• Title/Summary/Keyword: 응집제어

Search Result 124, Processing Time 0.027 seconds

Development of Datamining Roadmap and Its Application to Water Treatment Plant for Coagulant Control (데이터마이닝 로드맵 개발과 수처리 응집제 제어를 위한 데이터마이닝 적용)

  • Bae, Hyeon;Kim, Sung-Shin;Kim, Ye-Jin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.7
    • /
    • pp.1582-1587
    • /
    • 2005
  • In coagulant control of water treatment plants, rule extraction, one of datamining categories, was performed for coagulant control of a water treatment plant. Clustering methods were applied to extract control rules from data. These control rules can be used for fully automation of water treatment plants instead of operator's knowledge for plant control. To perform fuzzy clustering, there are some coefficients to be determined and these kinds of studies have been performed over decades such as clustering indices. In this study, statistical indices were taken to calculate the number of clusters. Simultaneously, seed points were found out based on hierarchical clustering. These statistical approaches give information about features of clusters, so it can reduce computing cost and increase accuracy of clustering. The proposed algorithm can play an important role in datamining and knowledge discovery.

Improvement of Cooling Water Quality by Coagulation and Sedimentation (응집침전에 의한 냉각수질 향상)

  • Woo, Dal-Sik;Jo, Kwan-Hyung
    • Proceedings of the KAIS Fall Conference
    • /
    • 2008.05a
    • /
    • pp.369-371
    • /
    • 2008
  • 본 논문은 철강공장의 냉각수 처리 시스템에서 고로 집진수를 대상으로 한 응집교반실험을 실시한 결과, 주기적인 관 갱생작업(산세척)과 분산제의 주입이 필요하며, 음이온 고분자응집제에 양이온 고분자응집제를 첨가하여 사용할 경우에 탁도 제거측면에서 우수하였다. 급속교반 후 완속교반을 적용할 경우 급속교반 후 침전보다 탁도 제어 효과가 더 우수한 것으로 관찰되었으므로, 침전지의 처리효율을 증가시키기 위해서는 급속교반과 완속교반이 동시에 필요하였다.

  • PDF

A Concurrency/Coherency Control Approach using the I/O node for the Shared Disk Parallel Database (공유 디스크 병렬 데이타베이스에서 입출력 노드를 이용한 동시성/응집성 제어 기법)

  • 김용걸;김양우;진성일;임기욱
    • The Journal of Information Technology and Database
    • /
    • v.3 no.2
    • /
    • pp.25-38
    • /
    • 1996
  • 병렬 데이타베이스 소프트웨어 구조 중 공유 디스크 구조는 트랜잭션간의 병렬도 향상, 적재 균형 용이, 데이타 재할당 용이 등의 장점을 가지고 있어 병렬 데이타베이스 구조 중 가장 효율적인 성능이 기대되고 있다. 그러나 공유 디스크 구조는 동시성/응집성 제어를 위한 추가적인 메세지의 증가로 네트워크 트래픽이 증가되는 문제를 가지고 있으며 이러한 문제를 완화시키고자 하는 연구가 계속되고 있다. 본 논문에서는 공유 디스크 구조의 동시성/응집성 제어를 위한 추가적인 메세지를 감소시키는 기법을 제안하고, 기존 기법과의 비교를 위해 성능 모델을 제시하였으며, 이를 통한 시뮬레이션을 수행하여 성능을 분석하였다.

  • PDF

Coagulation Characteristics of Wastewater Treatment Process Using Completely Mixed Chamber (완전 혼화조를 이용한 폐수처리 공정의 응집특성)

  • Kim, Dong-Jun;Park, Sang-Kyoo;Lee, Yong-Ho;Yang, Hei-Cheon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.8
    • /
    • pp.1187-1195
    • /
    • 2009
  • The objective of this study is to investigate the coagulation characteristics of the completely mixed chamber for wastewater treatment. The completely mixed chamber system was composed of the reservoirs, the three-stage mixing and coagulation part with propeller impeller, the injection parts of coagulants, a sedimentation tank and a control panel. Wastewater sample of pH 8.5 and initial turbidity 1,000NTU was prepared using sludge taken from a tunneling work site. The efficiency of turbidity removal with increasing the dosage of coagulant aids increased by about 99%. Increasing coagulant above the optimal dosage, however, the efficiency of turbidity removal decreased.

Application of Data Mining for Coagulant Dosage of Water Treatment Plants Corresponding to Input Conditions (원수조건에 따른 상수도 응집제 종류와 주입량 결정을 위한 데이터 마이닝 적용)

  • 배현;김성신;최대원;이승태;김예진
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2004.10a
    • /
    • pp.223-226
    • /
    • 2004
  • 본 논문은 정수장에서 사용하는 응집제의 종류와 주입량을 결정하기 위한 시스템 개발에 관한 내용이다. 정수장은 여러 단위 처리장으로 구성되며, 탁도와 색도를 제거하기 위하여 혼화지에서 응집제를 주입하여 침전을 시킨다. 현재까지 응집제 결정을 위해 Jar-test를 이용하였는데, 이 방법은 사람의 주관적인 판단에 의존하므로 실험 오차가 발생할 수 있다. 특히 정수장의 자동화를 위한 시스템 개발에서 가장 큰 걸림돌로 작용하고 있다. 본 논문은 이러한 문제점을 해결하기 위하여 데이터 마이닝 기법 등을 이용한 응집제 종류와 양을 결정하는 제어기를 개발하였다.

  • PDF

Performance characteristics of inline mixing and coagulation system (인라인 혼화 및 응집 시스템의 성능특성)

  • Kim, Dong-Jun;Park, Sang-Kyoo;Yang, Hei-Cheon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.269-275
    • /
    • 2014
  • The objective of this study was to investigate the performance characteristics of an inline mixing and coagulation system for water treatment based on the process intensification concept. Three-stage inline mixing and coagulation system was composed of the reservoirs of source wastewater, the fixed quantity injection pumps of coagulants, the mixing and coagulation tubes, a sedimentation tank and a control panel. In the equal dosage of coagulant and coagulant aids, the turbidity removal with increasing the dosage of coagulant aids was about 3 times higher than that with increasing the dosage of coagulant. In the condition of the equal mixing and coagulation time, the turbidity removal of inline mixing and coagulation system was about 4.6 times higher than that of mechanical type.

A Feasibility Study on Optimization System of Coagulant Dosing for Total Phosphorous Treatment (총인 처리를 위한 응집제 주입량 최적제어 시스템의 적용성 연구)

  • Seo, Jeong-Mi;Cho, Young-Beom;Choi, Ye-Mook;Park, Chul-Hwi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.7
    • /
    • pp.483-491
    • /
    • 2014
  • In this study, we developed an M-COS (molit coagulant-dosing optimization system), which enables to apply the optimum coagulant dose determined in real time, in order to satisfy the total phosphorus (TP) regulation (0.5 mg/L), and then tested its field applicability. Field tests were conducted at three different periods in 2014 in a pilot plant where the M-COS was installed. Coagulant reduction rate by the M-COS was 10.4%, 15.3%, and 9.0% for each period (average 11.6%), when comparing with a control where coagulants were applied at a constant rate. Total cost for the M-COS or control was estimated by summing up the coagulant cost and sludge treatment cost, and then the resulting cost increase was predicted. Cost reduction rate by the M-COS was 13.8%, 20.0%, and 11.4% for each period (average 15.0%). This study indicates that the M-COS can be an alternative to a conventional system for TP treatment, with a better cost efficiency.

Application of Data Mining for Coagulant Dosage of Water Treatment Plants Corresponding to Input Conditions (원수조건에 따른 상수도 응집제 종류와 주입량 결정을 위한 데이터 마이닝 적용)

  • Bae Hyeon;Kim Sungshin;Choi Dae-Won;Lee Seung-Tae;Kim Yejin
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.15 no.1
    • /
    • pp.53-58
    • /
    • 2005
  • Water shortages are gradually accelerating because higher standards of living are required and water resources are more heavily utilized. Therefore, effective water treatment is necessary in order to retain the required qualify and amount of water. General treatment includes coagulation, flocculation, filtering, and disinfection. coagulation, flocculation, and disinfection are major components of water treatment processes. In this paper, a new automatic decision algorithm is proposed for coagulation. The proposed method shows how to determine the coagulant type and amount using data mining techniques.

Effects of CellCaSi and Bioflocculant on the Control of Algal Bloom (규산질다공체와 미생물응집제의 녹조제어 효과)

  • 박명환;이석준;윤병대;오희목
    • Korean Journal of Environmental Biology
    • /
    • v.19 no.2
    • /
    • pp.129-135
    • /
    • 2001
  • The effects of CellCaSi and bioflocculant on the control of algal bloom were investigated in enclosures in a small eutrophic pond. The bioflocculant produced by a bacterial strain S-2 was finally selected to remove Microcystis aeruginosa which was a dominant species of algal bloom in the pond. Enclosure experiment showed that phosphorus concentration decreased dramatically from $131\mu{g}\ell^{-1}$ (Control) to $1-14\mu{g}\ell^{-1}$ in three CellCaSi-enriched enclosures. Chlorophyll $-\alpha$ concentration also decreased from $215\mu{g}\ell^{-1}$ (Control) to $59\mu{g}\ell^{-1}$ by the addition of CellCaSi $(1g\ell^{-1}$, bioflocculant $(2ml\ell^{-1}$, calcium chloride $(1g\ell^{-1}$ and ferric chloride $(2mg\;Fe\ell^{-1})$ in Enclosure 4. From the results of the mouse acute toxicity test of the S-2 bioflocculant and the goldfish survival test in enclosures, it seems that both the S-2 bioflocculant and the CellCaSi do not show any severe toxicity in water system. Consequently, it was concluded that the bioflocculant and the CellCaSi could be used to control algal bloom in eutrophic waters by removing phosphorus and chlorophyll$-\alpha$.

  • PDF

Determination of Set Point of Streaming Current for Optimum Coagulation (최적 응집을 위한 Streaming Current의 기준값 설정에 관한 연구)

  • Yu, Myong-Jin;Jang, Mi-Jeong;Park, Gui-Su
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.1
    • /
    • pp.34-41
    • /
    • 2006
  • The objectives of this study were to investigate the affecting factors on streaming current(SC) and to evaluate set point(SP). For the study, a pilot scale apparatus with a capacity of 12 L/min was operated at Guui water intake of Seoul. SC was monitored with varying poly aluminium chlorides(PACs) dose and water quality parameters like conductivity, turbidity, temperature, and pH. The removal efficiencies were evaluated in terms of turbidity and dissolved organic carbon(DOC) with varying coagulation conditions. The effects of affecting factors on SC and SP were also estimated. According to the result observed from the variation of SC with water quality parameters during the experimental period, tendencies of SC and conductivity were very similar, and SC and conductivity had a strong linear relation. At the optimum condition of coagulation, SP decreased as the rainy season changed to the dry season, during the experimental period. Especially, in condition of low turbidity, conductivity had relatively more effect on SC than turbidity. As conductivity increased, SP decreased and coagulant dose per unit increase of SC gradually increased. In view of the results so far obtained, it may be possible to determine the SP range considering the real time variation of water quality, especially conductivity.