• Title/Summary/Keyword: 이선형 모델

Search Result 2,176, Processing Time 0.039 seconds

Monte Carlo Study Using GEANT4 of Cyberknife Stereotactic Radiosurgery System (GEANT4를 이용한 정위적 사이버나이프 선량분포의 계산과 측정에 관한 연구)

  • Lee, Chung-Il;Shin, Jae-Won;Shin, Hun-Joo;Jung, Jae-Yong;Kim, Yon-Lae;Min, Jeong-Hwan;Hong, Seung-Woo;Chung, Su-Mi;Jung, Won-Gyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.192-200
    • /
    • 2010
  • Cyberknife with small field size is more difficult and complex for dosimetry compared with conventional radiotherapy due to electronic disequilibrium, steep dose gradients and spectrum change of photons and electrons. The purpose of this study demonstrate the usefulness of Geant4 as verification tool of measurement dose for delivering accurate dose by comparing measurement data using the diode detector with results by Geant4 simulation. The development of Monte Carlo Model for Cyberknife was done through the two-step process. In the first step, the treatment head was simulated and Bremsstrahlung spectrum was calculated. Secondly, percent depth dose (PDD) was calculated for six cones with different size, i.e., 5 mm, 10 mm, 20 mm, 30 mm, 50 mm and 60 mm in the model of water phantom. The relative output factor was calculated about 12 fields from 5 mm to 60 mm and then it compared with measurement data by the diode detector. The beam profiles and depth profiles were calculated about different six cones and about each depth of 1.5 cm, 10 cm and 20 cm, respectively. The results about PDD were shown the error the less than 2% which means acceptable in clinical setting. For comparison of relative output factors, the difference was less than 3% in the cones lager than 7.5 mm. However, there was the difference of 6.91% in the 5 mm cone. Although beam profiles were shown the difference less than 2% in the cones larger than 20 mm, there was the error less than 3.5% in the cones smaller than 20 mm. From results, we could demonstrate the usefulness of Geant4 as dose verification tool.

Postoperative Radiotherapy in Malignant Tumors of the Parotid Gland (이하선 악성종양의 수술 후 방사선 치료)

  • Chung Woong-Ki;Ahn Sung Ja;Nam Taek Ken;Chung Kyung-Ae;Nah Byung Sik
    • Radiation Oncology Journal
    • /
    • v.16 no.3
    • /
    • pp.251-258
    • /
    • 1998
  • Purpose : This study was performed to analyze the factors affecting local control in malignant tumors of the parotid gland treated with surgery and postoperative radiation. Materials and methods : Twenty-six patients were treated for malignant tumors of the parotid gland from 1986 to 1995 at Department of Therapeutic Radiology, Chonnam University Hospital. Age of the patients ranged from 14 to 72 years (median : 55 years). Histologically 10 patients of mucoepidermoid carcinoma, 7 of squamous cell carcinoma, 4 of acinic cell carcinoma, 4 of adenoid cystic carcinoma and 1 of adenocarcinoma were treated. Total parotidectomy was performd in 15 of 26 patients, superficial in 7, subtotal in 4. Facial nerve was sacrificed in 5 patients. Postoperatively 4 patients had residual disease, 4 had positive resection margin. Radiation was delivered through an ipsilateral wedged pair of photon in 11 patients. High energy electron beam was mixed with photon in 15 patients. Electron beam dose ranged from 900 cGy to 3800 cGy (median 1700 cGy). Total radiation dose ranged from 5000 cGy to 7560 cGy (median : 6020 cGy). Minimum follow-up period was 2 years. Local control and survival rate were calculated using Kaplan-Meier method. Generalized Wilcoxon test and Cox proportional hazard model were used to test factors affecting local control. Results : Five (19$\%$) of 26 patients had local recurrence. Five year local control rate was 77$\%$. Overall five year survival rate was 70$\%$. Sex, age, tumor size, surgical involvement of cervical lymph node, involvement of resection margin, surgical invasion of nerve, and total dose were analyzed as suggested factors affecting local control rate. Among them patients with tumor size less than 4 cm (p=0.002) and negative resection margin (p=0.011) were associated with better local control rates in univariate analysis. Multivariate analysis showed only tumor size factor is associated with local control rate (p=0.022). Conclusion : This study suggested that tumor size is important in local control of malignant tumors of parotid gland.

  • PDF

Modified Traditional Calibration Method of CRNP for Improving Soil Moisture Estimation (산악지형에서의 CRNP를 이용한 토양 수분 측정 개선을 위한 새로운 중성자 강도 교정 방법 검증 및 평가)

  • Cho, Seongkeun;Nguyen, Hoang Hai;Jeong, Jaehwan;Oh, Seungcheol;Choi, Minha
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.5_1
    • /
    • pp.665-679
    • /
    • 2019
  • Mesoscale soil moisture measurement from the promising Cosmic-Ray Neutron Probe (CRNP) is expected to bridge the gap between large scale microwave remote sensing and point-based in-situ soil moisture observations. Traditional calibration based on $N_0$ method is used to convert neutron intensity measured at the CRNP to field scale soil moisture. However, the static calibration parameter $N_0$ used in traditional technique is insufficient to quantify long term soil moisture variation and easily influenced by different time-variant factors, contributing to the high uncertainties in CRNP soil moisture product. Consequently, in this study, we proposed a modified traditional calibration method, so-called Dynamic-$N_0$ method, which take into account the temporal variation of $N_0$ to improve the CRNP based soil moisture estimation. In particular, a nonlinear regression method has been developed to directly estimate the time series of $N_0$ data from the corrected neutron intensity. The $N_0$ time series were then reapplied to generate the soil moisture. We evaluated the performance of Dynamic-$N_0$ method for soil moisture estimation compared with the traditional one by using a weighted in-situ soil moisture product. The results indicated that Dynamic-$N_0$ method outperformed the traditional calibration technique, where correlation coefficient increased from 0.70 to 0.72 and RMSE and bias reduced from 0.036 to 0.026 and -0.006 to $-0.001m^3m^{-3}$. Superior performance of the Dynamic-$N_0$ calibration method revealed that the temporal variability of $N_0$ was caused by hydrogen pools surrounding the CRNP. Although several uncertainty sources contributed to the variation of $N_0$ were not fully identified, this proposed calibration method gave a new insight to improve field scale soil moisture estimation from the CRNP.

Health-Promoting Behavior and Quality of Life among Community-Dwelling, Middle-Aged Women: A Comparative Study between Overweight and Normal-Weight Groups (지역사회 거주 중년 여성 집단에서 건강증진 행위와 삶의 질: 과체중 집단과 정상체중 집단 간 비교)

  • Yang, Hwa-Mi;Choo, Jina;Kim, Hye-Jin
    • Korean journal of health promotion
    • /
    • v.18 no.4
    • /
    • pp.159-168
    • /
    • 2018
  • Background: Strategically improving health-related quality of life (HRQOL) should be discussed among overweight middle-aged women who are vulnerable to low HRQOL. We examined firstly if overweight middle-aged women would have significantly lower levels of HRQOL and health-promoting behaviors than normal-weight middle-aged women, and to examine secondly if health-promoting behaviors would be significantly associated with generic and obesity-specific HRQOLs within the overweight middle-aged women. Methods: We conducted a cross-sectional, comparative study. Participants were 119 women aged 30-49 years who were recruited from a community in Seoul, South Korea; 63 women for the overweight group who were recruited from a baseline sample of the Community-Based Heart and Weight Management Trial, while 56 for the normal-weight group who were recruited separetely. Health Promoting Lifestyle Profile II (HPLP II), World Health Organization Quality of Life-brief version (WHOQOL-BREF) of a generic HRQOL measure, and Impact of Weight on Quality of Life-Lite (IWQOL-Lite) of an obesity-specific HRQOL measure were used. Results: Compared to the normal-weight group, the overweight group showed significantly lower scores of total WHOQOL-BREF as well as some HPLP II subscales including stress management (P=0.029). Among the HPLP II subscales, stress management was significantly and positively associated with total WHOQOL-BREF (${\beta}=1.58$, P=0.003) and self-esteem IWQOL-Lite (${\beta}=11.58$, P=0.034) among the overweight group. Conclusions: Among middle-aged overweight women, low levels of health-promoting behavior for stress management were shown, which should be strategically increased for improving their generic and obesity-specific HRQOLs.

Estimating Optimal Timber Production for the Economic and Public Functions of the National Forests in South Korea (국유림의 경제적·공익적 기능을 고려한 적정 목재생산량 추정)

  • Yujin Jeong;Younghwan Kim;Yoonseong Chang;Dooahn Kwak;Gihyun Park;Dayoung Kim;Hyungsik Jeong;Hee Han
    • Journal of Korean Society of Forest Science
    • /
    • v.112 no.4
    • /
    • pp.561-573
    • /
    • 2023
  • National forests have an advantage over private forests in terms of higher investment in capital, technology, and labor, allowing for more intensive management. As such, national forests are expected to serve not only as a strategic reserve of forest resources to address the long-term demand for timber but also to stably perform various essential forest functions demanded by society. However, most forest stands in the current national forests belong to the fourth age class or above, indicating an imminent timber harvesting period amid an imbalanced age class structure. Therefore, if timber harvesting is not conducted based on systematic management planning, it will become difficult to ensure the continuity of the national forests' diverse functions. This study was conducted to determine the optimal volume of timber production in the national forests to improve the age-class structure while sustainably maintaining their economic and public functions. To achieve this, the study first identified areas within the national forests suitable for timber production. Subsequently, a forest management planning model was developed using multi-objective linear programming, taking into account both the national forests' economic role and their public benefits. The findings suggest that approximately 488,000 hectares within the national forests are suitable for timber production. By focusing on management of these areas, it is possible to not only improve the age-class distribution but also to sustainably uphold the forests' public benefits. Furthermore, the potential volume of timber production from the national forests for the next 100 years would be around 2 million m3 per year, constituting about 44% of the annual domestic timber supply.

Evaluation of Ovary Dose for woman of Childbearing age Woman with Breast cancer in tomotherapy (가임기 여성의 유방암 토모치료 시 난소선량 평가비교)

  • Lee, Soo Hyeung;Park, Soo Yeun;Choi, Ji Min;Park, Ju Young;Kim, Jong Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.337-343
    • /
    • 2014
  • Purpose : The aim of this study is to evaluate unwanted scattered dose to ovary by scattering and leakage generated from treatment fields of Tomotherapy for childbearing woman with breast cancer. Materials and Methods : The radiation treatments plans for left breast cancer were established using Tomotherapy planning system (Tomotherapy, Inc, USA). They were generated by using helical and direct Tomotherapy methods for comparison. The CT images for the planning were scanned with 2.5 mm slice thickness using anthropomorphic phantom (Alderson-Rando phantom, The Phantom Laboratory, USA). The measurement points for the ovary dose were determined at the points laterally 30 cm apart from mid-point of treatment field of the pelvis. The measurements were repeated five times and averaged using glass dosimeters (1.5 mm diameter and 12 mm of length) equipped with low-energy correction filter. The measures dose values were also converted to Organ Equivalent Dose (OED) by the linear exponential dose-response model. Results : Scattered doses of ovary which were measured based on two methods of Tomo helical and Tomo direct showed average of $64.94{\pm}0.84mGy$ and $37.64{\pm}1.20mGy$ in left ovary part and average of $64.38{\pm}1.85mGy$ and $32.96{\pm}1.11mGy$ in right ovary part. This showed when executing Tomotherapy, measured scattered dose of Tomo Helical method which has relatively greater monitor units (MUs) and longer irradiation time are approximately 1.8 times higher than Tomo direct method. Conclusion : Scattered dose of left and right ovary of childbearing women is lower than ICRP recommended does which is not seriously worried level against the infertility and secondary cancer occurrence. However, as breast cancer occurrence ages become younger in the future and radiation therapy using high-precision image guidance equipment like Tomotherapy is developed, clinical follow-up studies about the ovary dose of childbearing women patients would be more required.

The effect of semantic categorization of episodic memory on encoding of subordinate details: An fMRI study (일화 기억의 의미적 범주화가 세부 기억의 부호화에 미치는 영향에 대한 자기공명영상 분석 연구)

  • Yi, Darren Sehjung;Han, Sanghoon
    • Korean Journal of Cognitive Science
    • /
    • v.28 no.4
    • /
    • pp.193-221
    • /
    • 2017
  • Grouping episodes into semantically related categories is necessary for better mnemonic structure. However, the effect of grouping on memory of subordinate details was not clearly understood. In an fMRI study, we tested whether attending superordinate during semantic association disrupts or enhances subordinate episodic details. In each cycle of the experiment, five cue words were presented sequentially with two related detail words placed underneath for each cue. Participants were asked whether they could imagine a category that includes the previously shown cue words in each cycle, and their confidence on retrieval was rated. Participants were asked to perform cued recall tests on presented detail words after the session. Behavioral data showed that reaction times for categorization tasks decreased and confidence levels increased in the third trial of each cycle, thus this trial was considered to be an important insight where a semantic category was believed to be successfully established. Critically, the accuracy of recalling detail words presented immediately prior to third trials was lower than those of followed trials, indicating that subordinate details were disrupted during categorization. General linear model analysis of the trial immediately prior to the completion of categorization, specifically the second trial, revealed significant activation in the temporal gyrus and inferior frontal gyrus, areas of semantic memory networks. Representative Similarity Analysis revealed that the activation patterns of the third trials were more consistent than those of the second trials in the temporal gyrus, inferior frontal gyrus, and hippocampus. Our research demonstrates that semantic grouping can cause memories of subordinate details to fade, suggesting that semantic retrieval during categorization affects the quality of related episodic memory.

Transmission Dose Estimation Algorithm for Tissue Deficit (조직 결손에 대한 투과선량 계산 알고리즘 보정)

  • Yun Hyong Geun;Chie Eui Kyu;Huh Soon Nyung;Lee Hyoung Koo;Woo Hong Gyun;Shin Kyo Chul;Ha Sung Whan
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.186-192
    • /
    • 2002
  • Purpose : Measurement of transmission dose is useful for in vivo dosimetry. In this study, previous algorithm for estimation of transmission dose was modified for use in cases with tissue deficit. Materials and Methods : The beam data was measured with flat solid phantom in various conditions of tissue deficit. New algorithm for correction of transmission dose for tissue deficit was developed by physical reasoning. The algorithm was tested in experimental settings with irregular contours mimicking breast cancer patients using multiple sheets of solid phantoms. Results : The correction algorithm for tissue deficit could accurately reflect the effect of tissue deficit with errors within ${\pm}1.0\%$ in most situations and within ${\pm}3.0\%$ in experimental settings with irregular contours mimicking breast cancer treatment set-up. Conclusion : Developed algorithm could accurately reflect the effect of tissue deficit and irregularly shaped body contour on transmission dosimetry.

Estimating the Yield of Marketable Potato of Mulch Culture using Climatic Elements (시기별 기상값 활용 피복재배 감자 상서수량 예측)

  • Lee, An-Soo;Choi, Seong-Jin;Jeon, Shin-Jae;Maeng, Jin-Hee;Kim, Jong-Hwan;Kim, In-Jong
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.61 no.1
    • /
    • pp.70-77
    • /
    • 2016
  • The object of this study was to evaluate the effects of climatic elements on potato yield and create a model for estimating the potato yield. We used 35 yield data of Sumi variety produced in mulching cultivation from 17 regions over 11 years. According to the results, some climatic elements showed significant level of correlation coefficient with marketable yield of potato. Totally 22 items of climatic elements appeared to be significant. Especially precipitation for 20 days after planting (Prec_1 & 2), relative humidity during 11~20 days after planting (RH_2), precipitation for 20 days before harvest (Prec_9 & 10), sunshine hours during 50~41 days before harvest (SH_6) and 20 days before harvest (SH_9 & 10), and days of rain during 10 days before harvest (DR_10) were highly significant in quadratic regression analysis. 22 items of predicted yield ($Y_i=aX_i{^2}+bX_i+c$) were induced from the 22 items of climatic elements (step 1). The correlations between the predicted yields and marketable yield were stepwised using SPSS, statistical program, and we selected a model (step 2), in which 4 items of independent variables ($Y_i$) were used. Subsequently the $Y_i$ were replaced with the equation in step 1, $aX_i{^2}+bX_i+c$. Finally we derived the model to predict the marketable yield of potato as below. $$Y=-336{\times}DR_-10^2+854{\times}DR_-10-0.422{\times}Prec_-9^2+43.3{\times}Prec_-9\\-0.0414{\times}RH_-2^2+46.2{\times}RH_-2-0.0102{\times}Prec_-2^2-7.00{\times}Prec_-2-10039$$.

Effect of Inhomogeneity correction for lung volume model in TPS (Lnug Volume을 모델로 한 방사선치료계획 시 불균질 조직 보정에 따른 효과)

  • Chung SeYoung;Lee SangRok;Kim YoungBum;Kwon YoungHo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.57-65
    • /
    • 2004
  • Introduction : The phantom that includes high density materials such as steel was custom-made to fix lung and bone in order to evaluation inhomogeneity correction at the time of conducting radiation therapy to treat lung cancer. Using this, values resulting from the inhomogeneous correction algorithm are compared on the 2 and 3 dimensional radiation therapy planning systems. Moreover, change in dose calculation was evaluated according to inhomogeneous by comparing with the actual measurement. Materials and Methods : As for the image acquisition, inhomogeneous correction phantom(Pig's vertebra, steel(8.21g/cm3), cork(0.23 g/cm3)) that was custom-made and the CT(Volume zoom, Siemens, Germany) were used. As for the radiation therapy planning system, Marks Plan(2D) and XiO(CMS, USA, 3D) were used. To compare with the measurement value, linear accelerator(CL/1800, Varian, USA) and ion chamber were used. Image, obtained from the CT was used to obtain point dose and dose distribution from the region of interest (ROI) while on the radiation therapy planning device. After measurement was conducted under the same conditions, value on the treatment planning device and measured value were subjected to comparison and analysis. And difference between the resulting for the evaluation on the use (or non-use) of inhomogeneity correction algorithm, and diverse inhomogeneity correction algorithm that is included in the radiation therapy planning device was compared as well. Results : As result of comparing the results of measurement value on the region of interest within the inhomogeneity correction phantom and the value that resulted from the homogeneous and inhomogeneous correction, gained from the therapy planning device, margin of error of the measurement value and inhomogeneous correction value at the location 1 of the lung showed $0.8\%$ on 2D and $0.5\%$ on 3D. Margin of error of the measurement value and inhomogeneous correction value at the location 1 of the steel showed $12\%$ on 2D and $5\%$ on 3D, however, it is possible to see that the value that is not correction and the margin of error of the measurement value stand at $16\%$ and $14\%$, respectively. Moreover, values of the 3D showed lower margin of error compared to 2D. Conclusion : Revision according to the density of tissue must be executed during radiation therapy planning. To ensure a more accurate planning, use of 3D planning system is recommended more so than the 2D Planning system to ensure a more accurate revision on the therapy plan. Moreover, 3D Planning system needs to select and use the most accurate and appropriate inhomogeneous correction algorithm through actual measurement. In addition, comparison and analysis through TLD or film dosimetry are needed.

  • PDF