• Title/Summary/Keyword: 이동성 분석

Search Result 6,699, Processing Time 0.036 seconds

Difference of Somatic Symptoms between Anxiety Disorder and Major Depressive Disorder and Their Domainal Association with Suicidal Idealization, Plan and Attempts (불안 장애와 주요우울장애에서 나타나는 신체 증상과 증상군에 따른 자살 사고, 계획, 행동과의 관계 고찰)

  • Ahn, Jun Seok;Kim, Eun young;Cho, Maeng Je;Hong, Jin Pyo;Hahm, Bong-Jin;Chung, In-Won;Ahn, Joon-Ho;Jeon, Hong Jin;Seong, Su Jeong;Lee, Dong-Woo
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.24 no.2
    • /
    • pp.174-183
    • /
    • 2016
  • Objectives : The aim of this study is to evaluate difference of somatic symptoms of anxiety disorder and major depressive disorder and domainal association with suicidal idealization, plan, and attempts. Methods : A total of 359 adults diagnosed with major depressive disorder and anxiety disorder of last one year participated. Participants interviewed with certain sections of Korean version of Composite International Diagnostic interview of CIDI. Sections of interests includes questionnaires regarding somatic symptoms and suicidal idea, plan and attempts of last one year. Results : Chest pain shows more prevalence in major depressive disorder. Symptoms of Headache and loose stool are more prevalent in anxiety disorder. Difficulty in equilibrium and fainting spells are more common somatic complaints of co-diagnosis states of anxiety disorder and major depressive disorder. Comparing 3 domains of pain symptoms, gastrointestinal symptoms and pseudo-neurological symptoms, pain symptom domains, gastrointestinal symptoms domain shows significant statistic difference between diagnosis. Average somatic symptom numbers of each symptom domains increase through suicidal idealization, plan and attempt, accordingly. Conclusions : Our finding shows some of somatic symptoms are more prevalent at certain diagnosis. Since increasing numbers of somatic complaints of each symptom domains goes with the suicidal idealization to suicidal attempts, proper psychiatric evaluation and consultations are crucial for patients with numerous somatic complaints in non-psychiatric clinical settings.

The Relationship between Cultural Self-construal of Korean and Alexithymia: A Serial Mediation Process Model of Ambivalence over Emotion Expression and Emotion Suppression Moderated by Generation (한국인의 문화적 자기관과 감정표현불능증의 관계: 세대에 의해 조절된 정서표현양가성 및 정서억제 연속매개과정 모형)

  • Haejin Kim;Soyoung Kwon;Sunho Jung;Donghoon Lee
    • Korean Journal of Culture and Social Issue
    • /
    • v.29 no.2
    • /
    • pp.171-197
    • /
    • 2023
  • The traditional Korean society has been classified as an Eastern collectivist culture, but in the flow of globalization and digitalization along with the post-Cold War era of the 1970s, Western individualistic culture and values quickly permeated the Korean younger generation. Since rapid changes occurred within a short period of time, there may be differences in cultural self-construal between generations living in the same era. Due to this, psychological problems related to emotional expression and suppression may appear differently depending on generations. Therefore, in the current study, 1,000 Korean adult men and women from their 20s to 60s were investigated for their level of independent and interdependent self-construal, alexithymia, ambivalence over emotional expression(AEE) and emotional suppression(ES). Then the relationship between the variables(self-construal and alexithymia,) and the mediating process of AEE and ES were examined. The generation of participants were divided into the industrialization cohort (birth year < 1970) and the digitalization cohort (birth year starting from 1970). Using the PROCESS macro(Hayes, 2022), we tested a serial mediation model of AEE and ES between the relative independent self-construal(RIS) and alexithymia. The results indicate that the level of alexithymia increases by the serial increase of AEE and ES when RIS decreases. Next, we examined a moderation effect of generatione on the mediation process of AEE and ES, and found that generation moderates the relationship between ES and alexithymia. That is, the effect of ES on alexithymia is significant for the digitalization cohort, while it is not significant for the industrialization cohort. The current results imply that emotion regulation strategies of Koreans have been differently developed according to prevailing cultural values in each generation, and that the negative influence of emotion suppression could be different according to the cultural background of each generation.

Association Between Chronotype, Sleep Quality and Resilience as Well as Anxiety Among Medical Students (의과대학 학생들의 일주기 유형과 수면의 질 및 회복탄력성과 불안 증상의 관련성)

  • Jeein Kim;Bong-Jo Kim;Chul-Soon Lee;Boseok Cha;So-Jin Lee;Dongyun Lee;Jiyeong Seo;Jae-Won Choi;Young-Ji Lee;Eunji Lim
    • Sleep Medicine and Psychophysiology
    • /
    • v.29 no.1
    • /
    • pp.21-28
    • /
    • 2022
  • Objectives: Our study aimed to investigate the relationship between the anxiety at first year and chronotype and sleep quality at third year in medical students. We also investigated the association between sleep quality, chronotype, depression and resilience at third year. Methods: Fifty two medical students (36 males, 69%, aged 21 ± 0.93) in first year, and forty four medical students (31 males, 70.5%, aged 23.05 ± 0.99) at third year answered Beck Depression Inventory 2, Beck anxiety inventory, Insomnia severity index-K, Composite scale of morningness and Conner-Davidson Resilience scale-10. Multiple linear regression analysises were performed to identify predictors of chronotype, sleep quality and resilience. Results: Higher anxiety (β = -0.434, p = 0.006) at first year was significant predictor of eveningness at third year, while lower anxiety score (β = 0.606, p < 0.001) at first year was significant predictor of sleep quality at third year. Lower sleep quality (β = -0.314, p = 0.042) and eveningness (β = 0.315, p = 0.041) were associated with low resilience at third year. Also, Lesser depression (β = -0.717, p < 0.001) was associated with higher resilience at third year. Conclusion: Our study showed that higher anxiety in first year had significantly related with eveningness and poor sleep quality at third year. In addition, higher sleep quality, morningness and less depression had significantly associated with better resilience at third year.

Fish Community Characteristics and the Effects of Water Quality on River Health in the Anyang Stream, Korea (안양천의 어류군집 특성 및 수질이 하천건강성에 미치는 영향)

  • Jae-Woo Joo;Myeong-Hun Ko
    • Korean Journal of Environment and Ecology
    • /
    • v.38 no.2
    • /
    • pp.189-203
    • /
    • 2024
  • This study conducted a survey two times at 20 points from April to June and from August to October 2022 to characterize the fish community and reveal the health of the Anyang stream. The survey collected 3,186 individuals belonging to 5 orders, 10 families and 34 species. The dominant species was Zacco platypus (43.4%), followed by Carassius auratus (10.1%), Cyprinus carpio (7.6%), Zacco koreanus (6.2%), Pungtungia herzi (5.2%), Oryzias sinensis (5.1%), Pseudorasbora parva (4.7%), Squalidus gracilis majimae (4.4%), Rhynchocypris oxycephalus (3.5%), Hemiculter eigenmanni (3.3%), Rhodeus ocellatus (1.4%), and Chelon haematocheilus (1.0%). Among the emerged species, 5 species (14.7%), including Rhodeus uyekii, Squalidus japonicus coreanus, and Odontobutis interrupta, were endemic to Korea, and 4 species (11.8%), including Cyprinus carpio (Israeli type), Lepomis macrochirus, Micropterus salmoides, and Poecilia reticulata, were exotic. The fish community analysis showed that the dominance was higher at the upper reaches of the Anyang stream and decreased downstream, and diversity, richness, and evenness were higher in tributary than mainstream. Stream health (fish assessment index, FAI) was generally poor, as it was rated as moderate (C) at seven sites, poor (D) at eight sites, and very poor (E) at five sites. Water quality was evaluated at eight sites, and it was rated as poor (V) at two sites, slightly poor (IV) at one site, moderate (III) at four sites, and slightly good (II) at one site, indicating that the overall water quality was poor and that the water quality had a significant impact on river health and fish habitat. Moreover, it was found that many weirs without fishways were constructed in the Anyang stream and became an obstacle to fish migration. Therefore, a systematic management plan to improve water quality and add fishways is necessary to improve the stream's health and conserve stable fish habitat.

Evaluating efficiency of application the skin flash for left breast IMRT. (왼쪽 유방암 세기변조방사선 치료시 Skin Flash 적용에 대한 유용성 평가)

  • Lim, Kyoung Dal;Seo, Seok Jin;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.49-63
    • /
    • 2018
  • Purpose : The purpose of this study is investigating the changes of treatment plan and comparing skin dose with or without the skin flash. To investigate optimal applications of the skin flash, the changes of skin dose of each plans by various thicknesses of skin flash were measured and analyzed also. Methods and Material : Anthropomorphic phantom was scanned by CT for this study. The 2 fields hybrid IMRT and the 6 fields static IMRT were generated from the Eclipse (ver. 13.7.16, Varian, USA) RTP system. Additional plans were generated from each IMRT plans by changing skin flash thickness to 0.5 cm, 1.0 cm, 1.5 cm, 2.0 cm and 2.5 cm. MU and maximum doses were measured also. The treatment equipment was 6MV of VitalBeam (Varian Medical System, USA). Measuring device was a metal oxide semiconductor field-effect transistor(MOSFET). Measuring points of skin doses are upper (1), middle (2) and lower (3) positions from center of the left breast of the phantom. Other points of skin doses, artificially moved to medial and lateral sides by 0.5 cm, were also measured. Results : The reference value of 2F-hIMRT was 206.7 cGy at 1, 186.7 cGy at 2, and 222 cGy at 3, and reference values of 6F-sIMRT were measured at 192 cGy at 1, 213 cGy at 2, and 215 cGy at 3. In comparison with these reference values, the first measurement point in 2F-hIMRT was 261.3 cGy with a skin flash 2.0 cm and 2.5 cm, and the highest dose difference was 26.1 %diff. and 5.6 %diff, respectively. The third measurement point was 245.3 cGy and 10.5 %diff at the skin flash 2.5 cm. In the 6F-sIMRT, the highest dose difference was observed at 216.3 cGy and 12.7 %diff. when applying the skin flash 2.0 cm for the first measurement point and the dose difference was the largest at the application point of 2.0 cm, not the skin flash 2.5 cm for each measurement point. In cases of medial 0.5 cm shift points of 2F-hIMRT and 6F-sIMRT without skin flash, the measured value was -75.2 %diff. and -70.1 %diff. at 2F, At -14.8, -12.5, and -21.0 %diff. at the 1st, 2nd and 3rd measurement points, respectively. Generally, both treatment plans showed an increase in total MU, maximum dose and %diff as skin flash thickness increased, except for some results. The difference of skin dose using 0.5 cm thickness of skin flash was lowest lesser than 20 % in every conditions. Conclusion : Minimizing the thickness of skin flash by 0.5 cm is considered most ideal because it makes it possible to keep down MUs and lowering maximum doses. In addition, It was found that MUs, maximum doses and differences of skin doses did not increase infinitely as skin flash thickness increase by. If the error margin caused by PTV or other factors is lesser than 1.0 cm, It is considered that there will be many advantages in with the skin flash technique comparing without it.

  • PDF

USABILITY EVALUATION OF PLANNING MRI ACQUISITION WHEN CT/MRI FUSION OF COMPUTERIZED TREATMENT PLAN (전산화 치료계획의 CT/MRI 영상 융합 시 PLANNING MRI영상 획득의 유용성 평가)

  • Park, Do-Geun;Choe, Byeong-Gi;Kim, Jin-Man;Lee, Dong-Hun;Song, Gi-Won;Park, Yeong-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.127-135
    • /
    • 2014
  • Purpose : By taking advantage of each imaging modality, the use of fused CT/MRI image has increased in prostate cancer radiation therapy. However, fusion uncertainty may cause partial target miss or normal organ overdose. In order to complement such limitation, our hospital acquired MRI image (Planning MRI) by setting up patients with the same fixing tool and posture as CT simulation. This study aims to evaluate the usefulness of the Planning MRI through comparing and analyzing the diagnostic MRI image and Planning MRI image. Materials and Methods : This study targeted 10 patients who had been diagnosed with prostate cancer and prescribed nonhormone and definitive RT 70 Gy/28 fx from August 2011 to July 2013. Each patient had both CT and MRI simulations. The MRI images were acquired within one half hour after the CT simulation. The acquired CT/MRI images were fused primarily based on bony structure matching. This study measured the volume of prostate in the images of Planning MRI and diagnostic MRI. The diameters at the craniocaudal, anteroposterior and left-to-right directions from the center of prostate were measured in order to compare changes in the shape of prostate. Results : As a result of comparing the volume of prostate in the images of Planning MRI and diagnostic MRI, they were found to be $25.01cm^3$(range $15.84-34.75cm^3$) and $25.05cm^3$(range $15.28-35.88cm^3$) on average respectively. The diagnostic MRI had an increase of 0.12 % as compared with the Planning MRI. On the planning MRI, there was an increase in the volume by $7.46cm^3$(29 %) at the transition zone directions, and there was a decrease in the volume by $8.52cm^3$(34 %) in the peripheral zone direction. As a result of measuring the diameters at the craniocaudal, anteroposterior and left-to-right directions in the prostate, the Planning MRI was found to have on average 3.82cm, 2.38cm and 4.59cm respectively and the diagnostic MRI was found to have on average 3.37cm, 2.76cm and 4.51cm respectively. All three prostate diameters changed and the change was significant in the Planning MRI. On average, the anteroposterior prostate diameter decrease by 0.38cm(13 %). The mean right-to-left and craniocaudal diameter increased by 0.08cm(1.6 %) and 0.45cm(13 %), respectively. Conclusion : Based on the results of this study, it was found that the total volumes of prostate in the Planning MRI and the diagnostic MRI were not significantly different. However, there was a change in the shape and partial volume of prostate due to the insertion of prostate balloon tube to the rectum. Thus, if the Planning MRI images were used when conducting the fusion of CT/MRI images, it would be possible to include the target in the CTV without a loss as much as the increased volume in the transition zone. Also, it would be possible to reduce the radiation dose delivered to the rectum through separating more clearly the reduction of peripheral zone volume. Therefore, the author of this study believes that acquisition of Planning MRI image should be made to ensure target delineation and localization accuracy.

Evaluation of Combine IGRT using ExacTrac and CBCT In SBRT (정위적체부방사선치료시 ExacTrac과 CBCT를 이용한 Combine IGRT의 유용성 평가)

  • Ahn, Min Woo;Kang, Hyo Seok;Choi, Byoung Joon;Park, Sang Jun;Jung, Da Ee;Lee, Geon Ho;Lee, Doo Sang;Jeon, Myeong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.201-208
    • /
    • 2018
  • Purpose : The purpose of this study is to compare and analyze the set-up errors using the Combine IGRT with ExacTrac and CBCT phased in the treatment of Stereotatic Body Radiotherapy. Methods and materials : Patient who were treated Stereotatic Body Radiotherapy in the ulsan university hospital from May 2014 to november 2017 were classified as treatment area three brain, nine spine, three pelvis. First using ExacTrac Set-up error calibrated direction of Lateral(Lat), Longitudinal(Lng), Vertical(Vrt), Roll, Pitch, Yaw, after applied ExacTrac moving data in addition to use CBCT and set-up error calibrated direction of Lat, Lng, Vrt, Rotation(Rtn). Results : When using ExacTrac, the error in the brain region is Lat $0.18{\pm}0.25cm$, Lng $0.23{\pm}0.04cm$, Vrt $0.30{\pm}0.36cm$, Roll $0.36{\pm}0.21^{\circ}$, Pitch $1.72{\pm}0.62^{\circ}$, Yaw $1.80{\pm}1.21^{\circ}$, spine Lat $0.21{\pm}0.24cm$, Lng $0.27{\pm}0.36cm$, Vrt $0.26{\pm}0.42cm$, Roll $1.01{\pm}1.17^{\circ}$, Pitch $0.66{\pm}0.45^{\circ}$, Yaw $0.71{\pm}0.58^{\circ}$, pelvis Lat $0.20{\pm}0.16cm$, Lng $0.24{\pm}0.29cm$, Vrt $0.28{\pm}0.29cm$, Roll $0.83{\pm}0.21^{\circ}$, Pitch $0.57{\pm}0.45^{\circ}$, Yaw $0.52{\pm}0.27^{\circ}$ When CBCT is performed after the couch movement, the error in brain region is Lat $0.06{\pm}0.05cm$, Lng $0.07{\pm}0.06cm$, Vrt $0.00{\pm}0.00cm$, Rtn $0.0{\pm}0.0^{\circ}$, spine Lat $0.06{\pm}0.04cm$, Lng $0.16{\pm}0.30cm$, Vrt $0.08{\pm}0.08cm$, Rtn $0.00{\pm}0.00^{\circ}$, pelvis Lat $0.06{\pm}0.07cm$, Lng $0.04{\pm}0.05cm$, Vrt $0.06{\pm}0.04cm$, Rtn $0.0{\pm}0.0^{\circ}$. Conclusion : Combine IGRT with ExacTrac in addition to CBCT during Stereotatic Body Radiotherapy showed that it was possible to reduce the set-up error of patients compared to single ExacTrac. However, the application of Combine IGRT increases patient set-up verification time and absorption dose in the body for image acquisition. Therefore, depending on the patient's situation that using Combine IGRT to reduce the patient's set-up error can increase the radiation treatment effectiveness.

  • PDF

Edge to Edge Model and Delay Performance Evaluation for Autonomous Driving (자율 주행을 위한 Edge to Edge 모델 및 지연 성능 평가)

  • Cho, Moon Ki;Bae, Kyoung Yul
    • Journal of Intelligence and Information Systems
    • /
    • v.27 no.1
    • /
    • pp.191-207
    • /
    • 2021
  • Up to this day, mobile communications have evolved rapidly over the decades, mainly focusing on speed-up to meet the growing data demands of 2G to 5G. And with the start of the 5G era, efforts are being made to provide such various services to customers, as IoT, V2X, robots, artificial intelligence, augmented virtual reality, and smart cities, which are expected to change the environment of our lives and industries as a whole. In a bid to provide those services, on top of high speed data, reduced latency and reliability are critical for real-time services. Thus, 5G has paved the way for service delivery through maximum speed of 20Gbps, a delay of 1ms, and a connecting device of 106/㎢ In particular, in intelligent traffic control systems and services using various vehicle-based Vehicle to X (V2X), such as traffic control, in addition to high-speed data speed, reduction of delay and reliability for real-time services are very important. 5G communication uses high frequencies of 3.5Ghz and 28Ghz. These high-frequency waves can go with high-speed thanks to their straightness while their short wavelength and small diffraction angle limit their reach to distance and prevent them from penetrating walls, causing restrictions on their use indoors. Therefore, under existing networks it's difficult to overcome these constraints. The underlying centralized SDN also has a limited capability in offering delay-sensitive services because communication with many nodes creates overload in its processing. Basically, SDN, which means a structure that separates signals from the control plane from packets in the data plane, requires control of the delay-related tree structure available in the event of an emergency during autonomous driving. In these scenarios, the network architecture that handles in-vehicle information is a major variable of delay. Since SDNs in general centralized structures are difficult to meet the desired delay level, studies on the optimal size of SDNs for information processing should be conducted. Thus, SDNs need to be separated on a certain scale and construct a new type of network, which can efficiently respond to dynamically changing traffic and provide high-quality, flexible services. Moreover, the structure of these networks is closely related to ultra-low latency, high confidence, and hyper-connectivity and should be based on a new form of split SDN rather than an existing centralized SDN structure, even in the case of the worst condition. And in these SDN structural networks, where automobiles pass through small 5G cells very quickly, the information change cycle, round trip delay (RTD), and the data processing time of SDN are highly correlated with the delay. Of these, RDT is not a significant factor because it has sufficient speed and less than 1 ms of delay, but the information change cycle and data processing time of SDN are factors that greatly affect the delay. Especially, in an emergency of self-driving environment linked to an ITS(Intelligent Traffic System) that requires low latency and high reliability, information should be transmitted and processed very quickly. That is a case in point where delay plays a very sensitive role. In this paper, we study the SDN architecture in emergencies during autonomous driving and conduct analysis through simulation of the correlation with the cell layer in which the vehicle should request relevant information according to the information flow. For simulation: As the Data Rate of 5G is high enough, we can assume the information for neighbor vehicle support to the car without errors. Furthermore, we assumed 5G small cells within 50 ~ 250 m in cell radius, and the maximum speed of the vehicle was considered as a 30km ~ 200 km/hour in order to examine the network architecture to minimize the delay.

6·25 Special Play Study (6·25 특집극 <최후의 증인> 연구)

  • Song, Chihyuk
    • (The) Research of the performance art and culture
    • /
    • no.42
    • /
    • pp.47-75
    • /
    • 2021
  • This thesis looks into the interpretation of the Korean War and mystery genre in Korea in the 1970s by analyzing the special drama , in which the theme was directly related to the Korean War, airing through MBC in 1979. It begins by finding the change in direction in the 1970s when the world of TV was dictated through the heavy censorship and the memory of the war by the government. It also looks at the intentions of the producer who was taking in the new way and the viewers who also accepted this drama and its reflections. In order to gain some insights into these issues, it compares between the drama "The Last Witness" and the original novel by Seong-jong Kim who holds the same time to see the way in which this is dramatized. The drama, "The Last Witness", was produced with a plan to generate a high-quality special drama which combined both artistry and sense of purpose. Nevertheless, as watching TV became a leisurely past-time during this period, TV dramas become more aggressive and suggestive in order to attract viewers. This ultimately was encored with obstacles due to the regime and the heavy censorship at the time. The genre of special drama that is well known in South Korea, is designed as an art form to satisfy both their unique artistry and its purpose. The conflict is seen between the key elements of the artistic drama crated by the producers and the 'encouraged' elements that often are needed to engage the viewers. Thus, more often than not, special dramas defeat the original intention of national harmony, encouraged by the regime. This is due to the 'novelty' aspect which grows from the effort of bringing enjoyment to viewers whilst also trying to achieve the artistic drama to life. Alongside this, crime element in this drama is designed in a way that visually embodies the process of deduction, becoming a new possibility to secure the reality of the times. However, it was also a paradoxical existence since it was indicated as an example of unrefined culture that lost its original intention. In that way, it is worth to think that detective suspense stories, which were not popular in Korea, influenced viewers as a tv drama series in the 1970s through the various elements that compose the genre. They went through a process of transplantation and acceptance whilst also attempting to satisfy the viewers and their encouraged elements to engage them. As is well known, crime drama in Korea has its own style by mixing anticommunism and detective reasoning. This combination is found in the way in which the genre naturally forms through the elements selected and excluded in the dramatization of "The Last Witness". The point is that the special drama "The Last Witness" can be seen as an intermediate form that shows the tendency of transformation from the detective reasoning form alongside the crime aspects as TV dramas began to include anticommunism messaging and investigation in the 1970s. In conclusion, when the detective reasoning is used as an element in a TV drama, it shows the trust of the public system and it constantly seeks the possibility of circumventing the political interpretation. The memories of the war is seen as a tool that neutralizes the dismal imaginations inscribed on the dark side of society and the system. As a result, "The Last Witness", broadcasted at the end of the Yushin regime in Korea, is a strange result which combines the logic of a special drama and the encouraged characteristics of television dramas. The viewers' desire which is the discussion about the hidden traces from the texts needs to be restored again.

Evaluation of HalcyonTM Fast kV CBCT effectiveness in radiation therapy in cervical cancer patients of childbearing age who performed ovarian transposition (난소전위술을 시행한 가임기 여성의 자궁경부암 방사선치료 시 난소선량 감소를 위한 HalcyonTM Fast kV CBCT의 유용성 평가 : Phantom study)

  • Lee Sung Jae;Shin Chung Hun;Choi So Young;Lee Dong Hyeong;Yoo Soon Mi;Song Heung Gwon;Yoon In Ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.73-82
    • /
    • 2022
  • Purpose: The purpose of this study is to evaluate the effectiveness of reducing the absorbed dose to the ovaries and the quality of the CBCT image when using the HalcyonTM Fast kV CBCT of cervical cancer patients of child-bearing age who performed ovarian transposition Materials and Methods : Contouring of the cervix and ovaries required for measurement was performed on the computed tomography images of the human phantom (Alderson Rando Phantom, USA), and three Optically Stimulated Luminescence Dosimeter(OSLD) were attached to the selected organ cross-section, respectively. In order to measure the absorbed dose to the cervix and ovaries in the TruebeamTM pelvis mode (Hereinafter referred to as TP), The HalcyonTM Pelvis mode (Hereinafter referred to as HP) and The HalcyonTM Pelvis Fast mode (Hereinafter referred to as HPF), An image was taken with a scan range of 17.5 cm and also taken an image that reduced the Scan range to 12.5cm. A total of 10 cumulative doses were summed, It was replaced with a value of 23 Fx, the number of cervical cancer treatments, and compared In additon, uniformity, low contrast visibility, spatial resolution, and geometric distortion were compared and analyzed using Catphan 504 phantom to compare CBCT image quality between equipment. Each factor was repeatedly measured three times, and the average value was obtained by analysing with the Doselab (Mobius Medical Systems, LP. Versions: 6.8) program. Results: As a result of measuring absorbed dose by CBCT with OSLD, TP and HP did not obtain significant results under the same conditions. The mode showing the greatest reduction value was HPF versus TP. In HPF, the absorbed dose was reduced by 39.8% in the cervix and 19.8% in the ovary compared to the TP in the scan range of 17.5 cm. the scan range was reduced to 12.5 cm, absorbed dose was reduced by 34.2% in the cervix and 50.5% in the ovary. In addition, result of evaluating the quality of the image used in the above experiment, it complied with the equipment manufacturer's standards with Geometric Distortion within 1mm (SBRT standard), Uniformity HU, LCV within 2.0%, Spatial Resolution more than 3 lp/mm. Conclusion: According to the results of this experiment, HalcyonTM can select more various conditions than TruebeamTM in treatment of fertility woman who have undergone ovarian Transposition , because it is important to reduce the radiation dose by CBCT during radiation therapy. So finally we recommend HalcyonTM Fast kV CBCT which maintains image quality even at low mAs. However, it is consider that the additional exposure to low doses can be reduced by controlling the imaging range for patients who have undergone ovarian transposition in other treatment machines.