• Title/Summary/Keyword: 이온 검출

Search Result 638, Processing Time 0.025 seconds

Analysis on the Dosimetric Characteristics of Tangential Breast Intensity Modulated Radiotherapy (유방암의 접선 세기조절 방사선치료 선량 특성 분석)

  • Yoon, Mee Sun;Kim, Yong-Hyeob;Jeong, Jae-Uk;Nam, Taek-Keun;Ahn, Sung-Ja;Chung, Wong-Ki;Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.219-228
    • /
    • 2012
  • The tangential breast intensity modulated radiotherapy (T-B IMRT) technique, which uses the same tangential fields as conventional 3-dimensional conformal radiotherapy (3D-CRT) plans with physical wedges, was analyzed in terms of the calculated dose distribution feature and dosimetric accuracy of beam delivery during treatment. T-B IMRT plans were prepared for 15 patients with breast cancer who were already treated with conventional 3D-CRT. The homogeneity of the dose distribution to the target volume was improved, and the dose delivered to the normal tissues and critical organs was reduced compared with that in 3D-CRT plans. Quality assurance (QA) plans with the appropriate phantoms were used to analyze the dosimetric accuracy of T-B IMRT. An ionization chamber placed at the hole of an acrylic cylindrical phantom was used for the point dose measurement, and the mean error from the calculated dose was $0.7{\pm}1.4%$. The accuracy of the dose distribution was verified with a 2D diode detector array, and the mean pass rate calculated from the gamma evaluation was $97.3{\pm}2.9%$. We confirmed the advantages of a T-B IMRT in the dose distribution and verified the dosimetric accuracy from the QA performance which should still be regarded as an important process even in the simple technique as T-B IMRT in order to maintain a good quality.

The Study on the Relationship between Land Use and Groundwater Quality in the Rapidly Urbanized Area (도시화가 빠르게 진행된 지역의 토지이용과 지하수 수질과의 관계에 대한 연구)

  • An, Jung-Gi
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.1
    • /
    • pp.97-108
    • /
    • 2002
  • The use of land at the time of investigation of groundwater quality in the rapidly urbanized Bu-chon city is classified into 5 categories based on the change process of land use. The difference in groundwater quality according to the land use and its usage period is tested by non-parametric statistical procedures. The seven constituents of water quality with the highly frequent detection in the area for this study are used for the statistical test. The shallow groundwater quality within the areas of the same land use at the time of investigation varies significantly according to the period of land usage. The concentration of KMnO$_4$consumed and hardness is significantly higher in the old residential area (of more than 20 years old) than in the younger one (of less than 10 years old). The quality of the shallow groundwater is also significantly different among the three categories with the similar period of land usage (of more than 15 years old). The concentration of No$_3$-N, hardness and total solid is significantly higher in the residential area than in the agricultural one (namely, the area used as paddy fields 2 to 5 years ago). The median concentration of these constituents is 2.2 to 3.8 times higher in the residential area than in the agricultural one. The concentration of NO$_3$-N, KMnO$_4$, consumed and Cl is significantly higher in the industrial area than in the agricultural one. The median concentration of these constituents is 5.5 to 18 times higher in the industrial area than in the agricultural one. The concentration of KMnO$_4$consumed is significantly higher in the industrial area than in the residential area. The median concentration of these constituents is 12 times higher in the industrial area than in the residential one. The spatial distribution of shallow groundwater quality in the rapidly urbanized area is closely related to the period of land usage as well as the land use, which is presumed to be attributed to the difference in the concentration and leakage rate of the contaminants leaking from damaged sewer into shallow groundwater.

Characterization of Iron Oxides in Soils of Cheju Island by Mössbauer Spectroscopy and Chemical Techniques (Mössbauer 분광법(分光法)과 선택적(選擇的) 추출방법(抽出方法)에 의한 제주도(濟州道) 토양(土壤)에서의 산화철(酸化鐵)의 특성(特性) 구명(究明))

  • Kang, Dong-Woo;Kim, Doo-Chul;Ko, Jeong-Dae;Hong, Sung-Rak;Song, Kwan-Cheol
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.30 no.1
    • /
    • pp.3-15
    • /
    • 1997
  • Iron oxide compounds in 8 selected Cheju Island soil samples have been analized by X-ray fluorescence spectrometer(XRF), X-ray diffractometry(XRD), selected chemical techniques, and $M{\ddot{o}}ssbauer$ spectroscopy. The result of this analysis by XRF shows that the rate of quantity of $Fe_2O_3$ in 8 soil samples was from 8.03wt.%(Daejeong paddy soil) to 18.21wt.%(Songag soils). Songag, Heugag and Gueom soils were detected to have lower peaks of intensity of hematite by XRD. In addition, these soils were not detected to have hematite and goethite peaks. Ferrihydrite, which is a short-range-order mineral commonly present in volcanic ash soil, was not detected by XRD due to low concentration and/or poor cristallinity. Ferrihydrite contents estimated from Feo values were 8.8~35.2g/kg for volcanic ash soils and 0.85g/kg for the Daejeong soil. Most of the soil samples represented by the paramagnetic $Fe^{3+}$ doublet obtained from $M{\ddot{o}}ssbauer$ spectra at room temperature and 18K were considered to arise from the presence of ferrihydrite, superparamagnetic goethite, and silicate minerals. Also the paramagnetic $Fe^{2+}$ doublets are attributable to primary minerals such as olivine, illite, chlorite, augite, biotite, and hornblende. Goethite and hematite were identified as the dominant crystalline iron oxides in these soils from $M{\ddot{o}}ssbauer$ spectra obtained at room temperature and 18K. All the soil samples exhibited strong superparamagnetic relaxation. Collapse of the $M{\ddot{o}}ssbauer$ magnetic hyperfine splitting at room temperature was due to the small size(${\sim}180{\AA}$) of the oxide particles and/or Al-subsituted goethite.

  • PDF

Method Development for Determination of Chlorogenic Acid and Arbutin Contents in Fruits by UHPLC-MS/MS (UHPLC-MS/MS를 이용한 과일류 중 클로로젠산 및 알부틴 동시분석법 개발)

  • Choi, Young-Ju;Jeon, Jong-Sup;Kim, Woon-Ho;Jung, You-Jung;Ryu, Ji-Eun;Choi, Jong-Chul;Chae, Kyung-Suk;Lee, Jin-Hee;Do, Young-Sook;Park, Young-Bae;Yoon, Mi-Hye
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.5
    • /
    • pp.413-420
    • /
    • 2019
  • In this study, a sample preparation method and a simultaneous determination method by ultra-high performance liquid chromatography coupled with tandem mass spectrometry for 9 isomers of chlorogenic acid and arbutin in fruits were developed. The samples were extracted using 90% methanol (pH 3.0), with the solutions being shaken and then sonicated for 10 min each. After centrifugation at 4,000 rpm for 10 min, the extraction was concentrated under a vacuum at $40^{\circ}C$ using a vacuum evaporator. The residue was dissolved in 5 mL of 5% methanol and filtered through a $0.45{\mu}m$ membrane before UHPLC-MS/MS analysis. The separations were performed on a C18 column with gradient elution of water (containing 0.1% formic acid) and methanol (containing 0.1% formic acid). The specificity, linearity, limit of detection, limit of quantification, accuracy, and precision of the proposed methods were also evaluated.

Assessment on Accuracy of Stereotactic Body Radiation therapy (SBRT) using VERO (VERO system을 이용한 정위적 체부 방사선치료(SBRT)의 정확성 평가)

  • Lee, Wi Yong;Kim, Hyun Jin;Yun, Na Ri;Hong, Hyo Ji;Kim, Hong Il;Baek, Seung Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.17-24
    • /
    • 2019
  • Purpose: The present study aims to assess the level of coherency and the accuracy of Point dose of the Isocenter of VERO, a linear accelerator developed for the purpose of the Stereotactic Body Radiation Therapy(SBRT). Materials and Method: The study was conducted randomly with 10 treatment plans among SBRT patients in Kyungpook National University Chilgok Hospital, using VERO, a linear accelerator between June and December, 2018. In order to assess the equipment's power stability level, we measured the output constancy by using PTW-LinaCheck, an output detector. We also attempted to measure the level of accuracy of the equipment's Laser, kV(Kilo Voltage) imaging System, and MV(Mega Voltage) Beam by using Tofu Phantom(BrainLab, Germany) to assess the accuracy level of geometrical Isocenter. We conducted a comparative analysis to assess the accuracy level of the dose by using an acrylic Phantom($30{\times}30{\times}20cm$), a calibrated ion chamber CC-01(IBA Dosimetry), and an Electrometer(IBA, Dosimetry). Results: The output uniformity of VERO was calculated to be 0.66 %. As for geometrical Isocenter accuracy, we analyzed the error values of ball Isocenter of inner Phantom, and the results showed a maximum of 0.4 mm, a minimum of 0.0 mm, and an average of 0.28 mm on X-axis, and a maximum of -0.4 mm, a minimum of 0.0 mm, and an average of -0.24 mm on Y-axis. A comparison and evaluation of the treatment plan dose with the actual measured dose resulted in a maximum of 0.97 % and a minimum of 0.08 %. Conclusion: The equipment's average output dose was calculated to be 0.66 %, meeting the ${\pm}3%$ tolerance, which was considered as a much uniform fashion. As for the accuracy assessment of the geometric Isocenter, the results met the recommended criteria of ${\pm}1mm$ tolerance, affirming a high level of reproducibility of the patient's posture. The difference between the treatment plan dose and the actual measurement dose was calculated to be 0.52 % on average, significantly less than the 3 % tolerance, confirming that it obtained predicted does. The current study suggested that VERO equipment is suitable for SBRT, and would result in notable therapeutic effect.

Development of Method using LC-ESI-MS/MS and KASP for Identification of Gymnema sylvestre in Food (식품에서 당살초 판별을 위한 LC-ESI-MS/MS 분석법과 KASP 마커 개발)

  • Park, Boreum;Lee, Sun Hee;Eom, Kwonyong;Noh, Eunyoung;Moon Han, Kyoung;Hwang, Jinwoo;Kim, Hyungil;Baek, Sun Young
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.2
    • /
    • pp.46-54
    • /
    • 2022
  • Known for its effectiveness in weight loss and diabetes prevention, Gymnema sylvestre products can be found in the US, Japanese, and Indian markets. However, the recommended dosage or safety of these products has not yet been proven. Therefore, development of an analytical method for detecting the content of Gymnema sylvestre in food products is required. Accordingly, this study proposes an analysis method that can examine Gymnema sylvestre in food using LC-ESI-MS/MS and KASP (Kompetitive Allele-Specific PCR) markers. In LC-ESI-MS/MS, a simultaneous analysis method for gymnemic acid and deacylgymnemic acid was optimized using negative ionization mode, and its validation test was completed for solid and liquid samples. In addition, KASP markers were prepared by finding the specific SNP of G. sylvestre in ITS2 and matK through DNA barcodes. The two KASP markers returned positive FAM fluorescence result when combined with G. sylvestre, and this aspect was confirmed in raw G. sylvestre as well. The applicability of the method was tested on 21 different food and healthy functional products containing G. sylvestre purchased on the internet. As a result, although there was a difference in the ratios of gymnemic acid and deacylgymnemic acid in LC-ESI-MS/MS, the index component was detected in all 21 products samples. In the KASP analysis, 9 products returned positive FAM result, and the rest of the products were found to be containing G. sylvestre extract. This study is the first study to use the dual system of LC-ESI-MS/MS and KASP for the analysis of G. sylvestre. The study has confirmed that these two methods are applicable to the examine G. sylvestre content in food products.

Mineral Geochemistry of the Albite-Spodumene Pegmatite in the Boam Deposit, Uljin (울진 보암광산의 조장석-스포듀민 페그마타이트의 광물 지화학 조성 연구)

  • Park, Gyuseung;Park, Jung-Woo;Heo, Chul-Ho
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.35 no.3
    • /
    • pp.283-298
    • /
    • 2022
  • In this study, we investigated the mineral geochemistry of the albite-spodumene pegmatite, associated exogreisen, and wall rock from the Boam Li deposit, Wangpiri, Uljin, Gyeongsangbuk-do, South Korea. The paragenesis of the Boam Li deposit consists of two stages; the magmatic and endogreisen stages. In the magmatic stage, pegmatite dikes mainly composed of spodumene, albite, quartz, and K-feldspar intruded into the Janggun limestone formation. In the following endogreisen stage, the secondary fine-grained albite along with muscovite, apatite, beryl, CGM(columbite group mineral), microlite, and cassiterite were precipitated and partly replaced the magmatic stage minerals. Exogreisen composed of tourmaline, quartz, and muscovite develops along the contact between the pegmatite dike and wall rock. The Cs contents of beryl and muscovite and Ta/(Nb+Ta) ratio of CGM are higher in the endogreisen stage than the magmatic stage, suggesting the involvement of the more evolved melts in the greisenization than in the magmatic stage. Florine-rich and Cl-poor apatite infer that the parental magma is likely derived from metasedimentary rock (S-type granite). P2O5 contents of albite in the endogreisen stage are below the detection limit of EDS while those of albite in the magmatic stage are 0.28 wt.% on average. The lower P2O5 contents of the former albite can be attributed to apatite and microlite precipitation during the endogreisen stage. Calcium introduced from the adjacent Janggun formation may have induced apatite crystallization. The interaction between the pegmatite and Janggun limestone is consistent with the gradual increase in Ca and other divalent cations and decrease in Al from the core to the rim of tourmaline in the exogreisen.

Dose verification for Gated Volumetric Modulated Arc Therapy according to Respiratory period (호흡연동 용적변조 회전방사선치료에서 호흡주기에 따른 선량전달 정확성 검증)

  • Jeon, Soo Dong;Bae, Sun Myung;Yoon, In Ha;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.137-147
    • /
    • 2014
  • Purpose : The purpose of this study is to verify the accuracy of dose delivery according to the patient's breathing cycle in Gated Volumetric Modulated Arc Therapy Materials and Methods : TrueBeam STxTM(Varian Medical System, Palo Alto, CA) was used in this experiment. The Computed tomography(CT) images that were acquired with RANDO Phantom(Alderson Research Laboratories Inc. Stamford. CT, USA), using Computerized treatment planning system(Eclipse 10.0, Varian, USA), were used to create VMAT plans using 10MV FFF with 1500 cGy/fx (case 1, 2, 3) and 220 cGy/fx(case 4, 5, 6) of doserate of 1200 MU/min. The regular respiratory period of 1.5, 2.5, 3.5 and 4.5 sec and the patients respiratory period of 2.2 and 3.5 sec were reproduced with the $QUASAR^{TM}$ Respiratory Motion Phantom(Modus Medical Devices Inc), and it was set up to deliver radiation at the phase mode between the ranges of 30 to 70%. The results were measured at respective respiratory conditions by a 2-Dimensional ion chamber array detector(I'mRT Matrixx, IBA Dosimetry, Germany) and a MultiCube Phantom(IBA Dosimetry, Germany), and the Gamma pass rate(3 mm, 3%) were compared by the IMRT analysis program(OmniPro I'mRT system software Version 1.7b, IBA Dosimetry, Germany) Results : The gamma pass rates of Case 1, 2, 3, 4, 5 and 6 were the results of 100.0, 97.6, 98.1, 96.3, 93.0, 94.8% at a regular respiratory period of 1.5 sec and 98.8, 99.5, 97.5, 99.5, 98.3, 99.6% at 2.5 sec, 99.6, 96.6, 97.5, 99.2, 97.8, 99.1% at 3.5 sec and 99.4, 96.3, 97.2, 99.0, 98.0, 99.3% at 4.5 sec, respectively. When a patient's respiration was reproduced, 97.7, 95.4, 96.2, 98.9, 96.2, 98.4% at average respiratory period of 2.2 sec, and 97.3, 97.5, 96.8, 100.0, 99.3, 99.8% at 3.5 sec, respectively. Conclusion : The experiment showed clinically reliable results of a Gamma pass rate of 95% or more when 2.5 sec or more of a regular breathing period and the patient's breathing were reproduced. While it showed the results of 93.0% and 94.8% at a regular breathing period of 1.5 sec of Case 5 and 6, it could be confirmed that the accurate dose delivery could be possible on the most respiratory conditions because based on the results of 100 patients's respiratory period analysis as no one sustained a respiration of 1.5 sec. But, pretreatment dose verification should be precede because we can't exclude the possibility of error occurrence due to extremely short respiratory period, also a training at the simulation and careful monitoring are necessary for a patient to maintain stable breathing. Consequently, more reliable and accurate treatments can be administered.