고려한 복합재 적층판의 압축강도에 대한 이차원 크기 효과)

  • ;;C. Soutis
    • Composites Research
    • /
    • v.15 no.4
    • /
    • pp.23-31
    • /
    • 2002
  • The two dimensional size effect of specimen gauge section ($length{\;}{\times}{\;}width$) was investigated on the compressive behavior of a T300/924 $\textrm{[}45/-45/0/90\textrm{]}_{3s}$, carbon fiber-epoxy laminate. A modified ICSTM compression test fixture was used together with an anti-buckling device to test 3mm thick specimens with a $30mm{\;}{\times}{\;}30mm,{\;}50mm{\;}{\times}{\;}50mm,{\;}70mm{\;}{\times}{\;}70mm{\;}and{\;}90mm{\;}{\times}{\;}90mm$ gauge length by width section. In all cases failure was sudden and occurred mainly within the gauge length. Post failure examination suggests that $0^{\circ}$ fiber microbuckling is the critical damage mechanism that causes final failure. This is the matrix dominated failure mode and its triggering depends very much on initial fiber waviness. It is suggested that manufacturing process and quality may play a significant role in determining the compressive strength. When the anti-buckling device was used on specimens, it was showed that the compressive strength with the device was slightly greater than that without the device due to surface friction between the specimen and the device by pretoque in bolts of the device. In the analysis result on influence of the anti-buckling device using the finite element method, it was found that the compressive strength with the anti-buckling device by loaded bolts was about 7% higher than actual compressive strength. Additionally, compressive tests on specimen with an open hole were performed. The local stress concentration arising from the hole dominates the strength of the laminate rather than the stresses in the bulk of the material. It is observed that the remote failure stress decreases with increasing hole size and specimen width but is generally well above the value one might predict from the elastic stress concentration factor. This suggests that the material is not ideally brittle and some stress relief occurs around the hole. X-ray radiography reveals that damage in the form of fiber microbuckling and delamination initiates at the edge of the hole at approximately 80% of the failure load and extends stably under increasing load before becoming unstable at a critical length of 2-3mm (depends on specimen geometry). This damage growth and failure are analysed by a linear cohesive zone model. Using the independently measured laminate parameters of unnotched compressive strength and in-plane fracture toughness the model predicts successfully the notched strength as a function of hole size and width.

Autogenous Osteochondral Grafts for the Osteochondritis dissecans of the Knee (슬관절 박리성 골연골염에 대한 자가 골연골 이식술)

  • Hahn Sung-Ho;Yang Bo-Kyu;Yi Seung-Rim;Chun Shun-Wook;Seo Ji-Hyun
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.2
    • /
    • pp.142-148
    • /
    • 2003
  • Purpose: This study was performed to evaluate the operative results of osteochondritis dissecans treated with autogenous osteochondral grafts. Materials and Methods: From May 1990 to May 2000, this study included 13 patients, 17 cases treated with autogenous osteochondral grafts. The mean age of patients at operation was 23.4 years (range,20 to 32 years), all cases were men, and the mean follow-up was for 24.2 months (range, 12 to 110 months). Treatment was done by open or arthroscopic method using with Osteochondral Autograft Transfer System (OATS, Arthrex, USA). Results: Trauma history existed in all cases, and major trauma history in 7 cases, and minor repetitive in 10 cases. The involved sites of lesion were medial femoral condyle in 11 cases, in which extended classic site was 9 cases, inferocentral site was 2 cases, and lateral femoral condyle in 6 cases, in which all cases were inferocentral site. Magnetic resonance imaging (MRI) staging was stage II in 1 case, stage III in 11 cases, stage IV in 5 cases, and arthroscopic staging was stage III in 12 cases, stage IV in 5 cases. The mean lesion size was 3.19$cm^2$ (range, 1 to 8$cm^2$). Clinical results evaluated with grading system by Aichroth, were excellent in 3 cases (18$\%$), good in 11 cases (65$\%$), moderate in 2 cases (12V), poor in 1 case (5$\%$), which revealed satisfactory results in 83$\%$. Congruent articular surface, satisfactory articular thickness, and no loosening or subsidence was evidenced by follow-up MRI or arthroscopic finding. Conclusion: Autogenous osteochondral grafts can be an alternative treatment in lesions larger than 1$cm^2$ in size, unstable lesion, and involvement of weight-bearing articular surface. Long term follow-up will be needed for the final efficacy of autogenous osteochondral grafts.

  • PDF