• Title/Summary/Keyword: 응축효율

Search Result 167, Processing Time 0.023 seconds

Research Trends of Metal-Organic Framework Membranes: Fabrication Methods and Gas Separation Applications (MOF 분리막의 연구 동향: 합성 방법 및 기체 분리 응용)

  • Lee, Jeong Hee;Kim, Jinsoo
    • Membrane Journal
    • /
    • v.25 no.6
    • /
    • pp.465-477
    • /
    • 2015
  • Recently membrane-based gas separation has attracted a lot of attention due to the growing demands on energy efficient separation processes. Current membrane-based gas separation is dominant by polymer membranes and limited mostly to non-condensable gases rather than condensable gases such as hydrocarbon isomers due to the limitation s of polymer materials. Metal-organic framework (MOF) materials, consisting of metal ions and organic ligands, have received a tremendous attention as membrane materials due to high surface area, controllable pore structure, and functionality. In this review, we provide a recent development of MOF membrane preparation methods and their gas separation applications.

Exergy analysis of R717 high-efficiency OTEC cycle (R717용 고효율 해양온도차 발전 사이클의 엑서지 분석)

  • Yoon, Jung-In;Son, Chang-Hyo;Yang, Dong-Il;Kim, Hyeon-Uk;Kim, Hyeon-Ju;Lee, Ho-Saeng
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.8
    • /
    • pp.829-835
    • /
    • 2013
  • This paper describes an analysis on exergy efficiency of proposed high-efficiency R717 OTEC power system to optimize the design for the operating parameters of this system. The operating parameters considered in this study include outlet pressure in an evaporator and high turbine, inlet pressure condenser and vapor quality at cooler outlet, respectively. The main results are summarized as follows : As the outlet pressure in an evaporator and vapor quality at cooler outlet of R717 OTEC power system increases, the exergy efficiency of this system increases, respectively. But outlet pressure in the high turbine, inlet pressure in the condenser of R717 OTEC power system increases, the exergy efficiency of this system decreases, respectively. And, incase of exergy efficiency of this OTEC system, the effect of inlet pressure in an evaporator and outlet pressure in the high turbine on R717 OTEC power system is the largest and the lowest among operation parameters, respectively.

Development of Structural Analysis and Pre-post Program for Mega Frame System (초대형 골조시스템 전용 전후처리 및 해석프로그램의 개발)

  • Kim Hyun-Su;Lee Dong-Guen
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.19 no.3 s.73
    • /
    • pp.283-293
    • /
    • 2006
  • Recently, various types of structural systems for skyscrapers are studied as the height and size of the building structures rapidly increase due to social and economical needs. The mega frame system among them, which is the structural system developed recently, is known as a suitable structural system for skyscrapers because this structural system has sufficient stiffness against the lateral forces by combination of mega members which consist of many columns and girders. Since the mega frame structure has significant numbers of elements and nodes, it takes tremendous times and computer memories to analyze and design the structures. Therefore, the exclusive structural analysis program for mega frame system is developed to reduce the efforts and time required for the analysis and design of mega frame structure. To this end, an efficient modelling technique using the characteristics of mega frame structures and an efficient analytical model, which uses a few DOFs selected by the user using the matrix condensation method, are developed in this study. Static and dynamic analyses are conducted using an example structure. The effectiveness and accuracy of the developed program we verified by the comparison between the results of the proposed method and the conventional method.

반도체 및 Optic Industries 클린룸 배기가스의 오염제어 및 청정화기술

  • 황유성
    • Air Cleaning Technology
    • /
    • v.17 no.4 s.67
    • /
    • pp.39-57
    • /
    • 2004
  • 첨단산업으로 불리는 반도체, LCD, PDP, 유기EL(OLED) 등의 생산 공정은 고도의 청정상태를 요구하며, 때문에 이들의 생산공정 중 대부분이 클린룸 내에서 이루어진다. 클린룸 내에서의 주요공정은 크게 박막형성(Layering), 노광(Photo Lithography), 식각(Etching) 등 3가지 공정으로 나눌 수 있으며, 반도체 제조공정의 경우 특별히 도핑(Doping) 공정이 추가된다. 오염물질을 함유하는 클린룸 배기는 일반적으로 산, 알칼리, Toxic(PFCs, Flammable), VOC 등으로 분류하며, 각각의 배기는 각 배기특성에 맞는 오염제어 장치를 통해, 정화된 후, 대기로 방출된다. 산, 알칼리 배기는 일반적으로 최종 단계에서 중앙집중식 습식스크러버에 의해 흡수, 중화 처리되며, VOC의 경우 농축기(Concentrator) & 축열식 열 산화장치(RTO) 설비에 의해 연소 처리된다. 하지만 CVD공정으로부터의 배기가 주를 이루는 Toxic배기의 경우, 다량의 PFCs(과불소화합물) 가스를 함유하고 있는 이유로, 대부분 클린룸 내부에 P.O.U(Point of use) 처리장치가 설치되며, P.O.U에 의해 1차 처리된 후 최종적으로 중앙집중식 습식스크러버를 거쳐 대기로 방출된다. 알칼리배기의 주성분으로는 암모니아($NH_3$), HMDS (Hexa Methyl DiSilazane), TMAH (Tetra Methyl Ammonium Hydroxide), LGL, CD 등이며 흡수액에 황산(Sulfuric Acid)용액을 공급, 중화처리하고 있다. 탄소성분을 먹이로 하는 미생물의 번식에 의한 막힘 문제를 제외하고는 큰 문제가 없다. 하지만 Toxic배기 및 산배기의 경우 처리효율이, 가스흡수 이론에 의한 계산결과와 비교할 때, 매우 저조하게 나타나는 효율부족 현상을 겪고 있으며, 이는 잔여 PFCs 가스성분 및 반응에어로졸, 응축에어로졸 등의 영향으로 추정하고 있다. 최근 Toxic 배기의 경우, P.O.U 설비를 Burn & Wet type으로 변경하여, 배기 중 PFCs 및 반응에 에어로졸($SiO_2$)의 농도를 원천적으로 감소시키는 노력이 진행 중이다. 산배기의 경우, 산결로 현상에 의한, 응축에어로졸이 문제가 되고 있으나 내식열교환기(Anti-Corrosive Heat Exchanger), 하전액적스크러버 시스템(Charged Droplets Scrubber System), Wet ESP(Wet Electrostatic Procipitator) 등의 도입을 통해 문제해결을 위한 노력을 경주하고 있다.

  • PDF

Development of Cascade Refrigeration System Using R744 and R404A - Analysis on Performance Characteristics - (R744-R404A용 캐스케이드 냉동시스템 개발에 관한 연구(1) - 성능 특성에 관한 분석 -)

  • Oh, Hoo-Kyu;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.182-188
    • /
    • 2011
  • In this paper, analysis on the performance characteristics of R744-R404A cascade refrigeration system is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include subcooling and superheating degree, compressor efficiency, and condensing and evaporating temperature in R404A high- and R744 low-temperature cycle, respectively. The main results were summarized as follows : It was observed that the highest COP of the system is achieved by higher superheating degree in R744 cycle than that in R404A cycle. The COP of the system increased by giving the subcooling degree in both cycles. The COP of the cascade system is the highest value when the system is operated at an optimum evaporation temperature.

Characteristics of the Air Heat Exchanger for the Improvement of the Heat Pump COP (열펌프 성능향상을 위한 공기 열교환기 특성)

  • 노정근;송현갑;박용규
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.151-157
    • /
    • 2002
  • 화석에너지에 대한 경제적 부담과 환경오염문제를 줄이기 위하여 열펌프의 성능계수향상을 위하여 냉온 공기열교환기(HEEVA)를 고안하였고, 이 열교환기의 열특성과 성능계수향상에 미치는 영향을 분석하기 위하여 냉.난방 실험을 수행하였다. HEEVA에 의한 찬 공기와 더운 공기의 온도변화, 전열량 및 냉온 공기열교환기 효율, 총열전달계수등을 측정분석하였고, 냉난방시 외기온에 따른 열펌프의 성능계수, 소비전력, 응축기.증발기 출구 공기토출 온도 변화를 측정 분석함으로서 다음과 같은 결과를 얻을 수 있었다. 1. 외기온이 -4~11$^{\circ}C$로 변할 때 열펌프의 난방과정에서 HEEVA 찬공기 입출구 온도차는 4.5$^{\circ}C$에서 9.$0^{\circ}C$로 증가하였으며, HEEVA에 의한 영향으로 2~6$^{\circ}C$상승된 공기가 증발기 입구로 유입되어 냉매증발을 촉진하였다. 2. 실온이 4~22$^{\circ}C$일 때 HEEVA 더운공기 입출구 온도차는 3$^{\circ}C$에서 7$^{\circ}C$로 증가하였으며, 응축기에 유입되는 공기온도를 3~8$^{\circ}C$낮게 함으로서 압축기 소모전력을 감소시켜 COP 상승 효과를 나타냈다. 3. 외기온과 실온변화에 따라 풍량 346m$^3$/hr의 찬 공기가 받은 열량과 풍량 747m$^3$/hr의 더운 공기가 준 열량간의 차는 50~150kcal/hr로 나타났으며, 더운 공기가 준열량과 찬 공기가 받은 열량의 비가 83~98% 이었으므로 HEEVA의 열 교환율은 91% 을 보였다. 4. 총합열전달계수는 이론값이 실험 값보다 1~3W/m$^2$K 크게 나타났으며, 이 결과는 두 값 사이에 10% 내.외의 편차로서 Nusselt수를 구하기 위한 Petukhov상관식의 자체오차 15%에 비해 크지 않은 오차범주에 속하며, 이론상의 총합열전달계수 유도식의 타당성을 입증한 것이라 하겠다. 5. HEEVA를 작동함으로서 난방시 COP가 HEEVA를 작동하지 않았을 경우보다 0.3~0.5 향상된 것으로 나타났다. 이것은 HEEVA가 겨울철 난방에 효율을 높일수 있는 것으로 판단된다.

  • PDF

The Heat Pump Application to the Food Concentration (열 펌프의 식품 농축에의 이용 연구)

  • Park, Noh-Hyun;Kim, Byeong-Sam;Kang, Tong-Sam;Shin, Dong-Hwa
    • Korean Journal of Food Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.486-491
    • /
    • 1987
  • The performance and applicability to food concentration of heat pump were investigated. During heating the water of spa from $43^{\circ}C$ to $51^{\circ}C$, COP's of heat pump (R-12, 150 HP) were 4.03 at heating part and 3.5 at cooling part. And, the efficiency of compressor (${\alpha}$) was 0.477 While the city water was heated to $39^{\circ}C$ by heat pump (R-22, 10 HP), its COP's were 3.0 at heating part and 1.87 at cooling part. During concentrations sucrose solution by centrifugal evaporator (ALFA-LAVAL CO, CTIB) with heat pump, heat capacity for condensating water vapor was required greater 15% than the latent heat for concentrating and then the overall heat transfer coefficient was $1196\;Kcal/m^{2}.\;h.\;^{\circ}C$. When low temperature concentration ($30-35^{\circ}C$, 28-40 Torr) of garlic extract was carried out by the water of $60^{\circ}C$ and $15^{\circ}C$ adjusted by heat pump, the ratio of heat capacity for concentrating vs. that for condensating of water vapor was 0.961.

  • PDF

Design of Multi Fuzzy Controller for HVAC System (HVAC 시스템에 대한 Multi Fuzzy 제어기 설계)

  • Jung, Seung-Hyun;Choi, Jeoung-Nae;Oh, Sung-Kwun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1923-1924
    • /
    • 2006
  • 본 논문은 HVAC(heating, ventilating, and air conditioning) 시스템에 대하여 Multi Fuzzy 제어기 설계를 제안한다. HVAC 시스템은 Compressor(압축기), Condenser(응축기), Evaporator(증발기), Expansion Valve 로 구성되며, 각각의 기기에 대한 제어가 독립적으로 이루여져 있다. 기존의 제어가 한 제어기를 사용한 단일방식으로 이루어지다보니 HVAC 시스템의 특성인 냉매의 상태가 달라지면 시스템 전반적으로 그 영향이 파급되는 부분까지 고려를 해 주지 못하고, 제어기의 성능이 효율적이지 못했다. 본 논문에서는 비선형성이 강하고 불확실하며 복잡한 시스템을 쉽게 제어할 수 있는 Fuzzy 제어기를 구성하여 Expansion Valve 와 Compressor 에서 동시에 제어하는 Multi 제어기를 설계한다. 제안된 Multi Fuzzy 제어기는 HVAC 시스템의 효율성과 안정성에 기초하여, 과열도와 저압을 제어한다.

  • PDF

Development of an efficient 3-node plate bending element by using the Hellinger-Reissner functional (Hellinger-Reissner 범함수를 이용한 효율적인 3절점 판 유한요소의 개발)

  • Lee, Youn-Gyu;Choi, Chang-Koon;Lee, Phill-Seung
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.760-763
    • /
    • 2011
  • 본 논문의 목적은 효율적인 3절점 판 유한요소를 개발하는 것이다. Hellinger-Reissner 범함수에 근거한 혼합정식화(mixed formulation)를 사용한다. 잠김현상을 일으키는 전단변형률장을 독립적으로 분리한 후, MITC(Mixed Interpolation of Tensorial Components)방법을 이용하여 대체전단변형률장(assumed transverse shear strain field)을 구성한다. 추가적으로 회전된 반변기저벡터(contravariant base vector)로 정의된 근사전단변형률장(approximated transverse shear strain field)에 미지수(unknowns)를 도입하여 혼합정식화를 완성시키고 정적응축(static condensation)을 통해 최종 강성행렬을 구성한다. 거짓영에너지모드시험(spurious zero energy mode test), 조각시험(patch test), 등방성시험(isotropic test) 등을 실시하였으며, 4변 완전구속 정사각형 판 구조물과 60도 기울어진 단순지지 판 구조물 등 예제들을 해석하여 MITC3판 유한요소와 수렴성능을 비교하였다.

  • PDF

Parallel Processing of Structural Optimization Using PC Transputer System (PC 트랜스퓨터 시스템을 이용한 구조최적화의 병렬처리)

  • 황진하;박종희
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.12 no.2
    • /
    • pp.233-241
    • /
    • 1999
  • 본 연구는 개별 메모리를 갖는 소결합 구조의 MIMD형 병렬컴퓨터인 트랜스퓨터시스템 하에서 구조최적화를 위한 병렬처리 과정을 보이고 시험모델에 적용하여 타당성 및 효율성을 검증한다. 전체 최적화과정의 대부분을 차지하는 해석 및 민감도 알고리즘은 영역단위의 병렬성을 갖는 부구조화에 근거하고 하드웨어 구성에 맞춰 변환 재구성한다. 각 노드간 통신은 정적응축과 설계도함수에 한정, 그 횟수를 최소화하고 그들을 동기화하므로써 개별메모리형 연산모델의 약점인 통신비용의 문제를 해소한다. PC를 호스트로 한 수치실험은 고속화 효율성 면에서 고무적인 결과를 보여주고 있으며, 이런 점에서 시스템의 확장성을 함께 고려한다면 트랜스퓨터 시스템에 기초한 병렬처리는 공학 환경의 변화와 요구에 부응하는 좋은 대안이 될 수 있다.

  • PDF