• Title/Summary/Keyword: 이온크로마토그래피

Search Result 305, Processing Time 0.024 seconds

Virus Purification by Membrane Chromatography: A Review (멤브레인 크로마토그래피에 의한 바이러스 정제 : 리뷰)

  • Gayatri Bhamidipatia;Rajkumar Patel
    • Membrane Journal
    • /
    • v.34 no.2
    • /
    • pp.124-131
    • /
    • 2024
  • Viruses have various applications in the biopharmaceutical industry. They are used in pesticide production, production of vaccines, gene transfers, cancer therapeutics, and more. The downstream processing of viruses is an essential step for their biological and pharmaceutical applications. Among the various processes, the purification of viruses is critical. Membrane chromatography plays a vital role in this process. While ion exchange membrane chromatography is a primarily used method, it has various limitations regarding size exclusion and insufficient purification. Also, it cannot be applied to the rapidly changing strains of viruses such as influenza. This review examines various improved methods of membrane chromatography or alternatives. It focuses on purification, viral recovery rates, and scalability of the methods.

Purification of Lysozyme from Egg White by Multicycle Ion Exchange Chromatography (다중 이온교환크로마토그래피를 이용한 계란난백에서 리소짐의 분리)

  • 허윤석;김형원;김인호
    • KSBB Journal
    • /
    • v.18 no.2
    • /
    • pp.122-126
    • /
    • 2003
  • Multi-cycle chromatographic separation of Iysozyme from egg white was investigated. Multi-cycle chromatography was performed by repeated cycling(one cycle: resin equilibration, sample loading, washing, elution). Two types of cation exchange resins, Cellufine CM C-200 and Bio-rex 70, were used to determine the optimum condition for the separation of Iysozyme by multi-cycle chromatography. The resin was equilibrated in 20 mM Na-phosphate buffer(pH 7.0). Chromatograms of UV absorbance levels of every cycle were compared to confirm the eluting ability of Iysozyme in the two types of gel. Collected samples from eluting regions in every cycle were assayed by 15% SDS-PAGE.

Stability Evaluation on Measuring Water-soluble Chloride Anions from Iron Artifacts (철제유물의 수용성 염소이온 측정방법에 대한 안정성 평가)

  • Lee, Jae-Sung;Park, Hyung-Ho;Yu, Jae-Eun
    • Journal of Conservation Science
    • /
    • v.26 no.4
    • /
    • pp.397-406
    • /
    • 2010
  • The most ideal method to measure the water-soluble $Cl^-$ ion eluted from iron artifacts is conducting the analysis on desalting solution by Ion Chromatography. But most institutes related to cultural heritages use Cl meter by reason of lack of budget and experts. This study evaluated reliability and stability between Cl meter and Ion Chromatography by doing cross-validation with results from two methods to detect $Cl^-$ ion of desalting solution. From D.I water, extremely small quantities of $Cl^-$ ion was detected by the influence of remaining water-soluble $Cl^-$ ion at the electrode of Cl meter and water-soluble $Cl^-$ which remains in Sodium sesquicarbonate, components of reagent was detected as well. The first desalting solution had the most $Cl^-$ ions, $Cl^-$ ion slightly decreased from the second to the fourth desalting solution and tend to decrease again at the stage of dealkalified in D.I water. Each Cl meter has the standard deviation according to the measured numbers and the higher concentration of $Cl^-$ ion the desalting solution has, the wider the deviation is. But when the concentration of $Cl^-$ ion is low, it was stable to use Cl meter to detect the concentration of $Cl^-$ ion from iron artifacts because there is the small deviation, It is thought that conductivity meter method is not suitable for measuring $Cl^-$ ion, because the electrical conductivity of alkaline solution is too high to measure $Cl^-$ ion.

Effect of Eluent Electrolyte on the Retention Behavior of Structural Isomers of Phenols in HPLC. (HPLC 에서 페놀류의 구조 이성질체의 머무름 거동에 대한 전해질 용리액의 효과)

  • Lee, Seon Haeng;O, Dae Seop;Park, Gi Ho
    • Journal of the Korean Chemical Society
    • /
    • v.34 no.1
    • /
    • pp.44-50
    • /
    • 1990
  • The liquid chromatographic retention behavior of structural isomers of phenols was investigated by a change of the mobile phase properties. The retention behavior of structural isomer of phenols in reversed phase liquid chromatography was affected by eluent electrolyte added. It can be seen that this behavior is illustrated by a mechanism of Langmuir isotherm and ion exchange between phenolate and the reversed phase coated with ions. The retention behavior was represented as two different areas according to the concentration of the electrolytes. These areas can be explained as counter ion and co-ion effect, respectively. The maximum retention values were dependent not upon the kinds of organic modifier but upon the kinds of electrolyte.

  • PDF

Development of Open Tubular Capillary Columns for Ion Chromatography (이온 크로마토그래피용 Open Tubular Capillary 컬럼의 개발)

  • Pyo, Dong Jin;Kim, Ho Hyun
    • Journal of the Korean Chemical Society
    • /
    • v.45 no.2
    • /
    • pp.143-148
    • /
    • 2001
  • In this study, open tubular capillary columns for ion charomatography were developed to analyze trace amount of ions in samples. When small I,D. capillary column length is 1.0~5.0 m. The capillary columns were made using fused silica capillary(I.D:50㎛) and DMEOHA latex particles. The new conductivity cell and suppressor were also developed and made for capillary column ion chromatography. When several anions(fluoride, nitrite, nitale,chlorate,phosphte, sulfate) were analyzed using these capillary columns. reproducible and good chromatograms were obtained.

  • PDF

Analysis of Ammonia Gas Using Ion Chromatography (이온 크로마토그래피에 의한 기체상 암모니아의 분석법 확립)

  • Lee, Jong-Hae;Min, Byung-Hun;Jeon, Ryong;Kim, Jin-Seok;Kim, Yong-Du
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.366-367
    • /
    • 2003
  • 암모니아 가스는 무색의 기체이지만 자극성이 크면서 부식성이 있고 수용액이 알칼리성인 대표적인 악취물질이다. 보통의 경우는 굴뚝 등에서 배출가스의 형태로 대량 방출되기도 하지만 자연상태에서도 여러 가지 생물학적 또는 화학적 반응 등을 통하여 생성되므로, 일상적인 생활 공간에서도 쉽게 검출될 수 있는 물질이다. 대기 중 암모니아의 농도는 기체상 시료를 직접 분석하는 가스 크로마토그래피와 시료를 액체상으로 변환시킨 후 암모늄 양이온의 농도를 분광광도법이나 중화적정법으로 측정한다. (중략)

  • PDF

Ion-Pair Chromatography of Organic and Inorganic Anions (유기 및 무기음이온에 대한 이온쌍크로마토그래피)

  • Sam Woo Kang
    • Journal of the Korean Chemical Society
    • /
    • v.29 no.4
    • /
    • pp.365-371
    • /
    • 1985
  • A cationic dye, methylene blue $(MTB^+)$ was examined as a counter ion in the separation of organic and inorganic anions by ion-pair chromatography. Nonabsorbing anions could be indirectly detected by photometric detector with the assistance of MTB^+ in visible range (665nm). A mixture of anions was able to be separated with good base line resolution and high sensitivity. The capacity factors were also determined in various experimental conditions to study retention mechanism. The retention followed the ion-interaction model where the $MTB^+$ occupies a primary layer at the stationary phase while the analyte anion and other anions in the system compete for forming the secondary layer.

  • PDF

Ion-Pair Chromatography of Aromatic Carboxylic Acids on the Reversed-phase System (역상계에서 방향족 카르복시산류의 이온-쌍 크로마토그래피)

  • Hae-Beom Oh;Sam-Woo Kang;Seung-Seok Lee
    • Journal of the Korean Chemical Society
    • /
    • v.30 no.3
    • /
    • pp.312-319
    • /
    • 1986
  • Dodecyltrimethylammonium bromide (DTAB) was examined as a counter-ion in the investigation of capacity factor and separation of aromatic carboxylic acids on alkyl-modified silica (ODS) column as a stationary phase by ion-pair chromatography on reversed-phase system. The capacity factor of samples was influenced by the several factors such as a concentration of counter-ion as well as kinds and concentration of electrolyte, concentration of methanol in mobile phase and kinds and position of functional group in sample molecule. Some mixtures of samples were able to be separated under optimum condition.

  • PDF