• Title/Summary/Keyword: 이완시간

Search Result 375, Processing Time 0.025 seconds

Multi-Component Relaxation Study of Human Brain Using Relaxographic Analysis (Relaxographic 분석법을 이용한 뇌의 다중 자기이완특성에 관한 연구)

  • Yongmin Chang;Bong Soo Han;Bong Seok Kang;Kyungnyeo Jeon;Kyungsoo Bae;Yong-Sun Kim;Duk-Sik Kang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.2
    • /
    • pp.120-128
    • /
    • 2002
  • Purpose : To demonstrate that the relaxographic method provides additional information such as the distribution of relaxation times and water content which are poentially applicable to clinical medicine. Materials and Methods : First, the computer simulation was performed with the generated relaxation data to verify the accuracy and reliabilility of the relaxographic method (CONTINI). Secondly, in or der to see how well the CONTIN quantifies and resolves the two different ${T_1}$ environments, we calculated the oil to water peak area ratios and identified peak positions of ${T_1}-distribution$ curve of the phantom solutions, which consist of four centrifugal tubes (10 ml) filled with the compounds of 0, 10, 20, 30% of corn oil and distilled water, using CONTIN. Finally, inversion recovery MR images for a volunteer are acquired for each TI ranged from 40 to 1160 msec with TR/TE=2200/20 msec. From the 3 different ROIs (GM, WM, CSF), CONTIN analysis was performed to obtain the ${T_1}$-distribution curves, which gave peak positions and peak area of each ROI location. Results : The simulation result shows that the errors of peak positions were less in the higher peak (centered ${T_1}=600$ msec) than in the lower peak (centered ${T_1}=150$ msec) for all SNR but the errors of peak areas were larger in the higher peak than in the lower peak. The CONTIN analysis of the measured relaxation data of phantoms revealed two peaks between 20 and 60 msec and between 500 and 700 msec. The analysis gives the peak area ratio as oil 10%: oil 20%: oil 30% = 1:1.3:1.9, which is different from the exact ratio, 1:2:3. For human brain, in ROI 3 (CSF), only one component of -distributions was observed whereas in ROI 1(GM) and in ROI 2 (WM) we observed two components of ${T_1}-distribution$. For the WM and CSF there was great agreement between the observed ${T_1}-relaxation$ times and the reported values. Conclusion : we demonstrated that the relaxographic method provided additional information such as the distribution of relaxation times and water content, which were not available in the routine relaxometry and ${T_1}/{T_2}$ mapping techniques. In addition, these additional information provided by relaxographic analysis may have clinical importance.

  • PDF

Comparison of Proton T1 and T2 Relaxation Times of Cerebral Metabolites between 1.5T and 3.0T MRI using a Phantom (모형을 이용한 1.5T와 3.0T 자기공명에서의 뇌 대사물질들의 수소 T1과 T2 이완시간의 비교)

  • Kim, Ji-Hoon;Chang, Kee-Hyun;Song, In-Chan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.1
    • /
    • pp.20-26
    • /
    • 2008
  • Purpose : To present the T1 and T2 relaxation times of the major cerebral metabolites at 1.5T and 3.0T and compare those between 1.5T and 3.0T. Materials and Methods : Using the phantom containing N-acetyl aspartate (NAA), Choline (Cho), and Creatine (Cr) at both 1.5T and 3.0T MRI, the T1 relaxation times were calculated from the spectral data obtained with 5000 ms repetition time (TR), 20 ms echo time (TE), and 11 different mixing time (TM)s using STEAM (STimulated Echo-Acquisition Mode) method. The T2 relaxation times were obtained from the spectral data obtained with 3000 ms TR and 5 different TEs using PRESS (Point-RESolved Spectroscopy) method. The T1 and T2 relaxation times obtained at 1.5T were compared with those of 3.0T. Results : The T1 relaxation times of NAA were $2293\;{\pm}\;48\;ms$ at 1.5T and $2559\;{\pm}\;124\;ms$ at 3.0T (11.6% increase at 3.0T). The T1 relaxation times of Cho were $2540\;{\pm}\;57\;ms$ at 1.5T and $2644\;{\pm}\;76\;ms$ at 3.0T (4.1% increase at 3.0T). The T1 relaxation times of Cr were $2543\;{\pm}\;75\;ms$ at 1.5T and $2665\;{\pm}\;94\;ms$ at 3.0T (4.8% increase). The T2 relaxation times of NAA were $526\;{\pm}\;81\;ms$ at 1.5T and $468\;{\pm}\;74\;ms$ at 3.0T (11.0% decrease at 3.0T). The T2 relaxation times of Cho were $220\;{\pm}\;44ms$ at 1.5T and $182\;{\pm}\;35\;ms$ at 3.0T (17.3% decrease at 3.0T). The T2 relaxation times of Cr were $289\;{\pm}\;47\;ms$ at 1.5T and $275\;{\pm}\;57\;ms$ at 3.0T (4.8% decrease at 3.0T). Conclusion : The T1 relaxation times of the major cerebral metabolites (NAA, Cr, Cho), which were measured at the phantom, were 4.1%-11.6% longer at 3.0T than at 1.5T. The T2 relaxation times of them were 4.8%-17.3% shorter at 3.0T than at 1.5T. To optimize MR spectroscopy at 3.0T, TR should be lengthened and TE should be shortened.

  • PDF

Effects of Ancillary Actvities on Passenger Flows in Airport Terminals (공항청사의 부대시설이 여객동선에 미치는 영향)

  • 박창호
    • Journal of Korean Society of Transportation
    • /
    • v.2 no.1
    • /
    • pp.17-31
    • /
    • 1984
  • 공항의 용량측정은 수요군의 흐름에서 발생하는 소비시간분석을 요구하며 공항체계 의 대부분 시설에서는 흐름의 시간변위를 연속대기례에 의한 비효율적방법으로 예측할수도 있으나 청사내의 여객동선에 대해서는 여러 시설을 활용하려는 여객의 선택선호로 인하여 확률적 접근이 바람직하다. 본 논문은 공항의 청사내에서 부대시설에 의하여 소비되는 여객 의 이완시간을 예측하는 모형을 개발하였다. 총이완시간은 여객이 각 시설을 이용하는 확률 과 이용시간의 기대치에 대한 함수로서 계산되었으며 정상적인 여객의 동선이 이들 시설에 의하여 영향을 받을 경우에만 정의되도록 하였다. 이 이완도는 연속된 청사의 기능시설에 대한 여객동선분포의 입력과 출력을 설명하는데 쓰이게 되며 나아가서는 청사전반의 용량산 정을 위한 지표를 제공한다. 모형 검증을 위한 자료는 매표대와 보안검사대 사이의 부대시 설을 중심으로 수집되었으며 자료의 특성과 모형의 심요성이 논의되었다.

  • PDF

The Effect of Number of Echoes and Random Noise on T2 Relaxography : Development of 8-Echo CPMG (에코의 개수와 임의 잡음이 T2 이완영상의 구성에 미치는 영향연구 : 8에코 CPMG영상화 펄스열의 개발)

  • 정은기
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.67-72
    • /
    • 1998
  • The mapping of the spin-spin relaxation time T2 in pixel-by-pixel was suggested as a quantitative diagnostic tool in medicine. although the CPMG pulse sequence has been known to be the best pulse sequence for T2 measurement in physics NMR, the supplied pulse sequence by the manufacture of MRI system was able to obtain the maximum of 4 CPMG images. Eight or more images with different echo time TEs are required to construct a reliable T2 map, so that two or more acquisitions were required, which easily took more than 10 minutes. 4-echo CPMG imaging pulse sequence was modified to generate the maximum of 8 MR images with evenly spaced echo time TEs. In human MR imaging, since patients tend to move at least several pixels between the different acquisitions, 8-echo CPMG imaging sequence reduces the acquisition time and may remove any mis-regitration of each pixels signal for the fitting of T2. The resultant T2 maps using the theoretically simulated images and using the MR images of the human brain suggested that 8 echo CPMG sequence with short echo spacing such as 17-20 msec can give the reliable T2 map.

  • PDF

Determination of Electron Spin Relaxation Time of the Gadolinium-Chealted MRI Contrast Agents by Using an X-band EPR Technique (EPR을 통한 상자성 자기공명 조영제의 전자스핀 이완시간의 결정)

  • Sung-wook Hong;Yongmin Chang;Moon-jung Hwang;Il-su Rhee;Duk-Sik Kang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.1
    • /
    • pp.27-33
    • /
    • 2000
  • Purpose: To determine the electronic spin relaxation times, $T_{le}$, of three commercially available Gd-chelated MR contrast agents, Gd-DTPA, Gd-DTPA-BMA and Gd-DOTA, using Electron Paramagnetic Resonance(EPR) technique. Material and Methods: The paramagnetic MR contrast agents, Gd-DTFA(Magnevist) , Gd-DTFA-BMA(OMNISCAN) and Gd-DOTA(Dotarem), were used for this study, The EPR spectra of these contrast agents, which were prepared 2:1 methanol/water solution, were obtained at low temperatures, from $-160^{\circ}C~20^{\circ}C$. The glassy-state EPR spectra for these contrast agents were then fitted by the simulation spectra generated with different zero-field splitting (ZFS) parameters by a computer simulation program 'GEN', which generates the EPR powder spectrum using a given ZFS in $3{\times}3$ tensor. Finally, the spin relaxation times of the contrast agents were then determined from the $T_{2e}$, D, and E values of the best simulation spectra using the McLachlan's theory of average relaxation rate. Results: The electronic transverse spin relaxation times, $T_{2e}'s$, of Gd-DTPA, Gd-DTPA-BMA and Gd-DOTA were 0.113ns, 0.147ns and 1.81ns respectively. The g-values were 1.9737, 1.9735 and 1.9830 and the electronic spin relaxation times, $T_{1e}'s$, were 18.70ns, 33.40ns and $1.66{\mu}s$, respectively. Conclusion: The results of these studies reconfirm that the paramagnetic MR contrast agents with larger ZFS parameters should have shorter $T_{1e}'s$. Among three contrast agents used for this study, Gd-DOTA chelated with cyclic ligand structure shows better electronic property then the others with linear structure. Thus, it is concluded that the exact determination of ZFS parameters is the important factor in evaluating relaxation enhancement effect of the agents and in developing new contrast agents.

  • PDF

Relationship Between Pendulum Test Measurements of Post-Stroke Spasticity (뇌졸중 후 강직 평가를 위한 진자검사 측정값의 상관관계)

  • Kim, Yong-Wook
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.5
    • /
    • pp.325-332
    • /
    • 2010
  • The purpose of this study was to investigate the relationship between three quantitative measures of the pendulum test for spasticity in strokes: The relaxation index, the number of oscillations, and the duration of oscillations. Twenty-six stroke subjects participated in the study. Correlations among these measures of spasticity used Pearson's correlation coefficient. There was a statistically significant positive correlation between the relaxation index and number of oscillations in strokes (r=.881, p<.01). In addition there was significant positive correlation between the relaxation index and duration of oscillations (r=.896, p<.01), and between the number of oscillations and duration of oscillations (r=.938, p<.01). Thus, it is possible to use the number of oscillations and duration of oscillations as quantitative measures of spasticity, rather than the relaxation index, which is more complicated to obtain. According to the result of this study, the use of the simple and objective measurements of the number of oscillations and the duration of oscillations are required clinically in the quantitative measures of spasticity in the future.

Draw Resonance in Non-isothermal Spinning (비등온 방사공정에서의 Draw Resonance)

  • 현재천
    • The Korean Journal of Rheology
    • /
    • v.1 no.1
    • /
    • pp.71-79
    • /
    • 1989
  • 임계연신비로 특징지어지는 비등온 방사공정에서의 Draw Resonance 발생을, White 의 변형속도에 따라 변하는 물질의 이완시간 모델에 의한 convected Maxwell 유체의 방사 모형을 사용해서 연구했다. 임계연신비의 계산에는 다른 연구자들이 이용하는 통상의 복잡 한 수치계산인 eigenvalue 방법을 쓰지 않고 전파하는 동적 waves 에 근거한 간단한 Hyun 의 이론을 사용했다. 그 결과 Staton Number와 냉각 공기온도로서 나타내지는 방사공정의 냉각이 공정을 안정시킨다는 것이 밝혀졌다. 다시 말해서 연신점도가 변형후화인 유체이거 나 변형박화인 유체이거난 상관없이 항상 Stanton Number가 켜지거나 또는 냉각공기온도 가 낮아질수록(즉냉각효과가 커질 때) 임계연신비가 커지는 것이다(단변형박화 dvcp의 빌부 구간을 제외하고) 한편 Draw Resonacnce 에 미치는 냉각의 효과는 무차원 이완시간(a Weissenberg Number 혹은 a Deborah number)이 커질수록 작아진다는 것도 발견됐다. 이 것은 process Time 이 작아지면 열전달이 작아지기 때문이다. 이러한 내용들은 다른 연구 자들의 결과와도 잘 부합된다.

  • PDF

A Development of Traffic Queue Length Measuring Algorithm Using ILD(Inductive Loop Detector) Based on COSMOS (실시간 신호제어시스템의 대기길이 추정 알고리즘 개발)

  • seong ki-ju;Lee choul-ki;Jeong Jun-ha;Lee young-in;Park dae-hyun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.3 no.1 s.4
    • /
    • pp.85-96
    • /
    • 2004
  • The study begin with a basic concept, if the occupancy length of vehicle detector is directly proportional to the delay of vehicle. That is, it analogize vehicle's delay of a occupancy time. The results of a study was far superior in the estimation of a queue length. It is a very good points the operator is not necessary to optimize s1, s2, Thdoc. Thdoc(critical congestion degree) replaced 0.7 with 0.2 - 0.3. But, if vehicles have been experience in delay was not occupy vehicle detector, the study is in existence some problems. In conclusion, it is necessary that stretch queue detector or install paired queue detector. Also I want to be made steady progress a following study relation to this study, because it is required traffic signal control on congestion.

  • PDF

Investigation on the Effect of Laser Peening Variables on Welding Residual Stress Mitigation Using Dynamic Finite Element Analysis (동적 유한요소 해석을 통한 용접 잔류응력 이완에 미치는 레이저 피닝 변수의 영향 고찰)

  • Kim, Jong-Sung
    • Proceedings of the KWS Conference
    • /
    • 2010.05a
    • /
    • pp.84-92
    • /
    • 2010
  • 현재 가동 중인 몇몇 가압 경수로 원전 안전 1등급 설비의 이종금속 용접부는 일차수응력부식균열(PWSCC : Primary Stress Corrosion Cracking) 발생의 세가지 조건(민감 재질, 부식 환경, 인장응력)을 동시에 충족하고 있다. 즉, 이종금속 용접부는 PWSCC에 민감한 재질인 Alloy 600 계열 합금으로 제작 또는 용접되어 있으며 고온 수화학 부식 환경 하에 놓여있다. 아울러 오스테나이트 스테인리스 강의 예민화 예방을 위한 용접 후열처리 미실시로 높은 인장 용접 잔류응력이 작용하고 있다. 이러한 이종금속 용접부의 특성상 PWSCC가 발생할 잠재성이 있을 뿐만 아니라 국내외적으로 Alloy 600 계열 합금으로 제작 및 용접된 가압 경수로 원전 안전 1등급 설비의 이종금속 용접부에 실제 PWSCC가 발생된 사례들이 다수 보고되고 있다. 운전 환경 및 재질 변화 없이 PWSCC 발생을 예방하기 위해서는 인장 잔류응력을 이완시켜 낮은 인장 또는 압축 응력화하여야 한다. 이러한 인장 잔류응력 이완방법들로는 PWOL(Pre-emptive Weld Overlay), 레이저 피닝(Laser Peening), MSIP(Mechanical Stress Improvement Process), 워터 제트 피닝(Water Jet Peening), IHSI(Induction Heating Stress Improvement) 방법들이 있는데 공정 시간이 짧고 열 에너지 원이 필요 없으며 전체적인 소성 변형을 야기시키지 않는 레이저 피닝을 본 연구의 대상 방법으로 한다. 본 연구에서는 동적 유한요소 해석을 통해 용접 잔류응력을 이완시키는 레이저 피닝의 효과를 검증하고 용접 잔류응력에 미치는 레이저 피닝 변수의 영향을 고찰하고자 한다. 내부 보수용접이 수행된 경수로 원전 가압기 노즐 이종금속 용접부에 레이저 피닝을 적용한 경우에 대해 상용 유한요소 해석 프로그램인 ABAQUS를 이용하여 동적 유한요소해석을 수행한 결과, 고온 수화학 일차수와 접하는 Alloy 600 계열 합금 내면에서의 인장 잔류응력이 상당히 이완됨을 확인하였다. 또한, 최대충격 압력이 증가할수록, 충격압력 지속시간이 증가할수록, 레이저 스팟 직경이 증가할수록 내표면 인장 잔류응력 이완 정도는 감소하나 이완되는 영역의 깊이는 증가함을 알 수 있다. 또한, 레이저 피닝 방향이 잔류응력 이완에 미치는 영향은 미미함을 알 수 있다.

  • PDF

Studies on the ATpase Activity , Relaxing Activity and Calcium Uptake of Rabbit Skeletal Muscle Microsomes (골격근 microsome 의 ATMase 의 활성, 골이이오나용, 및 Ca 흡수작용에 관한 연구)

  • 하두봉
    • The Korean Journal of Zoology
    • /
    • v.10 no.2
    • /
    • pp.1-8
    • /
    • 1967
  • 토끼의 골격근 homogenate에서 23,000$\times$G, 60 분간의 원심분리와 얻은 근 microsome의 ATPase 활성, 근수축에 대한 이완작용, 및 Ca 의 흡수작용을 여러 가지 조건에서 측정하였다. ATPase 활성은 Ca++ Mg++ 양 이온의 존재에 의하여 활성화되며 , 5 mM Mg++ 의 존재하에서는 Ca++ 의 최적농도는 0.1mM이다. Oxalate의 존재하에서는 1 mM 의 Ca++ 이 최적농도이므로 oxalate의 작용은 불용성 Ca-oxalate의 작용은 불용성 Ca-oxalate를 microsome vesicle so 및 medium 내에 침전시켜 유리 Ca++ 농도를 저하시키는 것이라고 생각된다. Microsome의 이완작용은 조제후 120 시간까지 시간에 따라 감소되어 가나, 그이 ATPase 활성은 거의 변화가 없는 것으로 보아 Ca++ + Mg++ -의존성 ATPase 는 이완작용에는 직접 관련이 없는 것으로 해석된다. Oxalatedmlwhswo는 microsome의 Ca++ 흡수량을 현저히 증대시키며 동시에 흡수포화에 도달하는 시간을 지연시킨다. Oxalate의 이러한 효과도 Ca-oxalate의 형성에 기인하는 것으로 해석된다. Microsome 내에 축적되는 Ca 의 량은 ATP 농도가 커질수록 많아진다. 그러나 축적된 Ca 의 량과 ATP 농도사이에 화학정량론적 관계는 없는 것같다.

  • PDF