• Title/Summary/Keyword: 이상수

Search Result 51,954, Processing Time 0.088 seconds

Correction of Single Thoracic Adolescent Idiopathic Scoliosis Using Pedicle Screw Instrumentation: Comparison of Stainless Steel to Titanium Alloy Instruments (척추경 나사못 고정술을 이용한 단일 흉추 청소년기 특발성 척추 측만증의 치료: 스테인리스강과 티타늄 합금 기기의 비교)

  • Kim, Sung-Soo;Lim, Dong-Ju;Kim, Jung-Hoon;Choi, Byung-Wan;Kim, Hwi-Young;Lee, Jun-Seok
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.2
    • /
    • pp.141-149
    • /
    • 2019
  • Purpose: To compare the results of two different instruments made of stainless steel and titanium alloy for correction of single thoracic adolescent idiopathic scoliosis (AIS) using pedicle screw instrumentation. Materials and Methods: A total of 141 patients with single thoracic AIS treated with pedicle screw instrumentation and selective thoracic fusion were retrospectively reviewed after a follow-up of 2 years. The patients had a main thoracic curve of 40° to 75° and were divided into two groups based on instrument materials; S group (stainless steel, n=90) and T group (titanium alloy, n=51). The diameter of the stainless steel rod used was 7.0 mm while that of the titanium alloy rod was 6.35 mm or 6.0 mm. Standing long-cassette radiographic measurements including various coronal and sagittal parameters for the preoperative, early postoperative and 2-year postoperative followup were analyzed. There were no significant differences in the preoperative curve characteristics between the two groups. Results: In the S group, the preoperative main thoracic curve of 51.3°±8.4° was improved to 19.0°±7.6° (63.1% correction) and the lumbar curve of 32.3°±8.4° spontaneously decreased to 12.7°±8.2° (62.9% correction) at 2 years postoperatively. In the T group, the preoperative main thoracic curve of 49.5°±8.4° and the lumbar curve of 30.3°±8.9° was improved to 18.8°±7.4° (62.2% correction) and 11.3°±5.4° (63.3% correction), respectively. The corrections of coronal curves were not statistically different between the two groups (p>0.05). The thoracic kyphosis was changed from 16.8°±8.5° to 24.3°±6.1° in the S group and from 19.6°±11.2° to 26.6°±8.5° in the T group. There were no significant differences in the changes of sagittal curves, coronal and sagittal balances at the 2-year follow-up and the number of fused segments and used screws between the two groups (p>0.05). Conclusion: When conducting surgery for single thoracic AIS using pedicles screw instrumentation, two different instruments made of stainless steel and titanium alloy showed similar corrections for coronal and sagittal curves.

Characteristics of Blood Mixed Cement in Percutaneous Vertebroplasty (경피적 척추 성형술에서 혈액 혼합 시멘트의 특성)

  • Seo, Jin-Hyeok;Woo, Young-Ha;Jeong, Ju-Seon;Kim, Do-Hun;Kim, Ok-Gul;Lee, Sang-Wook;Park, Chan-Ho
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.5
    • /
    • pp.435-439
    • /
    • 2019
  • Purpose: This study evaluated the efficacy of blood mixed cement for osteoporotic vertebral compression fractures in reducing the complications of percutaneous vertebroplasty using conventional cement. Materials and Methods: This study was performed retrospectively in 80 patients, from January 2016 to January 2017. Porous cement was formed by mixing 2, 4, and 6 ml of blood with 20 g of cement used previously. A tube with a diameter and length of 2.8 mm and 215 mm, respectively, was used and the polymerization temperature, setting time, and optimal passing-time were measured and compared with those using only conventional cement. Radiologically, the results were evaluated and compared. Results: The polymerization temperature was 70.3℃, 55.3℃, 52.7℃, and 45.5℃ in the conventional cement (R), 2 ml (B2), 4 ml (B4), and 6 ml (B6), respectively, and the corresponding setting time decreased from 960 seconds (R) to 558 seconds (B2), 533 seconds (B4), and 500 seconds (B6). The optimal passing-time was 45 seconds (B2), 60 seconds (B4), and 78 seconds (B6) at 73 seconds (R), respectively and as the amount of blood increased, it was similar to the cement passing-time. The radiological results showed that the height restoration rates and the vertebral subsidence rates similar among the groups. Two cases of adjacent vertebral compression fractures in the R group and one in the B2 and B4 groups were encountered, and the leakage rate of the cement was approximately two times higher than that in the conventional cement group. Conclusion: In conventional percutaneous vertebroplasty, the procedure of using autologous blood with cement decreased the polymerization temperature, reduced the setting time, and the incidence of cement leakage was low. These properties may contribute to more favorable mechanical properties that can reduce the complications compared to conventional cements alone.

Clinical Results of Footprint Restoration Anterior Cruciate Ligament Reconstruction with Remnant Preservation (잔여부 보존술식을 이용한 고유부착부 재현 전방십자인대 재건술의 임상결과)

  • Chung, Hyun-Min;Seo, Young-Jin;Song, Si Young;Cha, Myoungsoo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.6
    • /
    • pp.537-546
    • /
    • 2019
  • Purpose: Anteromedial (AM), posterolateral (PL), anterior, and posterior remnant preserving anterior cruciate ligament (ACL) reconstructions were conducted on patients with partial ACL tears based on the arthroscopic findings. The clinical results of the four groups were compared. Materials and Methods: This study included 98 patients who underwent a remnant preserving ACL reconstruction from January 2013 to June 2016 and could be followed-up for at least two years. The subjects were categorized into four groups according to the selective bundles reconstructed: group A, anteromedial selective bundle reconstruction; group B, posterolateral selective bundle reconstruction; group C, anterior bundle reconstruction; and group D, posterior bundle reconstruction. The preoperative and postoperative anterior translation from the stress X-ray, International Knee Documentation Committee Subjective Knee Form (IKDC SKF) score, Lysholm score, and hospital for special surgery (HSS) score were compared. Results: All four groups showed significant improvement in anterior translation on the stress X-ray conducted with knees at 15° flexion, IKDC SKF score, Lysholm score, and HSS score postoperatively (in all groups, p<0.001). No intergroup differences were observed in terms of the functional outcomes except that preoperative IKDC SKF score was higher in the C group than in the A group (p=0.021), and the preoperative Lysholm score was higher in the B group than in the A group (p=0.03). Conclusion: After the AM, PL, anterior, and posterior remnant preserving ACL reconstructions, all four groups showed satisfactory results in terms of the anteroposterior stability and functional knee scores with no significant intergroup differences.

Relationship between Knee Function at 1 Year Postoperation and Gap Difference (90° Flexion Gap-Extension Gap) in Total Knee Replacement (간격 차이(90° 굴곡 간격-신전 간격)와 슬관절 전 치환술 1년 후의 무릎 기능과의 관계)

  • Cho, Myung-Rae;Do, Jung-Suk;Kim, Kyung-Tae;Choi, Won-Kee
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.3
    • /
    • pp.254-260
    • /
    • 2019
  • Purpose: To evaluate the relationship between the knee function at 1 year postoperation and the gap difference (90° flexion gap-extension gap) in total knee replacement. Materials and Methods: Eighty-two consecutive osteoarthritis knees that underwent primary total knee replacement using navigation from March 2017 June 2017 were evaluated prospectively. The gap was measured using navigation after reducing the patella with towel clips. After checking the average values of the medial and lateral gaps at extension and 90° flexion knee, the gap difference (90° flexion gap-extension gap) was calculated. The knees were divided into three groups according to the gap difference (gap difference<0 mm, 0 mm≤gap difference<2 mm, 2 mm≤gap difference). The Knee Society score (KSS) and maximal knee flexion were compared at 1 year postoperation among three groups. Results: The numbers of knees according to groups were 37, 29, and 16 knees in regular order. The average of the KSS knee, KSS function, and maximal knee flexion at the 1-year follow-up were 81.21±8.31, 71.34±9.84, and 126.48°±7.28°, respectively. No statistically significant difference in KSS was observed among the 3 groups. The third group (2 mm≤gap difference) showed a larger maximal knee flexion than the other groups in the Mann-Whitney test. Conclusion: The group of total knee replacement (2 mm≤90° flexion gap-extension gap) showed larger maximal knee flexion than the other groups at the 1-year follow-up in statistics.

Development and Evaluation of Multiplex PCR for the Detection of Carbapenemase-Producing Enterobacteriaceae (카바페넴분해효소 생성 장내세균 검출을 위한 Multiplex PCR의 개발 및 평가)

  • Kim, Si Hyun;Bae, Il Kwon;Kim, Na Young;Song, Sae Am;Kim, Sunjoo;Jeong, Joseph;Shin, Jeong Hwan
    • Annals of Clinical Microbiology
    • /
    • v.22 no.1
    • /
    • pp.9-13
    • /
    • 2019
  • Background: The isolation of carbapenemase-producing Enterobacteriaceae (CPE) has become increasingly common. Continuous surveillance for these organisms is essential because their infections are closely related to outbreaks of illness and are associated with high mortality rates. The aim of this study was to develop and evaluate multiplex PCR as a means of detecting several important CPE genes simultaneously. Methods: We aimed to develop a multiplex PCR that could detect seven CPE genes simultaneously. The multiplex PCR was composed of seven primer sets for the detection of KPC, IMP, VIM, NDM-1, GES, OXA-23, and OXA-48. We designed different PCR product sizes of at least 100 bp. We evaluated the performance of this new test using 69 CPE-positive clinical isolates. Also, we confirmed the specificity to rule out false-positive reactions by using 71 carbapenem-susceptible clinical strains. Results: A total of 69 CPE clinical isolates showed positive results and were correctly identified as KPC (N=14), IMP (N=13), OXA-23 (N=12), OXA-48 (N=11), VIM (N=9), GES (N=5), and NDM (N=5) by the multiplex PCR. All 71 carbapenem-susceptible clinical isolates, including Enterococcus faecalis, Escherichia coli, Klebsiella pneumoniae, Acinetobacter baumannii, and Pseudomonas aeruginosa, showed negative results. Conclusion: This multiplex PCR can detect seven CPE genes at a time and will be useful in clinical laboratories.

Trend Analysis of Vegetation Changes of Korean Fir (Abies koreana Wilson) in Hallasan and Jirisan Using MODIS Imagery (MODIS 시계열 위성영상을 이용한 한라산과 지리산 구상나무 식생 변동 추세 분석)

  • Minki Choo;Cheolhee Yoo;Jungho Im;Dongjin Cho;Yoojin Kang;Hyunkyung Oh;Jongsung Lee
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.3
    • /
    • pp.325-338
    • /
    • 2023
  • Korean fir (Abies koreana Wilson) is one of the most important environmental indicator tree species for assessing climate change impacts on coniferous forests in the Korean Peninsula. However, due to the nature of alpine and subalpine regions, it is difficult to conduct regular field surveys of Korean fir, which is mainly distributed in regions with altitudes greater than 1,000 m. Therefore, this study analyzed the vegetation change trend of Korean fir using regularly observed remote sensing data. Specifically, normalized difference vegetation index (NDVI) from Moderate Resolution Imaging Spectroradiometer (MODIS), land surface temperature (LST), and precipitation data from Global Precipitation Measurement (GPM) Integrated Multi-satellitE Retrievalsfor GPM from September 2003 to 2020 for Hallasan and Jirisan were used to analyze vegetation changes and their association with environmental variables. We identified a decrease in NDVI in 2020 compared to 2003 for both sites. Based on the NDVI difference maps, areas for healthy vegetation and high mortality of Korean fir were selected. Long-term NDVI time-series analysis demonstrated that both Hallasan and Jirisan had a decrease in NDVI at the high mortality areas (Hallasan: -0.46, Jirisan: -0.43). Furthermore, when analyzing the long-term fluctuations of Korean fir vegetation through the Hodrick-Prescott filter-applied NDVI, LST, and precipitation, the NDVI difference between the Korean fir healthy vegetation and high mortality sitesincreased with the increasing LST and decreasing precipitation in Hallasan. Thissuggests that the increase in LST and the decrease in precipitation contribute to the decline of Korean fir in Hallasan. In contrast, Jirisan confirmed a long-term trend of declining NDVI in the areas of Korean fir mortality but did not find a significant correlation between the changes in NDVI and environmental variables (LST and precipitation). Further analyses of environmental factors, such as soil moisture, insolation, and wind that have been identified to be related to Korean fir habitats in previous studies should be conducted. This study demonstrated the feasibility of using satellite data for long-term monitoring of Korean fir ecosystems and investigating their changes in conjunction with environmental conditions. Thisstudy provided the potential forsatellite-based monitoring to improve our understanding of the ecology of Korean fir.

Distributional Characteristics of the Population and Assessment of the Conservation Status of Michelia Compressa on Korea (국내 초령목 개체군의 분포특성과 보전지위평가)

  • Jong-Gab Kim;Dae-Shin Kim;Su-Kyoung Kim;Hyun-Mi Jeong;Young-Ki Song;Sung-Won Son;Jung-Goon Koh
    • Korean Journal of Environment and Ecology
    • /
    • v.37 no.3
    • /
    • pp.182-191
    • /
    • 2023
  • This study was carried out to identify the distribution and growth characteristics and evaluate the conservation status of the Michelia compressa Maxim., a rare and endangered wild plant II, in the habitats in Korea. A total of 314 individuals were found in the natural habitats of Heuksan Island and Jeju Island and were divided into four populations. About 45.9% (144 individuals) were distributed in the range of 401m~500m above sea level. The average height of trees was 2.7(±4.8)m, the diameter at breast height was 12.6(±13.9)cm, and the number of branches was 1.0(±0.5) on average. 54.3% of the sapling individuals of M. compressa were distributed within a radius of 30 m from the mother tree, 25.8% were distributed between 31 m through 40 m, and most (90.1%) were distributed within a radius of 60 m. The fact that sapling individuals of M. compressa are not identified even around some mature individuals and appear only in extremely limited areas is estimated to be closely related to the growth conditions as well as the environment of the natural habitats. The dispersal of M. compressa is presumed to be related to the birds and natural seedlings because water puddles, a resting place for birds beyond the range of natural seedlings, characterize its habitats. The IUCN Red List evaluation criteria at the regional and national level of M. compressa corresponds to the Critically Endangered category, and the domestic population under the category of "CR B2ab(v); C2a(i); D."

Simultaneous determinations of anthracycline antibiotics by high performance liquid chromatography coupled with radial-flow electrochemical cell (고성능 액체 크로마토그래피/방사흐름 전기화학전지를 이용한 안트라사이클린계 항생제의 동시 정량)

  • Cho, Yonghee;Hahn, Younghee
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.308-314
    • /
    • 2007
  • The analytical method of HPLC with the radial-flow electrochemical cell (RFEC) has been developed to determine doxorubicin, epirubicin, nogalamycin, daunorubicin and idarubicin simultaneously by employing a reversed-phase chromatography. Anthracyclines were detected at -0.74 V vs. a Ag/AgCl (0.01 M NaCl) reference electrode, a potential of diffusion current plateau in the mobile phase. At a $V_f$ of 1.0 mL/min doxorubicin, epirubicin, daunorubicin and idarubicin appeared at a retention time ($t_r$) of 6.4 min, 7.4 min, 12.7 min and 18.4 min, respectively, while at a $V_f$ of 0.6 mL/min, doxorubicin, epirubicin, nogalamycin, daunorubicin and idarubicin appeared at a $t_r$ of 9.9 min, 11.5 min, 13.5 min, 19.6 min and 28.7 min, respectively. The linearity between each anthracycline injected ($2.40{\times}10^{-7}M{\sim}1.42{\times}10^{-5}M$) and peak area (charge) was excellent with the square of the correlation coefficient ($R^2$) higher than 0.999. The detection limits were $1.0{\times}10^{-8}M{\sim}1.5{\times}10^{-7}M$ for the five anthracyclines. Within-day precision for the five anthracyclines were in reasonable relative standard deviations less than 3 % ($1.00{\times}10^{-6}M{\sim}1.42{\times}10^{-5}M$) except the lower concentrations less than $0.7{\mu}M$. Solid phase extractions of $1.00{\times}10^{-5}M$ epirubicin, $0.48{\times}10^{-5}M$ nogalamycin and $1.52{\times}10^{-5}M$ daunorubicin from human serum with a $C_{18}$ cartridge resulted in 97 %, 100 % and 90 % of recoveries, respectively.

Study on the consumption practices and Importance-Satisfaction Analysis of meal-kit selection attributes among adults in their 20s and 30s (20-30대 성인의 밀키트 소비 실태와 밀키트 선택속성에 대한 중요도-만족도 분석)

  • Se-Eun Kim;Hyun-Joo Bae
    • Journal of Nutrition and Health
    • /
    • v.56 no.3
    • /
    • pp.315-329
    • /
    • 2023
  • Purpose: This study examined the meal-kit consumption practices of adults in their 20s and 30s and analyzed the properties that should be given priority for improvement among the selection attributes to improve the quality of meal-kits. Methods: Statistical analyses were conducted using the SPSS program (ver. 28.0) for χ2-test, t-test, one-way analysis of variance, Duncan's multiple range test, factor analysis, and Importance-Satisfaction Analysis (ISA). Results: Of the 249 subjects surveyed, 85.5% had some experience of purchasing meal-kits, with significantly more females than males (p < 0.01), significantly more married people than single people (p < 0.05), significantly more employed people than unemployed people (p < 0.05). Meal-kits were purchased most frequently for meals (60.6%), from discount stores or supermarkets (44.6%), and priced between 10,000 won and 20,000 won per person (46.9%). The overall satisfaction with meal-kits was 4.1 out of 5.0 points. The frequency of purchases was Korean soup dishes (69.5%), Korean main dishes (47.4%), and Korean street snacks (46.9%). Factor analysis of the meal-kit selection attributes revealed, 4 factors: 'quality of food,' 'packaging and diversity,' 'quality of meal-kit,' and 'convenience and price.' Compared to single-person households, multi-person households placed significantly higher importance on the 'quality of food,' 'packaging and diversity,' and 'quality of meal-kit.' The factor, 'packaging and diversity' were significantly higher in the importance evaluation scores for females (p < 0.01), married people (p < 0.05), and people in their 30s (p < 0.05) among meal-kit consumers. According to the ISA results, a critical aspect that meal-kit manufacturers or sellers should strengthen is 'price.' Conclusion: Meal-kit products will need to be developed for various purposes that offer high value for money that can satisfy the consumers' needs to improve the satisfaction of meal-kit consumers.

Effect of Freeze-Dried Korean-Style Dishes on Visceral Fats and Serum Lipid Concentrations in Rats Fed with High Fat Diet (한식첨가식(添加食)이 고지방식(高脂肪食)을 급여한 흰쥐의 내장지방과 혈청 지질농도에 미치는 영향)

  • Hong, Sang-Pil;Han, Chan-Kyu;Lee, Min-A;Yang, Ji-Na;Shin, Dong-Bum
    • Journal of the Korean Society of Food Culture
    • /
    • v.23 no.1
    • /
    • pp.90-96
    • /
    • 2008
  • This study was performed to reveal nutritional excellency of popular Korean dishes, which were intended to distribute as a take-out type food suited for Americans. Four Korean dishes were selected due to their high preference from American sensory panels: Jeyuk-bokkeum (B), Kimchi-bokkeum (C), Dubu-jorim (D) and Namul (E). Nine weeks of the experimental periods were composed of two parts. In phase 1(5 weeks of the first half), high fat diets were fed to all treatments including the control group (A). In phase 2 (4 weeks of the last half), freeze-dried four Korean dishes were fed to the treatments except for the control. There was no significant difference in the final body weights among the groups as well as daily body weight gains and FER. Organ weights of the control group tended to be smaller than those of the treatment groups. For visceral fats, perirenal fat pad (RFP) and epidydimal fat pad (EFP) of the groups C and D were decreased by 20% compared with those of the group A. Total cholesterol level of the group C (94.13 mg/dL) was significantly lower than any other groups (p<0.05), but there was no significant difference in triglyceride(TG) level. HDL-cholesterol level of group B(20.38 mg/dL) was significantly higher than that of group D (17.25 mg/dL), but no significant differences were seen in groups C and E (p<0.05). In LDL-cholesterol level, the highest level was seen in group D, the lowest level in group E (p<0.05). From the findings, Kimchi-bokkeum, Dubu-jorim and Namul were superior to those of the control and jeyukbokkeum in terms of the blood lipid profiles. It might be a good Korean style take-out items suited for the Americans’ taste along with a good nutritional quality in the near future.