• Title/Summary/Keyword: 의료선

Search Result 626, Processing Time 0.022 seconds

A Study on Development of Guideline on Writing Technical Document for Electrical Medical Devices: Dental X-ray Equipment (치과용엑스선장치의 기술문서 작성을 위한 가이드라인 개발 연구)

  • Lee, Seung-Youl;Kim, Jae-Ryang;Lee, Jun-Ho;Park, Chang-Won
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.651-660
    • /
    • 2016
  • Due to recent population aging, the number of check-up for senior citizens has increased steadily. According to this trend, the market size of dental X-ray equipment and the number of approval and review for these devices have simultaneously increased. The technical document of medical device is required for approval and review for medical device, and medical device companies needs to have work comprehension and expertise, as the document needs to include the overall contents such as performances, test criteria, etc.. Yet, since most of domestic manufacturers or importers of medical devices are small businesses, it is difficult for them to recruit professional manpower for approval of medical devices, and submission of inaccurate technical documents has increased. These problems lead to delay of the approval process and to difficulties in quick entering into the market. Especially, the Ministry of Food and Drug safety (MFDS) standards of a dental extra-oral X-ray equipment, a dental intra-oral X-ray equipment, an arm-type computed tomography, and a portable X-ray system have been recently enacted or not. this guideline of dental X-ray equipment adjusting revised standards was developed to help relative companies and reviewers. For this study, first, the methods to write technical document have been reviewed with revised international and domestic regulations and system. Second, the domestic and foreign market status of each item has been surveyed and analyzed. Third, the contents of technical documents already approved by MFDS have been analyzed to select the correct example, test items, criteria, and methods. Finally, the guideline has been developed based on international and domestic regulation, through close review of a consultative body composed of academic, industrial, research institute and government experts.

의료산업화에 따른 의료비상승의 변화 메커니즘 : 병원의 영리화 & 의료의 산업화와 의료비의 영향에 대해서

  • Yun, In-Mo;Kim, Gi-Chan
    • Proceedings of the Korean System Dynamics Society
    • /
    • 2008.05a
    • /
    • pp.11-24
    • /
    • 2008
  • 의료의 산업화는 의료비의 상승을 가져올것인가. 이것은 전세계적으로 중요한 문제이다. 국민의료비가 지속적으로 상승할 경우 국가의 발전에 적지 않은 부담이 되기 때문이다. 이에의료산업화의 한 큰 조류인 병원영리화와 의료비의 상승의 관계를 연구하였다. 찬성과 반대의 논의가 한 시스템에서 어떻게 조화를 이루고 상생을 할 수 있을지에 대해서 연구를 하였다. 찬성과 반대가 별도의 주장이 아닌 한 시스템내에서 조화롭게 선순환에 참여 될 수 있는 연구결과를 제시한다. 본 연구를 통해서 다음과 같은 사항을 알 수 있다. 의료와 민간의료를 분리시키고, 영리병원이 아닌 연구중심의 민간영리병원이 더욱 효과적이며, 전국민의료의 실시는 상승하는 의료비를 완화시키고 동시에 서비스의 다양화와 고급화를 이룰 수 있으며 국부창출에도 도움이 될 것이다.

  • PDF

나눔으로 고객과 하나되는 KIHA - 지역사회에 전하는 따뜻한 나눔의 바람, 충북산업보건센터 청주에덴원 의료봉사

  • Hong, A-Reum
    • 월간산업보건
    • /
    • s.369
    • /
    • pp.56-59
    • /
    • 2019
  • 두 눈은 진심을 담는다. 어르신들과 아이들을 향한 눈길에는 세심한 배려가 엿보인다. 충북산업보건센터는 SK하이닉스, 대한적십자와 함께 지역사회의 건강증진을 위해 앞장서고 있다. 선한 기운으로 의료서비스에서 소외된 곳을 찾아다니는 이들의 봉사 현장으로 따라갔다.

  • PDF

Energy Distribution of X-rays from Medical Linear Accelerator (의료용 선형 가속기에서 발생된 X-선의 에너지 분포에 대한 고찰)

  • 김진기;김정홍;김부길
    • Progress in Medical Physics
    • /
    • v.2 no.1
    • /
    • pp.29-35
    • /
    • 1991
  • For accureate treatment planning, new models of dose calculations are being developed which require the knowledge of the energy spectra and angular distributions of the X-rays incident on the surface of the material. In this present study, we applied the Monte Carlo methods to the systematic analysis of the spectra distribution of X-ray beams produced by medical linear accelerator. As expected, the spectra become softer as the distance is farther from the central axis. also, its influenced by the geometrical dffect of head system.

  • PDF

Enhancing the Patient Satisfaction through Improving the Service Quality of Small and Middle-sized Hospital (중소의료병원의 서비스품질향상을 통한 환자만족도 제고방안)

  • Lee, Jeong Sun;Lee, Min Jung
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2015.07a
    • /
    • pp.127-128
    • /
    • 2015
  • 최근 우리나라는 대형병원이 증가하고 의료시장 개방에 따른 외국병원의 국내유입으로 중소병원은 환자의 수가 줄고, 우수한 의료진 확보가 어려워지는 등 심각한 경영난을 겪고 있다. 이에 본 연구에서는 중소병원 경쟁 확보방안을 제시를 위해 원격의료서비스를 포함한 의료서비스 품질이 환자만족도에 미치는 영향을 보고자 하였다. 중소병원에서 시행하는 사전 약 처방에 있어 전화원격의료서비스를 받은 고객을 대상으로 의료서비스품질이 환자만족도에 미치는 영향을 설문을 통해서 살펴보았다. 본 연구를 통해서 기존의 의료서비스인 병원 환경 및 의료진 서비스 요인보다는 원격의료서비스요인이 의료서비스만족도에 보다 높은 영향을 미치는 관계를 검증하였다. 이를 통해 연구적 시사점을 도출하고, 중소형 병원의 의료서비스개선을 위한 전략수립을 위한 기초자료를 제공하고자 하였다.

  • PDF

Removal of Power-Line Interference from Medical Equipment in a Real-time Environment. (의료기기에서의 실시간 전력선 잡음제거에 관한 연구)

  • 이강민;이종수;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1998.11a
    • /
    • pp.565-568
    • /
    • 1998
  • 본 논문에서는 의료기기 구현시 생체신호처리 과정에서 부가되는 전력선 잡음을 제거하기 위한 필터를 구현한다. 요즘 구현된 필터는 저주파 생체신호의 왜곡을 최소화하며, 전원 주파수의 고조파 성분만을 제거하는 특성을 가지며, 실시간 처리를 위하여 연산량을 최소화하도록 하였다.

  • PDF

3D Visualization of MR Images Using Interpolation of Viewing Transformed Images (뇌 MR영상의 뷰잉 변환 특성을 이용한 3차원 가시화를 위한 영상 보간)

  • 송미영;조형제
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2002.05c
    • /
    • pp.485-488
    • /
    • 2002
  • 본 논문은 의학 연구 및 교육, 환자 치료를 위해 보다 정확한 정보를 제공하고자 의료 영상 중에 가장 많이 사용하는 의료 영상인 뇌 MR 영상의 횡단면만을 가지고 3차원으로 가시화한다. 3차원으로 재구성하는데 있어서 원 영상의 모형을 자연스러운 표현을 위해서는 층 영상과 층 영상간의 보간 영상이 필요하므로 이를 생성하는 방법에 대해서 제안한다. 그리고 3차원 재구성에 필요한 정보를 추출하기 위해 각 영상에서 머리와 뇌 영역의 윤곽선 정보를 추출하고 가시화의 시간을 줄이기 위해 윤곽선 정보에서 특징점을 추출하여 이를 기반으로 하여 3차원으로 재구성 한다.

  • PDF

The Defect Characterization of digital imaging Crystals by radiation exposed (디지털 영상 형광체의 방사선 노출에 의한 결함 특성)

  • Kim, Chang-Gyu
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05a
    • /
    • pp.327-331
    • /
    • 2012
  • 양전자 소멸 분광법을 이용하여 X선으로 디지털 의료 영상을 회득하는 형광체를 X선 조사에 의한 형광체의 원자 크기 정도 결함의 특성을 조사하였다. 양전자와 전자의 쌍소멸에서 발생하는 511 KeV 감마선 스펙트럼의 수리적 해석 방법인 S-변수를 사용하여 결함의 정도를 측정하였다. 임상에서 X-선을 이용한 디지털 의료영상을 획득할 때 형광체로 사용하고 있는 시료를 사용기간별로 0, 2, 4, 6 구분하여 시료를 실험하였다. 각 시료들에서 측정된 S-변수는 0.4932부터 0.4956 정도의 변화를 보였다. 이에 상응하는 실험 방법으로 같은 시료에 X-선의 에너지와 조사시간 즉 6 MV 및 15 MV의 X-선을 사용하여 3, 6, 9, 그리고 12 Gy의 조사량을 변화시키면서 결함의 정도를 측정 비교하였다. 이 결과 형광체가 시용기간이 길어서 X선에 노출된 횟수가 많을수록 결함의 정도는 증가하는 경향을 보였고 X선의 에너지 강도가 강할수록 결함의 정도가 증가하는 경향을 보였다. 이것은 방사선에 노출된 빈도가 많을수록 영상을 획득하는데 보다 많은 선량이 요구되는 점과 영상의 화질이 저하는 현상을 결함특성 측정을 통하여 규명 하였다.

  • PDF