• Title/Summary/Keyword: 이온에너지분포함수

Search Result 18, Processing Time 0.022 seconds

Particle Density Calculation for the Positive Column of a High Frequency Operated Fluorescent Lamp (고주파구동 형광램프 양광주의 입자밀도 계산)

  • 지철근;장우진;여인선;이진우
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.3 no.2
    • /
    • pp.51-55
    • /
    • 1989
  • 전원주파수 5-13[KHz]로 구동되는 형광램프(38mm 40W) 양광주 내의 수은의 여기원자 밀도를 시간과 반경방향에 대하여 계산하였다. 계산과정에서 수은의 에너지 준위는 기저 준위, 63P0, 63P1, 63P2와 이온화 준위가 고려되었으며, 전자의 에너지 분포함수는 2 Electron Group Model이 사용되었다. 계산결과는 일반적으로 사용하는 반경방향의 여기원자 밀도가 포물선 혹은 0차 Bessel 함수 형태라는 가정과 크게 다른 것으로 나타났다.

  • PDF

A Study on the Ultra-Low Energy Ion Implantation using Local Cell Damage Accumulation Model (국부 셀 격자 결함 모델을 사용한 극 저 에너지 이온 주입에 관한 연구)

  • Kwon, Oh-Keun;Kang, Jeong-Won;Hwang, Ho-Jung
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.7
    • /
    • pp.9-16
    • /
    • 1999
  • We have investigated effects of local damage accumulation for ultra-low energy As and B ion implant using highly efficient molecular dynamics(MD) scheme. We simulated ion implantation by MD simulation using recoil ion approximation (RIA) method and local cell damage accumulation (LCDA) model proposed in the paper. Local damage accumulation probability function consisted of deposited energy in a unit cell, implant dose rate, target material, projectile atom, and recoil event number. The simulated results were good agreement with the experimental and other simulated results. The MDRANGE results without damage accumulation were different from SIMS data in the tail region. We also simulated 2 dimensional dopant and damage profiles using the local damage accumulation model and recoil ion approximation method.

  • PDF

A Study on the electron energy diffusion function of the sulphur hexaflouride ($ SF_6$가스의 전자에너지 분포함수에 관한 연구)

  • 김상남;하성철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.95-101
    • /
    • 1999
  • The electron energy distributions function were analysed in sulIitur hexaflowide at E/N : 500~800(Td) for a case of non-equilibrium region in the nran electron energy. This papa- describes the electron transport characteristics in $ SF_6$ gas calculated for range of E/N values from 150~800(Td) by the Monte Carlo simulation and Boltzmann equation Irethod using a set of electron collision cross sectioos determined by the authors and the values of electron swarm parameters. The results gained that the value of an electron swarm parameter such as the electron drift velocity, the electron ionization or attachment coefficients, longitudinal and transverse diffusion coefficients agree with the experimental and theoretical for a range of E/N. The properties of electron avalanches in an electron energy non-equilibrium region.region.

  • PDF

대기압 유전격벽방전의 구동주파수 변화에 따른 전자가열 양상 변환에 대한 시뮬레이션 연구

  • Lee, Jeong-Yeol;Bae, Hyo-Won;Sim, Seung-Bo;Lee, Ho-Jun;Lee, Hae-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.251.2-251.2
    • /
    • 2014
  • 현재 의료 및 표면처리 분야에 많이 이용되고 있는 상온 대기압 플라즈마 중에서 유전체 격벽 방전(DBD) 장치는 비교적 간단한 구조를 가지며 sub-millimeters 사이즈에서도 매우 높은 플라즈마 밀도의 발생 및 유지가 가능하다. 그러나, 현재로선 이러한 Micro DBD의 특성을 실험적으로 분석하는 것은 장비의 한계가 있으므로, Particle-In-Cell 시뮬레이션을 이용하여 중요 플라즈마 변수들을 관찰하였다. 여기서 사용된 중요변수로는 13.56 MHz~600 MHz사이의 인가 주파수를 두었으며, 유전체 표면에서 양이온에 대한 이차전자 방출계수를 고려하였다, 또한 중성기체는 헬륨가스와 아르곤가스의 2가지 중성기체인 경우를 살펴보았다. 이러한 시뮬레이션을 통해 인가전압의 주기 대비 Ion transit time의 비율이 달라짐에 따라 플라즈마 쉬스의 특성변화와 함께 전자 에너지 확률함수(EEPF)의 특성이 달라진다는 것을 확인하고, 이러한 전자 가열 양상의 변화 원리에 대해서 분석하였다. 또한 주파수 비율 조정을 통한 전자온도, 파워, 효율 등을 조절하는 방법의 공학적 가치에 대해 의견을 제시하였다.

  • PDF

Dependence of Drain Induced Barrier Lowering for Doping Profile of Channel in Double Gate MOSFET (이중게이트 MOSFET에서 채널내 도핑분포에 대한 드레인유기장벽감소 의존성)

  • Jung, Hak-Kee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.9
    • /
    • pp.2000-2006
    • /
    • 2011
  • In this paper, the drain induced barrier lowering(DIBL) for doping distribution in the channel has been analyzed for double gate MOSFET(DGMOSFET). The DGMOSFET is extensively been studing because of adventages to be able to reduce the short channel effects(SCEs) to occur in convensional MOSFET. DIBL is SCE known as reduction of threshold voltage due to variation of energy band by high drain voltage. This DIBL has been analyzed for structural parameter and variation of channel doping profile for DGMOSFET. For this object, The analytical model of Poisson equation has been derived from Gaussian doping distribution for DGMOSFET. To verify potential and DIBL models based on this analytical Poisson's equation, the results have been compared with those of the numerical Poisson's equation, and DIBL for DGMOSFET has been investigated using this models.

Determination of Spectrum-Exposure Rate Conversion Factor for a Portable High Purity Germanium Detector (휴대형 고순도 게르마늄검출기에 대한 스펙트럼-조사선량율 변환연산자의 결정)

  • Kwak, Sang-Soo;Park, Chong-Mook;Ro, Seung-Gy
    • Journal of Radiation Protection and Research
    • /
    • v.13 no.2
    • /
    • pp.29-40
    • /
    • 1988
  • A spectrum-exposure rate conversion operator G(E) for a portable HPGe detector used for field environmental radiation survey was theoretically developed on the basis of a space distribution function of gamma flux emitted from a disk source and an areal efficiency of the detector. The radiation exposure rates measured using this G(E) and the portable HPGe. detector connected to a portable multichannel analyzer were compared with those measured by a 3' ${\phi}\;{\times}$3' NaI(Tl) scintillation detector with the reported G(E) and a pressurized ionization chamber. A comparison of the three results showed that the result obtained using the HPGe detector was lower than those determined using the NaI(Tl) detector and ionization chamber by 17% to 29%, The difference obtained is close to that reported in literature. The method developed here can be easily applicable to obtain a G(E) factor suitable to any detector for detecting the exposure rate of environmental gamma radiation, since the spectrum-exposure rate conversion operator can be calculated by a hand calculator.

  • PDF

Modeling of the dynamic behavior of a 12-V automotive lead-acid battery (12V 차량용 납축전지의 동적 거동 모델링)

  • Kim, Sung Tae;Lee, Jeong Bin;Kim, Ui Seong;Shin, Chee Burm
    • Journal of Energy Engineering
    • /
    • v.22 no.2
    • /
    • pp.175-183
    • /
    • 2013
  • For the optimal design of the vehicle electric system, it is important to have a reliable modeling tool to predict the dynamic behavior of the automotive battery. In this work, a one-dimensional modeling was carried-out to predict the dynamic behaviors of a 12-V automotive lead-acid battery. The model accounted for electrochemical kinetics and ionic mass transfer in a battery cell. In order to validate the modeling, modeling results were compared with the experiment data of the dynamic behaviors of the lead-acid batteries of two different capacities that were mounted on the automobiles manufactured by Hyundai Motor Company. The discharge behaviors were measured with various discharge rates of C/3, C/5, C/10, C/20 and combination. And dynamic behaviors of charge and discharge were measured. The voltage curves from the experiment and simulation were in good agreement. Based on the modeling, the distributions of the electrical potentials of the solid and solution phases, and the current density within the electrodes could be predicted as a function of charge and discharge time.

Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy (고 에너지 방사선치료에서 환자의 피폭선량 분포와 생식선의 차폐)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • High energy photon beams from medical linear accelerators produce large scattered radiation by various components of the treatment head, collimator and walls or objects in the treatment room including the patient. These scattered radiation do not provide therapeutic dose and are considered a hazard from the radiation safety perspective. Scattered dose of therapeutic high energy radiation beams are contributed significant unwanted dose to the patient. ICRP take the position that a dose of 500mGy may cause abortion at any stage of pregnancy and that radiation detriment to the fetus includes risk of mental retardation with a possible threshold in the dose response relationship around 100 mGy for the gestational period. The ICRP principle of as low as reasonably achievable (ALARA) was recommended for protection of occupation upon the linear no-threshold dose response hypothesis for cancer induction. We suggest this ALARA principle be applied to the fetus and testicle in therapeutic treatment. Radiation dose outside a photon treatment filed is mostly due to scattered photons. This scattered dose is a function of the distance from the beam edge, treatment geometry, primary photon energy, and depth in the patient. The need for effective shielding of the fetus and testicle is reinforced when young patients ate treated with external beam radiation therapy and then shielding designed to reduce the scattered photon dose to normal organs have to considered. Irradiation was performed in phantom using high energy photon beams produced by a Varian 2100C/D medical linear accelerator (Varian Oncology Systems, Palo Alto, CA) located at the Yonsei Cancer Center. The composite phantom used was comprised of a commercially available anthropomorphic Rando phantom (Phantom Laboratory Inc., Salem, YN) and a rectangular solid polystyrene phantom of dimensions $30cm{\times}30cm{\times}20cm$. the anthropomorphic Rando phantom represents an average man made from tissue equivalent materials that is transected into transverse 36 slices of 2.5cm thickness. Photon dose was measured using a Capintec PR-06C ionization chamber with Capintec 192 electrometer (Capintec Inc., Ramsey, NJ), TLD( VICTOREEN 5000. LiF) and film dosimetry V-Omat, Kodak). In case of fetus, the dosimeter was placed at a depth of loom in this phantom at 100cm source to axis distance and located centrally 15cm from the inferior edge of the $30cm{\times}30cm^2$ x-ray beam irradiating the Rando phantom chest wall. A acryl bridge of size $40cm{\times}40cm^2$ and a clear space of about 20 cm was fabricated and placed on top of the rectangular polystyrene phantom representing the abdomen of the patient. The leaf pot for testicle shielding was made as various shape, sizes, thickness and supporting stand. The scattered photon with and without shielding were measured at the representative position of the fetus and testicle. Measurement of radiation scattered dose outside fields and critical organs, like fetus position and testicle region, from chest or pelvic irradiation by large fie]d of high energy radiation beam was performed using an ionization chamber and film dosimetry. The scattered doses outside field were measured 5 - 10% of maximum doses in fields and exponentially decrease from field margins. The scattered photon dose received the fetus and testicle from thorax field irradiation was measured about 1 mGy/Gy of photon treatment dose. Shielding construction to reduce this scattered dose was investigated using lead sheet and blocks. Lead pot shield for testicle reduced the scatter dose under 10 mGy when photon beam of 60 Gy was irradiated in abdomen region. The scattered photon dose is reduced when the lead shield was used while the no significant reduction of scattered photon dose was observed and 2-3 mm lead sheets refuted the skin dose under 80% and almost electron contamination. The results indicate that it was possible to improve shielding to reduce scattered photon for fetus and testicle when a young patients were treated with a high energy photon beam.