• Title/Summary/Keyword: 의치상 레진

Search Result 58, Processing Time 0.019 seconds

THE COLOR STABILITY OF DIRECT DENTURE RELINE RESINS (의치상 직접 이장레진의 색조 안정성)

  • Kang Eun-Sook;Jeon Young-Chan;Jeong Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.160-168
    • /
    • 2003
  • Statement of problem : Direct denture reline resins tend to discolor during service in the oral environment by intrinsic and extrinsic factor. Purpose : This study was designed to evaluate the color stability of direct denture reline resins. Material and methods : Mild Rebaron(GC Corp., Japan), Meta Base M(Sun medical Co., Japan), Mild Rebaron LC(GC Corp., Japan) and as a control group, Vertex SC(Dentimex Zeist, Holland) were chosen for this study. Ten specimens of each direct denture reline resins were fabricated. Treatment methods designed for this study were the coffee staining test(7days) and the accelerated aging test(100hours). The color changes before and after treatment were measured by Tristimulous colorimeter(Yasuda seiki seisakusho, Ltd. Japan) and analyzed. Results All the direct denture reline resins subjected to the coffee staining test and the accelerated aging test showed noticible difference in color change. After coffee staining test, Meta Base M showed the highest color change followed by Vertex SC. Mild Rebaron LC and Mild Rebaron. There were no statistical differences between Meta Base M and Vertex SC and between Mild Rebaron LC and Mild Rebaron(p>0.05). After accelerated aging test. Mild Rebaron LC showed the highest color change followed by Vertex SC, Meta Base M and Mild Rebaron. There were no statistical differences only between Mild Rebaron and Mata Base M(p>0.05) but among the others, there were statistical differences(p<0.05). Conclusion : Within the limitation of this study, all the direct denture reline resins subjected to the extrinsic and intrinsic factors showed noticible difference in color change, and there were differences among manufacturers.

COMPARATIVE TENSILE BOND STRENGTH OF HEAT-CURED, COLD-CURED, AND LIGHT CURED DENTURE BASE RESINS BONDED TO CONTINUOUS-PRESSURE INJECTION TYPE DENTURE BASE RESIN (지속적 가압 주사식 열중합 의치상 레진에 대한 열중합, 자가중합 및 광중합 레진의 결합력에 관한 비교분석)

  • Whang Seung-Woo;Chung Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.3
    • /
    • pp.385-393
    • /
    • 1993
  • Injection processing of denture base resin was introduced by Pryer in 1942, in an attempt to reduce processing shrinkage. More recently a continuous-pressure injection type technique has been developed (SR-Ivocap, Ivoclar AG, Schaan, Liechtenstein.), and it reduced processing error and increased resin density. The purpose of this study was to compare tensile bond strength of heat-cured, cold-cured, and light-cured denture base resin bonded to continuous-pressure injection type resin. To know it, 60 cylindrical resin specimens were fabricated, and tensile bond strength were measured. The results were as follows : 1. The mean tensile bond strength bonded to continuous-pressure injection type resin was lower than bonded to conventional heat cured resin. But tensile bond strength of conventional heat cured resin bonding with light cured resin was lower than continuous-pressure injection type resin. 2. Of the tensile bond strength bonded to continuous-pressure injection type resin, tensile bond strength bonding with continuous-pressure injection type resin was the greatest(but not significantly different from bonding with conventional heat cured resin), followed by cold-cured, light-cured resin. 3. Of the tensile bond strength bonded to conventional heat cured resin, tensile bond strength bonding with conventional heat cured resin was the greatest and followed by continuous-pressure injection type resin, cold-cured resin, light-cured resin. According to these results, bonding of continuous-pressure injection type resin with conventional heat cured resin or continuous-pressure injection type resin is acceptable, but bonding with light-cured resin is questionable.

  • PDF

Effect of non-thermal atmospheric pressure nitrogen and air plasma on the surface properties and the disinfection of denture base resin (상온대기압 질소 및 공기 플라즈마가 의치상용 레진의 표면 특성과 살균효과에 미치는 영향)

  • Seo, Hye-Yeon;Yoo, Eun-Mi;Choi, Yu-Ri;Kim, Soo-Hwa;Kim, Kwang-Mahn;Kim, Kyoung-Nam
    • Journal of Korean society of Dental Hygiene
    • /
    • v.14 no.5
    • /
    • pp.783-788
    • /
    • 2014
  • Objectives : The purpose of this study was to investigate the effect of non-thermal atmospheric pressure plasma jet(NTAPPJ) on surface properties and Streptococcus mutans disinfection of denture base resin. Methods : Self-cured denture base resin (Jet denture repair resin, Lang dental Mfg, co., USA) was used to make specimen($12mm{\times}2mm$). To observe surface change before and after plasma process, surface roughness and contact angle were measured. For sterilization experiments, the surfaces of specimens were treated with nitrogen and air NTAPPJ for 1 minute after S. mutans was inoculated on the material surfaces. Results : Before plasma process, surface roughness of denture base resin was $0.21{\mu}m{\pm}0.02{\mu}m$. After air and nitrogen NTAPPJ process, surface roughness was $0.19{\mu}m{\pm}0.03{\mu}m$ and $0.18{\mu}m{\pm}0.01{\mu}m$ respectively. There was no significant difference(p>0.05). Contact angle of control group without plasma process was $83.81^{\circ}{\pm}3.14^{\circ}$, while after plasma treatment, contact angles of air NTAPPJ and nitrogen NTAPPJ groups were $63.29^{\circ}{\pm}2.27^{\circ}$ and $46.68^{\circ}{\pm}5.82^{\circ}$ respectively. The result showed a significant decrease in contact angle after plasma process(p<0.05). Compared to the control group 6020.33(CFU/mL) without plasma process, CFU decreased significantly after air NTAPPJ 90.75(CFU/mL) and nitrogen NTAPPJ 80.25(CFU/mL) treatment(p<0.05). Conclusions : It was considered that NTAPPJ can be used for denture disinfection without changing surface properties of materials.

A Study on the Influence of Finishing and Polishing Methods on the Gap between Denture Base Resin and Soft Liner (의치의 마무리와 연마법이 의치상 레진과 연성 이장재 간의 공극에 미치는 영향에 관한 연구)

  • Jung, Seung-Hwan;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.325-335
    • /
    • 2008
  • The junction between resilient denture liner and the denture base is difficult to finish and polish due to difference of the physical property of the materials. Gaps tend to be formed during finishing and polishing procedures. The purpose of this study was measuring the width of junctional gap between $Molloplast-B^{(R)}$ and denture base material after finishing and polishing procedure, and evaluating the effect of method and direction on gap width. $Molloplast-B^{(R)}$ was processed (according to the manufacturer's instruction) against Lucitone $199^{(R)}$ acrylic resin. 50 specimens were fabricated with a raised center section. All of specimens were examined and photographed with a stereoscopic microscope(x120), and the largest gap along the junction of $Molloplast-B^{(R)}$ and acrylic resin on each specimen was measured. One-way analysis of variance(ANOVA) and independent t-test at 95% confidence level were used to analyze the data and to compare groups. The results of this study were as follows. In comparison with finishing tools, the gap width was the largest in $Molloplast^{(R)}$-Cutter and the smallest in FSQ-cross cut bur. There was statistically significant difference between FSQ-cross cut bur and $Molloplast^{(R)}$-Cutter(p<0.05). There was no significant difference in gap width between the direction of polishing. The mean value of gap width was the smallest in case of no polishing, and the largest in case of polishing with pumice & tin oxide. There was statistically significant difference between pumice and pumice & tin oxide. From the results, it is concluded that the use of $Molloplast^{(R)}$-Cutter in clinic need serious consideration even though it has good cutting ability. Further careful study is needed for finishing and polishing methods for decreasing gap width in junction of two materials.

Strains of abutment and bones on implant overdentures (임플란트 피개의치에서 지대주와 골의 변형률에 관한 연구)

  • Kim, Myung-Seok;Heo, Seong-Joo;Koak, Jai-Young;Kim, Sung-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.222-231
    • /
    • 2009
  • Statements of the problem: Over the past decades, conventional complete dentures were used for various patients although they have incomplete function. Overdentures using dental implants could help the improvement of denture function. Purpose: The purpose of this study was to compare the strains of abutment and bone on implant overdenture between splinted and unsplinted type of prosthesis. Additionally, the strain values of parallel placed implant model and unparallel placed implant model were compared. Material and methods: Two acrylic resin model were prepared and two implants were placed at the canine positions in each model. In the first model, two implant were placed parallel. In the second model, two implants were placed with 10 degree labiolingual divergence. Two types of abutment were connected to the fixtures alternatively. One was splint type of Hader bar, the other was unsplint type of ball abutment. Overdentures were fabricated with corresponding attachment systems and seated on abutments. Strains of abutments and labial bone simulants were measured with electric resistance strain gauges when static load from 100 N to 200 N were applied to overdentures. Results: 1. Splinted type of overdentures using bar and clip showed higher absolute strain values. But the strain was compressive and the load was shared by two implants(P<.05). 2. Unsplinted type overdentures using ball and O-ring showed low absolute strain values(P<.05). 3. Labially inclined implant showed higher tensile strain values in unsplinted type of prosthesis than in splinted type of prosthesis. Lingually inclined implant showed rather low strain values under load(P<.05). 4. Non parallel implant model showed higher absolute strain values than parallel placed implant model comprehensively(P<.05).

EFFECTS OF METAL SURFACE TREATMENTS ON THE SHEAR BOND STRENGTH BETWEEN NI-CR DENTURE BASE AND RELINE RESINS (금속 표면처리방법이 니켈-크롬 합금 의치상과 첨상레진간의 결합강도에 미치는 영향)

  • Kim Young-Il;Jeong Chang-Mo;Jeon Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.4
    • /
    • pp.396-405
    • /
    • 2002
  • The purpose of this study was to evaluate the effects of four metal surface treatments on the shear bond strength of reline resin to Ni-Cr alloy. The denture base metal used in this study was Ni-Cr alloy(Ticonium Premium 100. Ticonium Co., U.S.A.). 120 specimens were divided into five metal surface treatments: sandblasting only, MR. BOND(Tokuyama Corp.. Japan), Cesead Opaque Primer(Kuraray Co., Japan), METALPRIMER II(GC Corp., Japan) and Super-Bond C&B(Sun Medical Co., Japan) after sandblasting. They were bonded with one of three reline resins Mild Rebaron(GC Corp., Japan), Mild Rebaron LC(GC Corp., Japan) and Meta Base M(Sun Medical Co., Japan). Then they were thermocycled 1,000 times at temperature of $4^{\circ}C$ and $60^{\circ}C$. The shear bond strengths were measured using the universal testing machine(Instron, Model 4301, England) with a cross-head speed of 2 mm/min. The results were as follows : 1. All metal primers and adhesive cement significantly improved the bond strength of reline resin to Ni-Cr alloy compared with sandblasted specimens. 2. In Mild Rebaron and Mild Rebaron LC. Cesead Opaque Primer showed the highest bond strength, but the differences among Cesead Opaque Primer, MR. BOND and METALPRIMER II were not significant. The bond strength of Cesead Opaque Primer was significantly different with that of Super-Bond C&B. 3. In Meta Base M, Super-Bond C&B showed the highest bond strength, but there was no difference between Super-Bond C&B and three metal primers. 4. There was no difference in the bond strength between Mild Rebaron and Mild Rebaron LC when metal surface was treated with the same method. 5. The bond strengths of Mild Rebaron and Mild Rebaron LC treated with Cesead Opaque Primer were higher than that of Meta Base M. The bond strengths of Mild Rebaron treated with MR. BOND and METALPRIMER II was higher than that of Meta Base M, However, there was no difference among three reline resins treated with Super-Bond C&B.

Strengthening effect of resin denture base by glass fiber reinforcement addition (유리섬유 보강재 첨가에 따른 레진 의치상의 강화효과)

  • Kim, Chong-Myeong;Kim, Ji-Hwan;Kim, Hea-Young;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.36 no.1
    • /
    • pp.1-7
    • /
    • 2014
  • Purpose: The aim of this study was analyzed by comparing the effect of glass fiber reinforcement addition on the strength of resin denture base. It was intended to provide a reference data useful for clinical application. Methods: The test specimens (length $64.0{\pm}0.1mm$, width $10.0{\pm}0.1mm$, thickness $1.0{\pm}0.1mm$, $1.5{\pm}0.1mm$, and $2.0{\pm}0.1mm$ respectively) were made. In the experimental groups resin denture base reinforced with glass fiber were fabricated. In the control groups resin denture base were fabricated by conventional method. After specimen fabrication was completed, transverse test was performed using a universal testing machine. Results: The transverse strength value in CON group was $83.08{\pm}9.07MPa$ for 1.0 mm, which ranked the highest in value. On the other hand, the value was $56.07{\pm}5.15MPa$ for 2.0mm, which ranked the lowest in value. And CON+SES group was $119.80{\pm}30.70MPa$ for 1.0mm, which ranked the highest in value. On the other hand, the value was $84.00{\pm}7.97MPa$ for 2.0mm, which ranked the lowest in value. Also, the flexural modulus value in CON group was $2,983.10{\pm}506.92MPa$ for 1.0mm, which ranked the highest in value. On the other hand, the value was $1,257.64{\pm}230.48MPa$ for 2.0mm, which ranked the lowest in value. And CON+SES group was $4,679.41{\pm}1578.29MPa$ for 1.0mm, which ranked the highest in value. On the other hand, the value was $2,512.36{\pm}527.09MPa$ for 2.0mm, which ranked the lowest in value. Conclusion: The reinforced glass fiber increased the strength of resin denture base, effected to reduce the thickness of resin denture base.

Research for Thickness Change of Denture Base in Flask when Injecting Valplast Flexible Partial Denture Resin (발플라스트 레진 주입 시 발생되는 의치상의 두께변화에 관한 연구)

  • Jang, Wan-Young;Kim, Bu-Sob;Chung, In-Sung
    • Journal of Technologic Dentistry
    • /
    • v.30 no.2
    • /
    • pp.47-56
    • /
    • 2008
  • This is a research for thickness change of denture base according to the shape of sprue & investment position of denture base in flask when injecting polyamid base resin for flexible partial denture as a part of study for Valplast among the flexible partial denture with a nylon base. It has been introduced several kinds of flexible partial denture product with a nylon base, but Valplast is the most widely used product among them. Valplast has been the most generally used material today since developed in 1950s in the United States as a material for flexible partial denture. Valplast is much more aesthetic than general metal-acrylic partial denture due to its translucent pink color and biocompatibility in terms of material characteristic. It keeps its flexibility for a long time after production, imposes a less burden on the teeth used as abutment, and it can be easily insert and remove due to its particular suppleness. Moreover, it is felt like real teeth more than metal-acrylic partial denture when being put in and takes alveolar bone under good protection since it receives occlusal force equally under the denture base. The most outstanding feature of Valplast is flexibility. The extent of its flexibility is determined by width & thickness of denture base. Considering general working procedure of Valplast, it can be seen that the thickness of denture base formed out of wax is increasing by the pressure while injecting resin. This research is to decide and test on the thickness increasing of Valplast by injecting pressure and the hypothesis upon that and is to prepare the basis estimating the increasing extent of thickness of denture base on the basis of the test result. In this test, it is expected occlusal malposition & thickness increasing of denture base by injecting pressure according to 4 kinds of test data which are to select 3 types of sprue method settling the forefront position at which the test material of fixed standard can be invested and to position the test material at the rearmost part keeping the minimum distance to set sprue. For 4 kinds of injecting test by investment position & sprue type, 20 test materials, 5 for each test were produced and a pressure of 1,180Kg was given with automatic injector of air cylinder type. The results are as follows: 1. For the amount of thickness increasing of denture base by investment position, the thickness of front investment is less increasing than the one of rear investment. 2. For the amount of thickness increasing of denture base by sprue type, the thickness of straight decompression sprue type which can absorb the injecting pressure after injecting polyamide base resin is less increasing than the other sprue types.

  • PDF