• Title/Summary/Keyword: 이산화탄소 배출량 관리

Search Result 66, Processing Time 0.031 seconds

A Guideline for Construction Management Plan Based on the Characteristics of $CO_2$ Emissions: A Case Study for a High-Rise Residential Building Project ($CO_2$ 배출 특성을 고려한 건설폐기물 관리방안 수립기준: 고층 주거건물 건설 프로젝트를 대상으로 한 사례조사)

  • Kim, Jee-Hye;Shin, Dong-Woo;Cha, Hee-Sung
    • Korean Journal of Construction Engineering and Management
    • /
    • v.8 no.6
    • /
    • pp.150-158
    • /
    • 2007
  • As the amount of $CO_2$ emission in Korea is ranked 9th and the increasing rate of $CO_2$ emissions highest in the world, it is strongly necessary to devise methods to decrease the amount of $CO_2$ in each industry as the basis of establishing environmentally sustainable production system. This paper aims to identify the characteristics of $CO_2$ emissions from construction wastes throughout the simplified LCA (Life Cycle Assessment) and suggest the strategic guideline for the construction waste management plan to decrease $CO_2$. As a result of LCA on the case of a high-rise residential building project, total sum of $CO_2$ emission generated from construction wastes appeared as 6,818,123kg-$CO_2$ and $CO_2$ emission per unit floor area as 21.01kg-$CO_2/{\beta}{\ge}$. The principal waste materials generating more than 95% of $CO_2$ are materials such as reinforcing bar, temporary materials, cement, ready-mixed-concrete, concrete products, and tile, which have relatively high unit emission rate of $CO_2$ in the process of production. Besides, more than 92% of $CO_2$ was generated from the activities such as structure work, plaster work, temporary work, and tile and stone work, which are generally executed in the early phase of the whole construction period. Reflecting these results, the guideline for the construction waste management plan was recommended. If the waste management plan is established considering the guideline suggested, there would be high potential to decrease the amount of $CO_2$ generated from construction wastes.

Research on CO2 Emission Characteristics of Arterial Roads in Incheon Metropolitan City (인천광역시 간선도로의 이산화탄소 배출 특성 연구)

  • Byoung-JoYoon;Seung-Jun Lee;Hyo-Sik Hwang
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.1
    • /
    • pp.184-194
    • /
    • 2023
  • Purpose: The purpose of this study is to identify the characteristics of C02 emissions by road before establishing a policy to reduce greenhouse gas emissions. Method: As for the analysis method, the traffic volume and speed of the road were estimated using the traffic Assignment model targeting 27 arterial road axes in Incheon Metropolitan City. And, after estimating CO2 emissions by road axis by applying this, the characteristics of each group were analyzed through cluster analysis. Result: As a result of cluster analysis using total CO2 emissions, CO2 emissions by truck vehicles, and the ratio of truck vehicle emissions to total carbon dioxide emissions, four clusters were classified. When examining the characteristics of each road included in each group, it was analyzed that the characteristics of each group appeared according to the level of impact by CO2 emissions and truck vehicles. Conclusion: It is judged that it is necessary to establish a plan in consideration of CO2 emission characteristics for road CO2 management for greenhouse gas reduction.

A Methodology for CO2 Emissions Estimation with Through-Traffic (통과교통량을 고려한 이산화탄소 배출량 추정 방안 연구)

  • Kim, Tea Gyun;Hong, Ki Man;Baek, Ba Ruem;Woo, Wang Hee;Hong, Young Suk;Cho, Joong Rae
    • Journal of Korean Society of Transportation
    • /
    • v.32 no.4
    • /
    • pp.303-314
    • /
    • 2014
  • This study develops a $CO_2$ emissions estimation method, which considers different O/D travel patterns and through traffic volumes, in different regions for $CO_2$ emissions management in the field of transportation. In the research, O/D and network data provided by the Korea Transport Database (KTDB) Center are used as basic data. The results show that the total emission was similar to the Metropolitan's total emission which was estimated by KTDB (2009). With the analysis focusing on Gyeonggi-do, the results show that $CO_2$ emission from through traffic volumes was greater than $CO_2$ emissions of the Intra-Regional in southern regions; By contrast, $CO_2$ emissions of the Intra-Regional was greater than that from through traffic volumes in northern regions. Therefore, the $CO_2$ emissions management needs to be segregated into local government and nation with each travel pattern.

An analysis on CO2 emission of structural steel materials by strength using Input-Output LCA (산업연관분석법을 이용한 강도에 따른 구조용 강재의 이산화탄소 배출량 데이터 구축)

  • Hong, Tae-Hoon;Ji, Chang-Yoon;Jang, Min-Ho
    • Korean Journal of Construction Engineering and Management
    • /
    • v.13 no.4
    • /
    • pp.132-140
    • /
    • 2012
  • Along with the increasing interest in environmental problems such as global warming, the South Korean government has established policies and regulations to reduce the amount of greenhouse gases, targeting a 30% reduction of $CO_2$ compared to business-as-usual levels by 2020. Thus, there have been many studies in construction field to control and reduce the amount of $CO_2$ emitted from buildings. $CO_2$ emission from the building construction could be obtained by using the life cycle assessment(LCA) methodology. In LCA, it is essential to have life cycle inventory(LCI) data of construction materials consisting of $CO_2$ emission data that have been defined and examined in a detailed way in order to obtain more accurate and detailed $CO_2$ emission of buildings. To date, however, the LCI data have been acquired only for the representative materials. Accordingly this study aimed to propose detailed $CO_2$ emission data for steel rebar and H-beam, which are the essential structural steel materials, by strength and type. To accomplish the objective, this study used Input-Output LCA methodology which is based on the Input-Output table. It is believed that the $CO_2$ emission data of steel materials acquired from this study would allow a more accurate assessment of $CO_2$ emission for diverse structural design alternatives.

Evaluation of Life Cycle Energy Consumption and CO2 Emission of Elementary School of Buildings (초등학교 건축물의 생애주기 에너지사용량 및 이산화탄소 배출량 평가)

  • Ji, Changyoon;Hong, Taehoon;Jeong, Jaewook
    • Korean Journal of Construction Engineering and Management
    • /
    • v.17 no.3
    • /
    • pp.52-60
    • /
    • 2016
  • This study investigates and analyzes the total amount of energy consumption and $CO_2$ emission during the material manufacturing, transportation, construction, operation, and disposal phases of eight elementary school buildings in South Korea. Toward this ends, the hybrid LCA model is proposed. The life cycle energy consumption and $CO_2$ emission of eight case buildings are assessed using the hybrid LCA model with an assumption that the operation period is 40 years. As a result, the embodied(sum of the energy consumption in the material manufacturing, transportation and construction phases), operational and disposal energy were 2,279, 11,182, $228Mcal/m^2$, respectively, on average. The average embodied, operational, and disposal $CO_2$ emission were 604, 2,708, 60 kg-$CO_2/m^2$, respectively, on average. This result indicates that about 17% of life cycle energy (or $CO_2$ emission) is consumed in the material manufacturing, transportation and construction phases. Thus, it is necessary to consider the embodied energy and $CO_2$ emission to reduce the life cycle energy and $CO_2$ emission of school buildings. In addition, while the insulation standard of building have been provided based on the climate zone, energy consumption in operation phase still varied depending on the regions in this study. Thus, the insulation standard of building needs to be improved through considering the climate of regions in detail.

Comparison of the CO2 Emissions Estimations among Four Tier Methods for the Facilities from Different Industrial Sectors in Korea (국내 산업 부문에 대한 온실가스 배출량 산정 방법 결과 비교)

  • Kim, Hee Jin;Yeo, Min Ju;Kim, Yong Pyo;Jang, Geon Woo;Shin, Won Geun;Lee, Myung Hwoon;Choi, Hyung Wook
    • Journal of Climate Change Research
    • /
    • v.3 no.3
    • /
    • pp.195-209
    • /
    • 2012
  • There are four differentiated levels to quantify the amount of greenhouse gas emissions from a facility, which are Tier 1 to 4 based on the IPCC guidelines. In this study, the emission estimates from all tier levels were calculated to compare their total $CO_2$ emission results among themselves for seven facilities, including three sectors of electricity generation, municipal solid waste incineration, and cement manufacturing for three months between February and May 2011. Generally the measured $CO_2$ emissions by Tier 4 were higher than the calculated $CO_2$ emissions by Tier 3, which had been also observed for the power plants in the USA. It was found out that to obtain more reliable estimation for Tier 3, accurate analysis of the composition of the fuel used should be carried out. It was suggested that further refinement on the administrative guidelines be made to make it more robust.

The Application of CO2 and Hydrometer Sensor for Development of Real Time Measuring Method on CO2 Emission of Construction Equipment (건설장비의 CO2배출량 실시간 측정방법 개발을 위한 CO2 및 유속센서의 활용)

  • Jang, Won-Suk;Kim, Byung-Soo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.14 no.2
    • /
    • pp.78-86
    • /
    • 2013
  • The researches for reduce $CO_2$ are going along animatedly in hole industry area. In construction area, the researches to minimize $CO_2$ emission are progressing variously. The researches to minimize $CO_2$ emission based on $CO_2$ emission. The method measuring $CO_2$ emission are using $CO_2$ emission coefficient on fuel consumption, LCA and an inter-industry relation table. Especially, the methods using the carbon emission coefficient based on fuel consumption are 3 types(Tier1~Tier3) of IPCC. Present, the most using method(Tier1) is using the fuel consumption and the carbon emission coefficient. But because this method do not effect each vehicle distance and driving environment, we can't calculate right $CO_2$ emission. Especially construction project's $CO_2$ emission could be different by project's characteristic. However, we can't apply these difference with present methods. So we need methodology calculating $CO_2$ emission by applying personal project's characteristic and these methodology's most important things is directly measuring $CO_2$ emission of construction equipment which use energy. The object of this study is to develop the $CO_2$ emission calculation methodology which occur in construction process, is to suggest ways to measure in real time $CO_2$ emission from construction equipment.

Comparison of the CO2 Emissions of Buildings using Input-Output LCA Model and Hybrid LCA Model (산업연관분석법 기반 LCA 모델과 Hybrid LCA 모델의 건축물 이산화탄소 배출량 평가결과 비교)

  • Hong, Taehoon;Ji, Changyoon
    • Korean Journal of Construction Engineering and Management
    • /
    • v.15 no.4
    • /
    • pp.119-127
    • /
    • 2014
  • This study aims to determine whether or not the input output life cycle assessment (I-O LCA) model can be used to assess the carbon dioxide (CO2) emission of buildings in initial planning phase. To ensure this end, this study proposed I-O LCA model which is the simplified LCA model and Hybrid LCA model which is the detailed LCA model, and then assessed and compared the CO2 emission of six case projects (three apartment complexes and three educational facilities) using the two LCA model. The results of the case study showed that the CO2 emissions assessed by the I-O LCA is significantly similar to the CO2 emission assessed by the Hybrid LCA model. The similarity of results from both LCA models was 78.2-86.3% in apartment complexes and 59.9-84.8% in educational facilities. However, the CO2 emissions from I-O LCA model were smaller than the CO2 emissions from Hybrid LCA model in case study. Nevertheless, the case study showed that the I-O LCA model was capable of assessing the CO2 emission of buildings quite appropriately although the I-O LCA model is the simplified LCA model which considers only the construction cost. The I-O LCA model is expected to be a useful tool for assessing the CO2 emission of buildings in initial planning phase.

Evaluating Carbon Dioxide Emission from Cadastral Category based on Tier 3 Approach (Tier 3 방식에 의거한 지목별 온실가스 배출 실태평가)

  • Kim, Dae-Ho;Um, Jung-Sup
    • Spatial Information Research
    • /
    • v.19 no.3
    • /
    • pp.11-22
    • /
    • 2011
  • It is usual for the carbon dioxide emission to be calculated by official energy consumption statistics produced from a number of specialized industrial process such as refinery, power plant etc. The aim of this research was to evaluate potential of cadastral system in monitoring carbon dioxide emitted from land use. An empirical study for a cadastral category was conducted to demonstrate how a on-site measurement can be used to assist in estimating the carbon dioxide emission in terms of land use specific settings. The cadastral category based analysis made it possible to identify area-wide patterns of carbon dioxide emission, which cannot be acquired by traditional Government statistics. It was possible to identify successively increasing trends in the human-related parcels such as housing land while decreasing trends of carbon dioxide in sink parcels(eg. forest). The results indicate that the cadastral parcel could be used not only as a tool to monitor carbon dioxide emission, but also as an evidence to restrict initiation of development activities causing negative influence to carbon dioxide emission such as road construction. As a result, the research findings have established the new concept of "carbon dioxide emission monitoring based on cadastral category", proposed as an initial aim of this paper.

Evaluation of Life Cycle Carbon Dioxide Emission of Rain-water Collecting System for Low Impact Development (저영향개발을 위한 빗물 집수시스템의 전과정 이산화탄소 배출량의 평가)

  • Kim, Young Woon;Kim, Yong In;Kim, Chang Hyun;Gong, Yun Jung;Yang, Jeong-Seok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.516-516
    • /
    • 2017
  • 기후변화로 인하여, 홍수, 사막화, 엘니뇨 등의 자연재해가 이전보다 더 발생하고 있다. 기후변화 적응은 전 세계적으로 기후변화 대응보다 중요해지고 있다. 기후변화 적응을 위한 이슈 중 하나가 물 순환이다. 각 국가에서는 물 순환을 활성화하기 위한 기술을 개발하고 있다. 특히, 저영향개발(LID, Low Impact Development)이라는 물을 확보하기 위한 정책이 각 국가별로 추진되고 있으며, 이에 따른 기술이 개발되고 있다. 국내에서도 2001년에 국토해양부는 수자원장기종합계획을 발표하고, 환경부에서는 2013년에 LID기술요소 가이드라인과 환경영향평가 시 적용 가능한 저영향개발 매뉴얼을 개발하는 등 LID기술을 개발하고 적용하기 위한 정책을 펼치고 있다. 이러한 LID기술 중 하나가 빗물 집수시스템이며, 이 빗물집수시스템은 주거지역에서 빗물을 배수하고, 집수하여 빗물을 이용하기 위해 적용되고 있다. 현재 적용되고 있는 빗물 집수시스템은 측구 집수시스템과 원형 집수시스템이 있으며, 최근에는 수로형 집수시스템이 적용되는 지역도 있다. 본 연구에서는 전과정 평가(LCA, Life Cycle Assessment)를 이용하여 빗물 집수시스템의 환경성을 평가하고자 한다. 현재, 국내에서는 녹색건축물인증, 탄소성적 표지인증, 환경성적 표지인증 등 LCA를 이용하여 환경성을 평가하고 있다. 특히, 본 연구에서는 기후변화 측면에서 LCA를 적용하여 이산화탄소배출량을 평가하고자 하였다. 본 연구의 범위는 빗물집수시스템 30m로 가정하였으며, 측구 집수시스템, 원형 집수시스템 및 수로형 집수시스템의 건설, 운영 및 유지관리, 해체 및 폐기단계의 전 과정이다. 각 빗물 집수시스템에 대해 각 단계별로 이산화탄소 배출량을 산정한 결과, 수로형 집수시스템은 $2.82\;ton\;CO_2\;eq./set$이며, 원형 집수시스템은 $27.65\;ton\;CO_2\;eq./set$, 측구 집수시스템은 $21.54\;ton\;CO_2\;eq./set$이 배출되었다. 이산화탄소배출량 측면에서는 수로형 집수시스템이 나머지 두집수시스템보다 87~90%가 저감되는 것으로 나타났다. 본 연구는 저영향개발에 대응하는 동시에 기후변화를 대응한다는 측면에서 빗물 집수시스템 정책에 활용되고, 설계시에도 반영될 수 있을 것으로 사료된다. 추가적으로 이산화탄소뿐 만 아니라, 다른 환경성을 평가하는 연구가 진행될 필요가 있다.

  • PDF