• Title/Summary/Keyword: 이상 수질

Search Result 1,235, Processing Time 0.04 seconds

Changes of Epiphytic Algal Communities on Reed at the Shiwha Constructed Wetland in the Early Years of the Completion (시화인공습지 완공 초기에 갈대 부착조류 군집의 변화)

  • Kim, Han-Soon;Kim, Yong-Jae
    • Korean Journal of Ecology and Environment
    • /
    • v.39 no.3 s.117
    • /
    • pp.402-412
    • /
    • 2006
  • The Shihwa constructed wetland was established to treat the severely polluted water from Banwoul, Donghwa and Samhwa streams. This study was focused on investigating the dynamics of epiphytic algal communities on reed (Phragmites communis) planting area at 5 stations from October 2001 to June 2002. The concentration of total nitrogen and phosphorus of inlet stations from the streams were decreased after flowing through the wetland. However, the TN : TP ratios at all stations were slightly over 16 indicating that the total phosphorus may play some role as a limitation factor. Epiphytic algae on the reed were total 329 taxa which were composed of 295 species, 13 varieties, 3 forma and 18 unidentified species. The species numbers were recorded in the order of Chlorophyceae-Bacillariophyceae-Cyanophyceae-Euglenophyceae-Chrysophyceae. The relative percentage showed a seasonal variation from Cyanophyceae to Bacillariophyceae and to Chlorophyceae. The biomass of epiphytic algae measured by chlorophyll-a concentration ranged from 0.6 to $36.4\;{\mu}g\;cm^{-2}$. Dominant species were 16 taxa which were Lyngbya angusta of Cyanophyceae in the early investigation, and were changed to Stigeoclonium lubricum of Chlorophyceae, and Nitzschia palea of Bacillariophyceae etc. in the late. Species number, standing crops and chlorophyll-a concentrations of epiphytic algae showed higher values at the inlet stations than the stations after flowing through the wetland.

Residual Polychlorinated Biphenyls(PCBs) in the Sediment of the Kumho River (금호강(琴湖江) 저니토중(底泥土中) Polychlorinated Biphenyls(PCBs)의 잔류(殘留))

  • Kim, Jung-Ho;Moon, Chul-Ho
    • Korean Journal of Environmental Agriculture
    • /
    • v.14 no.3
    • /
    • pp.272-281
    • /
    • 1995
  • The residual Polychlorinated biphenyls(PCBs) in the sediment of the Kumho River basin were measured because the Nakdong River was considered to be affected by the environmental quality of Kumho River. PCBs in the sediment were chlorinated and converted into Decachlorinated biphenyl(DCB) which showed the single peak in the GC-ECD chromatogram. The detectable concentrations of PCBs was 0.5ng/g in the sediment. PCBs in the 21 sediment samples was of Kumho River located at 7.5km from conjunction of Nakdong River were not detected from 100 samples. 49% of samples was showed lower than 50ng/g, and 9% did more than 400ng/g. The mean of PCBs concentrations was 131ng/g. The means of COD and organic carbon were 14.5mg/g and 3.41%, respectively. The relationship between PCBs were concentration and the distance from conjunction with Nakdong River was not significant. The concentration of PCBs were varied with the depth of the sediment down to the 250cm depth. The concentrations of PCBs in the depth 0-20cm and 50-90cm were higher than the mean concentration of PCBs. Along the cross of the stream, the concentrations of PCBs were 142ng/g at the center and 126 and 131ng/g at the river sides.

  • PDF

The Distribution and Standing Crop of Phytoplankton in the Nearby Streams of Suwon Sewage Disposal Plant (수원 하수종말처리장 주변 수역의 식물플랑크톤의 분포와 현존량)

  • Lee, Ok-Min
    • Korean Journal of Environmental Biology
    • /
    • v.19 no.4
    • /
    • pp.282-291
    • /
    • 2001
  • The distribution and standing crop of phytoplankton were investigated seasonally at 6 stations in the nearby streams of Suwon sewage disposal plant. It turned out to be total of 176 taxa, and classified as 4 phylums, 4 classes, 11 orders, 6 suborders, 22 families, 54 genera, 155 species, 20 varieties and 1 form by Engler's classification system. Among 176 taxa, 22 including Microcystis Aphanizomenon flos-aquae were identified as indicators of water pollution. Standing crops of all stations investigated appeared to be relatively high as in other streams through the center of the city, such as Kyoungan-chon of Youngin-si and Gulpo-chon of Buchon-si. In station 1,2,4 and 6, the highest number of standing crop were shown in summer, while in station 3 and 5, it was high in winter. Based on the present study upon the distribution and standing crop of phytoplankton, it is regarded as the state of the eutrophication in the nearby streams of Suwon sewage disposal plant.

  • PDF

Ecology of Vibrio cholerae non-O1 and Vibrio mimicus in Estuary of Kum River, Korea (금강 하구의 Vibrio cholerae non-O1과 Vibrio mimicus의 선택)

  • CHANG Soo-Hyun;SONG Dae-Jin;YANG Song-Ju;SHIN Il-Shik;KIM Young-Man
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.28 no.1
    • /
    • pp.15-22
    • /
    • 1995
  • To study ecological properties of Vibrio cholerae non-Ol and Vibrio mimicus which have been described as new food poisoning bacteria recently, the influence of factors such as temperature, salinity, pH and chemical oxygen demand (COD) on detection rate and density of these bacteria were evaluated. Fifty four seawater samples and 49 bottom deposit samples from estuary of Kum river from March 26th, 1993 to February 22nd, 1994 were used for this study. The detection rate of V cholerae non-O1 were $16.7\%$ for seawater and $10.2\%$ for bottom deposit, respertively. The total detertion rate of V. cholerae non-O1 $(11.7\%)$ was a little higher than V mimicus $(10.7\%)$. Both V choierae non-O1 and V. mimicus were mainly detected in estuary water of which showed temperature $24^{\circ}C$ above and salinity $10\%o$ below. These bacteria were also detected in bottom deposit on January when the water temperature was $3.5^{\circ}C$. From these results, we supposed that temperature, salinity and organic material were important factors to growth of V. cholerae non-O1 and V. mimicus. V cholerae non-O1 might be grown better than V. mimicus under the fluctuating aquatic environmental condition such as salinity.

  • PDF

Study on Biochemical Pollutant Markers for Diagnosis of Marine Pollution IV. Changes in Lipid Components of Flounder (Pleuronichthys cornutus) in the Yellow Sea (해양오염의 진단을 위한 생화학적 오염지표에 관한 연구 IV. 황해산 도다리 (Pleuronichthys cornutus)의 지질성분의 변화)

  • CHOI Jin-Ho;KIM Dong-Woo;PARK Chung-Kil;KIM Jae-Il;YANG Dong-Beom
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.4
    • /
    • pp.601-607
    • /
    • 1997
  • This study was designed to investigate the biochemical pollutant marker for diagnosis of marine pollutions by the changes in lipid components of the flounder (Pleuronichthys cornutus) in the Yellow Sea of Korea. Hemoglobin levels in serum of wild flounders in the yellow Sea were significantly lower $(15\~30\%)$ than those of wild flounder in Pohang (control) of the East Sea. Triglyceride (TG) contents in serum of wild flounders in the Yellow Sea were higher $(15\~50\%)$ than those of wild flounder in Pohang. Total and low density lipoprotein (LDL)-cholesterol contents in serum of flounders in the Yellow Sea were significantly higher $(20\~25\%\;and\;15\~35\%,\;respectively)$ than those of wild flounder in Pohang. Atherogenic index (Al) in serum of wild flounders in the Yellow Sea were significantly higher $(10\~60\%)$ than these of wild flounder in Pohang but T-Chol/PL ratios showed almost no change in serum of flounders in the Yellow Sea we examined. These results suggest that near-coastal water as well as neritic water of the Yellow Sea might be affected by pollutant input.

  • PDF

Geochemical Significance of $^{14}C$ Age from the Dongrae Hot Spring Water (동래온천수의 $^{14}C$ 연대의 지구과학적 의의)

  • Lee, Seung-Gu;Nakamura, Toshio;Kim, Tong-Kwon;Ohta, Tomoko;Kim, Hyoung-Chan;Lee, Tae-Jong
    • Economic and Environmental Geology
    • /
    • v.42 no.6
    • /
    • pp.541-548
    • /
    • 2009
  • The Dongrae thermal water area located at the southeastern marginal part of the Korean Peninsula is one of the oldest hot springs in Korea. The Dongrae thermal water shows Na-Cl type of water chemistry, whereas the shallow cold groundwater is Ca(-Na)-$HCO_3$ type. In this paper, we discuss the age of the Dongrae hot spring, i.e. groundwater cycle among meteoric water-surface water-shallow groundwater-hot spring water. The $^{87}Sr/^{86}Sr$ ratios of the thermal water in Dongrae area range from 0.705663 to 0.705688 and are lower than those of groundwater, surface water and rain water as well as aquifer bearing granite. These Sr isotopic signatures in the Dongrae thermal water indicate that the circulation rate between thermal water and current meteoric water including groundwater, surface water and rain water in the Dongrae area should be very slow. The $^{14}C$ age of the Dongrae hot spring water range from $1,271{\pm}36$ BP(before present) to $2,467{\pm}36$ BP whereas that of the shallow groundwater is $-495{\pm}33$ BP. This suggests that the period of groundwater cycle among meteoric water, surface water, shallow groundwater and hot spring should be more than 1,270 years. Then, it also indicates that the present Dongrae hot spring may be a mixed water between the old thermal water heated for at least 1,270 years and the present shallow cold groundwater.

Influence of Dispersed and Anaerobic Bacteria in Aerobic Paper-making Wastewater Treatment (호기적 제지폐수 처리공정중에의 분산 혐기성 미생물의 영향)

  • 박종현;김선영;한완택
    • Microbiology and Biotechnology Letters
    • /
    • v.28 no.3
    • /
    • pp.180-184
    • /
    • 2000
  • Tn order to be helpful to control dispersed microorganisms for stabLlization of wastewater treatment in a paper-makillg process, dominant strains were isolated aerobically and anaerobically. and identified and physiological characteristics were also analyzed. Pseudomonas carboxydohydrogena, Cardiobacten'm hominis, lvIicrococcus lylae, XanfomonCls campestris p" juglandis, Micrococcus diversus, and Comamonas terrigencl as aerobic dominants, and Streptococcus bovis and Prevotella buccae as anaerobIc dominants were identified fi'om the supernatent of the primary settling tank. It seemed that microflora in the treatment process would consist of many kinds of microorganisms, whose dominant would change easily according to environmental conditions, They all grew well at $37^{\circ}C$ and at different initial medium pH's. Especially, some of them required sulfate ion for their growth, which came from a chemical coagulant of aluminium sulfate in the primary settling tank. Interestingly. many anaerobes grew well even in the aerobic wastewater treatment process and seemed to have some functions. Population of anaerobes increased three times in the supematant of primary settling tank and ten times in Lhe bottom sludge of primary settling tank than in the prime wastewater. Therefore, these anaerobes contributed to the producH tion of offensive gases, which would make some microorganisms not precLpitate and be buoyant.

  • PDF

Application of Electrochemical Technology for Reusing Biologically Treated Water (생물학적 처리수 재이용을 위한 전기화학 기술의 적용)

  • Kang, Gu-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.4
    • /
    • pp.453-458
    • /
    • 2008
  • Laboratory experiments were conducted to investigate disinfection as well as removal of color and residual organics from reclaimed municipal wastewater by electrochemical processes with Nb/Pt anode installed. RNO was rapidly bleached by OH$\cdot$ and the second order rate constants of RNO removal were $\frac{0.223l}{mg{\cdot}min}$, $\frac{1.679l}{mg{\cdot}min}$ and $\frac{2.322l}{mg{\cdot}min}$ with for 5 A, 10 A, and 15 A, respectively, with r$^2$ of > 96%. In batch electrochemical processes, after 15 min at currency of 15 A and initial pH of 5, 7,5 and 9, COD$_{Mn}$ was below 4 mg/L, color unit below 5 degree and general bacteria was not detected, the concentration of which are suitable for drinking water regulation. In the continuous electrochemical process, with HRT of 3.7$\sim$49.2 min, free chlorine were 0.2$\sim$0.7 mg/L, general bacteria was not detected, color unit below 5 degree and THMs was 0.017 mg/L. Therefore, electrochemical process with Nb/Pt anode was employed satisfactory to meet for reusing biologically treated water as well as disinfection.

Treatment Efficiency of Pollutants in Constructed Wetlands under Different Hydroponic Wastewater Injection Methods and Characteristic of Filter Media (시설하우스 폐양액 주입방법 및 여재 특성에 따른 인공습지에서 수질오염물질의 처리효율)

  • Seo, Dong-Cheol;Park, Jong-Hwan;Cheon, Yeong-Seok;Park, Seong-Kyu;Kim, Ah-Reum;Lee, Won-Gyu;Lee, Sang-Won;Lee, Seong-Tae;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.29 no.2
    • /
    • pp.146-151
    • /
    • 2010
  • In order to improve T-N and T-P removal in HF (horizontal flow)-HF hybrid constructed wetlands by natural purification method for treating the hydroponic wastewater in greenhouses, the efficiency of water treatment as affected by the injection method of hydroponic wastewater, the addition of special filter media, the particle size of filter media, and the injection ratio of hydroponic wastewater in $1^{st}$ HF and $2^{nd}$ HF beds were investigated in small-scale HF-HF hydroponic wastewater treatment apparatus. Removal rate of T-P in the water in HF-HF hydroponic wastewater treatment apparatus with calcite as affected by addition method of special filter media was higher than that in HF-HF hydroponic wastewater treatment apparatus with other filter media. Removal rate of BOD, COD, SS, T-N and T-P in the water in mixed filter media with calcite were 86, 84, 87, 50 and 97%, respectively. Removals of pollutants except for T-P in the water were slightly different. Therefore, it should be considered that the removal rate of T-P was good for calcite in HF-HF hydroponic wastewater treatment apparatus. To improve T-N and T-P removal, the optimum particle size of filter media was 1.2 mm, and the optimum injection ratio ($1^{st}$ HF bed : $2^{nd}$ HF bed) of hydroponic wastewater was 60:40.

Changes in Water Quality and Bacterial Compositions in Culture Water of an Ozonated Flounder Farm (오존 처리한 넙치 양식장 사육수의 수질과 미생물 변동)

  • Park, Seongdeok;Kim, You Hee;Park, Jeonghwan;Kim, Pyong-Kih
    • Korean Journal of Environmental Biology
    • /
    • v.36 no.1
    • /
    • pp.90-97
    • /
    • 2018
  • This study assessed the effect of ozone to control pathogenic bacteria in inlet water flowing to flounder farms, establishing operational parameters of ozonation at seawater conditions. Hydraulic retention time in a reaction pipeline after ozonation was fixed at 3 minutes in a flow through system. Concentrations of total residual oxidant (TRO) by ozonation were measured according to different ozonation intensities. The oxidant reduction potential (ORP), which is indirect but enables real-time measurement, was measured in relation to TRO values. TRO values were $0.01{\pm}0.01mg\;L^{-1}$ at an ORP range of 320-410 mV, $0.07{\pm}0.02mg\;L^{-1}$ at 600 mV, and $0.16{\pm}0.03mg\;L^{-1}$ at 700 mV. A heterotrophic marine bacteria colony was reduced by 80.6-97.9%, showing the suppression effect of ozonation on total bacteria in inlet water. At an ORP range of 400-500 mV, colonies of heterotrophic marine bacteria, Vibrio spp., and gram negative bacteria were significantly reduced in outlet water from a culture tank with ongrowing flounder (230 g) at a stocking density of $8kg\;m^{-2}$. Especially, Vibrio spp. and gram negative bacteria were seldom found at 400-500 mV. The daily feeding rate was from over 0.7% to total body weight at 300-500 mV, showing better performance than that in the control. The pathogenic bacteria entering the flounder farm were effectively removed when the ORP range to 400 mV or less.