Browse > Article

Determination of Set Point of Streaming Current for Optimum Coagulation  

Yu, Myong-Jin (Department of Environmental Engineering, University of Seoul)
Jang, Mi-Jeong (Department of Environmental Engineering, University of Seoul)
Park, Gui-Su (Department of Environmental Engineering, University of Seoul)
Publication Information
Abstract
The objectives of this study were to investigate the affecting factors on streaming current(SC) and to evaluate set point(SP). For the study, a pilot scale apparatus with a capacity of 12 L/min was operated at Guui water intake of Seoul. SC was monitored with varying poly aluminium chlorides(PACs) dose and water quality parameters like conductivity, turbidity, temperature, and pH. The removal efficiencies were evaluated in terms of turbidity and dissolved organic carbon(DOC) with varying coagulation conditions. The effects of affecting factors on SC and SP were also estimated. According to the result observed from the variation of SC with water quality parameters during the experimental period, tendencies of SC and conductivity were very similar, and SC and conductivity had a strong linear relation. At the optimum condition of coagulation, SP decreased as the rainy season changed to the dry season, during the experimental period. Especially, in condition of low turbidity, conductivity had relatively more effect on SC than turbidity. As conductivity increased, SP decreased and coagulant dose per unit increase of SC gradually increased. In view of the results so far obtained, it may be possible to determine the SP range considering the real time variation of water quality, especially conductivity.
Keywords
Coagulation; SCD; SP; PACs; Conductivity;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Bryant, R. L., 'Optimizing coagulation with the streaming current monitor,' J of NEWWA., 12, 268-275(1996)
2 서울특별시 수도기술연구소, '흐름전위를 이용한 응집제 투입률 변화에 관한 연구,' 수도기술연보, 제2호, 160-165(2000)
3 한무영, 한정철, '응집공정 개선을 위한 SCD의 적용,' 대한토목학회 학술발표회 논문집, (2), 519 - 522(1995)
4 한종화, 흐름전위와 PID 제어를 이용한 응집 공정 평가, 서울시립대학교 대학원 석사학위 논문(2003)
5 Abu-Orf, M. M., Dentel, S. K, 'Automatic control of polymer dose using the streaming current detector,' Water Environmental Research, 70(5), 1005 -1018(1998)   DOI   ScienceOn
6 안상진, 최계운, 윤남중, '저탁도 원수에서 응집 및 침전 인자가 탁도 제거 효율에 미치는 영향,' J. of KTSWT, 4(2), 11-15(1996)
7 Fanceschi, M., Girou, A., Carro-Diaz, A. M., Maurette, M. T., and Puech-Costes, E., 'Optimization of the coagulation-flocculation process of raw water by optimal design method,' Water Res., 36, 3561- 3572(2002)   DOI   ScienceOn
8 윤태일, '웅집제 주입량 콘트롤을 위한 Streaming Current Detector의 이용,' 대한환경공학회지, 8(1), 69-76(1986)
9 전항배, 이영주, 채선하, 'SCD를 이용한 알루미늄 수화물의 하전 및 응집특성 평가,' J. of KSEE, 25(4), 454-459(2003)
10 Mayers, D., Surfaces, interfaces and colloids: principles and application 2nd ed., WILEY-VCH, U.S.A.(1999)
11 Elicker, M. L., Resta, J. J., Hunt, J. W., and Dentel, S. K., 'Fundamental considerations in use of the streaming current detector,' Chemical Water and Wastewater Treatment II, CHEMICAL WATER AND WASTEWATER TREATMENT, 165 - 180(1992)
12 Liu, J. C. and Wu, M. D., 'Fuzzy control of coagulation reaction through streaming current monitoring,' Water Science and Technology, 36(4), 127 -134(1997)   DOI   ScienceOn
13 이준호, 응집공정에서 흐름전위를 이용한 응집제 투입률 에 관한 연구, 서울시립대학교 도시과학대학원 석사학위 논문(2001)
14 전항배, 이준상, 이선주, 'SCD를 이용한 $ Ca^{2+}$ 이온이 자연유기물질 응집에 미치는 영향,' 대한환경공학회지, 25(6), 753 - 759(2003)
15 유명진, 조용모, 상수처리-정수의 기술, 동화기술, 서울 (1996)
16 Dental, S. K. and Kingery, K. M., 'Using streaming current detectors in water treatment,' J AWWA, 3, 85 - 94(1989)