• Title/Summary/Keyword: 의학적 평가

Search Result 1,979, Processing Time 0.033 seconds

Osteoporotic Vertebral Fractures: SPECT Findings (골다공증에 동반된 척추골절의 골 SPECT 소견)

  • Baik, Jun-Hyun;Park, Young-Ha;Ihn, Yon-Kwon;Kim, Sung-Hoon;Chung, Yong-An;Yoo, Ie-Ryung;Kim, Jee-Yeung;Jung, Hyun-Seok;Sohn, Hyung-Seon;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.6
    • /
    • pp.522-527
    • /
    • 2004
  • Purpose: The purpose of this study was to evaluate the usefulness of single photon emission computed tomography (SPECT) of bone using Tc-99m MDP in the diagnosis of osteoporotic vertebral fractures. Materials and Methods: Thirty two patients with osteoporotic vertebral fracture were included in this study (mean age: $67{\pm}8$, male: 5, female: 27). Seventy nine vertebral fractures were detected (38 thoracic/thoracolumbar lesions and 41 lumbar lesions), which were classified by type of deformity (wedge, biconcave or compression). The patterns and locations of increased uptakes were examined and analyzed. Results: Forty seven wedge fractures, 20 biconcave fractures and 12 compression fractures were found. Diffuse and asymmetric uptakes were common in fractured bodies. More than one uptake were examined in 69 posterior elements of fractured vertebrae (87.3%) including 40 of 47 wedge fractures (85.1%), 17 of 20 biconcave fractures (85.0%) and 12 of 12 compression fractures (100%). Wedge fractures were predominant fracture in thoracic/thoracolumbar spine whereas incidence of biconcave or compression type war similar to that of wedge fracture in lumbar spine (p=0.04). Spinous process uptake was more frequently seen in lumbar lesions than thoracic/thoracolumbar lesions (p=0.009). Facet joint uptake in biconcave fracture was more common in lumbar spine (92.3%) than thoracic/thoracolumbar spine (57.1%). Spinous process uptake in biconcave fracture was also more frequently detected in lumbar spine (p=0.043). Conclusion: Bone SPECT was useful in the evaluation of osteoporotic vertebral fracture, especially posterior elements of vertebrae.

Complications of PCL Reconstruction using Tibial Inlay Technique (경골 Inlay 방법을 이용한 후방 십자 인대 재건술의 합병증)

  • Kim Myung-Ho;Park Hee-Gon;Yoo Moon-Jib;Byun Woo-Sup;Shim Shang-Ho
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.3 no.2
    • /
    • pp.128-133
    • /
    • 2004
  • Purpose: This study was planned to evaluate complications? of posterior cruciate ligament (PCL) reconstruction with tibial inlay technique using autogenous bone-patellar tendon-bone graft. Materials and Methods: From September 1994 to January 2004, we analyzed surgical complications in fifty-seven patients with fifty-eight cases who underwent PCL reconstruction. Fifty of them were male and seven female. The mean age of the patients was 35(15$\~$73). Twenty eight cases of injury were isolated PCL, while thirty cases had associated injury of knee. The causes of injury were thirty-nine cases of traffic accident, seven sport injuries, seven fall down injuries, and five of others. The follow-up study was done at 4 weeks, 3 months,6 months and 1 year after surgery. KT-2000 arthrometer and posterior stress X-ray were used to examine the stability of the knee joint and the Lysholm Knee Score and a variety of clinical complications were evaluated. Results: Although the mean score of the preoperative Lysholm Knee Score was 43.2, the postoperative score was increased to 87.9. The preoperative mean value of knee stability using KT-2000 arthrometer was 8.75 mm(6.2$\~$14.3 mm) but the postoperative mean was 3.41 mm(2.1$\~$10.6 mm). The intraoperative complications were: one case of popliteal artery injury with compartment syndrome, one case of patellar fracture, two cases of 20$^{\circ}$ flexion loss, and two cases of anterior cortical penetration of the screw through proximal tibia during screw fixation. The postoperative complications were: eleven cases of knee instability, one case of patellar fracture, five cases of extension loss, thirteen cases of flexion loss, twenty-one cases of around knee pain and eight cases of kneeling pain. Conclusion: After PCL reconstruction with tibial inlay technique using autogenous bone-patella tendon-bone graft, complications were observed in this study. Careful attention during and after the operation, as well as rehabilitation must be required.

  • PDF

Performance Characteristics of MicroPET R4 Scanner for Small Animal Imaging (소동물 영상을 위한 MicroPET R4스캐너의 특성평가)

  • Lee, Byeong-Il;Lee, Jae-Sung;Kim, Jin-Su;Lee, Dong-Soo;Choi, Chang-Un;Lim, Sang-Moo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.49-56
    • /
    • 2005
  • Purpose: Dedicated animal PET is useful equipment for the study of new PET tracer. recently, microPET R4 was installed in the Korea institute of radiology and medical science. In this study, we measured the characteristics of scanner. Materials and methods: Resolution was measured using a line source (F-18:65 ${\mu}Ci$, inner diameter: 0.5 mm). The line source was put in the axial direction and was moved from the center of field of view to outside with 1 mm interval. PET images were reconstructed using a filtered back-protection and ordered subset expectation maximization. line source (16.5 ${\mu}Ci$, 78 mm) was put on the tenter of axial direction to measure the sensitivity when the deadtime was under 1%. Images were acquired during 4 minutes respectively from center to 39 mm outward. Delayed count was subtracted from total count and then decay was corrected for the calculation of sensitivity. Noise equivalent count ratio and scatter fraction were calculated using cylindrical phantom. Results: Spatial resolution of reconstructed image using filtered back-projection was 1.86 mm(radial), 1.95 mm(tangential), 1.95 mm(axial) in the tenter of field of view, and 2.54 mm, 2.8 mm, 1.61 mm in 2 cm away from the center respectively. Sensitivity was 2.36% at the center of transaxial field of view. Scatter fraction was 20%. Maximal noise equivalent count ratio was 66.4 kcps at 242 kBq/mL. Small animal images were acquired for confirmation of performance. Conclusion: Performance characteristics of microPET R4 were similar with reported value. So this will be a useful tool for small animal imaging.

Relationship between the Expression of Sodium Iodide Symporter and the Findings of $^{99m}Tc-MIBI$ Scintimammography in the Primary Breast Cancer (원발성 유방암에서 Sodium Iodide Symporter의 발현과 $^{99m}Tc-MIBI$ 유방스캔의 관계)

  • Seok, Ju-Won;Kim, Seong-Jang;Kwak, Hi-Suk;Lee, Chang-Hun;Kim, In-Ju;Kim, Yong-Ki;Bae, Young-Tae;Kim, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.6
    • /
    • pp.325-332
    • /
    • 2002
  • Purpose: Human Na+/I- symporter (hNIS) is known to be expressed in many tissues other than thyroid gland. The breast cancer cells are one of them and the possibility of radioiodine therapy in treatment of the breast cancer may be suggested. We investigated the expression rate of hNIS and the relationship between the expression of hNIS and the finding of 99mTc-MIBI scintimammographv in the breast cancer Materials and Methods: Surgically proved 56 patients with breast cancer were the subjects of this study The expression of hNIS were evaluated by immunohistochemistry and the results were compared to the findings of 99m7c-MIBI scintimammography. Results: Overall expression rate of hNIS was 41.1% in 56 patients. According to the pathologic diagnosis, it was 42.9% in 49 patients with invasive ductal carcinoma and 28.6% in the 7 patients with ductal carcinoma in situ. The expression rate of hNIS in the 41 cases with a focal increased uptake at he breast lesion on 99m7c-MIBI sointimammogram was 31.7%. That in the 15 cases without any abnormal uptake on the scan was significantly higher(65.7%, p<0.05). Conclusion: The expression rate of hNIS in the patients with breast cancer was not so high. The rate was higher in the patients with no increased uptake at the breast lesion on 99m7c-MIBI scintimammography.

A Study for Analysis of Image Quality Based on the CZT and NaI Detector according to Physical Change in Monte Carlo Simulation (CZT와 NaI 검출기 물질 기반 물리적 변화에 따른 영상의 질 분석에 관한 연구: 몬테카를로 시뮬레이션)

  • Ko, Hye-Rim;Yoo, Yu-Ri;Park, Chan-Rok
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.741-748
    • /
    • 2021
  • In this study, we evaluated image quality by changing collimator length and detector thickness using the Geant4 Application for Tomographic Emission (GATE) simulation tool. The gamma camera based on the Cadimium Zinc Telluride (CZT) and NaI detectors is modeled. In addition the images were acquired by setting 1, 2, 3, 4, 5, and 6 cm collimator length and 1, 3, 5, and 7 mm detector thickness using point source and phantom, which is designed by each diameter (4.45, 3.80, 3.15, 2.55 mm) with 447, 382, 317, and 256 Bq. The sensitivity (cps/MBq) for point source, and signal to noise ratio (SNR) and profile for phantom at the 4.45 mm by drwan the region of interests were used for quantitative analysis. Based on the results, the sensitivity according to collimator length is 2.3 ~ 48.6 cps/MBq for CZT detector, and 1.8 ~ 43.9 cps/MBq for NaI detector. The SNR using phantom is 3.6~9.8 for CZT detector, and 2.9~9.5 for NaI detector. As the collimator length is increased, the image resolution is also improved according to profile results based on the CZT and NaI detector. In addition, the senistivity for detector thickness is 0.04 ~ 0.12 cps/MBq for CZT detector, and 0.03 ~ 0.11 cps/MBq. The SNR using phnatom is 7.3~9.8 count for CZT detector, and 5.9~9.5 for NaI detector. As the detector thickness is increased, the image resolution is decreased according to profile results based on the CZT and NaI detector due to scatter ray. In conclusion, we need to set the geometric material such as detector and collimator to acuquire suitable image quality in nuclear medicine.

Evaluation of the usefulness of prone position for reducing the image distortion due to respiration in PET/CT (PET/CT 검사 시 호흡에 따른 영상 왜곡 감소를 위한 엎드린 자세의 유용성 평가)

  • Lee, Han Wool;Kim, Jung Yul;Choi, Yong Hoon;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.59-63
    • /
    • 2019
  • Purpose The motion due to respiration of patients undergoing PET/CT is a cause of artifacts in image and registration error between PET and CT images. The degree of displacement and distortion for tumor, which affects the measurement of Standard Uptake Value (SUV) and lesion volume, is especially higher for tumors that is small or located at the base of lungs. The purpose of this study was to evaluate the usefulness of prone position in the correction of image distortion due to respiration of patients in PET/CT. Materials and Methods The imaging equipment used in this study was PET/CT Discovery 600 (GE Healthcare, MI, USA). 20 patients whose lesions were identified in the middle and lower lungs from May to August 2018 were enrolled in this study. After acquiring whole body image in the supine position, additional images of the lesion area were obtained in the prone position with the same conditions. SUVmax, SUVmean, and volume of the lesion were measured for each image, and the displacement of the lesion on PET and CT images were measured, compared, and analyzed. Results The SUVmax, SUVmean, and volume, and displacement of the lesion were $4.72{\pm}2.04$, $3.10{\pm}1.38$, $4.68{\pm}3.20$, and $4.64{\pm}1.88$, respectively for image acquired in the supine position and $5.89{\pm}2.42$, $3.97{\pm}1.65$, $2.13{\pm}1.09$, and $2.24{\pm}0.84$, respectively for image acquired in the prone position, indicating that, for all the lesions imaged, SUVmax and SUVmean were higher and volume and displacement were smaller in the images acquired in prone position compared to those acquired in supine one(p<0.05). Conclusion These results showed that the prone position PET/CT imaging improves the quality of the image by increasing the SUV of the lesion and reducing the respiratory artifacts caused by registration error between PET and CT images. It is considered that the PET/CT imaging in the prone position is helpful in the diagnosis of the disease as an economical and efficient methods that correct registration error for the lesions in basal lung and reduce artifacts.

Correlation between Carotid Intima-media Thickness and Risk Factors for Atherosclerosis (경동맥 내중막 두께에 따른 죽상경화반의 위험요인과의 상관관계)

  • An, Hyun;Lee, Hyo Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.339-348
    • /
    • 2019
  • The purpose of this study was to investigate the effect of carotid artery ultrasound Respectively. The carotid intima-media thickness is known to have a significant correlation with cardiovascular disease and cerebrovascular disease. We investigated the relationship between carotid intima - media thickness, body mass index, waist circumference, the blood lipid value, fasting blood glucose, glycated hemoglobin, and blood pressure using carotid artery ultrasound. The carotid artery ultrasound was considered to be abnormality of IMT thickness over 0.8 mm and the presence or absence of atherosclerotic plaque was evaluated. Serological tests were used to compare the geologic value, fasting blood glucose level, and glycated hemoglobin. As a result, waist circumference (=.022), low density cholesterol (=.004), fasting blood glucose level (.019), and glycemic index (.002) were analyzed as predictors of atherosclerosis. In the ROC curve analysis, sensitivity was 87.80% (95% CI: 73.8-95.9), specificity was 41.67% (95% CI: 30.2-53.9), sensitivity was 78.05% (95% CI: 62.4-89.4) in low density lipoprotein, Specificity was 50.00% (95% CI: 38.0-62.0), sensitivity was 73.11% (95% CI: 57.1-85.8), specificity was 61.11 (95% CI: 48.9-72.4) and sensitivity was 82.93%-91.8) and a specificity of 43.06% (31.4-55.3). In logistic regression analysis, the risk of atherosclerosis was 0.248 times at waist circumference (WC)> 76 cm, 3.475 times at low-density lipoprotein (LDL-C) ${\geq}124mg/dL$, 0.618 at HbA1c> 5.4% It appeared as a times. We suggest that prospective study of carotid artery ultrasound should be performed for the effective prevention of cardiovascular diseases.

Multi-Institute, Single Group, Prospective Observational Study to Evaluate the Efficacy of Mucomyst® in Relieving Symptoms of Globus Pharyngeus Refractory to Proton Pump Inhibitor (양성자펌프억제제에 반응하지 않는 인두이물감 환자에서 "뮤코미스트Mucomyst®" 객담제거 및 상기도 염증치료를 통한 증상개선효과 평가 다기관, 단일군, 전향적 관찰 연구)

  • Park, Hannah;Park, Il-Seok;Lee, Sang Hyuk;Lee, Seung-Won;Lee, Sang Joon;Lee, Byung-Joo;Cheon, Yong-Il;Park, Jun-Ook;Oh, Kyoung Ho;Shin, Yoo Seob
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.33 no.1
    • /
    • pp.20-25
    • /
    • 2022
  • Background and Objectives Globus pharyngeus is one of the most common symptoms of patients visiting otorhinolaryngology out-patient clinic, and usually long-lasting, difficult to treat, and frequently recurrent. Mucomyst®, N-acetyl cysteine is an inhalation agent mainly used for mucolysis and reducing inflammation in airway via antioxidative effect. The purpose of this study was to evaluate the efficacy of inhaled Mucomyst® treatment in patients with globus pharyngeus refractory to proton pump inhibitor (PPI). Materials and Method We prospectively evaluated the efficacy of Mucomyst® in relieving symptoms of globus pharyngeus refractory to PPI in nine medical centers. Three hundred and three patients enrolled and finally 229 patients finished the inhaled Mucomyst® therapy for 8 weeks. We analyzed the change of Reflux Symptom Index (RSI), Reflux Finding Score (RFS), Visual Analogue Scale (VAS) for globus, and Globus Pharyngeus Symptom Scale (GPS) after use of Mucomyst® for 4 and 8 weeks. Results The GPS, RSI, RFS, and VAS score significantly decreased serially in patients who finished 8 week-inhalation treatment. The GPS improvement gap was significantly correlated with initial GPS (p<0.001) in multiple regression analysis. Conclusion Inhaled Mucomyst® therapy was effective for the reduction of both subjective and objective findings in refractory globus patients. This study might suggest new treatment option for patients with globus. However, further thorough studies would be needed to assess the real effect of inhaled Mucomyst® treatment as a standard treatment for globus.

The Cognitive Performance, Emotional and Behavioral Problems of the Children with ADHD Showing the Difference between Visual and Auditory Attention (시각 주의력과 청각 주의력의 차이를 보이는 주의력 결핍.과잉활동장애 아동의 인지기능과 정서 및 행동 문제)

  • Son, Jung Woo
    • Korean Journal of Biological Psychiatry
    • /
    • v.13 no.2
    • /
    • pp.70-81
    • /
    • 2006
  • Objective : The purpose of this study was to investigate the differences of the cognitive performance, emotional and behavioral problems among the attention-deficit/hyperactivity disorder(ADHD) groups that show the difference between visual and auditory attention. Method : Using 'ADHD Diagnostic System(ADS)', visual attention and auditory attention of 98 children diagnosed as ADHD were measured. According to the omission and commission error of ADS, they were divided into three groups ; 1) the group whose each visual omission and commission error scores were higher than each auditory omission and commission error scores(VV group), 2) the group whose each auditory omission and commission error scores were higher than each visual omission and commission error scores(AA group), 3) the group that was the rest of VV and AA group(M group). And the results of both the subscales of Korean Educational Development Institute-Wechsler Intelligence Scale for Children(KEDI-WISC) and the subscales of Korean Child Behavior Checklist(K-CBCL) among three groups were compared. Finally, the correlation between the visual omission, visual commission, auditory omission, auditory commission error and the results of KEDI-WISC, K-CBCL were investigated. Results : The results were as follows ; 1) In 98 ADHD children, the number of VV group(N=56) was higher than that of AA (N=10) and M group (N=32). 2) All mean scores of the subscales of KEDI-WISC of VV group were higher than those of M and AA group. The score of verbal IQ(p=.039) of VV group was significantly higher than that of AA group and the scores of block design(p=.015), Kaufman's factor 2(p=.045), performance IQ(p=.004) were significantly higher than those of M group. The score of full IQ(p=.004) were significantly higher than that of M and AA group. 3) The mean scores of all K-CBCL subscales of VV group were higher than those of M and AA group, except the score of Somatic complaint subscale. The score of Social subscale(p=.041) of VV group was significantly higher than that of AA group. The score of Withdrawn subscale(p=.021) of AA group was significantly higher than that of VV group. 4) There were no significant correlation between the scores of visual omission/commission error and those of each subscale of KEDI-WISC. But, there were many significant correlations between the scores of auditory omission/commission error and those of each subscale of KEDI-WISC. 5) There were significant correlation between the score of the visual omission error and that of Thought problem subscale(r=.205, p=.043) of K-CBCL. There were significant correlation between the scores of the auditory omission error and those of Social subscale(r=-.319, p=.001), Social problems subscale(r=.206, p=.042), Thought problem subscale(r=.235, p=.021). Finally, there were significant correlation between the scores of auditory commission error and those of Social subscale(r=-.241, p=.017), Thought problem subscale(r=.235, p=.020). Conclusion : The ADHD children whose auditory attention ability were higher than visual attention ability had relatively better cognitive performance and less emotional/behavioral problems than the others. The more comprehensive experiment will be needed about the cognitive performance, emotion and behavior problems of the ADHD children showing the difference between visual and auditory attention.

  • PDF

The Study on Usefulness of LEAP Collimator in Lung Ventilation SPECT (Lung Ventilation SPECT에서 LEAP Collimator의 유용성에 관한 연구)

  • Kim, Jung Soo;Kim, Soo Mee;Kim, Jin Eui;Lee, Jae Sung;Lee, Dong Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.18-24
    • /
    • 2012
  • Purpose : Although lung ventilation SPECT (LV-SPECT) has a good sensitivity in detection of deep lung lesions, it is difficult to apply the LV-SPECT to patients having breathing problems due to limited examination time. In this study, we evaluated the usefulness of LEAP collimator, which provides high detection sensitivity and tolerable resolution, for the LV-SPECT in terms of diagnostic accuracy and examination time. Materials and Methods : Four volunteers inhaled Technegas (370 MBq) and the lung ventilation planar scan (LVPS, 300 counts/view (cpv)) with LEHR collimator was performed using Siemens E.cam scanner as a reference test. LV-SPECT scans were performed with three collimators, LEHR, LEUHR, and LEAP, in low (7 kcpv) and high (70 kcpv) counting modes. The count ratios of left (LT) and right (RT) lung segments were calculated on the geometric mean view of anterior and posterior images for LVPS and on the summed coronal images of LV-SPECT, respectively. Comparing to LVPS, the usefulness of three different collimators for LV-SPECT was evaluated through statistical analysis (paired t-test), on count ratios of lung segments. Results : The average LT:RT ratio in LVPS was 47:53. For LV-SPECT, there were negligible difference of the LT:RT ratios (48:52 on average) among three different collimators in low and high counting modes. Comparing to standard LVPS with LEHR, all LV-SPECTs with different collimators resulted in similar diagnostic accuracy through paired t-test (p>0.05). The scan time in LVPS (6 views) was 17.3 min. For LV-SPECT (128 views) in low counting mode, it took 18.7 (LEUHR), 15.0 (LEHR), and 12.3 min (LEAP), respectively. Conclusion : Comparing to standard LVPS, the LV-SPECT with LEAP in low counting mode provided the comparable diagnostic accuracy in addition to shortened scan time.

  • PDF